Adib Khanafer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adib Khanafer has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Andrew Laing
Interventional Radiology, Christchurch Hospital, 2 Riccarton Avenue Christchurch 8011, New Zealand
3 shared publications- Manar Khashram
Department of Vascular Surgery, Waikato Hospital, Hamilton, New Zealand
3 shared publications Dana Mann
Interventional Radiology, Christchurch Hospital, Christchurch, New Zealand
2 shared publicationsAfif Mahmud
Department of Vascular, Endovascular and Transplant Surgery, Christchurch Hospital, Christchurch
1 shared publicationCarmen-Maria Ruiz
Vascular, Endovascular, & Renal Transplant Unit, Christchurch Hospital, Christchurch, New Zealand
1 shared publicationDirk Misselhorn
1 shared publication
Latest Publications
- 17 December 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 144 (4)
Review of the Development of Hemodynamic Modeling Techniques to Capture Flow Behavior in Arteries Affected by Aneurysm, Atherosclerosis, and Stenting
Cardiovascular diseases (CVDs) are the leading cause of death in the developed world. CVD can include atherosclerosis, aneurysm, dissection, or occlusion of the main arteries. Many CVDs are caused by unhealthy hemodynamics. Some CVDs can be treated with the implantation of stents and stent grafts. Investigations have been carried out to understand the effects of stents and stent grafts have on arteries and the hemodynamic changes post-treatment. Numerous studies on stent hemodynamics have been carried out using computational fluid dynamics (CFD) which has yielded significant insight into the effect of stent mesh design on near-wall blood flow and improving hemodynamics. Particle image velocimetry (PIV) has also been used to capture behavior of fluids that mimic physiological hemodynamics. However, PIV studies have largely been restricted to unstented models or intra-aneurysmal flow rather than peri or distal stent flow behaviors. PIV has been used both as a standalone measurement method and as a comparison to validate the CFD studies. This article reviews the successes and limitations of CFD and PIV-based modeling methods used to investigate the hemodynamic effects of stents. The review includes an overview of physiology and relevant mechanics of arteries as well as consideration of boundary conditions and the working fluids used to simulate blood for each modeling method along with the benefits and limitations introduced.
- 17 December 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 144 (4)
Review of the Development of Hemodynamic Modeling Techniques to Capture Flow Behavior in Arteries Affected by Aneurysm, Atherosclerosis, and Stenting
Cardiovascular diseases (CVDs) are the leading cause of death in the developed world. CVD can include atherosclerosis, aneurysm, dissection, or occlusion of the main arteries. Many CVDs are caused by unhealthy hemodynamics. Some CVDs can be treated with the implantation of stents and stent grafts. Investigations have been carried out to understand the effects of stents and stent grafts have on arteries and the hemodynamic changes post-treatment. Numerous studies on stent hemodynamics have been carried out using computational fluid dynamics (CFD) which has yielded significant insight into the effect of stent mesh design on near-wall blood flow and improving hemodynamics. Particle image velocimetry (PIV) has also been used to capture behavior of fluids that mimic physiological hemodynamics. However, PIV studies have largely been restricted to unstented models or intra-aneurysmal flow rather than peri or distal stent flow behaviors. PIV has been used both as a standalone measurement method and as a comparison to validate the CFD studies. This article reviews the successes and limitations of CFD and PIV-based modeling methods used to investigate the hemodynamic effects of stents. The review includes an overview of physiology and relevant mechanics of arteries as well as consideration of boundary conditions and the working fluids used to simulate blood for each modeling method along with the benefits and limitations introduced.
- 1 November 2016
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 27 (11) , 1712-1714
Endovascular Repair of a Traumatic Ascending Aortic Tear Injury
- 1 November 2016
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 27 (11) , 1712-1714
Endovascular Repair of a Traumatic Ascending Aortic Tear Injury
- 14 October 2016
- Vol. 129 (1443) , 53-60
Rapid access carotid endarterectomy: winning the RACE following a natural disaster.
Rapid access carotid endarterectomy (RACE) is the gold standard for stroke prevention in symptomatic patients with 50-99% internal carotid artery stenosis. Diagnosis and referral of eligible patients may be delayed by disruption to local health services. The aim of this study was to evaluate whether service provision was maintained at an appropriate standard (<2 weeks) following a natural disaster. Consecutive symptomatic patients who underwent carotid endarterectomy (CEA) at a tertiary hospital between January 2006 and December 2014 were identified. The timeline from initial presentation to carotid imaging, vascular review and surgery was mapped. The post-earthquake period was defined between 22nd of February 2011 until July 2012. Of the 404 patients that underwent CEA during the above period, 62 patients presented during the post-earthquake period and these patients comprised the primary study group. The median time between presentation and CEA was nine days. In all, 47 patients had CEA within two weeks from the index event. The number of CEA procedures doubled since 2009. Despite many challenges following a major natural disaster, delivery of RACE has been maintained at an acceptable standard. Some delays persist and these remain areas for improvement in future.
- 14 October 2016
- Vol. 129 (1443) , 53-60
Rapid access carotid endarterectomy: winning the RACE following a natural disaster.
