Gert Meijer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gert Meijer has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Ewald Maria Bronkhorst
Department of Dentistry, Radboud Institute for Health Sciences, Radboud University Medical Center, 6500 HB Nijmegen, The Netherlands
6 shared publications - Luc Van Doorne
Department of Oral and Craniomaxillofacial Surgery, Faculty of Medicine and Health Sciences, Ghent University Hospital, Corneel Heymanslaan 10, 9000 Ghent, Belgium
4 shared publications - Thomas Jan Jaap Maal
Radboudumc 3D Lab, Radboud University Medical Center, Philips van Leydenlaan 25, 6525 EX Nijmegen, The Netherlands
4 shared publications Frans Delfos
Dental Laboratory of the Department of Dentistry Radboud University Medical Center Nijmegen The Netherlands
3 shared publications- Hugo De Bruyn
Department of Periodontology and Oral Implantology, Oral Health Sciences, Faculty of Medicine and Health Sciences, Ghent University, Corneel Heymanslaan 10, 9000 Ghent, Belgium
3 shared publications - Edith Groenendijk
Private Clinic for Oral Implantology & Reconstructive Dentistry, Implantologie Den Haag BV, Stadhouderslaan 12, 2517 HW The Hague, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 13 November 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Budget Impact Analysis: Digital Workflow Significantly Reduces Costs of Implant Supported Overdentures (IODs)
Background: For edentulism, an implant supported removable complete overdenture (IOD) is an attractive solution to restore patients' chewing capacity, aesthetics, and self‐esteem, however, treatment is expensive and time consuming.Purpose/Aim: To estimate the decline in costs for digitally designed and CAD/CAM fabricated IODs (3D‐IODs) compared to conventionally fabricated IODs (C‐IODs) at comparable general health related quality of life (GHRQoL).Materials and Method: A randomized crossover study enrolled 36 fully edentulous patients, in whom six maxillary implants were placed together with two mandibular implants, if not already present.At the start of the study, a set of C‐IODs and 3D‐IODs was fabricated for each patient. All patients wore each IOD‐type for 1 year: first the 3D‐IOD and the second year a C‐IOD, or vice versa. At all three‐time points patients general QoL was assessed using the EQ‐5D‐5L questionnaire as well as the SF‐36 from which the SF‐6D was obtained, to research the anticipation of no significant difference.To enable cost consequence analysis (CCA), both costs made within healthcare and patient costs were assessed. Subsequently, a budget impact analysis (BIA) was performed to demonstrate the potential savings.Results: No differences in general GHRQoL were seen between C‐IOD (M = 0.840, SD = 0.177) and 3D‐IOD (M = 0.837, SD = 0.156) (paired t‐test (N = 31): p = 0.880).With respect to the total costs for a complete IOD, however, the digital approach showed a reduction in initial total costs of 14.2% (€4700.33 vs. €4030.61: p < 0,001), in treatment time of 41.1% (309 vs. 182 min: p < 0.001), and in number of treatment sessions of 47.1% (5.68 vs. 3.0: p < 0.001). For repairs for an IOD in both the upper and lower jaw, the C‐IOD and 3D‐IOD scored similar for treatment time as well as additional costs.Conclusion: Implementing a 3D workflow in the production of IOD's supplies patients with a high‐quality 3D‐IOD at lower costs.Trial Registration: NL‐OMON44248 https://onderzoekmetmensen.nl/en/trial/44248
- 13 November 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Open AccessBudget Impact Analysis: Digital Workflow Significantly Reduces Costs of Implant Supported Overdentures (IODs)
