FLFrank Lüdicke

Frank Lüdicke

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Frank Lüdicke has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Rolf Weitkunat

    Philip Morris International R&D, Philip Morris Products S.A., Neuchâtel, Switzerland

    7 shared publications
  • Christelle Haziza

    Philip Morris International R&D, Philip Morris Products S.A., Neuchâtel, Switzerland

    5 shared publications
  • Patrick Picavet

    Philip Morris International R&D, Philip Morris Products S.A., Neuchâtel, Switzerland

    5 shared publications
  • Gizelle Baker

    Philip Morris International R&D, Philip Morris Products S.A., Neuchâtel, Switzerland

    4 shared publications
  • John Magnette

    Philip Morris Products S.A., Research & Development, Neuchâtel, Switzerland

    3 shared publications
  • Nicola Lama

    Philip Morris Products S.A., PMI Research and Development, Neuchâtel, Switzerland

    3 shared publications

Latest Publications

  • Open Access

    Effects of Switching to a Heat-Not-Burn Tobacco Product on Biologically Relevant Biomarkers to Assess a Candidate Modified Risk Tobacco Product: A Randomized Trial

    by Frank Lüdicke, S. Michael Ansari, Nicola Lama, Nicolas Blanc, Marija Bosilkovska, Andrea Donelli, Patrick Picavet, Gizelle Baker, Christelle Haziza, Manuel Peitsch, et al.

    Background: Cigarette smoking increases the risk of chronic diseases; heating instead of burning tobacco can lower these risks, contributing to tobacco harm reduction. This study (with 984 adult American smokers) examined whether favorable changes occur in 8 co-primary endpoints (HDL-C, WBC, FEV1%pred, COHb, Total NNAL, sICAM-1, 11-DTX-B2, 8-epi-PGF2α) indicative of biological and functional effects when cigarette smokers switch to the heat-not-burn Tobacco Heating System 2.2 (THS). Additionally, these biomarkers of exposure (BoExp) were quantified: MHBMA, 3-HPMA, Total NNN, CEMA, 3-OH-B[a]P, HMPMA, Total 1-OHP, NEQ, and CO exhaled. Methods: Participants were randomized to continued smoking of their preferred cigarette brand (n = 496) or to using THS (IQOS brand; n = 488) for 6 months. THS has a maximum heating temperature of 350°C, delivering 1.21 mg nicotine/stick and 3.94 mg glycerin/stick under the Health Canada Intense smoking regimen. Results: The main outcome was a favorable change 6 months after baseline, with statistically significant improvements in 5 of 8 biomarkers of effect (HDL-C, WBC, FEV1%pred, COHb, Total NNAL) when smokers switched to THS compared with those who continued to smoke cigarettes. Likewise, BoExp were markedly reduced. Conclusions: All endpoints showed favorable changes in the same direction as with smoking cessation and improved biological effects were observed in smokers who predominantly used THS compared with continued cigarette smoking, with similar nicotine levels in both groups. Impact: Improvements in 5 of 8 biomarkers of effect are supportive of the research hypothesis, suggestive of disease risk reduction potential for smokers switching to THS instead of continuing to smoke cigarettes.


  • Open Access

    Development and validation of a new instrument to measure perceived risks associated with the use of tobacco and nicotine-containing products

    by Stefan Cano, Christelle Chrea, Thomas Salzberger, Thomas Alfieri, Gerard Emilien, Nelly Mainy, Antonio Ramazzotti, Frank Lüdicke, Rolf Weitkunat

