Saroa Rozas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Saroa Rozas has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Raquel Idoeta
University of the Basque Country (UPV/EHU)
7 shared publications M. Herranz
Department of Energy Engineering, University of the Basque Country UPV/EHU, Faculty of Engineering in Bilbao, Plaza Ingeniero Torres Quevedo 1, 48013, Bilbao, Spain
4 shared publications- Concepción Olondo
University of the Basque Country
2 shared publications - Margarita Herranz
Energy Engineering Department, University of the Basque Country, EHU 1 Ingeniero Torres Quevedo Square, 48013 Bilbao, Spain
2 shared publications - Susana Petisco-Ferrero
Energy Engineering Department, University of the Basque Country, UPV/EHU, Plaza Torres Quevedo, s/n, 48013 Bilbao, Spain
2 shared publications A. Párraga
University of the Basque Country (UPV/EHU), Faculty of Engineering
1 shared publication
Latest Publications
- Open Access
- 9 January 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (5)
Cluster analysis of weekly 210Pb and 40K concentrations and cumulative meteorological effects in urban Spain (2006–2022)
- 9 January 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (5)
Open AccessCluster analysis of weekly 210Pb and 40K concentrations and cumulative meteorological effects in urban Spain (2006–2022)
- Open Access
- 1 June 2024
- Published by MDPI AG in Environments
- Vol. 11 (6) , 116
Proposed Detection Limits for Radioactivity Concentrations in Water in the Decommissioning and Dismantling of Nuclear Facilities
The Dismantling and Decommissioning (D&D) of nuclear facilities poses several challenges for radioactivity measurement laboratories involved in environmental radiation monitoring plans. One of them is the definition of the detection limits to be achieved for the radionuclides analysis in different samples. The detection limits should be set in such a way that the obtained concentration values for each radionuclide are easily discriminated from certain maximum activity concentration levels. These maximum activity concentration levels are usually set in view of the respective dose contributions from each radionuclide. There are some national legislations that settle detection limits for drinking water. However, there is no regulation containing detection limits for groundwater or surface water. In this way, different institutions or companies require very different detection limits for radioactivity concentration assessment in those types of water associated with D&D activities. In this work, we focus on the detection limits required for the D&D activities in rainwater, surface water and groundwater. We propose detection limits obtained by applying the WHO methodology for maximum activity concentration levels and compare with those requested by radioactive waste management agencies and regulatory bodies. Some real cases where our proposal allows identification of events are analysed and conclusions are extracted.
- 1 June 2024
- Published by MDPI AG in Environments
- Vol. 11 (6) , 116
Open AccessProposed Detection Limits for Radioactivity Concentrations in Water in the Decommissioning and Dismantling of Nuclear Facilities
The Dismantling and Decommissioning (D&D) of nuclear facilities poses several challenges for radioactivity measurement laboratories involved in environmental radiation monitoring plans. One of them is the definition of the detection limits to be achieved for the radionuclides analysis in different samples. The detection limits should be set in such a way that the obtained concentration values for each radionuclide are easily discriminated from certain maximum activity concentration levels. These maximum activity concentration levels are usually set in view of the respective dose contributions from each radionuclide. There are some national legislations that settle detection limits for drinking water. However, there is no regulation containing detection limits for groundwater or surface water. In this way, different institutions or companies require very different detection limits for radioactivity concentration assessment in those types of water associated with D&D activities. In this work, we focus on the detection limits required for the D&D activities in rainwater, surface water and groundwater. We propose detection limits obtained by applying the WHO methodology for maximum activity concentration levels and compare with those requested by radioactive waste management agencies and regulatory bodies. Some real cases where our proposal allows identification of events are analysed and conclusions are extracted.
- Open Access
- 9 June 2023
- Published by MDPI AG in Environments
- Vol. 10 (6) , 98
Quality Assurance of Potential Radioanalytical Methods for 14C in Environmental Samples
Today, the measurement of 14C in environmental samples is of particular interest, as it enables the assessment of the impact caused by nuclear activities and the fossil fuel industry on the environment. In order to assure the quality of 14C measurement results, the strategy to enlarge the validation of three radioanalytical methods in environmental samples using liquid scintillation spectrometry—the direct counting of water, bubbling of water and combustion of solids—is presented. Due certain difficulties, such as the lack of quality control materials and the scarcity of proficiency test and intercomparison exercises, especially in solid samples, a set of water and soil samples were prepared for the purpose by tracing them with known quantities of a 14C standard solution at two activity levels. Aliquots were subjected to the corresponding method and their activity concentration was calculated. Finally, uncertainty, detection limit, accuracy, precision, repeatability and linearity were analysed. The acceptance criteria for the quality parameters were previously established according to ISO 13528:2015 standard and Eurachem Laboratory Guide to Method Validation. In all the methods, the studied parameters fall within the acceptance range, so they are validated. The quality of the results in real samples is controlled through field validation.