Background: For edentulism, an implant supported removable complete overdenture (IOD) is an attractive solution to restore patients' chewing capacity, aesthetics, and self‐esteem, however, treatment is expensive and time consuming.Purpose/Aim: To estimate the decline in costs for digitally designed and CAD/CAM fabricated IODs (3D‐IODs) compared to conventionally fabricated IODs (C‐IODs) at comparable general health related quality of life (GHRQoL).Materials and Method: A randomized crossover study enrolled 36 fully edentulous patients, in whom six maxillary implants were placed together with two mandibular implants, if not already present.At the start of the study, a set of C‐IODs and 3D‐IODs was fabricated for each patient. All patients wore each IOD‐type for 1 year: first the 3D‐IOD and the second year a C‐IOD, or vice versa. At all three‐time points patients general QoL was assessed using the EQ‐5D‐5L questionnaire as well as the SF‐36 from which the SF‐6D was obtained, to research the anticipation of no significant difference.To enable cost consequence analysis (CCA), both costs made within healthcare and patient costs were assessed. Subsequently, a budget impact analysis (BIA) was performed to demonstrate the potential savings.Results: No differences in general GHRQoL were seen between C‐IOD (M = 0.840, SD = 0.177) and 3D‐IOD (M = 0.837, SD = 0.156) (paired t‐test (N = 31): p = 0.880).With respect to the total costs for a complete IOD, however, the digital approach showed a reduction in initial total costs of 14.2% (€4700.33 vs. €4030.61: p < 0,001), in treatment time of 41.1% (309 vs. 182 min: p < 0.001), and in number of treatment sessions of 47.1% (5.68 vs. 3.0: p < 0.001). For repairs for an IOD in both the upper and lower jaw, the C‐IOD and 3D‐IOD scored similar for treatment time as well as additional costs.Conclusion: Implementing a 3D workflow in the production of IOD's supplies patients with a high‐quality 3D‐IOD at lower costs.Trial Registration: NL‐OMON44248 https://onderzoekmetmensen.nl/en/trial/44248
- Open Access
- 30 September 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Fully digital versus conventional workflow: Are removable complete overdentures equally good? A randomized crossover trial
Introduction: Implant‐supported removable complete overdentures (IODs) are a common treatment in case of edentulism and malfunctioning of the conventional denture. Manufacturing IODs in a conventional way (C‐IODs) is time‐consuming, but in a digital workflow, this can be done in three sessions. Digitally produced IODs (3D‐IODs) are also more advantageous than C‐IODs because lost or broken 3D‐IODs can be swiftly reproduced as the digital design is always available.Purpose: To prove in a non‐inferiority study, with a margin of 0.3 point per Oral Health Impact Profile‐20 (OHIP‐20) question, that IODs made according to a fully digital workflow (3D‐IODs), function as good as C‐IODs with respect to patient‐reported outcome measures (PROMs).Materials and Methods: This randomized crossover study included 36 fully edentulous patients who showed extreme resorption of the maxillary alveolar process, making denture retention difficult. After a maxillary bone augmentation and the installation of 4–6 implants, each patient wore both types of IOD for 1 year each, with the order reversed in two subsets of patients. The 3D‐IODs and C‐IODs were fabricated in advance for both jaws (at least two mandibular implants were already present).The OHIP‐20 survey was performed at baseline, after 1 year (before the IOD switch), and after 2 years to determine patient satisfaction scores using a visual analog scale (VAS). The general health status was assessed using the Short Form (SF‐36) questionnaire.Results: Regarding the PROMs, patients preferred the 3D‐IOD: the improvement on the overall OHIP scale (0–4), expressed as a mean, was 0.26 points greater than for the C‐IOD (p < 0.001). This applied also to the VAS scale (1–100) with an increase of 7.37 points (p < 0.001). Regarding the SF‐36 scale, only for the item “emotional well‐being,” the 3D‐IOD scored significantly better (p = 0.033).Conclusion: Compared with conventionally fabricated C‐IODs, fully digitally produced 3D‐IODs resulted in significantly higher OHIP‐20 and satisfaction scores.
