Rok Dolenec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rok Dolenec has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Rok Pestotnik
Jozef Stefan Institute
4 shared publications - Samo Korpar
Experimental Particle Physics Department, Jožef Stefan Institute, Ljubljana, Slovenia
4 shared publications P. Križan
University of Ljubljana
3 shared publications- Peter Krizan
Jožef Stefan Institute, Ljubljana, Slovenia
3 shared publications - Dejan Žontar
Experimental Particle Physics Department, Jožef Stefan Institute, Ljubljana, Slovenia
2 shared publications - H. Kakuno
Tokyo Metropolitan University
2 shared publications
Latest Publications
- Open Access
- 27 September 2024
- Published by Springer Nature in The European Physical Journal C
- Vol. 84 (9) , 1-14
Characterization of neutron-irradiated SiPMs down to liquid nitrogen temperature
Photodetectors used in future high-energy physics experiments will need to keep sufficient performance during a few years of data-taking despite radiation load, which, for example, in the planned upgrade of the Ring Imaging Cherenkov detectors in Large Hadron Collider beauty (LHCb) experiment is estimated at about 10 $$^{13}$$ 1-MeV neutron equivalent per cm $$^{2}$$ (neq/cm $$^{2}$$ ). Silicon photomultipliers (SiPMs) are considered as candidates for photodetectors for this application. However, their sensitivity to neutron irradiation may seriously compromise their operation, with the increase in dark count rates being the primary limitation after the irradiation. In this work, 1 $$\times $$ 1 mm $$^{2}$$ 15 $$\mu $$ m pitch NUV-HD-RH silicon photomultipliers developed by the Fondazione Bruno Kessler were characterized before and after the irradiation. In total, 5 SiPMs were irradiated at the Jožef Stefan Institute TRIGA nuclear reactor with different fluences from 10 $$^{9}$$ neq/cm $$^{2}$$ up to 10 $$^{13}$$ neq/cm $$^{2}$$ . The SiPMs were also annealed at high temperatures and re-characterized after the annealing. For the SiPM characterization in all the cases, current–voltage (I-V curve) measurements, dark count rate measurements, and waveform analysis, including single photon time resolution, were carried out at different controlled temperature steps from room temperature down to the liquid nitrogen temperature. While cooling to − 20 $$^{\circ }$$ C was enough for the SiPM irradiated at 10 $$^{9}$$ neq/cm $$^{2}$$ to recover the ability to resolve single photons, by 10 $$^{13}$$ neq/cm $$^{2}$$ , cooling to liquid nitrogen temperature was necessary. With sufficient cooling, the measured single photon time resolution was around 90 ps FWHM for all irradiation levels.- 27 September 2024
- Published by Springer Nature in The European Physical Journal C
- Vol. 84 (9) , 1-14
Open AccessCharacterization of neutron-irradiated SiPMs down to liquid nitrogen temperature
Photodetectors used in future high-energy physics experiments will need to keep sufficient performance during a few years of data-taking despite radiation load, which, for example, in the planned upgrade of the Ring Imaging Cherenkov detectors in Large Hadron Collider beauty (LHCb) experiment is estimated at about 10 $$^{13}$$ 1-MeV neutron equivalent per cm $$^{2}$$ (neq/cm $$^{2}$$ ). Silicon photomultipliers (SiPMs) are considered as candidates for photodetectors for this application. However, their sensitivity to neutron irradiation may seriously compromise their operation, with the increase in dark count rates being the primary limitation after the irradiation. In this work, 1 $$\times $$ 1 mm $$^{2}$$ 15 $$\mu $$ m pitch NUV-HD-RH silicon photomultipliers developed by the Fondazione Bruno Kessler were characterized before and after the irradiation. In total, 5 SiPMs were irradiated at the Jožef Stefan Institute TRIGA nuclear reactor with different fluences from 10 $$^{9}$$ neq/cm $$^{2}$$ up to 10 $$^{13}$$ neq/cm $$^{2}$$ . The SiPMs were also annealed at high temperatures and re-characterized after the annealing. For the SiPM characterization in all the cases, current–voltage (I-V curve) measurements, dark count rate measurements, and waveform analysis, including single photon time resolution, were carried out at different controlled temperature steps from room temperature down to the liquid nitrogen temperature. While cooling to − 20 $$^{\circ }$$ C was enough for the SiPM irradiated at 10 $$^{9}$$ neq/cm $$^{2}$$ to recover the ability to resolve single photons, by 10 $$^{13}$$ neq/cm $$^{2}$$ , cooling to liquid nitrogen temperature was necessary. With sufficient cooling, the measured single photon time resolution was around 90 ps FWHM for all irradiation levels. - Open Access
