Nilesh Chothani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nilesh Chothani has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Dharmesh Patel
Government Engineering College
6 shared publications- Dharmesh Patel
Government Engineering College
5 shared publications - Maulik Raichura
Electrical Engineering Department Gujarat Technological University (GTU) Ahmedabad Gujarat India
3 shared publications Ujjaval J. Patel
Department of Electrical Engineering, Adani Institute of Infrastructure Engineering, Ahmedabad, India
3 shared publicationsDhaval N. Tailor
Department of Electrical Engineering, A. D. Patel Institute of Technology, Anand, India
2 shared publications- Hinal Shah
Indus University, India
2 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (2) , 986-998
Parameters affecting protection coordination of high voltage distribution network with distributed energy resources
Distributed energy resources (DERs) have become favorable sources of power against conventional power sources at distribution level because of their advantages like reduction in power loss and voltage drop, and environment friendliness. Integrating of DERs into high voltage distribution networks (HVDNs) introduces significant challenges to protection relay coordination because of their dynamic operational characteristics. This comprehensive study investigates key parameters influencing effective protection relay coordination in distribution networks (DNs), including fault current variability, DER penetration level, network topology, and relay settings. Through comprehensive simulation conducted on modified IEEE 4-bus HVDN with variable DER configurations through PSCAD/EMTDC 4.5 software, the research analysis evaluates the impact of these parameters on protection reliability and speed. Results indicate that high DER penetration leads to fault current increment by 10-20%, grid current contribution reduction by 10-15% as well as relay current setting alterations approximately by 30-40% which necessitates adaptive protection schemes. Network topology and relay coordination strategy significantly affect fault detection and isolation process. The finding provides understanding of parameters affecting protection coordination which helps in its optimization and having reliable and secure operation of DN.
- 1 April 2026
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 15 (2) , 986-998
Open AccessParameters affecting protection coordination of high voltage distribution network with distributed energy resources
Distributed energy resources (DERs) have become favorable sources of power against conventional power sources at distribution level because of their advantages like reduction in power loss and voltage drop, and environment friendliness. Integrating of DERs into high voltage distribution networks (HVDNs) introduces significant challenges to protection relay coordination because of their dynamic operational characteristics. This comprehensive study investigates key parameters influencing effective protection relay coordination in distribution networks (DNs), including fault current variability, DER penetration level, network topology, and relay settings. Through comprehensive simulation conducted on modified IEEE 4-bus HVDN with variable DER configurations through PSCAD/EMTDC 4.5 software, the research analysis evaluates the impact of these parameters on protection reliability and speed. Results indicate that high DER penetration leads to fault current increment by 10-20%, grid current contribution reduction by 10-15% as well as relay current setting alterations approximately by 30-40% which necessitates adaptive protection schemes. Network topology and relay coordination strategy significantly affect fault detection and isolation process. The finding provides understanding of parameters affecting protection coordination which helps in its optimization and having reliable and secure operation of DN.
- 12 January 2026
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 47 (1)
Modelling solar irradiance variability with the Beta PDF for improved power generation estimation
- 12 January 2026
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 47 (1)
Modelling solar irradiance variability with the Beta PDF for improved power generation estimation
- Open Access
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 163832-163843
Dynamic Differential Protection of Transformer Considering CT Saturation Based on Waveform Distortion Estimation
The protection relay performs a significant role in maintaining the power system’s reliability and stability. However, Current Transformer (CT) saturation affects the overcurrent, differential and distance protection under various conditions. Under the CT saturation condition, the secondary current waveform is distorted depending upon the level of saturation. This paper describes an adaptive differential protection scheme for a transformer considering the effect of magnetizing inrush and the CT saturation. In the proposed methodology, the inrush conditions and CT saturation conditions are detected using the waveform distortion estimation and current polarity index technique by utilizing the current signal parameters. The power system is simulated in PSCAD software to create various fault conditions in the transformer. Different transformer internal and external faults have been generated, considering mild to heavy CT saturation phenomenon. The proposed dynamic differential relaying method is implemented in MATLAB software for CT saturation detection and transformer fault zone identification. A hardware prototype has been developed to simulate practical inrush and fault scenarios on a transformer to validate the proposed relaying technique. The proposed algorithm is implemented in the microcontroller, which efficiently detects the occurrence of different levels of CT saturation and successfully operates for all internal faults. On the other hand, the proposed relaying scheme remains inoperative for all inrush conditions and out-of-zone transformer faults by effectively detecting CT saturation.