- 30 September 2024
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Open AccessFully digital versus conventional workflow: Are removable complete overdentures equally good? A randomized crossover trial
Introduction: Implant‐supported removable complete overdentures (IODs) are a common treatment in case of edentulism and malfunctioning of the conventional denture. Manufacturing IODs in a conventional way (C‐IODs) is time‐consuming, but in a digital workflow, this can be done in three sessions. Digitally produced IODs (3D‐IODs) are also more advantageous than C‐IODs because lost or broken 3D‐IODs can be swiftly reproduced as the digital design is always available.Purpose: To prove in a non‐inferiority study, with a margin of 0.3 point per Oral Health Impact Profile‐20 (OHIP‐20) question, that IODs made according to a fully digital workflow (3D‐IODs), function as good as C‐IODs with respect to patient‐reported outcome measures (PROMs).Materials and Methods: This randomized crossover study included 36 fully edentulous patients who showed extreme resorption of the maxillary alveolar process, making denture retention difficult. After a maxillary bone augmentation and the installation of 4–6 implants, each patient wore both types of IOD for 1 year each, with the order reversed in two subsets of patients. The 3D‐IODs and C‐IODs were fabricated in advance for both jaws (at least two mandibular implants were already present).The OHIP‐20 survey was performed at baseline, after 1 year (before the IOD switch), and after 2 years to determine patient satisfaction scores using a visual analog scale (VAS). The general health status was assessed using the Short Form (SF‐36) questionnaire.Results: Regarding the PROMs, patients preferred the 3D‐IOD: the improvement on the overall OHIP scale (0–4), expressed as a mean, was 0.26 points greater than for the C‐IOD (p < 0.001). This applied also to the VAS scale (1–100) with an increase of 7.37 points (p < 0.001). Regarding the SF‐36 scale, only for the item “emotional well‐being,” the 3D‐IOD scored significantly better (p = 0.033).Conclusion: Compared with conventionally fabricated C‐IODs, fully digitally produced 3D‐IODs resulted in significantly higher OHIP‐20 and satisfaction scores.
- Open Access
- 8 December 2023
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 165 (3) , 262-271.e3
The effect of surface roughening on the success of orthodontic mini-implants: A systematic review and meta-analysis
- 8 December 2023
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 165 (3) , 262-271.e3
Open AccessThe effect of surface roughening on the success of orthodontic mini-implants: A systematic review and meta-analysis
- 13 June 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (5) , 829-839
Five years clinical outcome of maxillary mini dental implant overdenture treatment: A prospective multicenter clinical cohort study
Background: The long‐term clinical outcome of mini dental implants (MDIs) to support an overdenture is underreported especially in severely atrophic maxillae and when installed flaplessly.Purpose: The current report is a 5‐years follow‐up of the previously published 2‐ and 3‐years clinical outcome of MDIs supporting a maxillary overdenture in narrow alveolar ridges. MDI survival, marginal bone level, peri‐implant health, technical complications, and oral health related quality of life (OHIP) and respective changes over time are reported.Materials and methods: Subjects aged 50 years or older, in need of improvement of maxillary denture retention, were included. The MDIs were 2.4 mm diameter one‐piece tapered implants, Class 4 pure Titanium, and lengths 10 or 11.5 mm. Under local anesthesia, 5–6 MDIs were placed in atrophic maxillae with a free‐handed flapless approach. One week postoperative the denture was adapted with a retentive soft reliner. The final prosthetic connection was established after 6 months with a metal‐reinforced horse‐shoe denture. Clinical outcome after 5 years was assessed with probing pocket depts (PPD), bleeding on probing (BoP), and additional cone beam computed tomography (CBCT) MDI bone level measurements were performed. Oral Health‐Related Quality of Life (OHRQoL) investigated with OHIP‐14 was assessed preoperative, during provisional loading, and after final prosthetic connection up to 5 years.Results: Initially, 31 patients (14 females and 17 males) with mean age 62.30 underwent treatment. In the provisional loading interval, 16 patients encountered 32/185 MDIs failures, resulting in a failure of 17.3%; 170 MDIs were functionally loaded in 29 patients. Additionally, 14 implants were lost in three patients, all of whom had had already previous failures.Reimplantation of 17 MDIs were performed during the provisional loading and 2 MDI after functional loading. After 5 years, the absolute implant failure rate was 46/204 (22.5%), corresponding to a cumulative failure rate of 23.2%. Prosthetic failure was observed in four patients due to implant loss and in two patients related to excessive one‐piece implant ball attachment wear, making the 5‐years prosthetic success 80.0%.The mean PPD and absence/presence of BoP for 149 implants at 5 years was 4.3 and 0.2 mm, respectively. Average mesial‐distal‐vestibular‐palatal bone loss in the interval 2–5 years was 0.08 mm. No statistically significant difference in marginal MDI bone loss between male or female (p = 0.835), smoking and nonsmoking (p = 0.666) was observed. The five‐years total measured CBCT interdental bone level (mesial and distal) correlates with the 5‐years PPD (Pearson 0.434; p = 0.01). After 5 years, OHRQoL with the treatment procedure was assessed in 27/31 participants. Decreasing mean total OHIP‐14 scores with improved OHRQoL, was observed in 27/31 participants, with values of 21.3 at baseline to 15.6 at the time of provisional loading which significantly (p = 0.006) decrease to 7.3 at the final prosthetic connection. The next 3–5 years further decrease was observed with 6.5 and 4.96, respectively.Conclusions: Maxillary MDIs for overdentures are an accessible and acceptable treatment option. Although after 5 years between one fifth and one fourth of the MDIs were lost, prosthetic success remains 80.0% and high OHRQoL could be achieved.