Rapid access carotid endarterectomy (RACE) is the gold standard for stroke prevention in symptomatic patients with 50-99% internal carotid artery stenosis. Diagnosis and referral of eligible patients may be delayed by disruption to local health services. The aim of this study was to evaluate whether service provision was maintained at an appropriate standard (<2 weeks) following a natural disaster. Consecutive symptomatic patients who underwent carotid endarterectomy (CEA) at a tertiary hospital between January 2006 and December 2014 were identified. The timeline from initial presentation to carotid imaging, vascular review and surgery was mapped. The post-earthquake period was defined between 22nd of February 2011 until July 2012. Of the 404 patients that underwent CEA during the above period, 62 patients presented during the post-earthquake period and these patients comprised the primary study group. The median time between presentation and CEA was nine days. In all, 47 patients had CEA within two weeks from the index event. The number of CEA procedures doubled since 2009. Despite many challenges following a major natural disaster, delivery of RACE has been maintained at an acceptable standard. Some delays persist and these remain areas for improvement in future.
- Open Access
- 4 December 2015
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 23 (1) , 212-215
Use of the Off-the-Shelf t-Branch Device to Treat an Acute Type Ia Endoleak in a Symptomatic Juxtarenal Abdominal Aortic Aneurysm
Purpose: To report the use of the off-the-shelf Zenith t-Branch Thoracoabdominal Endovascular Graft for the treatment of a symptomatic acute type Ia endoleak subsequent to previous infrarenal bifurcated endovascular aneurysm repair. Case Report: A 72-year-old man presented 4 years after implantation of an Anaconda stent-graft with sac expansion and type II endoleak, which was treated over the next 18 months with repeated coil and glue embolization of the leak and sac. Six months after the last attempt, imaging disclosed a new type Ia endoleak. Sac enlargement became symptomatic, and emergent treatment was performed using the off-the-shelf Zenith b-Branch device. The 4 visceral arteries were bridged with Fluency stent-grafts. The Anaconda stent-graft precluded the use of a standard Zenith universal distal body bifurcated device below the t-Branch graft, so a reversed tapered 16×20×82-mm iliac limb was placed to bridge the t-Branch to the larger Anaconda limb; the smaller 12-mm contralateral Anaconda limb was occluded. The procedure was concluded with a femorofemoral bypass. At 10 months after the procedure, the patient is well; the sac diameter has decreased, and there is no endoleak on imaging. Conclusion: The multibranched Zenith t-branch device may be useful in treating proximal endoleaks in bifurcated stent-grafts.
- 4 December 2015
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 23 (1) , 212-215
Open AccessUse of the Off-the-Shelf t-Branch Device to Treat an Acute Type Ia Endoleak in a Symptomatic Juxtarenal Abdominal Aortic Aneurysm
Purpose: To report the use of the off-the-shelf Zenith t-Branch Thoracoabdominal Endovascular Graft for the treatment of a symptomatic acute type Ia endoleak subsequent to previous infrarenal bifurcated endovascular aneurysm repair. Case Report: A 72-year-old man presented 4 years after implantation of an Anaconda stent-graft with sac expansion and type II endoleak, which was treated over the next 18 months with repeated coil and glue embolization of the leak and sac. Six months after the last attempt, imaging disclosed a new type Ia endoleak. Sac enlargement became symptomatic, and emergent treatment was performed using the off-the-shelf Zenith b-Branch device. The 4 visceral arteries were bridged with Fluency stent-grafts. The Anaconda stent-graft precluded the use of a standard Zenith universal distal body bifurcated device below the t-Branch graft, so a reversed tapered 16×20×82-mm iliac limb was placed to bridge the t-Branch to the larger Anaconda limb; the smaller 12-mm contralateral Anaconda limb was occluded. The procedure was concluded with a femorofemoral bypass. At 10 months after the procedure, the patient is well; the sac diameter has decreased, and there is no endoleak on imaging. Conclusion: The multibranched Zenith t-branch device may be useful in treating proximal endoleaks in bifurcated stent-grafts.
- Open Access
- 1 January 2015
- Published by Elsevier in EJVES Short Reports
- Vol. 29, 1-2
Bilateral Common Iliac Artery Stenosis: A Novel Technique for Deployment of Kissing Iliac Artery Stents
- 1 January 2015
- Published by Elsevier in EJVES Short Reports
- Vol. 29, 1-2
Open AccessBilateral Common Iliac Artery Stenosis: A Novel Technique for Deployment of Kissing Iliac Artery Stents
- 25 January 2012
- Vol. 126 (1368) , 82-5
Focal common carotid artery intramural haematoma.
Focal common carotid artery intramural haematomas are rare. A 50-year-old man with a spontaneous onset of tenderness in the region of the right common carotid artery presented to our hospital (Christchurch, New Zealand). Ultrasound and CT imaging were consistent for an intramural haematoma. He was treated with antiplatelet therapy. A follow-up MRA showed resolution of the haematoma. Focal common carotid artery intramural haematomas are rare but not to be overlooked. This case presents a cause for intractable spontaneous neck pain in the region of the common carotid artery. Given the risk of rupture through the intima and potential risk for stroke the current recommended treatment is controversial.
- 25 January 2012
- Vol. 126 (1368) , 82-5
Focal common carotid artery intramural haematoma.
Focal common carotid artery intramural haematomas are rare. A 50-year-old man with a spontaneous onset of tenderness in the region of the right common carotid artery presented to our hospital (Christchurch, New Zealand). Ultrasound and CT imaging were consistent for an intramural haematoma. He was treated with antiplatelet therapy. A follow-up MRA showed resolution of the haematoma. Focal common carotid artery intramural haematomas are rare but not to be overlooked. This case presents a cause for intractable spontaneous neck pain in the region of the common carotid artery. Given the risk of rupture through the intima and potential risk for stroke the current recommended treatment is controversial.