- 6 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1976
Design Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study
In time-of-flight positron emission tomography (TOF-PET), a coincidence time resolution (CTR) below 100 ps reduces the angular coverage requirements and, thus, the geometric constraints of the scanner design. Among other possibilities, this opens the possibility of using flat-panel PET detectors. Such a design would be more cost-accessible and compact and allow for a higher degree of modularity than a conventional ring scanner. However, achieving adequate CTR is a considerable challenge and requires improvements at every level of detection. Based on recent results in the ongoing development of optimised TOF-PET photodetectors and electronics, we expect that within a few years, a CTR of about 75 ps will be be achievable at the system level. In this work, flat-panel scanners with four panels and various design parameters were simulated, assessed and compared to a reference scanner based on the Siemens Biograph Vision using NEMA NU 2-2018 metrics. Point sources were also simulated, and a method for evaluating spatial resolution that is more appropriate for flat-panel geometry is presented. We also studied the effects of crystal readout strategies, comparing single-crystal and module readout levels. The results demonstrate that with a CTR below 100 ps, a flat-panel scanner can achieve image quality comparable to that of a reference clinical scanner, with considerable savings in scintillator material.
- 6 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (17) , 1976
Open AccessDesign Optimisation of a Flat-Panel, Limited-Angle TOF-PET Scanner: A Simulation Study
In time-of-flight positron emission tomography (TOF-PET), a coincidence time resolution (CTR) below 100 ps reduces the angular coverage requirements and, thus, the geometric constraints of the scanner design. Among other possibilities, this opens the possibility of using flat-panel PET detectors. Such a design would be more cost-accessible and compact and allow for a higher degree of modularity than a conventional ring scanner. However, achieving adequate CTR is a considerable challenge and requires improvements at every level of detection. Based on recent results in the ongoing development of optimised TOF-PET photodetectors and electronics, we expect that within a few years, a CTR of about 75 ps will be be achievable at the system level. In this work, flat-panel scanners with four panels and various design parameters were simulated, assessed and compared to a reference scanner based on the Siemens Biograph Vision using NEMA NU 2-2018 metrics. Point sources were also simulated, and a method for evaluating spatial resolution that is more appropriate for flat-panel geometry is presented. We also studied the effects of crystal readout strategies, comparing single-crystal and module readout levels. The results demonstrate that with a CTR below 100 ps, a flat-panel scanner can achieve image quality comparable to that of a reference clinical scanner, with considerable savings in scintillator material.
- 8 August 2018
- Published by Springer Nature in Springer Proceedings in Physics
- p. 46-49
Development of Slow Control System for the Belle II ARICH Counter
- 8 August 2018
- Published by Springer Nature in Springer Proceedings in Physics
- p. 46-49
Development of Slow Control System for the Belle II ARICH Counter
- 8 August 2018
- Published by Springer Nature in Springer Proceedings in Physics
- p. 315-318
Behavior of 144ch HAPDs for the Belle II Aerogel RICH in the Magnetic Field
- 8 August 2018
- Published by Springer Nature in Springer Proceedings in Physics
- p. 315-318
Behavior of 144ch HAPDs for the Belle II Aerogel RICH in the Magnetic Field
- 30 September 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 804, 127-131
Cherenkov TOF PET with silicon photomultipliers
- 30 September 2015
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 804, 127-131
Cherenkov TOF PET with silicon photomultipliers
- 17 June 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 654 (1) , 532-538
Study of TOF PET using Cherenkov light
- 17 June 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 654 (1) , 532-538
Study of TOF PET using Cherenkov light