John Richard Littlewood
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John Richard Littlewood has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- George Karani
Cardiff Metropolitan University
9 shared publications G. Karani
Cardiff Metropolitan University, The Environmental Public Health Research Group
7 shared publications- David Honan
Department of Civil, Structural & Environmental Engineering, Trinity College Dublin, The University of Dublin, D02 PN40 Dublin, Ireland
6 shared publications - Francesco Zaccaro
Cardiff Metropolitan University
6 shared publications - John Garvey
University of Limerick
6 shared publications - Uthayan Thurairajah
Cardiff Metropolitan University
6 shared publications
Latest Publications
- 1 April 2026
- Published by Springer Nature
- p. 187-196
Passive Infrared Thermography for Quality Assurance in Masonry Building Envelopes
- 1 April 2026
- Published by Springer Nature
- p. 187-196
Passive Infrared Thermography for Quality Assurance in Masonry Building Envelopes
- 1 April 2026
- Published by Springer Nature
- p. 157-166
Retrofitting Earth to Air Heat Exchangers to Existing Dwellings for Hybrid Cooling and Enhanced Ventilation
- 1 April 2026
- Published by Springer Nature
- p. 157-166
Retrofitting Earth to Air Heat Exchangers to Existing Dwellings for Hybrid Cooling and Enhanced Ventilation
- 1 April 2026
- Published by Springer Nature
- p. 82-91
Window Opening Behaviours in Irish Primary Schools: Insights from a Pilot Teacher Survey
- 1 April 2026
- Published by Springer Nature
- p. 82-91
Window Opening Behaviours in Irish Primary Schools: Insights from a Pilot Teacher Survey
- 1 April 2026
- Published by Springer Nature
- p. 92-102
Enhancing IAQ in Naturally Ventilated Irish Primary Schools: Research Design and Methodology
- 1 April 2026
- Published by Springer Nature
- p. 92-102
Enhancing IAQ in Naturally Ventilated Irish Primary Schools: Research Design and Methodology
- Open Access
- 17 March 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (6) , 2932
When Are Decentralised Non-Potable Water Systems Environmentally and Financially Viable? Evidence from a Water–Energy–GHG Evaluation of a Healthcare Facility in an Arid City
Rapid urbanisation in arid regions has increased reliance on energy-intensive desalinated water, intensifying environmental and financial pressures on the built environment. Although non-potable water (NPW) reuse is promoted within regional water strategies, empirical validation of decentralised systems at asset scale remains limited. This study applies a greenhouse gas (GHG) intensity metric (kgCO2e/m3) to multi-year operational data from a large healthcare facility in Abu Dhabi. The analysis integrates calibrated water balance records, onsite pumping energy (Scope 2), embedded desalination emissions (Scope 3), and a 20-year discounted cash flow framework. Three configurations are evaluated: a fully desalinated baseline, the observed mixed-supply system, and an optimised NPW configuration. The baseline exhibits an emission intensity of 19.53 kgCO2e/m3. The observed configuration reduces desalinated supply but achieves only marginal decarbonisation (0.40 kgCO2e/m3) due to continued dependence on desalinated make-up water. The optimised configuration reduces outdoor water demand by 36.7% and achieves 10.94 kgCO2e/m3 net decarbonisation while improving life-cycle cost (LCC) performance. The results show that GHG intensity is primarily driven by water source substitution and system configuration rather than volumetric reuse alone, providing asset-level evidence for evaluating decentralised NPW systems in arid-climate buildings.
- 17 March 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (6) , 2932
Open AccessWhen Are Decentralised Non-Potable Water Systems Environmentally and Financially Viable? Evidence from a Water–Energy–GHG Evaluation of a Healthcare Facility in an Arid City
Rapid urbanisation in arid regions has increased reliance on energy-intensive desalinated water, intensifying environmental and financial pressures on the built environment. Although non-potable water (NPW) reuse is promoted within regional water strategies, empirical validation of decentralised systems at asset scale remains limited. This study applies a greenhouse gas (GHG) intensity metric (kgCO2e/m3) to multi-year operational data from a large healthcare facility in Abu Dhabi. The analysis integrates calibrated water balance records, onsite pumping energy (Scope 2), embedded desalination emissions (Scope 3), and a 20-year discounted cash flow framework. Three configurations are evaluated: a fully desalinated baseline, the observed mixed-supply system, and an optimised NPW configuration. The baseline exhibits an emission intensity of 19.53 kgCO2e/m3. The observed configuration reduces desalinated supply but achieves only marginal decarbonisation (0.40 kgCO2e/m3) due to continued dependence on desalinated make-up water. The optimised configuration reduces outdoor water demand by 36.7% and achieves 10.94 kgCO2e/m3 net decarbonisation while improving life-cycle cost (LCC) performance. The results show that GHG intensity is primarily driven by water source substitution and system configuration rather than volumetric reuse alone, providing asset-level evidence for evaluating decentralised NPW systems in arid-climate buildings.
