Renyang He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Renyang He has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Gongtian Shen
China Special Equipment Inspection and Research Institute, Beijing, China, 100013
1 shared publication - Huaiyun Cui
Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China
1 shared publication - Jinzhong Chen
China Institute of Special Equipment Inspection, Heping Street, Chaoyang District, Beijing, China
1 shared publication - Lin Lu
Institute for Advanced Materials and Technology, University of Science and Technology Beijing, Beijing 100083, China
1 shared publication - Xianyong Qin
China Special Equipment Inspection and Research Institute, Beijing, China, 100013
1 shared publication - Xiaoguang Sun
CRRC Qingdao Sifang Co., Ltd., Qingdao 266111, China
1 shared publication
Latest Publications
- Open Access
Effect of Service Environmental Parameters on Electrochemical Corrosion Behavior of L80 Casing Steel
The corrosion behavior of L80 casing steel was studied in a simulating annulus environment using the electrochemical measurement method, immersion test, and tensile test under a high-temperature and high-pressure H2S/CO2 environment. The partial pressure of CO2 (), the partial pressure of H2S (), water content, and preloading stress remarkably affected the corrosion behavior of L80 steel. The influence of on stress corrosion cracking (SCC) susceptibility has an inflection point of approximately 1.1 MPa. The SCC susceptibility reaches the maximum when the is about 1.1 MPa. The SCC susceptibility has a positive correlation to and water content. The higher water content of the corrosion medium can increase the electrical conductivity of the corrosion medium and promote the corrosion of L80 steel, which can improve the diffusion of hydrogen into steel and promote the SCC of L80 steel. Preloading stress can promote local corrosion, thereby promoting SCC of steel under stress. The dislocation emergence point caused by preloading stress can accelerate the diffusion of hydrogen into steel and increase SCC susceptibility.Open AccessEffect of Service Environmental Parameters on Electrochemical Corrosion Behavior of L80 Casing Steel
The corrosion behavior of L80 casing steel was studied in a simulating annulus environment using the electrochemical measurement method, immersion test, and tensile test under a high-temperature and high-pressure H2S/CO2 environment. The partial pressure of CO2 (), the partial pressure of H2S (), water content, and preloading stress remarkably affected the corrosion behavior of L80 steel. The influence of on stress corrosion cracking (SCC) susceptibility has an inflection point of approximately 1.1 MPa. The SCC susceptibility reaches the maximum when the is about 1.1 MPa. The SCC susceptibility has a positive correlation to and water content. The higher water content of the corrosion medium can increase the electrical conductivity of the corrosion medium and promote the corrosion of L80 steel, which can improve the diffusion of hydrogen into steel and promote the SCC of L80 steel. Preloading stress can promote local corrosion, thereby promoting SCC of steel under stress. The dislocation emergence point caused by preloading stress can accelerate the diffusion of hydrogen into steel and increase SCC susceptibility. - Open Access
- 1 January 2016
- Published by Atlantis Press SARL
SMFF Computation for Probe of Online Magnetic Flux Leakage Detection System with combination of ANSYS and Virtual Work Method
- 1 January 2016
- Published by Atlantis Press SARL
Open AccessSMFF Computation for Probe of Online Magnetic Flux Leakage Detection System with combination of ANSYS and Virtual Work Method
- 15 September 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1631-1642
Research on Fuzzy Comprehensive Evaluation Method of External Corrosion for Buried Pipeline
Considering that it is simplicity to evaluate the external corrosion condition with single factor, the key factors affecting comprehensive evaluation for external corrosion are ascertained based on analyzing the effect of various factors, and which contain soil corrosiveness, stray current, external covering state, cathodic protection effect and pipe corrosion thinning. The model of weight distribution of key factors is established, and the fuzzy comprehensive evaluation system of external corrosion for buried pipeline is established with analytical hierarchy process (AHP) method. The field applications show the method is practicable and reliable.
- 15 September 2009
- Published by American Society of Civil Engineers (ASCE)
- p. 1631-1642
Research on Fuzzy Comprehensive Evaluation Method of External Corrosion for Buried Pipeline
Considering that it is simplicity to evaluate the external corrosion condition with single factor, the key factors affecting comprehensive evaluation for external corrosion are ascertained based on analyzing the effect of various factors, and which contain soil corrosiveness, stray current, external covering state, cathodic protection effect and pipe corrosion thinning. The model of weight distribution of key factors is established, and the fuzzy comprehensive evaluation system of external corrosion for buried pipeline is established with analytical hierarchy process (AHP) method. The field applications show the method is practicable and reliable.