EÖErhan Özyol

Erhan Özyol

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Erhan Özyol has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Pelin Özyol

    Department of Ophthalmology, Mugla Sitki Kocman University, Faculty of Medicine, Mugla, Turkey

    5 shared publications
  • Beyza Doğanay Erdoğan

    Faculty of Medicine, Department of Biostatistics, Ankara University, Ankara, Turkey

    1 shared publication
  • Mehmet Önen

    Department of Ophthalmology, Numune Training and Research Hospital, Ankara, Turkey

    1 shared publication

Latest Publications

  • Open Access

    Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology

    by Erhan Ozyol, Pelin Özyol

    Purpose: The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. Materials and Methods: In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-domain OCT (SD-OCT) device with an anterior segment module (Spectralis), and noncontact pachymetry (NCP) device (Topcon TRK-2P). Agreement among the devices was analyzed using mean differences (i.e., bias) and Bland–Altman analysis with 95% limits of agreement (LoA). Results: Mean CCT measurements were 537.5 ± 47.5 μm for SS-OCT optical biometer, 532.3 ± 43.8 μm for Scheimpflug system, 521.3 ± 44.7 μm for SD-OCT device, and 518.0 ± 43.1 μm for NCP (P < 0.001). The SD-OCT device and NCP showed the closest agreement, with a bias of 2.6 μm (95% LoA, −3.6–8.8 μm), whereas the SS-OCT optical biometer and NCP showed the least agreement, with a bias of 18.7 μm (95% LoA, −2.1–39.5 μm). Bias was 16.1 μm (95% LoA, −3.1–35.3 μm) for SS-OCT optical biometer and SD-OCT, 5.1 μm (95% LoA, −6.8–17.0 μm) for SS-OCT optical biometer and Scheimpflug system, 10.9 μm (95% LoA, −15.1–36.9 μm) for SD-OCT device and Scheimpflug system, and 13.6 μm (95% LoA, −5–32.2 μm) for Scheimpflug system and NCP. Conclusions: SS-OCT optical biometer overestimates CCT measurements compared to Scheimpflug system, SD-OCT device, and NCP. Given mean differences and range variations in CCT measurements between devices, SS-OCT optical biometer and Scheimpflug system are interchangeable as are SD-OCT and NCP.


  • Open Access

    Hydro-visco-implantation Technique for Wound-assisted Foldable Intraocular Lens Implantation During Microincision Cataract Surgery

    by E Ozyol

    Journal of Addiction Medicine and Therapeutic Science is an international, open access, a peer reviewed academic and distinguished journal which covers the outstanding and most update research works/peak quality papers on related to clinical prevention and treatment to harmful alcohol, tobacco, and other drug use diagonally the spectrum of clinical settings.

  • The role of anterior hyaloid face integrity on retinal complications during Nd: YAG laser capsulotomy

    by Erhan Özyol, Pelin Özyol, Beyza Doğanay Erdoğan, Mehmet Önen

    Background This study evaluated anterior hyaloid damage (AHD), AHD-related Nd:YAG laser parameters, and retinal complications in subjects that underwent Nd:YAG laser posterior capsulotomy for cataracts. Methods In this prospective, cross-sectional study, 277 pseudophakic eyes of 216 patients treated with Nd:YAG laser capsulotomy for posterior capsule opacification were enrolled. Pulse number, pulse energy, and total energy were noted for each eye. All procedures were performed with a sense of anterior hyaloid protection. Anterior hyaloid faces were assessed during procedure and 1 day after the procedure. Eyes with biomicroscopically invisible anterior hyaloid face were excluded from statistical analysis. Eyes with and without AHD were compared according to Nd:YAG laser parameters. Retinal complications were evaluated at day 1, week 1, month 1, and month 3. Results In 22 eyes (7.9 % of 277 eyes), the anterior hyaloid face couldn’t be assessed biomicroscopically. Anterior hyaloid damage was observed in 49 eyes (19.2 % of 255 eyes). The pulse number, pulse energy, and total energy were observed to be higher in eyes with AHD (P < .001, P = .024, P < .001, respectively). Cystoid macular edema was detected in five eyes (three with AHD) at 1-week examination. Localized retinal detachment occurred in one eye with AHD. Occurrence of retinal complication in the AHD(+) group was 12.7 times higher than in the AHD(−) group, adjusted for total energy used (P < 0.001). Conclusion The risk of AHD may increase with high pulse number, pulse energy, and total energy. Anterior hyaloid face integrity should be considered for YAG laser-related retinal complications.


  • The relation between superior phacoemulsification incision and steep axis on astigmatic outcomes

    by Erhan Özyol, Pelin Özyol

    To evaluate the relation between superior phacoemulsification incision and different steep axis on astigmatism outcomes. This prospective, randomized study comprised three groups each with 24 eyes with age-related cataracts and underwent 3.0 mm superior clear corneal incision (CCI). The three groups of the patients were divided by the location of the steep axis. The steep axis was between 0 and 30° in group 1, 31–60° in group 2, 61–90° in group 3. The degree was accepted as the distance from the steep axis to the distal aspect of the wound. Outcome measures were including the changes in mean total astigmatism, surgically-induced astigmatism (SIA), axis deviation, uncorrected visual acuity (UCVA), and best corrected visual acuity (BCVA). Astigmatism was measured by manuel keratometry readings before surgery and day-1, week-1, week-2, week-4 and week-8 postoperatively. The surgically-induced astigmatism was calculated by the vector analysis using the Holladay–Cravy–Koch method. The magnitude of mean total astigmatism was lowest in group 1 and highest in group 3 at 8th week. Surgically-induced astigmatism was 0.52 diopter (D), 0.88 D, 1.03 D in group 1, group 2, and group 3 respectively. The change in SIA was significant in group 1 (P < 0.05). The change in the astigmatic axis deviation was highest in group 1 (31.5 ± 31.3, P < 0.05). The mean UCVA and BCVA were not significant pre and postoperatively between groups (P > 0.05). Axis deviation and SIA were stable after the week-1 and week-2 examinations respectively. Cataract surgery with CCI on or near the steep axis is resulted in decreased SIA and increased axis deviation.