François Beloncle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
François Beloncle has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
- Arnaud Gacouin
Service de Médecine Intensive-Réanimation, CHU de Rennes, Université de Rennes, Rennes, France
3 shared publications - Arnaud Wilfrid Thille
Service de Médecine Intensive Réanimation, CHU de Poitiers, Poitiers, France
3 shared publications - Jean-Pierre Frat
CHU de Poitiers, Médecine Intensive Réanimation, Poitiers, France
3 shared publications - Peter Radermacher
Institut für Anästhesiologische Pathophysiologie und Verfahrensentwicklung, Universitätsklinikum, Ulm, Germany
3 shared publications - Pierre Asfar
Department of Medical Intensive Care, University Hospital of Angers, CARE, SFR ICAT, Angers, France
3 shared publications - Rémi Coudroy
Médecine Intensive Réanimation, CHU de Poitiers, Poitiers, France
3 shared publications
Latest Publications
- Open Access
Effect of high-flow nasal cannula oxygen versus standard oxygen on mortality in patients with acute hypoxaemic respiratory failure: protocol for a multicentre, randomised controlled trial (SOHO)
Introduction First-line oxygenation strategy in patients with acute hypoxaemic respiratory failure consists in standard oxygen or high-flow nasal oxygen therapy. Clinical practice guidelines suggest the use of high-flow nasal oxygen rather than standard oxygen. However, findings remain contradictory with a low level of certainty. We hypothesise that compared with standard oxygen, high-flow nasal oxygen may reduce mortality in patients with acute hypoxaemic respiratory failure. Method and analysis The Standard Oxygen versus High-flow nasal Oxygen-trial is an investigator-initiated, multicentre, open-label, randomised controlled trial comparing high-flow nasal oxygen versus standard oxygen in patients admitted to an intensive care unit (ICU) for acute respiratory failure with moderate-to-severe hypoxaemia. 1110 patients will be randomly assigned to one of the two groups with a ratio of 1:1. The primary outcome is the number of patients who died 28 days after randomisation. Secondary outcomes include comfort, dyspnoea and oxygenation 1 hour after treatment initiation, the number of patients intubated at day 28, mortality in ICU, in hospital and until day 90, and complications during ICU stay. Ethics and dissemination The study has been approved by the central Ethics Committee ‘Sud Méditerranée III’ (2020-07-05) and patients will be included after informed consent. The results will be submitted for publication in peer-reviewed journals. Trial registration number NCT04468126.
Open AccessEffect of high-flow nasal cannula oxygen versus standard oxygen on mortality in patients with acute hypoxaemic respiratory failure: protocol for a multicentre, randomised controlled trial (SOHO)
Introduction First-line oxygenation strategy in patients with acute hypoxaemic respiratory failure consists in standard oxygen or high-flow nasal oxygen therapy. Clinical practice guidelines suggest the use of high-flow nasal oxygen rather than standard oxygen. However, findings remain contradictory with a low level of certainty. We hypothesise that compared with standard oxygen, high-flow nasal oxygen may reduce mortality in patients with acute hypoxaemic respiratory failure. Method and analysis The Standard Oxygen versus High-flow nasal Oxygen-trial is an investigator-initiated, multicentre, open-label, randomised controlled trial comparing high-flow nasal oxygen versus standard oxygen in patients admitted to an intensive care unit (ICU) for acute respiratory failure with moderate-to-severe hypoxaemia. 1110 patients will be randomly assigned to one of the two groups with a ratio of 1:1. The primary outcome is the number of patients who died 28 days after randomisation. Secondary outcomes include comfort, dyspnoea and oxygenation 1 hour after treatment initiation, the number of patients intubated at day 28, mortality in ICU, in hospital and until day 90, and complications during ICU stay. Ethics and dissemination The study has been approved by the central Ethics Committee ‘Sud Méditerranée III’ (2020-07-05) and patients will be included after informed consent. The results will be submitted for publication in peer-reviewed journals. Trial registration number NCT04468126.
