  • Relevance of the radon space shadow zone in coplanar and non-coplanar volumetric modulated arc therapy: studies on head and neck and geometrical targets

    by Gary Razinskas, Victor Lewitzki, Florian Exner, André Toussaint, Klaus Bratengeier

    Objective: To investigate key geometrical sampling properties and potential advantages of non-coplanar volumetric modulated arc therapy (VMAT) compared with coplanar VMAT. The study is motivated by cone-beam computed tomography (CBCT) reconstruction theory, particularly concepts related to sampling completeness. The analysis focuses on head and neck cancers (HNC) and geometric phantoms. Approach: VMAT was simulated using densely spaced, fluence-optimized static beams. Non-coplanar partial arcs with angular ranges of 32°, 64°, or 180° centred at predefined gantry angles were added orthogonally to the standard coplanar circular beam arrangement, which served as the reference configuration. Plan quality was evaluated using the composite objective value (COV), the minimum dose to the planning target volume (PTV), and the dose in cranio-caudal planes immediately adjacent to the PTV. The study included twenty patients with oro-, hypo-, or nasopharyngeal carcinomas with extended cranio–caudal target volumes (>15 cm) and complex anatomical organ at risk (OAR) proximity. In addition, idealised phantom cases (spherical or cylindrical PTVs with surrounding OAR structures) were analysed similarly to investigate controlled geometric configurations. Main results: Incorporation of non-coplanar arcs consistently improved plan quality. The most pronounced effect was observed for additional 180° arcs; however, even arcs with reduced angular range centered around the 0° gantry angle significantly increased PTV minimum dose while reducing dose to adjacent cranio-caudal tissues. These improvements are explained by the circle-and-arc beam configuration, which fulfils the Tuy condition known from CBCT theory by filling the Radon space shadow zone. Significance: Non-coplanar arcs with reduced angular ranges can enhance target coverage and organ sparing in elongated HNC targets. By transferring mathematical principles from CBCT reconstruction to radiotherapy planning, this work demonstrates how fulfilling the Tuy condition can improve VMAT dose distributions and may inform future developments in dynamic trajectory radiotherapy.

  • Open Access

    Dosimetric evaluation of a spinal cord dose‐limiting 3D‐CRT technique for radiotherapy of spinal metastases

    by Christian Cornelius Arnold, André Toussaint, Frederick Mantel, Michael Flentje, Klaus Bratengeier

    Background: To evaluate the possible advantages of a simple spinal cord (SC) dose‐limiting three‐dimensional conformal radiotherapy (3D‐CRT) technique in comparison to conventional two‐dimensional (2D) techniques and other 3D‐CRT techniques for spinal bone irradiation.Methods: For 41 spinal target volumes, seven different techniques were evaluated, using a standard schedule of 30 Gy in 10 fractions. The SC dose‐limiting 3D‐CRT technique 1F2S‐18MV using a single posterior field (F) supplemented by two anterior segment fields (S) and 18‐MV photon beams was compared to two conventional 2D techniques (a single posterior field, PA, and two opposed anterior‐posterior fields, APPA), three other 3D‐CRT techniques (a single posterior field supplemented by four segment fields, 1F4S; two wedged fields, WD, and the SC dose‐limiting variant using 6 MV, 1F2S‐6MV) along with the original clinically applied plans.Results: 1F2S‐18MV demonstrated notably better results for all target volume parameters compared to the conventional 2D techniques (p < 0.001). Limitation of the SC dose was significantly superior with 1F2S‐18MV in comparison to PA and APPA (SC Dmean: 28.9 ± 0.4 vs. 30.1 ± 0.6 Gy and 30.1 ± 0.4 Gy; SC Dmax: 30.9 ± 0.7 vs. 32.5 ± 1.0 Gy and 31.8 ± 0.7 Gy; SC D1cm3: 30.1 ± 0.6 vs. 31.7 ± 0.9 Gy and 31.1 ± 0.6 Gy; p < 0.001). Likewise, lower mean SC doses with 1F2S‐18MV were observed in comparison to the more treatment time‐consuming 3D‐CRT techniques (1F4S, WD) and the original plans without relevant compromises on the dose homogeneity in the target volume and the dose exposure to the other OARs.Conclusion: In treatment planning of spinal metastases, simple variants of 3D‐CRT‐techniques like 1F2S‐18MV can offer a significant dose limitation to the SC while providing a sufficient dose coverage of the target volume. Especially in patients with favorable life expectancy and potential need for re‐irradiation, such SC dose‐limiting 3D‐CRT techniques may be a reasonable approach.

