QHQianqian Han

Qianqian Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qianqian Han has a total of 104 co-authors. Here are the top co-authors by number of shared publications:

  • Han Wang

    Institute for Medical Devices Control, National Institutes for Food and Drug Control , Beijing 102629

    5 shared publications
  • Chunren Wang

    National Institute for Food and Drug Control

    4 shared publications
  • Zhu Meng

    Affiliation Department of Medical Devices, National Institutes for Food and Drug Control, Beijing, China

    4 shared publications
  • Linnan Ke

    National Institutes for Food and Drug Control Institute for Medical Devices Control Beijing, 102629

    3 shared publications
  • Rui Wang

    National Institutes for Food and Drug Control Institute for Medical Devices Control Beijing, 102629

    3 shared publications
  • Yu Liu

    Affiliations Department of Medical Devices, National Institutes for Food and Drug Control, Beijing, China, YanTai University, Shandong Province, China

    3 shared publications

Latest Publications

  • Open Access

    Dual regulatory effects of medical bovine collagen sponge on macrophages in vitro

    by Rui Wang, Yu Liu, Jingjing Chen, Zhu Meng, Weiye Ren, Wei Huang, Zhaoxu Wang, Qianqian Han

    Medical bovine collagen sponges (MBCS) are extensively utilized in clinical settings for hemostasis and tissue augmentation owing to their superior biocompatibility, biodegradability and hemostatic properties. Nevertheless, their immunomodulatory influence on macrophage function remains largely unexplored. In this study, we systematically evaluated the effects of MBCS on RAW264.7 macrophages through comprehensive in vitro assays, including proliferation analysis, phagocytosis assessment, cytokine expression and angiogenesis evaluation. Our results demonstrate that MBCS significantly enhances macrophage proliferation and phagocytic capacity while potently stimulating VEGF secretion. Furthermore, MBCS-conditioned macrophage supernatants markedly promote endothelial tubule formation in vitro. Notably, MBCS moderately promotes inflammatory responses in resting macrophages, whereas pretreatment with MBCS effectively inhibits lipopolysaccharide (LPS)-induced pro-inflammatory reactions, as reflected by reduced production of TNF‑α, nitric oxide and CD86. These findings reveal the effects of MBCS on macrophages at the cellular level, providing experimental evidence and mechanistic support for its tissue-repairing functions.

  • Open Access

    A novel integrated in vitro method for evaluating the moisturizing performance of injectable sodium hyaluronate

    by Jianfeng Shi, Wenna Xu, Hongfu Liu, Fengjuan Shan, Rui Wang, Linnan Ke, Qianqian Han, Yong Lu

    Injectable sodium hyaluronate (NaHA) is extensively utilized in aesthetic medicine as a dermal hydrating agent. However, there are few standardized, human-relevant preclinical methods that can reliably evaluate the moisturizing performance of those products. Existing animal and simplified cell-based models show restricted physiological relevance and insufficient sensitivity. To address this gap, we established a depot-mimicking reconstructed human full-thickness skin (RhFS) platform incorporating an inclusion-based intradermal delivery strategy. Instead of conventional mixing, this strategy mimics the clinical “depot effect” of intradermal injection, allowing for the simultaneous assessment of cellular responses and tissue-level hydration dynamics. It forms a localized NaHA depot within the dermal compartment of RhFS and preserves spatial hydration gradients, which are lost when NaHA is mixed homogenously. The platform integrates physicochemical characterization of polymer-bound water states with cellular and tissue-level functional readouts. By quantifying key biomarkers, including CD44, aquaporin-3 (AQP3), and natural moisturizing factors (NMFs), our results demonstrate that the inclusion-based delivery strategy significantly outperforms conventional mixing approaches in activating epidermal hydration pathways. Crucially, this platform effectively distinguished the moisturizing efficacy of multiple commercial NaHA formulas, thereby revealing a structure-activity relationship between water-binding states and biological outcomes. Overall, this study presents a reproducible, mechanism-informed, and human-relevant framework for preclinical performance evaluation of NaHA-based injectable biomaterials and provides a sensitive alternative to conventional animal-based approaches.