- Open Access
- 28 June 2021
- Published by Springer Nature in Critical Care
- Vol. 25 (1) , 1-12
Non-invasive ventilation versus high-flow nasal oxygen for postextubation respiratory failure in ICU: a post-hoc analysis of a randomized clinical trial
Background: In intensive care units (ICUs), patients experiencing post-extubation respiratory failure have poor outcomes. The use of noninvasive ventilation (NIV) to treat post-extubation respiratory failure may increase the risk of death. This study aims at comparing mortality between patients treated with NIV alternating with high-flow nasal oxygen or high-flow nasal oxygen alone. Methods: Post-hoc analysis of a multicenter, randomized, controlled trial focusing on patients who experienced post-extubation respiratory failure within the 7 days following extubation. Patients were classified in the NIV group or the high-flow nasal oxygen group according to oxygenation strategy used after the onset of post-extubation respiratory failure. Patients reintubated within the first hour after extubation and those promptly reintubated without prior treatment were excluded. The primary outcome was mortality at day 28 after the onset of post-extubation respiratory failure. Results: Among 651 extubated patients, 158 (25%) experienced respiratory failure and 146 were included in the analysis. Mortality at day 28 was 18% (15/84) using NIV alternating with high-flow nasal oxygen and 29% (18/62) with high flow nasal oxygen alone (difference, − 11% [95% CI, − 25 to 2]; p = 0.12). Among the 46 patients with hypercapnia at the onset of respiratory failure, mortality at day 28 was 3% (1/33) with NIV and 31% (4/13) with high-flow nasal oxygen alone (difference, − 28% [95% CI, − 54 to − 6]; p = 0.006). The proportion of patients reintubated 48 h after the onset of post-extubation respiratory failure was 44% (37/84) with NIV and 52% (32/62) with high-flow nasal oxygen alone (p = 0.21). Conclusions: In patients with post-extubation respiratory failure, NIV alternating with high-flow nasal oxygen might not increase the risk of death. Trial registration number The trial was registered at http://www.clinicaltrials.gov with the registration number NCT03121482 the 20th April 2017.
- 28 June 2021
- Published by Springer Nature in Critical Care
- Vol. 25 (1) , 1-12
Open AccessNon-invasive ventilation versus high-flow nasal oxygen for postextubation respiratory failure in ICU: a post-hoc analysis of a randomized clinical trial
Background: In intensive care units (ICUs), patients experiencing post-extubation respiratory failure have poor outcomes. The use of noninvasive ventilation (NIV) to treat post-extubation respiratory failure may increase the risk of death. This study aims at comparing mortality between patients treated with NIV alternating with high-flow nasal oxygen or high-flow nasal oxygen alone. Methods: Post-hoc analysis of a multicenter, randomized, controlled trial focusing on patients who experienced post-extubation respiratory failure within the 7 days following extubation. Patients were classified in the NIV group or the high-flow nasal oxygen group according to oxygenation strategy used after the onset of post-extubation respiratory failure. Patients reintubated within the first hour after extubation and those promptly reintubated without prior treatment were excluded. The primary outcome was mortality at day 28 after the onset of post-extubation respiratory failure. Results: Among 651 extubated patients, 158 (25%) experienced respiratory failure and 146 were included in the analysis. Mortality at day 28 was 18% (15/84) using NIV alternating with high-flow nasal oxygen and 29% (18/62) with high flow nasal oxygen alone (difference, − 11% [95% CI, − 25 to 2]; p = 0.12). Among the 46 patients with hypercapnia at the onset of respiratory failure, mortality at day 28 was 3% (1/33) with NIV and 31% (4/13) with high-flow nasal oxygen alone (difference, − 28% [95% CI, − 54 to − 6]; p = 0.006). The proportion of patients reintubated 48 h after the onset of post-extubation respiratory failure was 44% (37/84) with NIV and 52% (32/62) with high-flow nasal oxygen alone (p = 0.21). Conclusions: In patients with post-extubation respiratory failure, NIV alternating with high-flow nasal oxygen might not increase the risk of death. Trial registration number The trial was registered at http://www.clinicaltrials.gov with the registration number NCT03121482 the 20th April 2017.