- 12 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 163832-163843
Open AccessDynamic Differential Protection of Transformer Considering CT Saturation Based on Waveform Distortion Estimation
The protection relay performs a significant role in maintaining the power system’s reliability and stability. However, Current Transformer (CT) saturation affects the overcurrent, differential and distance protection under various conditions. Under the CT saturation condition, the secondary current waveform is distorted depending upon the level of saturation. This paper describes an adaptive differential protection scheme for a transformer considering the effect of magnetizing inrush and the CT saturation. In the proposed methodology, the inrush conditions and CT saturation conditions are detected using the waveform distortion estimation and current polarity index technique by utilizing the current signal parameters. The power system is simulated in PSCAD software to create various fault conditions in the transformer. Different transformer internal and external faults have been generated, considering mild to heavy CT saturation phenomenon. The proposed dynamic differential relaying method is implemented in MATLAB software for CT saturation detection and transformer fault zone identification. A hardware prototype has been developed to simulate practical inrush and fault scenarios on a transformer to validate the proposed relaying technique. The proposed algorithm is implemented in the microcontroller, which efficiently detects the occurrence of different levels of CT saturation and successfully operates for all internal faults. On the other hand, the proposed relaying scheme remains inoperative for all inrush conditions and out-of-zone transformer faults by effectively detecting CT saturation.
- 10 December 2024
- Published by Springer Nature
- p. 275-285
Phasor Comparison and Differential Current-Based Earth Fault Detection for Low-Impedance Grounded Transformer in Microgrid
- 10 December 2024
- Published by Springer Nature
- p. 275-285
Phasor Comparison and Differential Current-Based Earth Fault Detection for Low-Impedance Grounded Transformer in Microgrid
- 11 August 2023
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 25 (5) , 675-691
Improving protection of compensated transmission line using IoT enabled adaptive auto reclosing scheme
Protection of critical components in the power sector especially the transmission line system is very important to minimize loss of revenue, resources, and productivity. Improvement of power transfer capacity and voltage profile in smart the power grid is achieved by Series Compensation (SC). However, it poses many serious issues in the protection of compensated transmission lines. The majority of faults occurring in transmission lines are transient in nature for which service continuity can be regained by an auto-reclosing scheme. An efficient auto-reclosing scheme that can provide adaptive protection with reliable operation is required to prevent transient and permanent faults in the series compensated transmission line (SCTL). This work highlights the emulation of an Internet of Things (IoT) aided adaptive auto-reclosing scheme in association with an ESP32 controller that provides adaptive dead time control. The reclosing instance has been identified by means of a synchro-check relay. A real-time IoT-aided auto-reclosing scheme has been realized using the ESP32 controller that can generate a trip/reclosing signal instantaneously using the concepts of edge computing. The projected system has been also corroborated by simulating the modeled smart power grid network with wide variations in fault context in PSCAD. The validation of the set of rules is done in MATLAB software for the proposed auto-reclosing scheme. The extracted test outcomes of the simulation and its laboratory hardware implementation indicate an appreciable reduction in dead time which reflects the efficacy of the developed protection scheme.
- 11 August 2023
- Published by Walter de Gruyter GmbH in International Journal of Emerging Electric Power Systems
- Vol. 25 (5) , 675-691
Improving protection of compensated transmission line using IoT enabled adaptive auto reclosing scheme
Protection of critical components in the power sector especially the transmission line system is very important to minimize loss of revenue, resources, and productivity. Improvement of power transfer capacity and voltage profile in smart the power grid is achieved by Series Compensation (SC). However, it poses many serious issues in the protection of compensated transmission lines. The majority of faults occurring in transmission lines are transient in nature for which service continuity can be regained by an auto-reclosing scheme. An efficient auto-reclosing scheme that can provide adaptive protection with reliable operation is required to prevent transient and permanent faults in the series compensated transmission line (SCTL). This work highlights the emulation of an Internet of Things (IoT) aided adaptive auto-reclosing scheme in association with an ESP32 controller that provides adaptive dead time control. The reclosing instance has been identified by means of a synchro-check relay. A real-time IoT-aided auto-reclosing scheme has been realized using the ESP32 controller that can generate a trip/reclosing signal instantaneously using the concepts of edge computing. The projected system has been also corroborated by simulating the modeled smart power grid network with wide variations in fault context in PSCAD. The validation of the set of rules is done in MATLAB software for the proposed auto-reclosing scheme. The extracted test outcomes of the simulation and its laboratory hardware implementation indicate an appreciable reduction in dead time which reflects the efficacy of the developed protection scheme.
- 17 April 2023
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (2) , 4195-4210
Protection challenges and mitigation techniques of power grid integrated to renewable energy sources: A review
Recently, there has been a noticeable contribution from renewable energy sources to enhance sources of electricity generation. The annual increase in energy consumption, the negative impacts of unsustainable energy sources, and the worldwide deterioration of fossil fuels like coal and oil are the causes of this. Solar and wind energy sources are the most often used renewable energy sources because of its minimal adverse environmental effects, negligible operating costs, and straightforward operational requirements. Simultaneously, renewable energy sources (RES) bring new challenges for protective measures. The dynamic response of RES, which is mostly controlled by inverters, is not taken into consideration while designing protection systems because rotating machines tend to behave dynamically as generating units. The magnitude and phase angle comparison, amount of negative-sequence, and short-circuit current level are all impacted by the RES, which presents difficulties for various pertinent transmission and distribution lines protection algorithms. This article is focused on ‘Smart Grid Concept’, known as the future power grid, which uses bidirectional flows of electricity and information to build an automated energy delivery network that is broadly distributed. Protection challenges and their feasible solutions for grid integrated RES are addressed in this review paper.
