Latest Publications

  • Seismic fragility of traction elevators

    by Keith Porter

    Summary: Second‐generation performance‐based earthquake engineering (PBEE‐2) requires a library of component fragility functions to estimate probabilistic damage to a wide variety of building components. The present work draws on a large body of (mostly) post‐earthquake reconnaissance and (some) post‐earthquake survey observations of traction elevators to create fragility functions useful in PBEE‐2. Two surveys provide detailed observations of 115 representative elevators at 12 hospitals shaken in the 1989 Loma Prieta and 1994 Northridge earthquakes and selected without regard to or foreknowledge of damage. Of these, 55 failed and 60 did not. Approximately half were installed after an important code change of 1972, so one can distinguish the performance of pre‐1973 and post‐1973 elevator construction. They experienced a range of strong motion: 22 with peak ground acceleration (PGA) < 0.25 g, 93 with 0.25 g < PGA < 0.85 g. The hospitals had elevator failure rates as low as 0% and as high as 100%. A third survey describes damage qualitatively for six sites with PGA ≤ 0.25 and per‐site failure rates of 0% to perhaps 30%. Fragility functions are offered where the damage state is the loss of functionality of the elevator. The elevators in these surveys exhibit a median capacity of PGA ≈ 0.35 g with a logarithmic standard deviation of 0.40. Capacity is modestly sensitive to whether the elevator was installed before or after 1973. Using building‐specific intensity measures such as Sa(T1) does not improve the fragility functions. Copyright © 2015 John Wiley & Sons, Ltd.


  • Third Edition Update of FEMA P-154: Rapid Visual Screening for Potential Seismic Hazards

    by B. Lizundia, S. Durphy, M. Griffin, W. Holmes, A. Hortacsu, B. Kehoe, K. Porter, B. Welliver

    FEMA P-154 Rapid Visual Screening of Buildings for Potential Seismic Hazards: A Handbook and the companion publication FEMA P-155: Supporting Documentation provide a methodology for rapid visual screening of buildings for potential seismic hazards. The Handbook provides a “sidewalk survey” approach that enables classification of buildings into two categories: those that appear to be adequately safe and those that may be seismically hazardous and should be evaluated in more detail. The first edition of the Handbook was published in 1988, and it was updated to the second edition in 2002. The methodology has been used extensively throughout the United States by private sector organizations and government agencies to screen buildings, and it has served as a model for similar efforts in other countries. In a project funded by FEMA, the Applied Technology Council updated both FEMA P-154 and FEMA P-155. Major enhancements in the third edition include improvements in the screening form; an added optional more detailed level of screening; updates of the scoring methodology; more refined seismicity regions; new reference guides for vertical and plan irregularities; additional building types; improved consideration of additions, adjacent structures, and retrofits; an optional electronic scoring methodology; new insight into risk; and more detailed discussion on how to run an effective screening program.


  • End-to-End Seismic Risk Management Software

    by Keith Porter, Sid Hellman, Tom McLane, Cathleen Carlisle

    The US Federal Emergency Management Agency and the US Geological Survey have developed a suite of free software for cities, building owners, and others to manage their seismic risk, before, during, and after earthquakes. FEMA's Rapid Observation of Vulnerability and Estimation of Risk (ROVER) is open-source software that operates on a Windows Mobile device (a smartphone) to quickly gather field information about the buildings subjected to seismic risk, before an earthquake occurs. It automates and enhances the FEMA 154 methodology, Rapid Visual Screening of Buildings for Potential Seismic Risk, which has been successfully used on tens of thousands of US buildings, and adapted for use in other countries as well. ROVER also has a free open-source database server component that operates on a Windows or Linux PC to compile the data collected in the field by one or more mobile devices. After an earthquake occurs, ROVER has yet another module that automates and enhances the ATC-20 methodology, Procedures for Post-earthquake Safety Evaluation of Buildings. Using the ROVER ATC-20 module, field safety workers can use a smartphone to carry out the de facto international standard for post-earthquake safety evaluation of buildings. ROVER is linked to two additional seismic risk software packages: HAZUS-MH (NIBS and FEMA 2003) and ShakeCast (Wald et al 2008). After an automated ROVER data export to FEMA's HAZUS-MH Advanced Engineering Building Module, the user can perform scenario or probabilistic seismic risk analysis on the portfolio of buildings examined with ROVER. ROVER's data also interacts with the USGS's ShakeCast software. After an automated ROVER data export to ShakeCast, the user can automate the monitoring of the buildings for damaging earthquakes. When one occurs, ROVER users are automatically notified of shaking and likely damage at each site, including an automated estimate of the likely ATC-20 tag color, which the field user can then verify or update at will. ROVER's server and all its data can be remotely and securely accessed via a Web browser, allowing the field or office user to seek outside expert advice, in real time, about buildings currently under investigation, while the user is still in the field examining the building. All the software—ROVER, HAZUS-MH, and ShakeCast—are free, and can reside securely on the user's own computers. No data need to be shared with anyone else or stored on a computer out of the user's control, although services are available for the user with limited IT resources. This paper focuses on ROVER.


  • Loss Estimates for Large Soft-Story Woodframe Buildings in San Francisco

    by Keith Porter, Kelly Cobeen

    As part of a study for the City of San Francisco entitled Community Action Plan for Seismic Safety (CAPSS), we estimated the consequences of 4 large Bay Area earthquakes for large soft-story woodframe dwellings in San Francisco to inform City risk-management policy. A survey by the City's Department of Building Inspection found 2,800 residential woodframe buildings with 3 or more stories and 5 of more housing units with soft-story conditions. As proxies for these 2,800 unique buildings, four index buildings and three retrofits for each building were designed and analyzed. We developed nonlinear pseudostatic structural models for each building and retrofit. From lab tests and other observations, we created fragility functions for straight-sheathed woodframe walls, lath and plaster interior wall finish, brick veneer, and stucco veneer, and related the observed damage to HAZUS-MH damage states. We estimated the distribution of drift at which buildings would likely receive a red tag under ATC-20 post-earthquake safety inspection procedures. From observations of similar buildings in the San Francisco Marina District after the 1989 Loma Prieta earthquake, we estimated the transient drift associated with collapse. Using a procedure based on the HAZUS Advanced Engineering Building Module, we estimated the economic loss, ATC-20 safety tag color, and collapse probability for each of the 2,800 buildings in each of the 4 scenario earthquakes. Loss estimates were reviewed by an expert panel. We conclude that, in a M7.2 rupture of the San Andreas Fault, between 30 and 50% of the 2,800 buildings would be rendered unsafe to enter or occupy (i.e., they would be red-tagged), and an additional 10 to 30% would collapse. Seismic retrofit costing $11,000 to $17,000 per dwelling unit could reduce red tags to between 6 and 12% of the subject buildings, with 0.3 to 0.7% collapsing—substantial improvements on both counts—though repairs would still be costly.