  • Open Access

    Treatment plan comparison for irradiation of multiple brain metastases with hippocampal avoidance whole brain radiotherapy and simultaneous integrated boost using the Varian Halcyon and the Elekta Synergy platforms

    by Johannes Kraft, Stefan Weick, Kathrin Breuer, Paul Lutyj, Klaus Bratengeier, Florian Exner, Anne Richter, Jörg Tamihardja, Dominik Lisowski, Bülent Polat, et al.


  • Open Access

    The role of beam density and arrangement in non-coplanar IMRT exemplified by the irradiation of brain tumors – Parallels to computed tomographic imaging

    by Gary Razinskas, Tobias Stumm, Rebekka Kosmala, Bülent Polat, Mario Löhr, Michael Flentje, Klaus Bratengeier


  • Open Access

    Comparison of sliding window and field-in-field techniques for tangential whole breast irradiation using the Halcyon and Synergy Agility systems

    by Anne Richter, Sonja Wegener, Kathrin Breuer, Gary Razinskas, Stefan Weick, Florian Exner, Klaus Bratengeier, Michael Flentje, Otto Sauer, Bülent Polat

    Background: To implement a tangential treatment technique for whole breast irradiation using the Varian Halcyon and to compare it with Elekta Synergy Agility plans. Methods: For 20 patients two comparable treatment plans with respect to dose coverage and normal tissue sparing were generated. Tangential field-in-field treatment plans (Pinnacle/Synergy) were replanned using the sliding window technique (Eclipse/Halcyon). Plan specific QA was performed using the portal Dosimetry and the ArcCHECK phantom. Imaging and treatment dose were evaluated for treatment delivery on both systems using a modified CIRS Phantom. Results: The mean number of monitor units for a fraction dose of 2.67 Gy was 515 MUs and 260 MUs for Halcyon and Synergy Agility plans, respectively. The homogeneity index and dose coverage were similar for both treatment units. The plan specific QA showed good agreement between measured and calculated plans. All Halcyon plans passed portal dosimetry QA (3%/2 mm) with 100% points passing and ArcCheck QA (3%/2 mm) with 99.5%. Measurement of the cumulated treatment and imaging dose with the CIRS phantom resulted in lower dose to the contralateral breast for the Halcyon plans. Conclusions: For the Varian Halcyon a plan quality similar to the Elekta Synergy device was achieved. For the Halcyon plans the dose contribution from the treatment fields to the contralateral breast was even lower due to less interleaf transmission of the Halcyon MLC and a lower contribution of scattered dose from the collimator system.


  • Open Access

    Impact of beam configuration on VMAT plan quality for Pinnacle3Auto-Planning for head and neck cases

    by Anne Richter, Florian Exner, Klaus Bratengeier, Bülent Polat, Michael Flentje, Stefan Weick

    The purpose of this study was to compare automatically generated VMAT plans to find the superior beam configurations for Pinnacle3 Auto-Planning and share “best practices”. VMAT plans for 20 patients with head and neck cancer were generated using Pinnacle3 Auto-Planning Module (Pinnacle3 Version 9.10) with different beam setup parameters. VMAT plans for single (V1) or double arc (V2) and partial or full gantry rotation were optimized. Beam configurations with different collimator positions were defined. Target coverage and sparing of organs at risk were evaluated based on scoring of an evaluation parameter set. Furthermore, dosimetric evaluation was performed based on the composite objective value (COV) and a new cross comparison method was applied using the COVs. The evaluation showed a superior plan quality for double arcs compared to one single arc or two single arcs for all cases. Plan quality was superior if a full gantry rotation was allowed during optimization for unilateral target volumes. A double arc technique with collimator setting of 15° was superior to a double arc with collimator 60° and a two single arcs with collimator setting of 15° and 345°. The evaluation showed that double and full arcs are superior to single and partial arcs in terms of organs at risk sparing even for unilateral target volumes. The collimator position was found as an additional setup parameter, which can further improve the target coverage and sparing of organs at risk.