- Open Access
Low-Cost CO2 Sensors: On-Site Performance Evaluation and Co-Location Correction Procedure for Reliable Ventilation Assessments in Schools
Adequate ventilation is essential for maintaining indoor environmental quality in schools, where ventilation standards are often based on an indoor concentration of human-generated carbon dioxide (CO2) above ambient levels. Low-cost non-dispersive infrared (NDIR) CO2 sensors offer a practical solution for ventilation monitoring, yet variability between sensors can compromise accuracy, particularly when applications depend on the determination of precise concentration differences. This study evaluates the performance of twenty-three low-cost CO2 sensors, developing normalisation functions to improve comparability across sensors, introducing an accessible methodology for on-site sensor calibration without the need for laboratory-grade reference equipment. The sensors were co-located for three independent test periods in 2025 representing typical school internal conditions in Ireland. Pre-normalisation analysis showed strong linearity (coefficient of determination (R2) = 0.999) but notable variability, with a mean root mean square error (RMSE) of 18.3 ppm and 0.45% of measurements outside manufacturers stated accuracy. Normalisation models were trained and validated using a leave-one-period-out approach. Regression-based correction yielded the greatest improvement, reducing RMSE by 16%. When applied to the full dataset, final correction factors reduced RMSE by 27%, out-of-range measurements by 43%, and proportional bias by 31%. Corrected sensors demonstrated highly consistent performance, particularly within the CO2 ranges most relevant for classroom ventilation assessment, with an RMSE = 7.4 parts per million (ppm) at ambient concentrations and 11.9 ppm at concentrations below 1500 ppm. Field-based co-location in the deployment environment across full CO2 cycles, combined with a network-derived global reference, produced effective correction factors. Performance declined marginally above 1500 ppm and during dynamic occupancy, while overall accuracy remained strong. The study presents a practical and accessible methodology for evaluating and normalising low-cost CO2 sensors without specialised laboratory equipment, supporting reliable ventilation assessments in schools.
Open AccessLow-Cost CO2 Sensors: On-Site Performance Evaluation and Co-Location Correction Procedure for Reliable Ventilation Assessments in Schools
Adequate ventilation is essential for maintaining indoor environmental quality in schools, where ventilation standards are often based on an indoor concentration of human-generated carbon dioxide (CO2) above ambient levels. Low-cost non-dispersive infrared (NDIR) CO2 sensors offer a practical solution for ventilation monitoring, yet variability between sensors can compromise accuracy, particularly when applications depend on the determination of precise concentration differences. This study evaluates the performance of twenty-three low-cost CO2 sensors, developing normalisation functions to improve comparability across sensors, introducing an accessible methodology for on-site sensor calibration without the need for laboratory-grade reference equipment. The sensors were co-located for three independent test periods in 2025 representing typical school internal conditions in Ireland. Pre-normalisation analysis showed strong linearity (coefficient of determination (R2) = 0.999) but notable variability, with a mean root mean square error (RMSE) of 18.3 ppm and 0.45% of measurements outside manufacturers stated accuracy. Normalisation models were trained and validated using a leave-one-period-out approach. Regression-based correction yielded the greatest improvement, reducing RMSE by 16%. When applied to the full dataset, final correction factors reduced RMSE by 27%, out-of-range measurements by 43%, and proportional bias by 31%. Corrected sensors demonstrated highly consistent performance, particularly within the CO2 ranges most relevant for classroom ventilation assessment, with an RMSE = 7.4 parts per million (ppm) at ambient concentrations and 11.9 ppm at concentrations below 1500 ppm. Field-based co-location in the deployment environment across full CO2 cycles, combined with a network-derived global reference, produced effective correction factors. Performance declined marginally above 1500 ppm and during dynamic occupancy, while overall accuracy remained strong. The study presents a practical and accessible methodology for evaluating and normalising low-cost CO2 sensors without specialised laboratory equipment, supporting reliable ventilation assessments in schools.