  • Open Access

    Preparation and evaluation of a small-diameter vascular graft with dual anticoagulant and anticalcification functions

    by Xiaomeng Su, Han Wang, Hongbo Chen, Linnan Ke, Qianqian Han

    Cardiovascular diseases have become one of the major threats to human health. There is an urgent clinical need for small-diameter vascular grafts to achieve long-term implantation in the body. In previous studies, some progress has been made, but the prognosis is still poor. Heparin (HEP) is an anticoagulant that is widely applied in the clinical field and commonly used for anticoagulation modification of biomaterials. However, there is an important problem: HEP has almost no direct inhibitory effect on platelet adhesion, which may become one of the potential dangers after graft implantation. In recent years, it has been found that calcification is also a key factor affecting the long-term patency of small-diameter vascular grafts, which is often ignored. Therefore, in this study, based on HEP, procyanidin (PC) was introduced to modify the thermoplastic polyurethane (TPU) grafts fabricated by electrospinning to enhance the anticoagulation and anticalcification properties simultaneously. To verify the effects of drug modification on the material, the physical and chemical characterization, biocompatibility experiments and effectiveness tests of this vascular graft were conducted. The results indicated that the HEP-PC grafts could not only inhibit the excessive proliferation of human umbilical artery smooth muscle cells to some extent but also have excellent hemocompatibility. Particularly, in vivo experiments showed that this graft also achieved dual anticoagulation and delayed the calcification after implantation. These results suggested that HEP-PC-modified TPU might be a promising candidate for inhibiting intimal hyperplasia and anticalcification of small-diameter grafts.

  • [Research progress on calcification mechanism and anti-calcification strategies of vascular grafts].

    by Xiaomeng Su, Fanshan Qiu, Han Wang, Qianqian Han

    Artificial blood vessels are commonly applied in the treatment and reconstruction surgeries of cardiovascular diseases, which have a considerable clinical demand. Using a 6 mm diameter as a threshold, they are categorized into large- and small-diameter types. Calcification is one of the factors affecting whether artificial blood vessels can successfully be transplanted and function. The occurrence of calcification after implantation may lead to graft failure, particularly compromising the long-term patency of small-diameter grafts. Therefore, focusing on the research of calcification mechanisms and anti-calcification strategies for artificial blood vessels is of great importance. In this paper, we summarized the possible calcification mechanisms of artificial vessels and methods to prevent or delay post-implantation calcification, with the aim of providing insights for future research on anti-calcification artificial vessels.

  • Open Access

    The application of KI.C57-ras2.0 mouse in the carcinogenicity evaluation of medical devices—carcinogenicity evaluation of a novel hemodialyzer

    by Han Wang, Yu-Ting Chen, Chang-Jun Mu, Zhu Meng, Chen-Yu Zhao, Liu Yang, Rui-Qin Guan, Rui Wang, Fan-Shan Qiu, Dan-Dan Chen, et al.

    Alternative transgenic mouse models, such as rasH2, have been developed as to replace the traditional 2-year rodent carcinogenicity study. However, due to high cost, reliance on imports, and unpredictable supply chains, these transgenic mouse models have not yet been widely adopted for carcinogenicity evaluations of medical devices in China. KI.C57-ras2.0 mice, which possess independent intellectual property rights in China, were employed to evaluate the carcinogenicity of a new hemodialyzer. A total of 110 KI.C57-ras2.0 mice were divided into three groups including positive control (PC) group, negative control (NC) group and sample extracts (SE) group. Animals in the PC group were injected with MNU intraperitoneally at the concentration of 75 mg/kg for a single time. Animals in the SE and NC group were injected intraperitoneally with sample solution and 0.9% sodium chloride, the injection volume was 20 ml/kg BW, 6 days per week, and the entire administration period was 26 weeks. The survival rates of mice in PC group, NC group and SE group were 16.7%, 93.3% and 92.0%, respectively. Tumour incidence rates were 100.00%, 13.33% and 12.00%; the incidences of benign tumour were 10.00%, 3.33% and 6.00%; the incidences of malignant tumour were 90.00%, 10.00% and 6.00%; the incidences of multiple tumour was 86.67%, 0.00% and 0.00%; the average number of tumours were 8.67 ± 5.97, 0.10 ± 0.31 and 0.10 ± 0.30, respectively. There was no statistical difference in the above indexes between SE group and NC group, and there was no significant correlation between tumour lesions of all genders in SE group. Therefore, there is no carcinogenicity in this hemodialyzer. This new hemodialyzer had no carcinogenicity under this experimental condition. This study also improved the biological evaluation system of medical devices. As an animal model with great application prospects, we believe that KI.C57-ras2.0 mice will be an indispensable model animal for the evaluation of medical devices in the future, and facilitated the marketing of new biomaterials and medical devices.

