Cornel Zachiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cornel Zachiu has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Bas W Raaymakers
Radiotherapy, University Medical Centre Utrecht, Heidelberglaan 100, Utrecht, 3584 CX, NETHERLANDS
7 shared publicationsBaudouin Denis de Senneville
Department of Radiotherapy UMC Utrecht Utrecht The Netherlands
7 shared publicationsMario G Ries
Imaging Division, UMC Utrecht, Heidelberglaan 100, 3508 GA Utrecht
5 shared publicationsMario Ries
Imaging Division, University Medical Centre Utrecht, Heidelberglaan 100, Utrecht, 3584 CX, NETHERLANDS
5 shared publicationsBas W. Raaymakers
4 shared publications- Mario Ries
Imaging Division, UMC Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
4 shared publications
Latest Publications
- Open Access
- 2 August 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 40
Deep learning-enhanced image registration for accelerating daily adaptive magnetic resonance imaging-guided prostate radiotherapy
- 2 August 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 40
Open AccessDeep learning-enhanced image registration for accelerating daily adaptive magnetic resonance imaging-guided prostate radiotherapy
- Open Access
- 13 July 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 40
A framework for planning organ at risk volume margin derivation for the small bowel during magnetic resonance-guided radiotherapy
- 13 July 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 40
Open AccessA framework for planning organ at risk volume margin derivation for the small bowel during magnetic resonance-guided radiotherapy
- Open Access
- 6 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (5) , 055007
A Bayesian framework for the detection of physiological pulmonary ventilation changes
Objective. The assessment of regional ventilation changes from functional ventilation data can provide essential information regarding treatment response in lung cancer radiotherapy (RT). However, this task can be challenging since ventilation maps contain noisy measurements and artifacts. Approach. We introduce a Bayesian framework that identifies physiological changes from a set of longitudinal ventilation scans. The proposed framework was calibrated and validated using synthetic datasets. Its ability to correctly classify regions of true change was evaluated using the sensitivity, precision and Dice Similarity coefficient. We also applied our model to a dataset comprising 11 lung cancer patients for whom multiple 4DCT scans were obtained during the course of RT treatment. CT-derived ventilation maps were generated and used as input to the proposed framework. In order to create a control dataset where no functional changes were expected, we also shuffled the time points for the 11 patients in every possible way that discarded as much temporal information as possible resulting in 128 functional map sequences. Main results. In the synthetic validation dataset, the average (standard deviation) of the sensitivity, precision and Dice Similarity coefficient was 0.72 (0.26), 0.95(0.05) and 0.78 (0.22) respectively. In the patient dataset, 3/11 patients were identified with significant functional decline and 4/11 with functional increase that was associated with tumor regression. Finally, in the control dataset the frequency of occurrence of significant changes was 1.6% (4/256) compared to 32% (7/22) for the original patient dataset. Significance. We have developed a framework for analyzing functional ventilation changes from longitudinal data. The results of the lung cancer patient dataset indicate that significant functional increase and decline can occur during the course of RT treatment. More generally, the developed framework can be used to assess ventilation changes with the potential of guiding adaptive treatment strategies.
- 6 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (5) , 055007
Open AccessA Bayesian framework for the detection of physiological pulmonary ventilation changes
Objective. The assessment of regional ventilation changes from functional ventilation data can provide essential information regarding treatment response in lung cancer radiotherapy (RT). However, this task can be challenging since ventilation maps contain noisy measurements and artifacts. Approach. We introduce a Bayesian framework that identifies physiological changes from a set of longitudinal ventilation scans. The proposed framework was calibrated and validated using synthetic datasets. Its ability to correctly classify regions of true change was evaluated using the sensitivity, precision and Dice Similarity coefficient. We also applied our model to a dataset comprising 11 lung cancer patients for whom multiple 4DCT scans were obtained during the course of RT treatment. CT-derived ventilation maps were generated and used as input to the proposed framework. In order to create a control dataset where no functional changes were expected, we also shuffled the time points for the 11 patients in every possible way that discarded as much temporal information as possible resulting in 128 functional map sequences. Main results. In the synthetic validation dataset, the average (standard deviation) of the sensitivity, precision and Dice Similarity coefficient was 0.72 (0.26), 0.95(0.05) and 0.78 (0.22) respectively. In the patient dataset, 3/11 patients were identified with significant functional decline and 4/11 with functional increase that was associated with tumor regression. Finally, in the control dataset the frequency of occurrence of significant changes was 1.6% (4/256) compared to 32% (7/22) for the original patient dataset. Significance. We have developed a framework for analyzing functional ventilation changes from longitudinal data. The results of the lung cancer patient dataset indicate that significant functional increase and decline can occur during the course of RT treatment. More generally, the developed framework can be used to assess ventilation changes with the potential of guiding adaptive treatment strategies.
