Philipp Sommer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Philipp Sommer has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Andreas Bollmann
Department of Electrophysiology, University of Leipzig-Heart Center, Leipzig, Germany
1 shared publication- Andreas Bollmann
Department of Electrophysiology, Heart Center Leipzig, Leipzig University, Strümpellstr. 39, 04289, Leipzig, Germany
1 shared publication Arash Arya
Department of Electrophysiology, University of Leipzig-Heart Center, Leipzig, Germany
1 shared publication- Arash Arya
Department of Electrophysiology, Heart Center Leipzig, Leipzig University, Strümpellstr. 39, 04289, Leipzig, Germany
1 shared publication Borislav Dinov
Department of Electrophysiology, University of Leipzig-Heart Center, Leipzig, Germany
1 shared publication- Borislav Dinov
Department of Electrophysiology, Heart Center Leipzig, Leipzig University, Strümpellstr. 39, 04289, Leipzig, Germany
1 shared publication
Latest Publications
- 31 May 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (12) , 2045
Approaches to lower radiation dose in atrial fibrillation ablation: Authors’ reply
I couldn’t agree more with your opinion.1 There are different ways to achieve near-zero or zero fluoroscopy procedures in atrial fibrillation ablations—and some of them are quite challenging from a technical or technological point of view: intracardiac echo, transesophageal echocardiography-guided ablations, and innovations like non-fluoroscopic catheter visualization technologies. Not producing radiation by educating our fellows and ourselves and to create awareness is one important step: low fluoroscopy times should be seen as a marker of quality in an electrophysiology procedure.2 But probably the way to save the greatest amount of radiation was correctly mentioned by you: to modify the settings of the X-ray systems. Low frame...
- 31 May 2018
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (12) , 2045
Approaches to lower radiation dose in atrial fibrillation ablation: Authors’ reply
I couldn’t agree more with your opinion.1 There are different ways to achieve near-zero or zero fluoroscopy procedures in atrial fibrillation ablations—and some of them are quite challenging from a technical or technological point of view: intracardiac echo, transesophageal echocardiography-guided ablations, and innovations like non-fluoroscopic catheter visualization technologies. Not producing radiation by educating our fellows and ourselves and to create awareness is one important step: low fluoroscopy times should be seen as a marker of quality in an electrophysiology procedure.2 But probably the way to save the greatest amount of radiation was correctly mentioned by you: to modify the settings of the X-ray systems. Low frame...
- Open Access
- 5 April 2017
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 15 (1) , 1-6
Association of atrial fibrillation susceptibility genes, atrial fibrillation phenotypes and response to catheter ablation: a gene-based analysis of GWAS data
Previous studies have suggested PITX2, KCNN3 and ZFHX3 as atrial fibrillation (AF) susceptibility genes. Single common genetic polymorphisms of those genes have been linked with AF phenotypes and rhythm outcome of AF catheter ablation although their mechanisms remain elusive. New gene-based association tests may help clarifying genotype–phenotype correlations. Therefore, we hypothesized that PITX2, KCNN3 and ZFHX3 associate with left atrial enlargement and persistent AF and subsequently with ablation outcome. Samples from 660 patients with paroxysmal (n = 370) or persistent AF (n = 290) undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using two different gene-based association tests (VEGAS, minSNP). Among the three candidate genes, only ZFHX3 associated with left atrial dilatation and AF recurrence after catheter ablation. This study suggests a contribution of ZFHX3 to AF remodeling and response to therapy. Future and larger studies are necessary to replicate and apply these findings with an emphasis on designing AF pathophysiology-based multi-locus risk scores.