- 13 June 2023
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 25 (5) , 829-839
Five years clinical outcome of maxillary mini dental implant overdenture treatment: A prospective multicenter clinical cohort study
Background: The long‐term clinical outcome of mini dental implants (MDIs) to support an overdenture is underreported especially in severely atrophic maxillae and when installed flaplessly.Purpose: The current report is a 5‐years follow‐up of the previously published 2‐ and 3‐years clinical outcome of MDIs supporting a maxillary overdenture in narrow alveolar ridges. MDI survival, marginal bone level, peri‐implant health, technical complications, and oral health related quality of life (OHIP) and respective changes over time are reported.Materials and methods: Subjects aged 50 years or older, in need of improvement of maxillary denture retention, were included. The MDIs were 2.4 mm diameter one‐piece tapered implants, Class 4 pure Titanium, and lengths 10 or 11.5 mm. Under local anesthesia, 5–6 MDIs were placed in atrophic maxillae with a free‐handed flapless approach. One week postoperative the denture was adapted with a retentive soft reliner. The final prosthetic connection was established after 6 months with a metal‐reinforced horse‐shoe denture. Clinical outcome after 5 years was assessed with probing pocket depts (PPD), bleeding on probing (BoP), and additional cone beam computed tomography (CBCT) MDI bone level measurements were performed. Oral Health‐Related Quality of Life (OHRQoL) investigated with OHIP‐14 was assessed preoperative, during provisional loading, and after final prosthetic connection up to 5 years.Results: Initially, 31 patients (14 females and 17 males) with mean age 62.30 underwent treatment. In the provisional loading interval, 16 patients encountered 32/185 MDIs failures, resulting in a failure of 17.3%; 170 MDIs were functionally loaded in 29 patients. Additionally, 14 implants were lost in three patients, all of whom had had already previous failures.Reimplantation of 17 MDIs were performed during the provisional loading and 2 MDI after functional loading. After 5 years, the absolute implant failure rate was 46/204 (22.5%), corresponding to a cumulative failure rate of 23.2%. Prosthetic failure was observed in four patients due to implant loss and in two patients related to excessive one‐piece implant ball attachment wear, making the 5‐years prosthetic success 80.0%.The mean PPD and absence/presence of BoP for 149 implants at 5 years was 4.3 and 0.2 mm, respectively. Average mesial‐distal‐vestibular‐palatal bone loss in the interval 2–5 years was 0.08 mm. No statistically significant difference in marginal MDI bone loss between male or female (p = 0.835), smoking and nonsmoking (p = 0.666) was observed. The five‐years total measured CBCT interdental bone level (mesial and distal) correlates with the 5‐years PPD (Pearson 0.434; p = 0.01). After 5 years, OHRQoL with the treatment procedure was assessed in 27/31 participants. Decreasing mean total OHIP‐14 scores with improved OHRQoL, was observed in 27/31 participants, with values of 21.3 at baseline to 15.6 at the time of provisional loading which significantly (p = 0.006) decrease to 7.3 at the final prosthetic connection. The next 3–5 years further decrease was observed with 6.5 and 4.96, respectively.Conclusions: Maxillary MDIs for overdentures are an accessible and acceptable treatment option. Although after 5 years between one fifth and one fourth of the MDIs were lost, prosthetic success remains 80.0% and high OHRQoL could be achieved.