- Open Access
- 5 November 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (21) , 9873
The Nexus Between Indoor and Outdoor Environmental Conditions and Teacher Perceptions in Naturally Ventilated Primary School Classrooms, in Ireland
Indoor air quality (IAQ) and thermal comfort influence the health and cognitive performance of school occupants. This study investigated carbon dioxide (CO2), nitrogen dioxide (NO2), thermal comfort, and ventilation rates (VRs) in eight naturally ventilated (NV) primary school classrooms in Ireland during October 2024, combining environmental monitoring with teacher surveys. Mean CO2 concentrations ranged from 796 ppm to 2469 ppm, exceeding national guidelines in seven of the eight classrooms. NO2 levels ranged from 3.4 µg/m3 to 7.2 µg/m3, with indoor/outdoor ratios increasing with VRs and influenced by window orientation and road proximity. Indoor temperatures remained within recommended limits, while relative humidity ranged from 53% to 78% mirroring CO2 trends and exceeding guideline levels in classrooms with lower VRs and temperatures. Occupied VRs ranged from 1.2 L/p/s to 4.1 L/p/s with window opening behaviours, reliant on teachers’ perceptions of thermal comfort, accounting for 84% to 96% of VRs. Ventilation in NV classrooms is often insufficient, yet increasing VRs can compromise thermal comfort and increase ingress of outdoor pollutants and noise. The findings highlight the ineffectiveness of current school ventilation standards, which rely heavily on user operation. Integrating occupant-led strategies, including scheduled purging, awareness campaigns, and pre-emptive air quality alerting, into policy offers practical, immediate pathways to improving IAQ, fostering healthy, sustainable learning environments.
- 5 November 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (21) , 9873
Open AccessThe Nexus Between Indoor and Outdoor Environmental Conditions and Teacher Perceptions in Naturally Ventilated Primary School Classrooms, in Ireland
Indoor air quality (IAQ) and thermal comfort influence the health and cognitive performance of school occupants. This study investigated carbon dioxide (CO2), nitrogen dioxide (NO2), thermal comfort, and ventilation rates (VRs) in eight naturally ventilated (NV) primary school classrooms in Ireland during October 2024, combining environmental monitoring with teacher surveys. Mean CO2 concentrations ranged from 796 ppm to 2469 ppm, exceeding national guidelines in seven of the eight classrooms. NO2 levels ranged from 3.4 µg/m3 to 7.2 µg/m3, with indoor/outdoor ratios increasing with VRs and influenced by window orientation and road proximity. Indoor temperatures remained within recommended limits, while relative humidity ranged from 53% to 78% mirroring CO2 trends and exceeding guideline levels in classrooms with lower VRs and temperatures. Occupied VRs ranged from 1.2 L/p/s to 4.1 L/p/s with window opening behaviours, reliant on teachers’ perceptions of thermal comfort, accounting for 84% to 96% of VRs. Ventilation in NV classrooms is often insufficient, yet increasing VRs can compromise thermal comfort and increase ingress of outdoor pollutants and noise. The findings highlight the ineffectiveness of current school ventilation standards, which rely heavily on user operation. Integrating occupant-led strategies, including scheduled purging, awareness campaigns, and pre-emptive air quality alerting, into policy offers practical, immediate pathways to improving IAQ, fostering healthy, sustainable learning environments.
- 1 October 2025
- Published by Springer Nature
- p. 517-528
Evaluating Agricultural Crop Waste for Fabricating Biomaterial Insulation Board Prototypes
- 1 October 2025
- Published by Springer Nature
- p. 517-528
Evaluating Agricultural Crop Waste for Fabricating Biomaterial Insulation Board Prototypes
- 1 October 2025
- Published by Springer Nature
- p. 447-459
A New Method for Assessing the Vulnerability of Eastern Caribbean Buildings to Natural Disasters Using Remote Sensing
- 1 October 2025
- Published by Springer Nature
- p. 447-459
A New Method for Assessing the Vulnerability of Eastern Caribbean Buildings to Natural Disasters Using Remote Sensing