Shuping Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuping Li has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Cuimei Li
The School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
1 shared publication - Gislain Lipeme Kouyi
INSA Lyon, DEEP, UR7429, Villeurbanne, 69621, France
1 shared publication - Haiyi Zhou
National Engineering Research Center of Protected Agriculture, Tongji University, Shanghai 200092, China
1 shared publication Hao Wang
China Institute of Water Resources and Hydropower Research, Beijing 100044, China; and Department of Environmental Science and Engineering, Suzhou University of Science and Technology, binhe road 1701#, Suzhou, China, 215011
1 shared publicationHengliang Zhang
College of Environmental Science and Engineering, Tongji University
1 shared publication- Hexiang Yan
College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
1 shared publication
Latest Publications
- Open Access
Comparative Regression Modeling of Sewer and Stormwater Pipe Lengths and Manhole Counts: Cross-Validated Performance and Sensitivity Analysis
Existing residential communities may have readily available basic property characteristics but incomplete drainage-asset inventories, limiting record completeness checks and prioritization of field verification. This study compared multiple linear regression (MLR), support vector regression (SVR), and random forest regression (RFR) for estimating existing total sanitary sewer length (m), total stormwater pipeline length (m), sewage manhole count, and stormwater manhole count in 120 Shanghai communities. Models were evaluated using shuffled 10-fold cross-validation and pooled out-of-fold predictions, with preprocessing confined to training folds. Metric uncertainty was estimated from 10,000 paired case-bootstrap resamples, and pairwise differences were tested using randomization tests with Holm-adjusted p values. In the primary seed-42 partition, RFR had the lowest sanitary sewer RMSE (939.47 m), but pairwise differences were not statistically supported and the ranking was partition sensitive. MLR had the lowest RMSE for the other three targets and ranked first for all three in all 10 repeated partitions. Replacing observed sanitary sewer length with nested cross-fitted estimates increased stormwater pipeline RMSE by 99.9%, while manhole results depended on the error metric. The models support only provisional inventory screening and record-review prioritization; they do not provide design quantities and require independent validation before wider use.
Open AccessComparative Regression Modeling of Sewer and Stormwater Pipe Lengths and Manhole Counts: Cross-Validated Performance and Sensitivity Analysis
Existing residential communities may have readily available basic property characteristics but incomplete drainage-asset inventories, limiting record completeness checks and prioritization of field verification. This study compared multiple linear regression (MLR), support vector regression (SVR), and random forest regression (RFR) for estimating existing total sanitary sewer length (m), total stormwater pipeline length (m), sewage manhole count, and stormwater manhole count in 120 Shanghai communities. Models were evaluated using shuffled 10-fold cross-validation and pooled out-of-fold predictions, with preprocessing confined to training folds. Metric uncertainty was estimated from 10,000 paired case-bootstrap resamples, and pairwise differences were tested using randomization tests with Holm-adjusted p values. In the primary seed-42 partition, RFR had the lowest sanitary sewer RMSE (939.47 m), but pairwise differences were not statistically supported and the ranking was partition sensitive. MLR had the lowest RMSE for the other three targets and ranked first for all three in all 10 repeated partitions. Replacing observed sanitary sewer length with nested cross-fitted estimates increased stormwater pipeline RMSE by 99.9%, while manhole results depended on the error metric. The models support only provisional inventory screening and record-review prioritization; they do not provide design quantities and require independent validation before wider use.
- Open Access
- 31 July 2026
- Published by Frontiers Media SA in Frontiers in Water
- Vol. 8, 1893590
Lag-aware LSTM forecasting of 5-minute stormwater inflow in a sponge city community: a cross-correlation-driven feature framework
Community-scale sponge city retention tanks need accurate short-term inflow forecasts. The forecasts support automated pump scheduling and overflow prevention. Most existing data-driven models were built for natural catchments or city-scale combined sewers. Community-scale sites differ. They show persistent dry-weather baseflow and compound detention from distributed low-impact development (LID) facilities. These features limit how well existing frameworks transfer. This study builds a lightweight, lag-aware framework for 5 min-ahead inflow prediction. A cross-correlation function (CCF) analysis extracts one physically interpretable rain-fall–inflow lag. The lag is combined with autoregressive inflow terms, recent rainfall, and multi-scale cumulative rainfall to form a 12-feature input. The framework was tested on 100 days of 5-min rainfall and inflow records from a 51484.6 m 2 LID-equipped residential community in City P, China. The site includes permeable pavements, depressed green spaces, and bioretention cells. The CCF identified a representative rainfall–inflow response timescale of about 70 min, consistent with the compound detention behavior of the LID facilities. Five models were compared under the same features. A dual-layer LSTM reached the highest test-set NSE of 0.7436. A single-layer LSTM (0.7403), SVR (0.7398), and dual-layer GRU (0.7348) fell within a 1% NSE band. A Random Forest baseline reached only 0.6724. The NSE ceiling reflects the baseflow-dominated variance of the inflow series, not a weakness of the models. The ablation study shows that the CCF-derived lag feature gives the largest single rainfall-related accuracy gain. Forecasts are near-unbiased at the 5 min step. The compact feature space lets operators swap the model to match on-site computing limits, which makes the framework easy to deploy at other sponge city communities.