- Open Access
- 31 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (7) , 2625
Factors Associated with Esthetic Outcomes of Flapless Immediate Placed and Loaded Implants in the Maxillary Incisor Region—Three-Year Results of a Prospective Case Series
Flapless immediate implant placement and provisionalization (FIIPP) is often associated with an increased risk of buccal soft-tissue recession. This study aims to assess the 3-year esthetic outcome. In 100 consecutive patients, one maxillary incisor, with or without a pre-extraction buccal bone defect (≤5 mm), was replaced by an implant installed in a maximal palatal position (buccal gap ≥2 mm). The created gaps were filled with bovine bone substitute. Patient satisfaction (PS), pink esthetic scores (PES/modPES), and white esthetic score (WES) were calculated at different time points. A multilevel regression analysis (MRA) was performed to analyze which factors may be associated with the esthetics. After three years, PS scored 8.9 ± 0.84 on a scale of 10 (n = 83), and the soft-tissue esthetics were high (PES = 12.2; modPES = 8.5), as was the WES (8.2), showing no decrease from one year. Buccal bone defect size and smoking could not be associated with the soft-tissue outcome; however, implant location, gap size, and emergence profiles could. Performing FIIPP, the final crown (WES) scored highest when it was cemented, the soft tissue (PES/modPES) in central-incisor positions, and all (WES/PES/modPES) with concave emergence profiles.
- 31 March 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (7) , 2625
Open AccessFactors Associated with Esthetic Outcomes of Flapless Immediate Placed and Loaded Implants in the Maxillary Incisor Region—Three-Year Results of a Prospective Case Series
Flapless immediate implant placement and provisionalization (FIIPP) is often associated with an increased risk of buccal soft-tissue recession. This study aims to assess the 3-year esthetic outcome. In 100 consecutive patients, one maxillary incisor, with or without a pre-extraction buccal bone defect (≤5 mm), was replaced by an implant installed in a maximal palatal position (buccal gap ≥2 mm). The created gaps were filled with bovine bone substitute. Patient satisfaction (PS), pink esthetic scores (PES/modPES), and white esthetic score (WES) were calculated at different time points. A multilevel regression analysis (MRA) was performed to analyze which factors may be associated with the esthetics. After three years, PS scored 8.9 ± 0.84 on a scale of 10 (n = 83), and the soft-tissue esthetics were high (PES = 12.2; modPES = 8.5), as was the WES (8.2), showing no decrease from one year. Buccal bone defect size and smoking could not be associated with the soft-tissue outcome; however, implant location, gap size, and emergence profiles could. Performing FIIPP, the final crown (WES) scored highest when it was cemented, the soft tissue (PES/modPES) in central-incisor positions, and all (WES/PES/modPES) with concave emergence profiles.
- Open Access
- 1 January 2023
- Published by XMLink in Imaging Science in Dentistry
- Vol. 53 (1) , 21-26
Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan
Deferm JT, et al. Imaging Sci Dent. 2023 Feb;53:e4. https://doi.org/10.5624/isd.20220131
- 1 January 2023
- Published by XMLink in Imaging Science in Dentistry
- Vol. 53 (1) , 21-26
Open AccessIntraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan
Deferm JT, et al. Imaging Sci Dent. 2023 Feb;53:e4. https://doi.org/10.5624/isd.20220131
- Open Access
- 5 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5876
Intraoral Scanning as an Alternative to Evaluate the Accuracy of Dental Implant Placements in Partially Edentate Situations: A Prospective Clinical Case Series
(1) Background: For years, Cone-Beam Computed Tomography’s (CBCT) have been the golden standard to evaluate implant placement accuracy. By validating Intraoral Scans (IOS) as an alternative to determine implant placement accuracy, a second CBCT could be avoided. (2) Methods: Using dynamic guided implant surgery, 23 implants were placed in 16 partially edentate patients. Preoperatively, both CBCT and IOS (Trios® 3) were obtained and subsequently imported into DTX Studio™ planning software to determine the ideal implant location. A CBCT scan and an IOS including scan abutments were acquired immediately after placement. Both postoperative CBCT and postoperative IOS were used to compare the achieved implant position with the planned implant position and were projected and analyzed using the Implant Position Orthogonal Projection (IPOP) method. (3) Results: Mean differences between the CBCT and IOS methods on the mesio–distal plane were 0.09 mm (p = 0.419) at the tip, 0.01 mm (p = 0.910) at the shoulder, −0.55° (p = 0.273) in angulation, and 0.2 mm (p = 0.280) in implant depth. Mean differences between both methods on the bucco-lingual/bucco-palatal plane were 0.25 mm (p = 0.000) at the tip, 0.12 mm (p = 0.011) at the shoulder, −0.81° (p = 0.002) in angulation, and 0.17 mm (p = 0.372) in implant depth. A statistical analysis was performed using a paired t-test. All mesiodistal deviations between the two methods showed no significant differences (p > 0.05). Buccolingual/buccopalatal deviations showed no significant difference in implant depth deviation. However, significant differences were found at the tip, shoulder, and angulation (p < 0.05). These values are of minimal clinical significance. (4) Conclusions: This study supports the hypothesis that a postoperative IOS is a valid alternative for determining implant placement accuracy.