    Making tobacco products associated with lower risks available to smokers who would otherwise continue smoking is recognized as an important strategy towards addressing smoking-related harm. Predicting use behavior is an important major component of product risk assessment. In this context, risk perception is a possible factor driving tobacco product uptake and use. As prior to market launch real-world actual product use cannot be observed, assessing risk perception can provide predictive information. Considering the lack of suitable validated self-report instruments, the development of a new instrument was undertaken to quantify perceived risks of tobacco and nicotine-containing products by adult smokers, former smokers and never-smokers. Initial items were constructed based on a literature review, focus groups and expert opinion. Data for scale formation and assessment were obtained through two successive US-based web surveys (n = 2020 and 1640 completers, respectively). Psychometric evaluation was based on Rasch Measurement Theory and Classical Test Theory. Psychometric evaluation supported the formation of an 18-item Perceived Health Risk scale and a 7-item Perceived Addiction Risk scale: item response option thresholds were ordered correctly for all items; item locations in each scale were spread out (coverage range 75–87%); scale reliability was supported by high person separation indices > 0.93, Cronbach’s alpha > 0.98 and Corrected Item-Total Correlations > 0.88; and no differential item functioning was present. Construct validity evaluations met expectations through inter-scale correlations and findings from known-group comparisons. The Perceived Risk Instrument is a psychometrically robust instrument applicable for general and personal risk perception measurement, for use in different types of products (including cigarettes, nicotine replacement therapy, potential Modified Risk Tobacco Products), and for different smoking status groups (i.e., current smokers with and without intention to quit, former smokers, never smokers).


  • Open Access

    Modeling the Population Health Impact of Introducing a Modified Risk Tobacco Product into the U.S. Market

    by Smilja Djurdjevic, Peter N. Lee, Rolf Weitkunat, Zheng Sponsiello-Wang, Frank Lüdicke, Gizelle Baker

    Philip Morris International (PMI) has developed the Population Health Impact Model (PHIM) to quantify, in the absence of epidemiological data, the effects of marketing a candidate modified risk tobacco product (cMRTP) on the public health of a whole population. Various simulations were performed to understand the harm reduction impact on the U.S. population over a 20-year period under various scenarios. The overall reduction in smoking attributable deaths (SAD) over the 20-year period was estimated as 934,947 if smoking completely went away and between 516,944 and 780,433 if cMRTP use completely replaces smoking. The reduction in SADs was estimated as 172,458 for the World Health Organization (WHO) 2025 Target and between 70,274 and 90,155 for the gradual cMRTP uptake. Combining the scenarios (WHO 2025 Target and cMRTP uptake), the reductions were between 256,453 and 268,796, depending on the cMRTP relative exposure. These results show how a cMRTP can reduce overall population harm additionally to existing tobacco control efforts.


  • Open Access

    Evaluation of Nicotine Pharmacokinetics and Subjective Effects following Use of a Novel Nicotine Delivery System

    by Axel Teichert, Patrick Brossard, Loyse Felber Medlin, Larissa Sandalic, Mikael Franzon, Chris Wynne, Murray Laugesen, Frank Lüdicke

    Novel nicotine delivery systems represent an evolving part of the tobacco harm reduction strategy. The pharmacokinetic (PK) profile of nicotine delivered by P3L, a pulmonary nicotine delivery system, and its effects on smoking urges and craving relief in relation to Nicorette inhalator were evaluated. This open-label, ascending nicotine levels study was conducted in 16 healthy smokers. Three different nicotine delivery levels, 50, 80, and 150 µg/puff, delivered by the P3L system were evaluated consecutively on different days after the use of the Nicorette inhalator. Venous nicotine PK, subjective effects, and tolerability were assessed. Geometric least-squares means for maximum plasma nicotine concentration (Cmax), generated by the mixed-effect model for exposure comparison, were 9.7, 11.2, and 9.8 ng/mL for the 50, 80, and 150 µg/puff P3L variants, respectively, compared to 6.1 ng/mL after Nicorette inhalator use. Median time from product use start to Cmax was 7.0 minutes for all P3L, compared to 30.0 minutes for the Nicorette inhalator. Craving reduction was slightly faster than with the Nicorette inhalator as assessed with the visual analog scale craving score. The mean Questionnaire of Smoking Urges -brief total scores did not differ for both products. P3L was well tolerated. At all three nicotine levels tested, the inhalation of the nicotine lactate aerosol delivered with the P3L provided plasma nicotine concentrations higher and faster compared to the Nicorette inhalator. The plasma nicotine concentration–time profile supports a pulmonary route of absorption for P3L compared to the oromucosal absorption of the Nicorette inhalator. The combination of nicotine and lactic acid with the P3L device shows potential over existing nicotine delivery systems by delivering nicotine with kinetics close to published data on conventional cigarettes and without exogenous carrier substances as used in current electronic nicotine delivery systems. Altogether, the PK profile, subjective effects, and safety profile obtained in this study suggest P3L is an innovative nicotine delivery product that will be acceptable to adult smokers as an alternative to cigarettes.


