Boris Goj
Research Subjects
Boris Goj has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
L Dressler
1 shared publication- Lars Dittrich
Micromechanical Systems Group
1 shared publication Lothar Dressler
Technische Universität Ilmenau
1 shared publication- Lothar Dressler
Micromechanical Systems Group
1 shared publication M Hoffmann
1 shared publicationMartin Hoffmann
Technische Universität Ilmenau
1 shared publication
Latest Publications
- 2 March 2017
- Published by ASME International in Journal of Micro and Nano-Manufacturing
- Vol. 5 (2) , 021002
Material Dependence of the Contact Behavior of Oscillating Microprobes—Modeling and Experimental Evidence
Oscillating microprobes avoid high stress and the sticking effect during contact between microprobe and measured surface. The full performance and application scope of oscillating microprobes can be explored and utilized once the reliable prediction of the microprobe contact behavior is understood. Here, an improved contact model considering adhesion forces, surface roughness, and viscoelastic damping for oscillating microprobes is presented and it is validated by exemplary measurements utilizing a uniaxially oscillating electrostatic microprobe. These results show that the nondestructive identification of material classes seems to be feasible by evaluating the phase shift between the sinusoidal signals of sensor and actuator, respectively.
- 2 March 2017
- Published by ASME International in Journal of Micro and Nano-Manufacturing
- Vol. 5 (2) , 021002
Material Dependence of the Contact Behavior of Oscillating Microprobes—Modeling and Experimental Evidence
Oscillating microprobes avoid high stress and the sticking effect during contact between microprobe and measured surface. The full performance and application scope of oscillating microprobes can be explored and utilized once the reliable prediction of the microprobe contact behavior is understood. Here, an improved contact model considering adhesion forces, surface roughness, and viscoelastic damping for oscillating microprobes is presented and it is validated by exemplary measurements utilizing a uniaxially oscillating electrostatic microprobe. These results show that the nondestructive identification of material classes seems to be feasible by evaluating the phase shift between the sinusoidal signals of sensor and actuator, respectively.
- 30 October 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (12) , 125011
Design and characterization of a resonant triaxial microprobe
A new trend for tactile microprobes leads to oscillating microprobes in order to overcome the drawbacks resulting from high Hertzian stress and disturbing surface forces. Thin water films on the measurement surface result in the so-called sticking effect which causes measurement faults such as snap-back and false triggering. This leads to measurement errors and low measurement speeds. We present an innovative oscillating triaxial microprobe which safely avoids sticking in all Cartesian measurement directions. The system design as well as the characterization of the microprobe are presented in this work. The low number of coupling elements, the batch-capable design and the low contact forces are the key features of the microprobe.
- 30 October 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (12) , 125011
Design and characterization of a resonant triaxial microprobe
A new trend for tactile microprobes leads to oscillating microprobes in order to overcome the drawbacks resulting from high Hertzian stress and disturbing surface forces. Thin water films on the measurement surface result in the so-called sticking effect which causes measurement faults such as snap-back and false triggering. This leads to measurement errors and low measurement speeds. We present an innovative oscillating triaxial microprobe which safely avoids sticking in all Cartesian measurement directions. The system design as well as the characterization of the microprobe are presented in this work. The low number of coupling elements, the batch-capable design and the low contact forces are the key features of the microprobe.
- 6 August 2013
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 23 (9) , 095012
Resonant probing system comprising a high accurate uniaxial nanoprobe and a new evaluation unit
The increasing demand to tactilely measure micro-electro-mechanical systems featuring high aspect ratios leads to probing systems with low stiffness and small touching elements (e.g. ruby balls). Thus, more challenges arise because of an increasing influence of the so-called micro world effects. Sticking is one crucial effect which generates measurement faults like snap back and false triggering. This paper presents a highly accurate electrostatic probing system which operates at resonant motion to minimize the influence of capillary forces. The unique feature of the uniaxial nanoprobe is the fully integrated design in a silicon-on-insulator substrate which minimizes the number of coupling connections and improves the measurement accuracy.
- 6 August 2013
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 23 (9) , 095012
Resonant probing system comprising a high accurate uniaxial nanoprobe and a new evaluation unit
The increasing demand to tactilely measure micro-electro-mechanical systems featuring high aspect ratios leads to probing systems with low stiffness and small touching elements (e.g. ruby balls). Thus, more challenges arise because of an increasing influence of the so-called micro world effects. Sticking is one crucial effect which generates measurement faults like snap back and false triggering. This paper presents a highly accurate electrostatic probing system which operates at resonant motion to minimize the influence of capillary forces. The unique feature of the uniaxial nanoprobe is the fully integrated design in a silicon-on-insulator substrate which minimizes the number of coupling connections and improves the measurement accuracy.