- 17 April 2023
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 45 (2) , 4195-4210
Protection challenges and mitigation techniques of power grid integrated to renewable energy sources: A review
Recently, there has been a noticeable contribution from renewable energy sources to enhance sources of electricity generation. The annual increase in energy consumption, the negative impacts of unsustainable energy sources, and the worldwide deterioration of fossil fuels like coal and oil are the causes of this. Solar and wind energy sources are the most often used renewable energy sources because of its minimal adverse environmental effects, negligible operating costs, and straightforward operational requirements. Simultaneously, renewable energy sources (RES) bring new challenges for protective measures. The dynamic response of RES, which is mostly controlled by inverters, is not taken into consideration while designing protection systems because rotating machines tend to behave dynamically as generating units. The magnitude and phase angle comparison, amount of negative-sequence, and short-circuit current level are all impacted by the RES, which presents difficulties for various pertinent transmission and distribution lines protection algorithms. This article is focused on ‘Smart Grid Concept’, known as the future power grid, which uses bidirectional flows of electricity and information to build an automated energy delivery network that is broadly distributed. Protection challenges and their feasible solutions for grid integrated RES are addressed in this review paper.
- 19 February 2023
- Published by Springer Nature
- p. 87-111
Investigation of New Fuzzy Cascade Controller for Frequency Deviation in Hybrid Power Systems
- 19 February 2023
- Published by Springer Nature
- p. 87-111
Investigation of New Fuzzy Cascade Controller for Frequency Deviation in Hybrid Power Systems
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2981 (1) , 070004
Analysis of factors affecting protection of distribution system with distributed generation sources
Distributed Generation (DG) sources have started becoming preferable sources of power in distribution system. DG sources gives advantages like reduction in loss
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2981 (1) , 070004
Open AccessAnalysis of factors affecting protection of distribution system with distributed generation sources
Distributed Generation (DG) sources have started becoming preferable sources of power in distribution system. DG sources gives advantages like reduction in loss
- 1 January 2023
- Published by Springer Nature
- p. 121-136
Evaluation of Various Dynamics on Current Transformer Saturation with a Model Study on Power System Protection
- 1 January 2023
- Published by Springer Nature
- p. 121-136
Evaluation of Various Dynamics on Current Transformer Saturation with a Model Study on Power System Protection
- Open Access
- 1 September 2022
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 20 (3) , 225-239
Fault Detection and Classification in Interconnected System with Wind Generation Using ANN and SVM
Protective relays are installed in generation, transmission, and distribution system for detection, classification, and estimation of faults. To match the future load demand and to get uninterrupted power supply, use of renewable energy sources are increasing day by day. Faults can occur in transmission lines, transformers, generators, and busbars but the nature of these faults may change many times when renewable energy sources are considered. This research paper introduce techniques to detect and classify different faults on transmission line in the presence of wind energy sources using efficient tools of artificial intelligence. The main challenges of the system fault detection, in presence of wind turbine lie in their non-linearity, uncertainty and unknown disturbances. PSCAD/EMTDC software tool is used to simulate the power system model with RES which is implemented in MATLAB and Python software. Artificial Neural Network (ANN) and Support Vector Machine (SVM) algorithms have been used to classify and detect faults on transmission lines connected with wind energy source. The proposed technique has been validated for internal faults on transmission line and external faults on power system. In total of 4320 internal and external fault cases with wide variation in system parameters have been used for validation of the proposed model. The proposed model gives an overall fault zone identification accuracy of more than 99 % in presence of wind energy source. The results obtained from validation show that the performance of SVM classifier is better than ANN in term of efficacy and classification time.
- 1 September 2022
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 20 (3) , 225-239
Open AccessFault Detection and Classification in Interconnected System with Wind Generation Using ANN and SVM
Protective relays are installed in generation, transmission, and distribution system for detection, classification, and estimation of faults. To match the future load demand and to get uninterrupted power supply, use of renewable energy sources are increasing day by day. Faults can occur in transmission lines, transformers, generators, and busbars but the nature of these faults may change many times when renewable energy sources are considered. This research paper introduce techniques to detect and classify different faults on transmission line in the presence of wind energy sources using efficient tools of artificial intelligence. The main challenges of the system fault detection, in presence of wind turbine lie in their non-linearity, uncertainty and unknown disturbances. PSCAD/EMTDC software tool is used to simulate the power system model with RES which is implemented in MATLAB and Python software. Artificial Neural Network (ANN) and Support Vector Machine (SVM) algorithms have been used to classify and detect faults on transmission lines connected with wind energy source. The proposed technique has been validated for internal faults on transmission line and external faults on power system. In total of 4320 internal and external fault cases with wide variation in system parameters have been used for validation of the proposed model. The proposed model gives an overall fault zone identification accuracy of more than 99 % in presence of wind energy source. The results obtained from validation show that the performance of SVM classifier is better than ANN in term of efficacy and classification time.