- 5 April 2017
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 15 (1) , 1-6
Open AccessAssociation of atrial fibrillation susceptibility genes, atrial fibrillation phenotypes and response to catheter ablation: a gene-based analysis of GWAS data
Previous studies have suggested PITX2, KCNN3 and ZFHX3 as atrial fibrillation (AF) susceptibility genes. Single common genetic polymorphisms of those genes have been linked with AF phenotypes and rhythm outcome of AF catheter ablation although their mechanisms remain elusive. New gene-based association tests may help clarifying genotype–phenotype correlations. Therefore, we hypothesized that PITX2, KCNN3 and ZFHX3 associate with left atrial enlargement and persistent AF and subsequently with ablation outcome. Samples from 660 patients with paroxysmal (n = 370) or persistent AF (n = 290) undergoing AF catheter ablation were genotyped for ~1,000,000 SNPs. Gene-based association was investigated using two different gene-based association tests (VEGAS, minSNP). Among the three candidate genes, only ZFHX3 associated with left atrial dilatation and AF recurrence after catheter ablation. This study suggests a contribution of ZFHX3 to AF remodeling and response to therapy. Future and larger studies are necessary to replicate and apply these findings with an emphasis on designing AF pathophysiology-based multi-locus risk scores.
- 3 November 2015
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (3) , 274-280
Successful Repeat Catheter Ablation of Recurrent Longstanding Persistent Atrial Fibrillation With Rotor Elimination as the Procedural Endpoint: A Case Series
Background There remains a lack of consensus regarding the ideal ablation strategy for atrial fibrillation (AF), particularly in patients with persistent or longstanding persistent AF. Given increasing evidence from clinical imaging studies that rotors sustain AF, rotor elimination may be a desirable procedural endpoint. However, there is no description to date of the clinical outcomes using rotor elimination during ablation as the procedural endpoint. Moreover, a series of studies question whether procedural AF termination is a desirable endpoint for ablation after many forms of AF ablation. Methods and Results We report a single‐center experience of rotor elimination during AF ablation using Focal Impulse and Rotor Mapping (FIRM), describing 20 consecutive patients with case descriptions of 3 patients with recurrent longstanding persistent AF after prior ablation. In all cases, endocardial mapping using a 64‐electrode basket catheter was performed to identify rotors, which were eliminated using radiofrequency catheter ablation. After it was verified that all identified rotors were eliminated, standard ablation consisting of PV isolation was performed. Notably, persistent AF terminated in only 1/20 (5%) patients. However, after a follow‐up of 6 months, single‐procedure freedom from AF was 80% (16/20 patients) with only 1 patient on antiarrhythmic drugs. All three patients in the highlighted series are AF free despite the lack of acute procedural AF termination. Conclusions Patients with persistent AF including those with unsuccessful prior ablation can be treated successfully by rotor targeted ablation, using the elimination of all rotors rather than acute AF termination as the procedural endpoint.
- 3 November 2015
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (3) , 274-280
Successful Repeat Catheter Ablation of Recurrent Longstanding Persistent Atrial Fibrillation With Rotor Elimination as the Procedural Endpoint: A Case Series
Background There remains a lack of consensus regarding the ideal ablation strategy for atrial fibrillation (AF), particularly in patients with persistent or longstanding persistent AF. Given increasing evidence from clinical imaging studies that rotors sustain AF, rotor elimination may be a desirable procedural endpoint. However, there is no description to date of the clinical outcomes using rotor elimination during ablation as the procedural endpoint. Moreover, a series of studies question whether procedural AF termination is a desirable endpoint for ablation after many forms of AF ablation. Methods and Results We report a single‐center experience of rotor elimination during AF ablation using Focal Impulse and Rotor Mapping (FIRM), describing 20 consecutive patients with case descriptions of 3 patients with recurrent longstanding persistent AF after prior ablation. In all cases, endocardial mapping using a 64‐electrode basket catheter was performed to identify rotors, which were eliminated using radiofrequency catheter ablation. After it was verified that all identified rotors were eliminated, standard ablation consisting of PV isolation was performed. Notably, persistent AF terminated in only 1/20 (5%) patients. However, after a follow‐up of 6 months, single‐procedure freedom from AF was 80% (16/20 patients) with only 1 patient on antiarrhythmic drugs. All three patients in the highlighted series are AF free despite the lack of acute procedural AF termination. Conclusions Patients with persistent AF including those with unsuccessful prior ablation can be treated successfully by rotor targeted ablation, using the elimination of all rotors rather than acute AF termination as the procedural endpoint.