- 5 October 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (19) , 5876
Open AccessIntraoral Scanning as an Alternative to Evaluate the Accuracy of Dental Implant Placements in Partially Edentate Situations: A Prospective Clinical Case Series
(1) Background: For years, Cone-Beam Computed Tomography’s (CBCT) have been the golden standard to evaluate implant placement accuracy. By validating Intraoral Scans (IOS) as an alternative to determine implant placement accuracy, a second CBCT could be avoided. (2) Methods: Using dynamic guided implant surgery, 23 implants were placed in 16 partially edentate patients. Preoperatively, both CBCT and IOS (Trios® 3) were obtained and subsequently imported into DTX Studio™ planning software to determine the ideal implant location. A CBCT scan and an IOS including scan abutments were acquired immediately after placement. Both postoperative CBCT and postoperative IOS were used to compare the achieved implant position with the planned implant position and were projected and analyzed using the Implant Position Orthogonal Projection (IPOP) method. (3) Results: Mean differences between the CBCT and IOS methods on the mesio–distal plane were 0.09 mm (p = 0.419) at the tip, 0.01 mm (p = 0.910) at the shoulder, −0.55° (p = 0.273) in angulation, and 0.2 mm (p = 0.280) in implant depth. Mean differences between both methods on the bucco-lingual/bucco-palatal plane were 0.25 mm (p = 0.000) at the tip, 0.12 mm (p = 0.011) at the shoulder, −0.81° (p = 0.002) in angulation, and 0.17 mm (p = 0.372) in implant depth. A statistical analysis was performed using a paired t-test. All mesiodistal deviations between the two methods showed no significant differences (p > 0.05). Buccolingual/buccopalatal deviations showed no significant difference in implant depth deviation. However, significant differences were found at the tip, shoulder, and angulation (p < 0.05). These values are of minimal clinical significance. (4) Conclusions: This study supports the hypothesis that a postoperative IOS is a valid alternative for determining implant placement accuracy.
- Open Access
- 8 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4637
Effect of Sinus Perforation with Flaplessly Placed Mini Dental Implants for Oral Rehabilitation: A 5-Year Clinical and Radiological Follow-Up
Background: Flaplessly placed one-piece mini dental implants (MDI) are an option to support maxillary overdentures. Evenly distribution of the implants over the atrophic alveolar process implies a risk of accidental sinus perforation in the posterior area which could induce sinus-related pathology. Methods: Thirty-one patients received 5–6 maxillary MDIs. Schneiderian membrane swelling was assessed with CBCT at the deepest point of the sinus in the mid-sagittal plane prior to surgery (baseline), after 2 and 5 years. Additionally, subjective patient-reported rhinosinusitis complaints, the effect of smoking, and gender differences were investigated. Results: Mean thickness of the Schneiderian membrane was 2.87 mm at baseline, 3.15 mm at 2 years, and 4.30 mm at 5 years in 27 of 31 initially treated patients. MDI perforation was detected in 21/54 sinuses. At 2 years, perforation length does not affect membrane thickness whereas baseline swelling does. In smokers, each perforated mm induced 0.87 mm additional swelling. After 5 years, the effect of baseline swelling becomes smaller whereas perforation length became statistically significant, with 0.53 mm increase for every perforated mm. The effect of smoking lost its significance. No relations between gender, membrane thickness changes, or subjective clinical sinus complaints and MDI perforation were found. Conclusion: Accidental MDI sinus perforation induces Schneiderian membrane swelling but does not interfere with clinical sinusal outcome after 5 years.