- 9 June 2023
- Published by MDPI AG in Environments
- Vol. 10 (6) , 98
Open AccessQuality Assurance of Potential Radioanalytical Methods for 14C in Environmental Samples
Today, the measurement of 14C in environmental samples is of particular interest, as it enables the assessment of the impact caused by nuclear activities and the fossil fuel industry on the environment. In order to assure the quality of 14C measurement results, the strategy to enlarge the validation of three radioanalytical methods in environmental samples using liquid scintillation spectrometry—the direct counting of water, bubbling of water and combustion of solids—is presented. Due certain difficulties, such as the lack of quality control materials and the scarcity of proficiency test and intercomparison exercises, especially in solid samples, a set of water and soil samples were prepared for the purpose by tracing them with known quantities of a 14C standard solution at two activity levels. Aliquots were subjected to the corresponding method and their activity concentration was calculated. Finally, uncertainty, detection limit, accuracy, precision, repeatability and linearity were analysed. The acceptance criteria for the quality parameters were previously established according to ISO 13528:2015 standard and Eurachem Laboratory Guide to Method Validation. In all the methods, the studied parameters fall within the acceptance range, so they are validated. The quality of the results in real samples is controlled through field validation.
- 1 July 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (3) , 233-240
COVID-19 pandemic impact on the Spanish radiation protection professionals
The pandemic situation, originated due to the appearance of the SARS-CoV-2 virus, changed many aspects of our lives and jobs. This health crisis also affected the day-to-day work of radiation protection experts, including the wide range of areas involved in this sector. This study aimed to evaluate the impact of this pandemic on the Spanish radiation protection experts. For that purpose, a Google Forms online survey was developed with 39 questions. The survey covered different aspects related to the work developed by the Spanish professionals, taking into account three different time periods along the pandemic situation. According to this survey, the appearance of COVID-19 modified the labour conditions and modalities of many Spanish radiation protection professionals, especially at the beginning of the pandemic. Most on-site activities were related to the health sector and the nuclear industry, other sectors were more flexible, and the workload increased for half of the surveyed participants. Many operational activities suffered delays due to the pandemic, whereas the one-month wearing period of passive personal dosimeters was extended in most cases during the first Spanish alarm state (15th March 2020 up to the 21st June 2020). Finally, difficulties faced in terms of the working area have been identified and may be useful for the future.
- 1 July 2022
- Published by EDP Sciences in Radioprotection
- Vol. 57 (3) , 233-240
COVID-19 pandemic impact on the Spanish radiation protection professionals
The pandemic situation, originated due to the appearance of the SARS-CoV-2 virus, changed many aspects of our lives and jobs. This health crisis also affected the day-to-day work of radiation protection experts, including the wide range of areas involved in this sector. This study aimed to evaluate the impact of this pandemic on the Spanish radiation protection experts. For that purpose, a Google Forms online survey was developed with 39 questions. The survey covered different aspects related to the work developed by the Spanish professionals, taking into account three different time periods along the pandemic situation. According to this survey, the appearance of COVID-19 modified the labour conditions and modalities of many Spanish radiation protection professionals, especially at the beginning of the pandemic. Most on-site activities were related to the health sector and the nuclear industry, other sectors were more flexible, and the workload increased for half of the surveyed participants. Many operational activities suffered delays due to the pandemic, whereas the one-month wearing period of passive personal dosimeters was extended in most cases during the first Spanish alarm state (15th March 2020 up to the 21st June 2020). Finally, difficulties faced in terms of the working area have been identified and may be useful for the future.
- Open Access
- 29 April 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (8) , 3335-3341
Selectivity analysis of 99Tc determination by LSC in the field of nuclear decommissioning
In this work, two Tc radiochemical isolation methods—a conventional method by Triskem TEVA® resin and a rapid method by Empore™ Tc Rad Disk—are compared in the field of nuclear decommissioning and 99Tc assessment. The conventional method results more selective than the rapid one, being able to remove almost 100% of the main radiological interferers with the exception of the 90Y; however, the rapid method obtains higher chemical yields (97% vs. 80%) and slightly lower detection limits (0.025 Bq vs. 0.030 Bq) than the conventional. Both methods are similar with regards to equipment and reagent costs.
- 29 April 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (8) , 3335-3341
Open AccessSelectivity analysis of 99Tc determination by LSC in the field of nuclear decommissioning
In this work, two Tc radiochemical isolation methods—a conventional method by Triskem TEVA® resin and a rapid method by Empore™ Tc Rad Disk—are compared in the field of nuclear decommissioning and 99Tc assessment. The conventional method results more selective than the rapid one, being able to remove almost 100% of the main radiological interferers with the exception of the 90Y; however, the rapid method obtains higher chemical yields (97% vs. 80%) and slightly lower detection limits (0.025 Bq vs. 0.030 Bq) than the conventional. Both methods are similar with regards to equipment and reagent costs.
- Open Access
- 1 October 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 176, 109906
Uncertainty and detection limits of 241Pu determination by liquid scintillation counting (LSC)
- 1 October 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 176, 109906
Open AccessUncertainty and detection limits of 241Pu determination by liquid scintillation counting (LSC)
- 8 November 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 318 (3) , 1773-1784
226Ra determination in complex samples using liquid scintillation counting
- 8 November 2018
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 318 (3) , 1773-1784
226Ra determination in complex samples using liquid scintillation counting
- 1 October 2017
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 177, 48-57
Analysis of the use of the IAEA rapid method of 89 Sr and 90 Sr in milk for environmental monitoring
- 1 October 2017
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 177, 48-57
Analysis of the use of the IAEA rapid method of 89 Sr and 90 Sr in milk for environmental monitoring
- 1 January 2016
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 151, 126-135
Radiological characterisation and radon equilibrium factor in the outdoor air of a post-industrial urban area
- 1 January 2016
- Published by Elsevier in Journal of Environmental Radioactivity
- Vol. 151, 126-135
Radiological characterisation and radon equilibrium factor in the outdoor air of a post-industrial urban area