  • Open Access

    Steeper dose gradients resulting from reduced source to target distance—a planning system independent study

    by Klaus Bratengeier, Kostyantyn Holubyev, Sonja Wegener

    Purpose To quantify the contribution of penumbra in the improvement of healthy tissue sparing at reduced source‐to‐axis distance (SAD) for simple spherical target and different prescription isodoses (PI). Method A TPS‐independent method was used to estimate three‐dimensional (3D) dose distribution for stereotactic treatment of spherical targets of 0.5 cm radius based on single beam two‐dimensional (2D) film dosimetry measurements. 1 cm target constitutes the worst case for the conformation with standard Multi‐Leaf Collimator (MLC) with 0.5 cm leaf width. The measured 2D transverse dose cross‐sections and the profiles in leaf and jaw directions were used to calculate radial dose distribution from isotropic beam arrangement, for both quadratic and circular beam openings, respectively. The results were compared for standard (100 cm) and reduced SAD 70 and 55 cm for different PI. Results For practical reduction of SAD using quadratic openings, the improvement of healthy tissue sparing (HTS) at distances up to 3 times the PTV radius was at least 6%–12%; gradient indices (GI) were reduced by 3–39% for PI between 40% and 90%. Except for PI of 80% and 90%, quadratic apertures at SAD 70 cm improved the HTS by up to 20% compared to circular openings at 100 cm or were at least equivalent; GI were 3%–33% lower for reduced SAD in the PI range 40%–70%. For PI = 80% and 90% the results depend on the circular collimator model. Conclusion Stereotactic treatments of spherical targets delivered at reduced SAD of 70 or 55 cm using MLC spare healthy tissue around the target at least as good as treatments at SAD 100 cm using circular collimators. The steeper beam penumbra at reduced SAD seems to be as important as perfect target conformity. The authors argue therefore that the beam penumbra width should be addressed in the stereotactic studies.


  • Open Access

    Distance-dependent penumbra and MLC-width: new insights in determinants of healthy tissue sparing in stereotactic irradiation

    by Klaus Bratengeier, Sonja Wegener, Barbara Herzog

    For stereotactic irradiation, both, penumbra and MLC leaf width make an impact on the sparing of healthy tissue around the target. Mostly, MLC design is regarded as the one influenceable parameter. However, also penumbra can be varied by choosing different distances between the source of radiation and the patient. The authors investigate the distance- dependent penumbra effects of idealized collimators as well as for real 5 mm MLCs. Test objects are small spherical targets of varying diameters to be irradiated under differing prescription conditions. A method to calculate exact stereotactic radial dose distributions from beam profiles or 2D dose distributions of single beams is developed for circular and MLC shaped targets. Also, a planning study is performed using a Pinnacle3™ planning system. Also, in a theoretical analysis perfect top hat profile beams and beams with varying penumbra are compared for better understanding of penumbra effects with respect to radial dose distributions. It is shown, that the penumbra changes for small targets are more relevant than the beam shaping by 5 mm MLCs. Quasi-isotropic irradiated MLC shaped (quadratic) beams at virtual SAD 700 mm produce steeper radial dose decrease than ideal circular beam shapes with a penumbra typical for SAD 1000 mm. A reduced source-to-patient distance allows better sparing of healthy tissue because of two reasons: The smaller effective leaf width but even more due to steeper penumbra. First, the authors suggest for future recommendations on stereotactic irradiations to specify not only MLC widths but also penumbra characteristics. Second, a so-called “virtual isocentre” could be useful to take advantage of the penumbra effect: Dependent on gantry angle and isocentric couch angle, the couch should be steered automatically in a way that the central axes of all beams always intersect in the same point at the same distance from the source.