- 8 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4637
Open AccessEffect of Sinus Perforation with Flaplessly Placed Mini Dental Implants for Oral Rehabilitation: A 5-Year Clinical and Radiological Follow-Up
Background: Flaplessly placed one-piece mini dental implants (MDI) are an option to support maxillary overdentures. Evenly distribution of the implants over the atrophic alveolar process implies a risk of accidental sinus perforation in the posterior area which could induce sinus-related pathology. Methods: Thirty-one patients received 5–6 maxillary MDIs. Schneiderian membrane swelling was assessed with CBCT at the deepest point of the sinus in the mid-sagittal plane prior to surgery (baseline), after 2 and 5 years. Additionally, subjective patient-reported rhinosinusitis complaints, the effect of smoking, and gender differences were investigated. Results: Mean thickness of the Schneiderian membrane was 2.87 mm at baseline, 3.15 mm at 2 years, and 4.30 mm at 5 years in 27 of 31 initially treated patients. MDI perforation was detected in 21/54 sinuses. At 2 years, perforation length does not affect membrane thickness whereas baseline swelling does. In smokers, each perforated mm induced 0.87 mm additional swelling. After 5 years, the effect of baseline swelling becomes smaller whereas perforation length became statistically significant, with 0.53 mm increase for every perforated mm. The effect of smoking lost its significance. No relations between gender, membrane thickness changes, or subjective clinical sinus complaints and MDI perforation were found. Conclusion: Accidental MDI sinus perforation induces Schneiderian membrane swelling but does not interfere with clinical sinusal outcome after 5 years.
- Open Access
- 3 January 2022
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 24 (1) , 24-33
Does initial buccal crest thickness affect final buccal crest thickness after flapless immediate implant placement and provisionalization: A prospective cone beam computed tomogram cohort study
Background: Flapless immediate implant placement and provisionalization (FIIPP) in the aesthetic zone is still controversial. Especially, an initial buccal crest thickness (BCT) of ≤1 mm is thought to be disruptive for the final buccal crest stability jeopardizing the aesthetic outcome.Purpose: To radiographically assess the BCT and buccal crest height (BCH) after 1 year and to calculate the correlation between initial and final achieved BCT.Materials and Methods: The study was designed as a prospective study on FIIPP. Only patients were included in whom one maxillary incisor was considered as lost. In six centers, 100 consecutive patients received FIIPP. Implants were placed in a maximal palatal position of the socket, thereby creating a buccal space of at least 2 mm, which was subsequently filled with a bovine bone substitute. Files of preoperative (T0), peroperative (T1) and 1‐year postoperative (T3) cone beam computed tomogram (CBCT) scans were imported into the Maxillim™ software to analyze the changes in BCT‐BCH over time.Results: Preoperatively, 85% of the cases showed a BCT ≤1 mm, in 25% of the patients also a small buccal defect (≤5 mm) was present. Mean BCT at the level of the implant‐shoulder increased from 0.6 mm at baseline to 3.3 mm immediate postoperatively and compacted to 2.4 mm after 1 year. Mean BCH improved from 0.7 to 3.1 mm peroperatively, and resorbed to 1.7 mm after 1 year. The Pearson correlation of 0.38 between initial and final BCT was significant (p = 0.01) and therefore is valued as moderate. If only patients (75%) with an intact alveolus were included in the analysis, still a “moderate correlation” of 0.32 (p = 0.01) was calculated.Conclusions: A “moderate correlation” was shown for the hypothesis that “thinner preoperative BCT's deliver thinner BCT's” 1 year after performing FIIPP.
- 3 January 2022
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 24 (1) , 24-33
Open AccessDoes initial buccal crest thickness affect final buccal crest thickness after flapless immediate implant placement and provisionalization: A prospective cone beam computed tomogram cohort study
Background: Flapless immediate implant placement and provisionalization (FIIPP) in the aesthetic zone is still controversial. Especially, an initial buccal crest thickness (BCT) of ≤1 mm is thought to be disruptive for the final buccal crest stability jeopardizing the aesthetic outcome.Purpose: To radiographically assess the BCT and buccal crest height (BCH) after 1 year and to calculate the correlation between initial and final achieved BCT.Materials and Methods: The study was designed as a prospective study on FIIPP. Only patients were included in whom one maxillary incisor was considered as lost. In six centers, 100 consecutive patients received FIIPP. Implants were placed in a maximal palatal position of the socket, thereby creating a buccal space of at least 2 mm, which was subsequently filled with a bovine bone substitute. Files of preoperative (T0), peroperative (T1) and 1‐year postoperative (T3) cone beam computed tomogram (CBCT) scans were imported into the Maxillim™ software to analyze the changes in BCT‐BCH over time.Results: Preoperatively, 85% of the cases showed a BCT ≤1 mm, in 25% of the patients also a small buccal defect (≤5 mm) was present. Mean BCT at the level of the implant‐shoulder increased from 0.6 mm at baseline to 3.3 mm immediate postoperatively and compacted to 2.4 mm after 1 year. Mean BCH improved from 0.7 to 3.1 mm peroperatively, and resorbed to 1.7 mm after 1 year. The Pearson correlation of 0.38 between initial and final BCT was significant (p = 0.01) and therefore is valued as moderate. If only patients (75%) with an intact alveolus were included in the analysis, still a “moderate correlation” of 0.32 (p = 0.01) was calculated.Conclusions: A “moderate correlation” was shown for the hypothesis that “thinner preoperative BCT's deliver thinner BCT's” 1 year after performing FIIPP.
