Jason S. Hertz
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jason S. Hertz has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christopher L. Meehan
Department of Civil, Construction, and Environmental Engineering, University of Delaware, Newark, USA
1 shared publication - Greg Moormann
Staff Engineer, Langan Engineering and Environmental Services, 21 Penn Plaza, 360 West 31st Street, 7th floor, New York, NY 10001
1 shared publication - Marc J. Gallagher
Staff Engineer, Langan Engineering and Environmental Services, 21 Penn Plaza, 360 West 31st Street, 7th floor, New York, NY 10001
1 shared publication - Michael Paquette
Staff Engineer, Langan Engineering and Environmental Services, 21 Penn Plaza, 360 West 31st Street, 7th floor, New York, NY 10001
1 shared publication - Saul S. Shapiro
Langan Engineering, Environmental, Surveying, and Landscape Architecture
1 shared publication
Latest Publications
- 17 March 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 1597-1607
Removable Compressive Load Distributive Strand Anchors: Case History and Lessons Learned
Removable compressive and distributive strand anchors were successfully used to anchor portions of the temporary support of excavation for the Hudson Yards development in Manhattan, New York. The removable strand anchors were implemented in lieu of conventional anchors to allow future excavation for a cut-and-cover tunnel and caissons. This paper describes the principles of removable compressive and distributive anchors, the installation and testing methods typically used, and the de-tensioning and removal procedures for the anchors. This paper also discusses lessons learned from the installation, testing, and removal of the anchors at Hudson Yards. The anchors used at Hudson Yards were bonded in bedrock. The findings from this study may prove useful to engineers considering the use of removable compressive and load distributive strand anchors for temporary support of excavation systems.
- 17 March 2015
- Published by American Society of Civil Engineers (ASCE)
- p. 1597-1607
Removable Compressive Load Distributive Strand Anchors: Case History and Lessons Learned
Removable compressive and distributive strand anchors were successfully used to anchor portions of the temporary support of excavation for the Hudson Yards development in Manhattan, New York. The removable strand anchors were implemented in lieu of conventional anchors to allow future excavation for a cut-and-cover tunnel and caissons. This paper describes the principles of removable compressive and distributive anchors, the installation and testing methods typically used, and the de-tensioning and removal procedures for the anchors. This paper also discusses lessons learned from the installation, testing, and removal of the anchors at Hudson Yards. The anchors used at Hudson Yards were bonded in bedrock. The findings from this study may prove useful to engineers considering the use of removable compressive and load distributive strand anchors for temporary support of excavation systems.
- 25 February 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 353-362
Comparisons of Data from a Complex-Impedance Measuring Instrument and Conventional Compaction Control Tests
This paper describes the results from a comprehensive evaluation of a relatively new non-nuclear method for compaction control. The device utilized in this study is a complex-impedance measuring instrument (CIMI), more commonly known by its manufacturer's trade name: the "Electrical Density Gauge" (EDG). In its current form, the CIMI device uses a series of electrical measurements in conjunction with calibrated soil models to infer in situ soil unit weight and moisture content. Two approaches currently exist for building soil models with a CIMI: the first is the ASTM-approved method of calibration with in situ measurements of unit weight and moisture content provided by the nuclear density gauge (NDG), sand cone, or other similar type of in situ test, and the second is calibration with large "Proctor-type" mold tests in a controlled laboratory environment. In this study, the two calibration methods were evaluated using NDG tests that were conducted in a large rigid box in the field (to simulate field compaction conditions), and large "Proctor-type" mold tests that were conducted in a lab-controlled environment. In order to evaluate the accuracy of both calibration methods, drive cylinder tests and sand cone tests were conducted at the same locations as the CIMI and NDG tests for comparison purposes. The findings from this study are useful for engineers that may be considering the use of CIMI technology for compaction control.
- 25 February 2013
- Published by American Society of Civil Engineers (ASCE)
- p. 353-362
Comparisons of Data from a Complex-Impedance Measuring Instrument and Conventional Compaction Control Tests
This paper describes the results from a comprehensive evaluation of a relatively new non-nuclear method for compaction control. The device utilized in this study is a complex-impedance measuring instrument (CIMI), more commonly known by its manufacturer's trade name: the "Electrical Density Gauge" (EDG). In its current form, the CIMI device uses a series of electrical measurements in conjunction with calibrated soil models to infer in situ soil unit weight and moisture content. Two approaches currently exist for building soil models with a CIMI: the first is the ASTM-approved method of calibration with in situ measurements of unit weight and moisture content provided by the nuclear density gauge (NDG), sand cone, or other similar type of in situ test, and the second is calibration with large "Proctor-type" mold tests in a controlled laboratory environment. In this study, the two calibration methods were evaluated using NDG tests that were conducted in a large rigid box in the field (to simulate field compaction conditions), and large "Proctor-type" mold tests that were conducted in a lab-controlled environment. In order to evaluate the accuracy of both calibration methods, drive cylinder tests and sand cone tests were conducted at the same locations as the CIMI and NDG tests for comparison purposes. The findings from this study are useful for engineers that may be considering the use of CIMI technology for compaction control.