  • Open Access

    Effects of Switching to the Menthol Tobacco Heating System 2.2, Smoking Abstinence, or Continued Cigarette Smoking on Clinically Relevant Risk Markers: A Randomized, Controlled, Open-Label, Multicenter Study in Sequential Confinement and Ambulatory Settings (Part 2)

    by Frank Lüdicke, Patrick Picavet, Gizelle Baker, Christelle Haziza, Valerie Poux, Nicola Lama, Rolf Weitkunat

    Modified-risk tobacco products are expected to reduce exposure to harmful and potentially harmful constituents of cigarette smoke, and ultimately reduce the health burden of smoking-related diseases. Clinically relevant risk markers of smoking-related diseases inform about the risk profile of new tobacco products in the absence of in-market epidemiological data. The menthol Tobacco Heating System 2.2 (mTHS) is a modified-risk tobacco product in development as an alternative to cigarettes (conventional cigarettes [CCs]). In this parallel-group study, Japanese adult smokers (23–65 years; ≥10 mCCs/day) were randomized to mTHS, menthol CCs (mCC), or smoking abstinence (SA) for 5 days in confinement and 85 days in ambulatory settings. Endpoints included biomarkers of exposure to harmful and potentially harmful constituents and clinically relevant risk markers of smoking-related diseases. One-hundred and sixty participants were randomized to the mTHS (n = 78), mCC (n = 42), and SA (n = 40) groups. Switching to the mTHS was associated with reductions in biomarkers of exposure compared with continuing mCCs. Reductions in 8-epi-prostaglandin F2α (biomarker of oxidative stress), 11-dehydro-thromboxane B2 (biomarker of platelet activation), soluble intracellular adhesion molecule-1 (biomarker of endothelial function), and an increase in high-density lipoprotein cholesterol (biomarker of lipid metabolism) and forced expiratory volume in 1 second (biomarker of lung function) occurred in the mTHS group compared with the mCC group. The changes in the mTHS group approached those in the SA group. Switching from mCCs to mTHS was associated with improvements in clinically relevant risk markers linked to mechanistic pathways involved in smoking-related diseases. In this three-way randomized study, switching from menthol cigarettes to mTHS for 5 days in confinement and 85 days in ambulatory settings was associated with reductions in biomarkers of exposure to cigarette smoke, and changes were observed in clinically relevant biomarkers of oxidative stress (8-epi-prostaglandin F2α), platelet activity (11-dehydro-thromboxane B2), endothelial function (soluble intracellular adhesion molecule-1), lipid metabolism (high-density lipoprotein cholesterol) and lung function (forced expiratory volume in 1 second), similar to the SA group. The results suggest that switching to the mTHS has the potential to reduce the adverse health effects of conventional cigarettes.


  • Open Access

    Effects of Switching to the Tobacco Heating System 2.2 Menthol, Smoking Abstinence, or Continued Cigarette Smoking on Biomarkers of Exposure: A Randomized, Controlled, Open-Label, Multicenter Study in Sequential Confinement and Ambulatory Settings (Part 1)

    by Frank Lüdicke, Patrick Picavet, Gizelle Baker, Christelle Haziza, Valerie Poux, Nicola Lama, Rolf Weitkunat