  • Open Access

    Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study

    by Klaus Bratengeier, Barbara Herzog, Sonja Wegener, Kostyantyn Holubyev

    Investigation of a reduced source to target distance to improve organ at risk sparing during stereotactic irradiation (STX). The authors present a planning study with perfectly target-volume adapted collimator compared with multi-leaf collimator (MLC) at reduced source to virtual isocentre distance (SVID) in contrast to normal source to isocentre distance (SID) for stereotactic applications. The role of MLC leaf width and 20–80% penumbra was examined concerning the healthy tissue sparing. Several prescription schemes and target diameters are considered. Paddick’s gradient index (GI) as well as comparison of the mean doses to spherical shells at several distances to the target is evaluated. Both emphasize the same results: the healthy tissue sparing in the high dose area around the planning target volume (PTV) is improved at reduced SVID ≤ 70 cm. The effect can be attributed more to steeper penumbra than to finer leaf resolution. Comparing circular collimators at different SVID just as MLC-shaped collimators, always the GI was reduced. Even MLC-shaped collimator at SVID 70 cm had better healthy tissue sparing than an optimal shaped circular collimator at SID 100 cm. Regarding penumbra changes due to varying SVID, the results of the planning study are underlined by film dosimetry measurements with Agility™ MLC. Penumbra requires more attention in comparing studies, especially studies using different planning systems. Reduced SVID probably allows usage of conventional MLC for STX-like irradiations.


  • Open Access

    Anisotropy of dose contributions-An instrument to upgrade real time IMRT and VMAT adaptation?

    by Klaus Bratengeier, Kostyantyn Holubyev

    Purpose: To suggest a definition of dose deposition anisotropy for the purpose of ad hoc adaptation of intensity modulated arc therapy (IMRT) and volumetric arc therapy (VMAT), particularly in the vicinity of important organs at risk (OAR), also for large deformations. Methods: Beam’s-eye-view (BEV) based fluence warping is a standard adaptation method with disadvantages for strongly varying OAR shapes. 2-Step-adaptation overcomes these difficulties by a deeper analysis of the 3D properties of adaptation processes, but requires separate arcs for every OAR to spare, which makes it impractical for cases with multiple OARs. The authors aim to extend the 2-Step method to arbitrary intensity modulated plan by analyzing the anisotropy of dose contributions. Anisotropy was defined as a second term of Fourier transformation of gantry angle dependent dose contributions. For a cylindrical planning target volume (PTV) surrounding an OAR of varying diameter, the anisotropy and the dose-normalized anisotropy were analyzed for several scenarios of optimized fluence distributions. 2-Step adaptation to decreasing and increasing OAR diameter was performed, and compared to a usual fluence based adaptation method. For two clinical cases, prostate and neck, the VMAT was generated and the behavior of anisotropy was qualitatively explored for deformed organs at risk. Results: Dose contribution anisotropy in the PTV peaks around nearby OARs. The thickness of the “anisotropy wall” around OAR increases for increasing OAR radius, as also does the width of 2-Step dose saturating fluence peak adjacent to the OAR [K. Bratengeier et al., “A comparison between 2-Step IMRT and conventional IMRT planning,” Radiother. Oncol. 84, 298–306 (2007)]. Different optimized beam fluence profiles resulted in comparable radial dependence of normalized anisotropy. As predicted, even for patient cases, anisotropy was inflated even more than increasing diameters of OAR. Conclusions: For cylindrically symmetric cases, the dose distribution anisotropy defined in the present work implicitly contains adaptation-relevant information about 3D relationships between PTV and OAR and degree of OAR sparing. For more complex realistic cases, it shows the predicted behavior qualitatively. The authors claim to have found a first component for advancing a 2-Step adaptation to a universal adaptation algorithm based on the BEV projection of the dose anisotropy. Further planning studies to explore the potential of anisotropy for adaptation algorithms using phantoms and clinical cases of differing complexity will follow.