  • Open Access

    A Poly-γ-Glutamic Acid/ε-Polylysine Hydrogel: Synthesis, Characterization, and Its Role in Accelerated Wound Healing

    by Jiaqi Li, Yuanli Huang, Yalu Wang, Qianqian Han

    Wound healing is a complex biological process involving inflammation, proliferation, and remodeling phases. Effective healing is essential for maintaining skin integrity, driving the need for advanced materials like hydrogels, known for their high water retention and tunable mechanical properties. In this study, we synthesized a biocompatible composite hydrogel composed of γ-polyglutamic acid (γ-PGA) and ε-polylysine (ε-PL) through a Schiff base reaction, forming a stable crosslinked network. Its physicochemical properties, including rheological behavior and swelling capacity, were systematically evaluated. Biocompatibility was assessed via in vitro hemolysis and cytotoxicity assays, and in vivo testing was performed using a full-thickness skin defect model in Sprague Dawley (SD) rats to evaluate wound-healing efficacy. The PGA-PL hydrogel demonstrated excellent physicochemical properties, with a maximum swelling ratio of 65.6%, and biocompatibility as evidenced by low hemolysis rates (80%). It promoted wound healing by inhibiting the inflammatory response, reducing levels of the inflammatory cytokine IL-6, enhancing angiogenesis, and accelerating collagen deposition. The hydrogel showed complete biodegradation within 21 days in vivo without inducing a significant inflammatory response and significantly accelerated wound healing, achieving an 86% healing rate within 7 days compared to 67% in the control group. The PGA-PL composite hydrogel exhibits excellent mechanical strength and biocompatibility, and its effective wound-healing capabilities lay the groundwork for future development and optimization in various tissue engineering applications.


  • Open Access

    Promotion of angiogenesis and suppression of inflammatory response in skin wound healing using exosome-loaded collagen sponge

    by Siqi Zhang, Xugang Lu, Jun Chen, Shibing Xiong, Yifan Cui, Simeng Wang, Chongxia Yue, Qianqian Han, Bangcheng Yang

    Effectively promoting skin wound healing remains a significant challenge in the medical field. Although stem cell-derived exosomes show potential in tissue regeneration, their local delivery and sustained release face challenges. To address these issues, we developed a collagen sponge based on type I and recombinant humanized type III collagen. Our study confirmed that exosomes were successfully loaded onto the sponge (sponge-Exo) and the sponge-Exo gradually released exosomes into the local milieu. The sponge-Exo played a crucial role in promoting the transition of macrophages from an inflammatory M1 phenotype to a regenerative M2 phenotype. Moreover, it enhanced the migration and proliferation of HDFs and promoted angiogenesis in HUVECs. Additionally, our findings revealed that the sponge-Exo accelerated wound healing by suppressing inflammatory response and stimulating angiogenesis in a rat full-thickness skin wounds model. Next generation sequencing (NGS) was used to explore the underlying mechanism of wound healing, and the results showed that the miRNAs (hsa-miR-21-5p and hsa-miR-29a-5p) associated with wound healing in exosomes were significantly up-regulated. These results highlight the remarkable effects of sponge-Exo on macrophage transformation, cell migration, proliferation and angiogenesis, which provide a potential prospect for the application in the field of skin wound healing.