- 31 July 2026
- Published by Frontiers Media SA in Frontiers in Water
- Vol. 8, 1893590
Open AccessLag-aware LSTM forecasting of 5-minute stormwater inflow in a sponge city community: a cross-correlation-driven feature framework
Community-scale sponge city retention tanks need accurate short-term inflow forecasts. The forecasts support automated pump scheduling and overflow prevention. Most existing data-driven models were built for natural catchments or city-scale combined sewers. Community-scale sites differ. They show persistent dry-weather baseflow and compound detention from distributed low-impact development (LID) facilities. These features limit how well existing frameworks transfer. This study builds a lightweight, lag-aware framework for 5 min-ahead inflow prediction. A cross-correlation function (CCF) analysis extracts one physically interpretable rain-fall–inflow lag. The lag is combined with autoregressive inflow terms, recent rainfall, and multi-scale cumulative rainfall to form a 12-feature input. The framework was tested on 100 days of 5-min rainfall and inflow records from a 51484.6 m 2 LID-equipped residential community in City P, China. The site includes permeable pavements, depressed green spaces, and bioretention cells. The CCF identified a representative rainfall–inflow response timescale of about 70 min, consistent with the compound detention behavior of the LID facilities. Five models were compared under the same features. A dual-layer LSTM reached the highest test-set NSE of 0.7436. A single-layer LSTM (0.7403), SVR (0.7398), and dual-layer GRU (0.7348) fell within a 1% NSE band. A Random Forest baseline reached only 0.6724. The NSE ceiling reflects the baseflow-dominated variance of the inflow series, not a weakness of the models. The ablation study shows that the CCF-derived lag feature gives the largest single rainfall-related accuracy gain. Forecasts are near-unbiased at the 5 min step. The compact feature space lets operators swap the model to match on-site computing limits, which makes the framework easy to deploy at other sponge city communities.
- Open Access
Urban Flood Risk Assessment Based on DEMATEL-ANP Hybrid Fuzzy Evaluation and Hydrodynamic Model
The escalating severity of urban flood issues endangers both civilian security and property safety. Urban flood risk assessment delivers critical guidance for urban flood risk management and flood-prevention planning. This study introduces a hybrid methodological model for assessing urban flood risks that integrate scenario simulation and index system methodologies. A hydraulic model was established to simulate water accumulation scenarios in urban areas, thereby acquiring requisite data for the index system. The causal dependencies among indexes were identified through the Decision-Making Trial and Evaluation Laboratory (DEMATEL) method, while indexes weights were obtained by hybridized Analytic Network Process (ANP) method. Finally, a fuzzy comprehensive evaluation (FCE) method is applied to complete the risk assessment. The results showed that the area proportions corresponding to the five risk levels (low risk, relatively low risk, moderate risk, relatively high risk, and high risk) in the study area are 68.98%, 22.75%, 0.86%, 0.10%, and 7.31%, respectively. By using the raster calculation method, the model evaluation can achieve a 10 m × 10 m spatial resolution, which is suitable for fine simulation at small scales within the city, and provides specific high-risk locations for flood-prevention planning.