- 1 January 2022
- Vol. 15 (3) , 277-286
Fully digital workflow for producing implant-supported overdentures milled from PMMA on titanium bars using PEEK as the female part/sliding mechanism in three clinical visits: A case report
Purpose: To prove that a fully digital workflow, even for registration of the maxillomandibular relationship, can be employed to produce implant-supported overdentures and demonstrate that CAD/CAM techniques can be used to mill permanent implant-supported overdentures from polymethylmethacrylate discs, using polyetheretherketone as the sliding mechanism. Materials and methods: An edentulous 64-year-old woman received six implants in the maxilla after a bone augmentation procedure and two implants in the mandible. Five months after im-plant placement, intraoral scans were taken of her original complete dentures, of each prosthesis individually, and of both in centric relation, and another was taken of both edentulous arches, including the scan bodies. Along with facial photographs, sufficient digital data were gathered to design and mill titanium bars, polyetheretherketone female parts and a trial implant-supported overdenture. The tooth positions and colour were discussed with the patient using Smile Design software (3Shape, Copenhagen, Denmark). In the second session, the bars and trial implant -supported overdenture were inserted and checked, and in the third session, the final implant -supported overdentures were inserted. Results: The milled titanium bar exhibited a passive fit, as did the implant-supported overdentures. After 1 year, no prosthetic complications were noted; the measured pockets were all less than 4 mm in depth. On a visual analogue scale from 0 to 10, with 0 being the worst and 10 being the best, the patient awarded a score of 9 for her satisfaction with the implant-supported overdentures. Conclusion: A fully digital workflow enables the production of robust wear-resistant implant -supported overdentures milled from polymethylmethacrylate, using polyetheretherketone female parts as the sliding mechanism, in just three clinical sessions.
- 1 January 2022
- Vol. 15 (3) , 277-286
Fully digital workflow for producing implant-supported overdentures milled from PMMA on titanium bars using PEEK as the female part/sliding mechanism in three clinical visits: A case report
Purpose: To prove that a fully digital workflow, even for registration of the maxillomandibular relationship, can be employed to produce implant-supported overdentures and demonstrate that CAD/CAM techniques can be used to mill permanent implant-supported overdentures from polymethylmethacrylate discs, using polyetheretherketone as the sliding mechanism. Materials and methods: An edentulous 64-year-old woman received six implants in the maxilla after a bone augmentation procedure and two implants in the mandible. Five months after im-plant placement, intraoral scans were taken of her original complete dentures, of each prosthesis individually, and of both in centric relation, and another was taken of both edentulous arches, including the scan bodies. Along with facial photographs, sufficient digital data were gathered to design and mill titanium bars, polyetheretherketone female parts and a trial implant-supported overdenture. The tooth positions and colour were discussed with the patient using Smile Design software (3Shape, Copenhagen, Denmark). In the second session, the bars and trial implant -supported overdenture were inserted and checked, and in the third session, the final implant -supported overdentures were inserted. Results: The milled titanium bar exhibited a passive fit, as did the implant-supported overdentures. After 1 year, no prosthetic complications were noted; the measured pockets were all less than 4 mm in depth. On a visual analogue scale from 0 to 10, with 0 being the worst and 10 being the best, the patient awarded a score of 9 for her satisfaction with the implant-supported overdentures. Conclusion: A fully digital workflow enables the production of robust wear-resistant implant -supported overdentures milled from polymethylmethacrylate, using polyetheretherketone female parts as the sliding mechanism, in just three clinical sessions.