    The menthol Tobacco Heating System 2.2 (mTHS) is a newly developed candidate modified-risk tobacco product intended to reduce exposure to the harmful and potentially harmful constituents (HPHCs) of conventional cigarette (CC) smoke. This study examined the impact of switching to mTHS on biomarkers of exposure to HPHCs relative to menthol CCs (mCCs) and smoking abstinence (SA). In this three-arm, parallel-group study, 160 Japanese adult smokers (23–65 years; smoking ≥10 mCCs per day) were randomized to mTHS (n = 78), mCC (n = 42), or SA (n = 40) for 5 days in confinement and 85 days in ambulatory settings. Endpoints included biomarkers of exposure to HPHCs, human puffing topography, safety, and subjective effects of smoking measures. After 5 days of product use, the concentrations of carboxyhemoglobin, 3-hydroxypropylmercapturic acid, monohydroxybutenyl mercapturic acid, and S-phenylmercapturic acid were 55%, 49%, 87%, and 89% lower (p < .001), respectively, in the mTHS group than in the mCC group. Other biomarkers of exposure (measured as secondary endpoints) were 50%–94% lower in the mTHS group than in the mCC group on day 5. These reductions in the mTHS group were maintained at day 90, similar to the SA group. Switching to mTHS was associated with changes in human puffing topography (shorter puff intervals and more frequent puffs). The urge-to-smoke and smoking satisfaction levels on day 90 were similar in the mTHS and the mCC groups. Switching from mCCs to mTHS significantly reduced exposure to HPHCs relative to continuing smoking mCCs with concentrations similar to those observed following SA in Japanese adult smokers. This randomized study compared the impact of switching to a modified-risk tobacco product candidate mTHS on biomarkers of exposure to HPHCs of cigarette smoke relative to continuing smoking cigarettes or abstaining from smoking in sequential confinement and ambulatory settings. The study showed that switching to mTHS was associated with significant biomarker reductions within 5 days in confinement, these reductions being maintained throughout the ambulatory setting up to day 90. The results provide evidence that switching to mTHS reduces real-life exposure to HPHCs in adult smokers.


  • Open Access

    Reduced Exposure to Harmful and Potentially Harmful Smoke Constituents With the Tobacco Heating System 2.1

    by Frank Lüdicke, Gizelle Baker, John Magnette, Patrick Picavet, Rolf Weitkunat

    Heating rather than burning tobacco reduces levels of harmful and potentially harmful constituents, and consumer products using this approach aim to reduce exposure to tobacco toxicants. The Tobacco Heating System (THS) version 2.1 has been enhanced from earlier prototypes with an improved heat control and sensorial experience and thereby user acceptance. Exposure measurements are required to determine whether it may be possible to reduce the individual health risk compared to smoking combustible cigarettes (CCs). This controlled clinical study randomly assigned 40 smokers to either a group continuing to use of their own CC brand (n = 20) or a group switching to THS 2.1 (n = 20) for 5 days. Biomarkers of exposure were measured at baseline and on day 1 through day 5. Product consumption, Human Puffing Topography, the occurrence of adverse events, and an assessment of subjective effects, such as smoking satisfaction and enjoyment of respiratory tract sensations, were also determined. The group of smokers who switched to THS 2.1 adapted their puffing behavior initially through longer puff duration and more puffs. During the duration of the study, total puff volume returned to baseline levels and the mean daily product consumption increased but with similar nicotine exposure compared to baseline CC use. Biomarkers of exposure to tobacco smoke toxicants which inform product risk assessment were significantly reduced with THS use compared to the CC group. THS 2.1 users experienced less reinforcing effects with THS 2.1 than with their own cigarette brand. THS 2.1 is a promising alternative to smoking CCs. Notwithstanding possible use adaption through consumption or puffing behavior, the exposure to harmful smoke constituents was markedly reduced with the new heated tobacco platform. Exposure markers to harmful and potentially harmful smoke constituents were lowered with the THS 2.1. Heating tobacco instead of burning can offer a potentially lower risk of delivering nicotine compared to CCs.


  • Open Access

    Evaluation of Biomarkers of Exposure in Smokers Switching to a Carbon-Heated Tobacco Product: A Controlled, Randomized, Open-Label 5-Day Exposure Study