Open AccessUrban Flood Risk Assessment Based on DEMATEL-ANP Hybrid Fuzzy Evaluation and Hydrodynamic Model
The escalating severity of urban flood issues endangers both civilian security and property safety. Urban flood risk assessment delivers critical guidance for urban flood risk management and flood-prevention planning. This study introduces a hybrid methodological model for assessing urban flood risks that integrate scenario simulation and index system methodologies. A hydraulic model was established to simulate water accumulation scenarios in urban areas, thereby acquiring requisite data for the index system. The causal dependencies among indexes were identified through the Decision-Making Trial and Evaluation Laboratory (DEMATEL) method, while indexes weights were obtained by hybridized Analytic Network Process (ANP) method. Finally, a fuzzy comprehensive evaluation (FCE) method is applied to complete the risk assessment. The results showed that the area proportions corresponding to the five risk levels (low risk, relatively low risk, moderate risk, relatively high risk, and high risk) in the study area are 68.98%, 22.75%, 0.86%, 0.10%, and 7.31%, respectively. By using the raster calculation method, the model evaluation can achieve a 10 m × 10 m spatial resolution, which is suitable for fine simulation at small scales within the city, and provides specific high-risk locations for flood-prevention planning.
- Open Access
- 7 July 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (14) , 8314
Using a Novel Algorithm Based on the Random Vector Functional Link Network and Multi-Verse Optimizer to Forecast Effluent Quality
The treatment of wastewater is a complicated biological reaction process. Reliable effluent prediction is critical in the scientific management of water treatment plants. This research proposes a soft sensor design strategy to address the issues above, Multi-Verse Optimizer (MVO)-based random vector functional link network (MVO-RVFL). The proposed approach is utilized to anticipate real-time effluent data obtained from the Benchmark Simulation Model 1 (BSM1). The results of the experiments demonstrate that the MVO methodology can successfully find the optimum input-hidden weights and hidden biases of the RVFL model while outperforming the original RVFL and other typical machine learning approaches in all types of influent datasets. In the situation of significant water quality variations, the use of the fusion process for model development was also investigated. The experimental results demonstrate that incorporating prior knowledge can effectively improve the model’s ability to cope with unexpected situations.
- 7 July 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (14) , 8314
Open AccessUsing a Novel Algorithm Based on the Random Vector Functional Link Network and Multi-Verse Optimizer to Forecast Effluent Quality
The treatment of wastewater is a complicated biological reaction process. Reliable effluent prediction is critical in the scientific management of water treatment plants. This research proposes a soft sensor design strategy to address the issues above, Multi-Verse Optimizer (MVO)-based random vector functional link network (MVO-RVFL). The proposed approach is utilized to anticipate real-time effluent data obtained from the Benchmark Simulation Model 1 (BSM1). The results of the experiments demonstrate that the MVO methodology can successfully find the optimum input-hidden weights and hidden biases of the RVFL model while outperforming the original RVFL and other typical machine learning approaches in all types of influent datasets. In the situation of significant water quality variations, the use of the fusion process for model development was also investigated. The experimental results demonstrate that incorporating prior knowledge can effectively improve the model’s ability to cope with unexpected situations.
- 4 December 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 352-362
A CFD-Based Level Sensor Location Optimization Method for Overflow Discharge Estimation in CSOs
Assessment of overflow discharge of combined sewer overflows (CSOs) is of great importance for pollution control in combined sewer system (CSS) since in which many pollutants is often contained during the wet weather. The relationship between water level of CSOs chamber is often used to estimate the discharge. However, it is difficult to accurately estimate the overflow discharge with limit level sensors due to the complex flow condition. A computational fluid dynamics (CFD) based method which is capable to determine the most suitable location for water level sensor is presented, aiming to improve the monitoring accuracy of overflow discharge by optimizing the locations with limit sensors. The results show that the proposed method can quantitatively find the optimized location of the sensor, coupling with the global uncertainty estimation. Therefore, the proposed method can provide more accurate monitoring information for assessing the CSOs impact on receiving water bodies, rehabilitation measures, and real time control (RTC) management.
- 4 December 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 352-362
A CFD-Based Level Sensor Location Optimization Method for Overflow Discharge Estimation in CSOs
Assessment of overflow discharge of combined sewer overflows (CSOs) is of great importance for pollution control in combined sewer system (CSS) since in which many pollutants is often contained during the wet weather. The relationship between water level of CSOs chamber is often used to estimate the discharge. However, it is difficult to accurately estimate the overflow discharge with limit level sensors due to the complex flow condition. A computational fluid dynamics (CFD) based method which is capable to determine the most suitable location for water level sensor is presented, aiming to improve the monitoring accuracy of overflow discharge by optimizing the locations with limit sensors. The results show that the proposed method can quantitatively find the optimized location of the sensor, coupling with the global uncertainty estimation. Therefore, the proposed method can provide more accurate monitoring information for assessing the CSOs impact on receiving water bodies, rehabilitation measures, and real time control (RTC) management.