  • Effectiveness and Biocompatibility Evaluation of a Novel Absorbable Bone Wax Used in Bone Tissue

    by Rui Wang, Zejian Jin, Jianfeng Gao, Yan Ma, Qianqian Han

    This study aims to determine the hemostatic effectivity and biocompatibility of a novel absorbable bone wax in comparison with a commercially available product. Eighteen small fat-tail sheep were used to simulate clinical surface bleeding of sternal injury. Hemostasis effectiveness, the degree of bone healing, micro-computed tomography, and histopathology were evaluated over a period after the application of the material to the surgically created wound. The absorbable bone wax used in the study stopped bleeding immediately and did not affect bone healing. The histopathological results also showed that there were no complications associated with the new material. The results showed that the new absorbable bone wax used in this study was effective and biocompatible.


  • Open Access

    Non-Covalent Cross-Linking Hydrogel: A New Method for Visceral Hemostasis

    by Chenyu Zhao, Han Wang, Xue Sun, Ying Liu, Jingjing Chen, Jiaqi Li, Fanshan Qiu, Qianqian Han

    Excessive blood loss could lead to pathological conditions such as tissue necrosis, organ failure, and death. The limitations of recently developed hemostatic approaches, such as their low mechanical strength, inadequate wet tissue adhesion, and weak hemostatic activity, pose challenges for their application in controlling visceral bleeding. In this study, a novel hydrogel (CT) made of collagen and tannic acid (TA) was proposed. By altering the proportions between the two materials, the mechanical properties, adhesion, and coagulation ability were evaluated. Compared to commercial hydrogels, this hydrogel has shown reduced blood loss and shorter hemostatic time in rat hepatic and cardiac bleeding models. This was explained by the hydrogel’s natural hemostatic properties and the significant benefits of wound closure in a moist environment. Better biodegradability was achieved through the non-covalent connection between tannic acid and collagen, allowing for hemostasis without hindering subsequent tissue repair. Therefore, this hydrogel is a new method for visceral hemostasis that offers significant advantages in treating acute wounds and controlling major bleeding. And the production method is simple and efficient, which facilitates its translation to clinical applications.


  • Open Access

    Spike structure of gold nanobranches induces hepatotoxicity in mouse hepatocyte organoid models

    by Rui Zhang, Dan Li, Ruibo Zhao, Dandan Luo, Yeting Hu, Shengyan Wang, Xiaolu Zhuo, M. Zubair Iqbal, Han Zhang, Qianqian Han, et al.

    Background: Gold nanoparticles (GNPs) have been extensively recognized as an active candidate for a large variety of biomedical applications. However, the clinical conversion of specific types of GNPs has been hindered due to their potential liver toxicity. The origin of their hepatotoxicity and the underlying key factors are still ambiguous. Because the size, shape, and surfactant of GNPs all affect their properties and cytotoxicity. An effective and sensitive platform that can provide deep insights into the cause of GNPs’ hepatotoxicity in vitro is therefore highly desired. Methods: Here, hepatocyte organoid models (Hep-orgs) were constructed to evaluate the shape-dependent hepatotoxicity of GNPs. Two types of GNPs with different nanomorphology, gold nanospheres (GNSs) and spiny gold nanobranches (GNBs), were synthesized as the representative samples. Their shape-dependent effects on mice Hep-orgs’ morphology, cellular cytoskeletal structure, mitochondrial structure, oxidative stress, and metabolism were carefully investigated. Results: The results showed that GNBs with higher spikiness and tip curvature exhibited more significant cytotoxicity compared to the rounded GNSs. The spike structure of GNBs leads to a mitochondrial damage, oxidative stress, and metabolic disorder in Hep-orgs. Meanwhile, similar trends can be observed in HepG2 cells and mice models, demonstrating the reliability of the Hep-orgs. Conclusions: Hep-orgs can serve as an effective platform for exploring the interactions between GNPs and liver cells in a 3D perspective, filling the gap between 2D cell models and animal models. This work further revealed that organoids can be used as an indispensable tool to rapidly screen and explore the toxic mechanism of nanomaterials before considering their biomedical functionalities.