    by Frank Lüdicke, Christelle Haziza, Rolf Weitkunat, John Magnette

    Tobacco harm reduction aims to provide reduced risk alternatives to adult smokers who would otherwise continue smoking combustible cigarettes (CCs). This randomized, open-label, three-arm, parallel-group, single-center, short-term confinement study aimed to investigate the effects of exposure to selected harmful and potentially harmful constituents (HPHCs) of cigarette smoke in adult smokers who switched to a carbon-heated tobacco product (CHTP) compared with adult smokers who continued to smoke CCs and those who abstained from smoking for 5 days. Biomarkers of exposure to HPHCs, including nicotine and urinary excretion of mutagenic material, were measured in 24-hour urine and blood samples in 112 male and female Caucasian smokers switching from CCs to the CHTP ad libitum use. Puffing topography was assessed during product use. Switching to the CHTP or smoking abstinence (SA) resulted in marked decreases from baseline to Day 5 in all biomarkers of exposure measured, including carboxyhemoglobin (43% and 55% decrease in the CHTP and SA groups, respectively). The urinary excretion of mutagenic material was also markedly decreased on Day 5 compared with baseline (89% and 87% decrease in the CHTP and SA groups, respectively). No changes in biomarkers of exposure to HPHCs or urinary mutagenic material were observed between baseline and Day 5 in the CC group. Our results provide clear evidence supporting a reduction in the level of exposure to HPHCs of tobacco smoke in smokers who switch to CHTP under controlled conditions, similar to that observed in SA. The reductions observed in biomarkers of exposure to HPHCs of tobacco smoke in this short-term study could potentially also reduce the incidence of cancer, cardiovascular and respiratory diseases in those smokers who switch to a heated tobacco product.


  • Open Access

    Comparison of the Pharmacokinetics of Nicotine Following Single andAd LibitumUse of a Tobacco Heating System or Combustible Cigarettes

    by Patrick Picavet, Christelle Haziza, Nicola Lama, Rolf Weitkunat, Frank Lüdicke

    We aimed to compare the pharmacokinetics of nicotine between the heat-not-burn Tobacco Heating System 2.1 (THS 2.1) and combustible cigarettes (CCs). We also examined whether the subjective urge to smoke was associated with the pharmacokinetics of nicotine. This open-label, randomized, two-period, two-sequence crossover study conducted in 28 healthy smokers assessed the pharmacokinetics of nicotine after single and ad libitum use of the THS 2.1 or CCs. During the 7-day confinement period, blood samples were drawn for pharmacokinetic analysis. Subjective effects related to THS 2.1 or CC use were assessed using the Questionnaire of Smoking Urges (QSU-Brief). The nicotine delivery rate was similar with the THS 2.1 and CCs after single and ad libitum use. The time to the maximum nicotine concentration was 8 minutes after single use of the THS 2.1 and CCs. The time to the peak concentration following ad libitum use was similar between the THS 2.1 and CCs. The maximum plasma nicotine concentration after single use of the THS 2.1 was 8.4ng/mL, 70.3% of that obtained with CCs. A transient reduction from baseline in the urge to smoke of 40% was observed 15 minutes after the single use of both the THS 2.1 and CCs. The mean QSU-Brief total scores following single and ad libitum use were similar for the THS 2.1 and CCs. These results suggest that the THS 2.1 effectively delivers nicotine and achieves similar pharmacokinetic profiles to CCs. The THS 2.1 also reduced the urge to smoke similarly to CCs. Reducing exposure to toxicants and safer delivery of nicotine are among the strategies that may reduce the harm of smoking-related diseases. In the present study, we investigated the pharmacokinetics of nicotine and their effects on the urge to smoke using the THS 2.1. It was developed to replicate the ritual of smoking as closely as possible by providing nicotine in a way that mimics CC smoking, but limits pyrolysis and combustion by heating tobacco at a much lower temperature than CCs (heat-not-burn).


  • Open Access

    A Japanese cross-sectional multicentre study of biomarkers associated with cardiovascular disease in smokers and non-smokers

    by Frank Lüdicke, John Magnette, Gizelle Baker, Rolf Weitkunat

    We performed a cross-sectional, multicentre study in Japan to detect the differences in biomarkers of exposure and cardiovascular biomarkers between smokers and non-smokers. Several clinically relevant cardiovascular biomarkers differed significantly between smokers and non-smokers, including lipid metabolism (high-density lipoprotein cholesterol concentrations – lower in smokers), inflammation (fibrinogen and white blood cell count – both higher in smokers), oxidative stress (8-epi-prostaglandin F2α – higher in smokers) and platelet activation (11-dehydro-thromboxane B2 – higher in smokers) (p ≤ 0.0001). These results provide further evidence showing that cardiovascular biomarkers can discriminate smokers from non-smokers, and could be used to evaluate the risks associated with tobacco products.