- 8 December 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 320-333
Analysis of Chinese Pipe Burst Events Reported by Web Media in 2013
In order to find out characteristics of pipe bursts, 190 burst events reported by domestic web news in 2013 were collected and analyzed. The statistical analysis results showed that bursts often occurred in months when the weather changed or was bitterly cold. Bursts occurred most frequently in the time period of 5:00-17:00. Generally, main roads, intersections and construction sites were more likely to become events locations. Heavy trucks passing, aging pipes, barbaric construction and changing weather were factors affecting pipe bursts. The diameter of burst pipes concentrated in DN200~DN600, DN800 and DN1000~DN1200. The probability of bursts might increase when pipes age between 20~40 years. The relevant department dealt with bursts in time, and about 70% of the burst problems could be solved in 24 hours.
- 8 December 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 320-333
Analysis of Chinese Pipe Burst Events Reported by Web Media in 2013
In order to find out characteristics of pipe bursts, 190 burst events reported by domestic web news in 2013 were collected and analyzed. The statistical analysis results showed that bursts often occurred in months when the weather changed or was bitterly cold. Bursts occurred most frequently in the time period of 5:00-17:00. Generally, main roads, intersections and construction sites were more likely to become events locations. Heavy trucks passing, aging pipes, barbaric construction and changing weather were factors affecting pipe bursts. The diameter of burst pipes concentrated in DN200~DN600, DN800 and DN1000~DN1200. The probability of bursts might increase when pipes age between 20~40 years. The relevant department dealt with bursts in time, and about 70% of the burst problems could be solved in 24 hours.
- 19 May 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 4514-4522
The Comparison of the Value Engineering Method and Hydraulic Method on Water Distribution Systems Performance Evaluation
Value engineering is an evaluation method to assess the matching degree on performance and its cost of water distribution systems from the point of function achievement characteristics, which had been published from 2006 in some journal. The scientific of Value engineering method had been confirmed by a large number of facts in other applications, but in the evaluation of water distribution systems is still a new topic. The correctness, accuracy of its evaluation results is very crucial taking into account the complexity of water distribution network; therefore, we should use another mature method for checking its correctness and accuracy. Hydraulic evaluation method of water distribution systems was built on the basis of hydraulic calculation; theory is relatively mature, which is one of achiever way of water distribution systems functional assessment. Therefore, it can be used to check the conclusions of value engineering evaluation. In this paper, hydraulic evaluation methods include two contents: first is the overall performance evaluation by using total performance index of water network, which includes selection of state variables associated with different evaluation system, rendering performance curve for the calibration standard service level performance element variation of state variables, select inductive element level performance evaluation function to expand the pipe network by the performance index. Second, component's performance evaluation which is based on the optimization calculation of water distribution systems, and use the hydraulic parameters ad the basic evaluation indicators. Last, pointed out the advantages and disadvantages of the hydraulic evaluation method and value engineering method by compare and analyze their respective results, drew the conclusion that value engineering method is better than hydraulic evaluation method.
- 19 May 2011
- Published by American Society of Civil Engineers (ASCE)
- p. 4514-4522
The Comparison of the Value Engineering Method and Hydraulic Method on Water Distribution Systems Performance Evaluation
Value engineering is an evaluation method to assess the matching degree on performance and its cost of water distribution systems from the point of function achievement characteristics, which had been published from 2006 in some journal. The scientific of Value engineering method had been confirmed by a large number of facts in other applications, but in the evaluation of water distribution systems is still a new topic. The correctness, accuracy of its evaluation results is very crucial taking into account the complexity of water distribution network; therefore, we should use another mature method for checking its correctness and accuracy. Hydraulic evaluation method of water distribution systems was built on the basis of hydraulic calculation; theory is relatively mature, which is one of achiever way of water distribution systems functional assessment. Therefore, it can be used to check the conclusions of value engineering evaluation. In this paper, hydraulic evaluation methods include two contents: first is the overall performance evaluation by using total performance index of water network, which includes selection of state variables associated with different evaluation system, rendering performance curve for the calibration standard service level performance element variation of state variables, select inductive element level performance evaluation function to expand the pipe network by the performance index. Second, component's performance evaluation which is based on the optimization calculation of water distribution systems, and use the hydraulic parameters ad the basic evaluation indicators. Last, pointed out the advantages and disadvantages of the hydraulic evaluation method and value engineering method by compare and analyze their respective results, drew the conclusion that value engineering method is better than hydraulic evaluation method.