- Open Access
- 9 February 2021
- Published by Elsevier in Annals of Intensive Care
- Vol. 11 (1) , 1-9
Non-invasive ventilation alternating with high-flow nasal oxygen versus high-flow nasal oxygen alone after extubation in COPD patients: a post hoc analysis of a randomized controlled trial
- 9 February 2021
- Published by Elsevier in Annals of Intensive Care
- Vol. 11 (1) , 1-9
Open AccessNon-invasive ventilation alternating with high-flow nasal oxygen versus high-flow nasal oxygen alone after extubation in COPD patients: a post hoc analysis of a randomized controlled trial
- Open Access
- 17 December 2018
- Published by Elsevier in Annals of Intensive Care
- Vol. 8 (1) , 126-9
Effect on comfort of administering bubble-humidified or dry oxygen: the Oxyrea non-inferiority randomized study
- 17 December 2018
- Published by Elsevier in Annals of Intensive Care
- Vol. 8 (1) , 126-9
Open AccessEffect on comfort of administering bubble-humidified or dry oxygen: the Oxyrea non-inferiority randomized study
- Open Access
- 1 January 2017
- Published by Elsevier in Annals of Intensive Care
- Vol. 7 (1) , 66-8
Assessment of renal hemodynamic toxicity of fluid challenge with 0.9% NaCl compared to balanced crystalloid (PlasmaLyte®) in a rat model with severe sepsis
- 1 January 2017
- Published by Elsevier in Annals of Intensive Care
- Vol. 7 (1) , 66-8
Open AccessAssessment of renal hemodynamic toxicity of fluid challenge with 0.9% NaCl compared to balanced crystalloid (PlasmaLyte®) in a rat model with severe sepsis
- 11 March 2016
- Vol. 82 (7) , 777-84
Mean arterial pressure target in patients with septic shock.
In patients with septic shock, a mean arterial pressure higher than 65 mmHg is recommended by the Surviving Sepsis Campaign Guidelines. However, a precise mean arterial pressure target has not been delineated. The aim of this paper was to review the physiological rationale and clinical evidence for increasing mean arterial pressure in septic shock. A mean arterial pressure level lower than renal autoregulatory threshold may lead to renal dysfunction. However, adjusting macrocirculation objectives in particular after the early phase of septic shock may not correct established microcirculation impairments. Moreover, sympathetic over-stimulation due to high doses of vasopressor (needed to achieve high mean arterial pressure targets) may be associated with numerous harmful effects. Observational and small short term interventional studies did not provide a definitive answer to this question but suggested that a high mean arterial pressure (around 75-85 mmHg) may prevent acute kidney injury in some patients. The SEPSISPAM Trial, a large prospective, randomized, controlled study, compared the targets of High (i.e. 80 to 85 mm Hg) versus Low (i.e. 65 to 70 mm Hg) mean arterial pressure in patients with septic shock. The mortality was not different in the two groups. However in patients with chronic hypertension, there were significantly less renal failure in the high mean arterial pressure group than the low mean arterial pressure group.
- 11 March 2016
- Vol. 82 (7) , 777-84
Mean arterial pressure target in patients with septic shock.
In patients with septic shock, a mean arterial pressure higher than 65 mmHg is recommended by the Surviving Sepsis Campaign Guidelines. However, a precise mean arterial pressure target has not been delineated. The aim of this paper was to review the physiological rationale and clinical evidence for increasing mean arterial pressure in septic shock. A mean arterial pressure level lower than renal autoregulatory threshold may lead to renal dysfunction. However, adjusting macrocirculation objectives in particular after the early phase of septic shock may not correct established microcirculation impairments. Moreover, sympathetic over-stimulation due to high doses of vasopressor (needed to achieve high mean arterial pressure targets) may be associated with numerous harmful effects. Observational and small short term interventional studies did not provide a definitive answer to this question but suggested that a high mean arterial pressure (around 75-85 mmHg) may prevent acute kidney injury in some patients. The SEPSISPAM Trial, a large prospective, randomized, controlled study, compared the targets of High (i.e. 80 to 85 mm Hg) versus Low (i.e. 65 to 70 mm Hg) mean arterial pressure in patients with septic shock. The mortality was not different in the two groups. However in patients with chronic hypertension, there were significantly less renal failure in the high mean arterial pressure group than the low mean arterial pressure group.
- Open Access
- 1 January 2015
- Published by Elsevier in Annals of Intensive Care
- Vol. 5 (1) , 42-14
Hyperoxia in intensive care, emergency, and peri-operative medicine: Dr. Jekyll or Mr. Hyde? A 2015 update
- 1 January 2015
- Published by Elsevier in Annals of Intensive Care
- Vol. 5 (1) , 42-14
Open AccessHyperoxia in intensive care, emergency, and peri-operative medicine: Dr. Jekyll or Mr. Hyde? A 2015 update