- Open Access
- 26 January 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
Real-time dose reconstruction and dose coverage forecasting using the magnetic resonance linear accelerator
- 26 January 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
Open AccessReal-time dose reconstruction and dose coverage forecasting using the magnetic resonance linear accelerator
- Open Access
- 28 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (7)
Bowel tracking for MR-guided radiotherapy: simultaneous optimization of small bowel imaging and tracking
Background and purpose The small bowel is one of the most radiosensitive organs-at-risk during radiotherapy in the pelvis. This is further complicated due to anatomical and physiological motion. Thus, its accurate tracking becomes of particular importance during therapy delivery, to obtain better dose-toxicity relations and/or to perform safe adaptive treatments. The aim of this work is to simultaneously optimize the MR imaging sequence and motion estimation solution towards improved small bowel tracking precision during radiotherapy delivery. Materials and methods An MRI sequence was optimized, to adhere to the respiratory and peristaltic motion frequencies, by assesing the performance of an image registration algorithm on data acquired on volunteers and patients. In terms of tracking, three registration algorithms, previously-employed in the scope of image-guided radiotherapy, were investigated. The optimized scan was acquired for 7.5 min., in 18 patients and for 15 min., in 10 volunteers at a 1.5T MRL (Unity, Elekta AB). The tracking precision was evaluated and validated by means of three different quality assurance criteria: Structural Similarity Index Metric (SSIM), Inverse Consistency (IC) and Absolute Intensity Difference (AID). Results The optimal sequence was a balanced Fast Field Echo (FFE), which acquired a 3D volume of the abdomen, with a dynamic scan time of 1.8 seconds. An optical flow algorithm performed best and which was able to resolve most of the motion. This was shown by mean IC values of < 1 mm and a mean SSIM >0.9 for the majority of the cases. A strong positive correlation (p<0.001) between the registration performance and visceral fat percentage was found, where a higher visceral fat percentage gave a better registration due to the better image contrast. Conclusions A method for simultaneous optimization of imaging and tracking was presented, which derived an imaging and registration procedure for accurate small bowel tracking on the MR-Linac.
- 28 February 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (7)
Open AccessBowel tracking for MR-guided radiotherapy: simultaneous optimization of small bowel imaging and tracking
Background and purpose The small bowel is one of the most radiosensitive organs-at-risk during radiotherapy in the pelvis. This is further complicated due to anatomical and physiological motion. Thus, its accurate tracking becomes of particular importance during therapy delivery, to obtain better dose-toxicity relations and/or to perform safe adaptive treatments. The aim of this work is to simultaneously optimize the MR imaging sequence and motion estimation solution towards improved small bowel tracking precision during radiotherapy delivery. Materials and methods An MRI sequence was optimized, to adhere to the respiratory and peristaltic motion frequencies, by assesing the performance of an image registration algorithm on data acquired on volunteers and patients. In terms of tracking, three registration algorithms, previously-employed in the scope of image-guided radiotherapy, were investigated. The optimized scan was acquired for 7.5 min., in 18 patients and for 15 min., in 10 volunteers at a 1.5T MRL (Unity, Elekta AB). The tracking precision was evaluated and validated by means of three different quality assurance criteria: Structural Similarity Index Metric (SSIM), Inverse Consistency (IC) and Absolute Intensity Difference (AID). Results The optimal sequence was a balanced Fast Field Echo (FFE), which acquired a 3D volume of the abdomen, with a dynamic scan time of 1.8 seconds. An optical flow algorithm performed best and which was able to resolve most of the motion. This was shown by mean IC values of < 1 mm and a mean SSIM >0.9 for the majority of the cases. A strong positive correlation (p<0.001) between the registration performance and visceral fat percentage was found, where a higher visceral fat percentage gave a better registration due to the better image contrast. Conclusions A method for simultaneous optimization of imaging and tracking was presented, which derived an imaging and registration procedure for accurate small bowel tracking on the MR-Linac.
- Open Access
- 31 January 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100711
Added value of non-rigid image registration for intrafraction dose accumulation in magnetic resonance imaging-guided prostate radiotherapy
- 31 January 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100711
Open AccessAdded value of non-rigid image registration for intrafraction dose accumulation in magnetic resonance imaging-guided prostate radiotherapy
- Open Access
- 30 January 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100706
Dose-volume parameter evaluation of a sub-fractionation workflow for adaptive radiotherapy of prostate cancer patients on a 1.5 T magnetic resonance imaging radiotherapy system
- 30 January 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 33, 100706
Open AccessDose-volume parameter evaluation of a sub-fractionation workflow for adaptive radiotherapy of prostate cancer patients on a 1.5 T magnetic resonance imaging radiotherapy system
- Open Access
- 15 September 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 200, 110541
Automated dose evaluation on daily cone-beam computed tomography for breast cancer patients
- 15 September 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 200, 110541
Open AccessAutomated dose evaluation on daily cone-beam computed tomography for breast cancer patients
- Open Access
- 17 May 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 30, 100588
A multi-institutional comparison of retrospective deformable dose accumulation for online adaptive magnetic resonance-guided radiotherapy
- 17 May 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 30, 100588
Open AccessA multi-institutional comparison of retrospective deformable dose accumulation for online adaptive magnetic resonance-guided radiotherapy
- Open Access
- 26 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015020
SOLID: a novel similarity metric for mono-modal and multi-modal deformable image registration
Medical image registration is an integral part of various clinical applications including image guidance, motion tracking, therapy assessment and diagnosis. We present a robust approach for mono-modal and multi-modal medical image registration. To this end, we propose the novel shape operator based local image distance (SOLID) which estimates the similarity of images by comparing their second-order curvature information. Our similarity metric is rigorously tailored to be suitable for comparing images from different medical imaging modalities or image contrasts. A critical element of our method is the extraction of local features using higher-order shape information, enabling the accurate identification and registration of smaller structures. In order to assess the efficacy of the proposed similarity metric, we have implemented a variational image registration algorithm that relies on the principle of matching the curvature information of the given images. The performance of the proposed algorithm has been evaluated against various alternative state-of-the-art variational registration algorithms. Our experiments involve mono-modal as well as multi-modal and cross-contrast co-registration tasks in a broad variety of anatomical regions. Compared to the evaluated alternative registration methods, the results indicate a very favorable accuracy, precision and robustness of the proposed SOLID method in various highly challenging registration tasks.
- 26 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015020
Open AccessSOLID: a novel similarity metric for mono-modal and multi-modal deformable image registration
Medical image registration is an integral part of various clinical applications including image guidance, motion tracking, therapy assessment and diagnosis. We present a robust approach for mono-modal and multi-modal medical image registration. To this end, we propose the novel shape operator based local image distance (SOLID) which estimates the similarity of images by comparing their second-order curvature information. Our similarity metric is rigorously tailored to be suitable for comparing images from different medical imaging modalities or image contrasts. A critical element of our method is the extraction of local features using higher-order shape information, enabling the accurate identification and registration of smaller structures. In order to assess the efficacy of the proposed similarity metric, we have implemented a variational image registration algorithm that relies on the principle of matching the curvature information of the given images. The performance of the proposed algorithm has been evaluated against various alternative state-of-the-art variational registration algorithms. Our experiments involve mono-modal as well as multi-modal and cross-contrast co-registration tasks in a broad variety of anatomical regions. Compared to the evaluated alternative registration methods, the results indicate a very favorable accuracy, precision and robustness of the proposed SOLID method in various highly challenging registration tasks.