Ankur Geete
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ankur Geete has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
A. I. Khandwawala
Department of Mechanical Engineering, SGSITS, Indore, Madhya Pradesh, India
1 shared publicationA. Singh
Sushila Devi Bansal College of Technology, Indore, India
1 shared publicationAbhishek Patwa
Mechanical Engineering Department, Sushila Devi Bansal College of Technology, Indore, India
1 shared publicationAditya Singh
Sushila Devi Bansal College of Technology
1 shared publicationAjay Bhargava
Mechanical Engineering Department, Acropolis Technical Campus , Indore, Madhya Pradesh, India
1 shared publicationAjinkya Mahajan
Department of Mechanical Engineering Sushila Devi Bansal College of Technology Indore Madhya Pradesh India
1 shared publication
Latest Publications
- 9 May 2023
- Published by Springer Nature in International Journal of Energy and Water Resources
- Vol. 9 (2) , 379-402
Entropy–exergy analyses on fabricated frugal solar distillation plant using phase change material and preheating phenomenon
- 9 May 2023
- Published by Springer Nature in International Journal of Energy and Water Resources
- Vol. 9 (2) , 379-402
Entropy–exergy analyses on fabricated frugal solar distillation plant using phase change material and preheating phenomenon
- 25 November 2021
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 6041-6051
Exergy analyses on fabricated cylindrical solar collectors with and without internal fins at various conditions
Effects of internal fins in absorber pipes are analysed experimentally on fabricated cylindrical collector with different lengths of fins at various flow rates on different days. Comparative analyses are done at different time intervals on same day at two cylindrical collectors. Axis of absorber pipe is orientated in North-South direction which is Mode-III type. Ambient/inlet/output temperatures, flow rates and useful heat gain rates are found with/without fins. Inlet/outlet rates of exergy, exergy gain rates and exergy efficiencies are found at different conditions. Experimental work is concluded; maximum outlet exergy and exergy gain rate i.e. 743.681W and 136.643W are found with fins considering Sun’s cone angle. Maximum temperature increment in fluid, percentage increment in exergy from inlet to outlet and exergy efficiency i.e. 62.4°C, 23.868% and 23.883% are achieved with bigger length of fins. For better thermal performance of collector internal fins with bigger length are recommended for absorber pipe.
- 25 November 2021
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 43 (1) , 6041-6051
Exergy analyses on fabricated cylindrical solar collectors with and without internal fins at various conditions
Effects of internal fins in absorber pipes are analysed experimentally on fabricated cylindrical collector with different lengths of fins at various flow rates on different days. Comparative analyses are done at different time intervals on same day at two cylindrical collectors. Axis of absorber pipe is orientated in North-South direction which is Mode-III type. Ambient/inlet/output temperatures, flow rates and useful heat gain rates are found with/without fins. Inlet/outlet rates of exergy, exergy gain rates and exergy efficiencies are found at different conditions. Experimental work is concluded; maximum outlet exergy and exergy gain rate i.e. 743.681W and 136.643W are found with fins considering Sun’s cone angle. Maximum temperature increment in fluid, percentage increment in exergy from inlet to outlet and exergy efficiency i.e. 62.4°C, 23.868% and 23.883% are achieved with bigger length of fins. For better thermal performance of collector internal fins with bigger length are recommended for absorber pipe.
- 15 September 2021
- Published by Springer Nature in International Journal of Energy and Water Resources
- Vol. 7 (1) , 65-83
Energy and exergy analyses of fabricated pyramid type solar distillation plant for optimization: An experimental work
- 15 September 2021
- Published by Springer Nature in International Journal of Energy and Water Resources
- Vol. 7 (1) , 65-83
Energy and exergy analyses of fabricated pyramid type solar distillation plant for optimization: An experimental work
- 14 May 2021
- Published by Wiley in Heat Transfer
- Vol. 50 (6) , 6259-6284
Energy and exergy analyses of fabricated solar drying system with smooth and rough surfaces at different conditions: A case study
For this experimental work, the solar dryer system has been fabricated. Various experiments have been performed to evaluate the performance of the fabricated dryer system. Energy and exergy concepts have been used for the assessment. And comparative analyses have also been done with smooth and rough surfaces: Grade 150 and Grade 300. This experimental work has been concluded as the maximum collector (i.e., 74°C) and cabinet temperatures (i.e., 66°C) are attained at 13:00 p.m. with Grade 300 surface. Maximum moisture loss (i.e., 35 g) and percentage moisture loss (i.e., 7.53%) are recorded at 13:00 p.m. again with a rough surface. Minimum exergy destruction rate (i.e., 0.294 W) but minimum exergy efficiency (i.e., 20.82%) are found at 17:00 p.m. with a black painted surface, which is not an acceptable condition. Maximum energy efficiency (i.e., 35.98%) and heat removal factor (i.e., 0.56) are obtained at 13:00 p.m. with a rough surface. The best performance from the fabricated solar system is received between 12:00 and 14:00 p.m. This study recommends rough surfaces and 12:00–13:00 p.m. timings for the solar drying system as the performance of the system is better in terms of energy–exergy.
- 14 May 2021
- Published by Wiley in Heat Transfer
- Vol. 50 (6) , 6259-6284
Energy and exergy analyses of fabricated solar drying system with smooth and rough surfaces at different conditions: A case study
For this experimental work, the solar dryer system has been fabricated. Various experiments have been performed to evaluate the performance of the fabricated dryer system. Energy and exergy concepts have been used for the assessment. And comparative analyses have also been done with smooth and rough surfaces: Grade 150 and Grade 300. This experimental work has been concluded as the maximum collector (i.e., 74°C) and cabinet temperatures (i.e., 66°C) are attained at 13:00 p.m. with Grade 300 surface. Maximum moisture loss (i.e., 35 g) and percentage moisture loss (i.e., 7.53%) are recorded at 13:00 p.m. again with a rough surface. Minimum exergy destruction rate (i.e., 0.294 W) but minimum exergy efficiency (i.e., 20.82%) are found at 17:00 p.m. with a black painted surface, which is not an acceptable condition. Maximum energy efficiency (i.e., 35.98%) and heat removal factor (i.e., 0.56) are obtained at 13:00 p.m. with a rough surface. The best performance from the fabricated solar system is received between 12:00 and 14:00 p.m. This study recommends rough surfaces and 12:00–13:00 p.m. timings for the solar drying system as the performance of the system is better in terms of energy–exergy.
- 23 April 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series C
- Vol. 102 (4) , 897-908
Entropy, Exergy and Entransy Analyses on Fabricated Shell and Spiral Tube Heat Exchanger
- 23 April 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series C
- Vol. 102 (4) , 897-908
Entropy, Exergy and Entransy Analyses on Fabricated Shell and Spiral Tube Heat Exchanger
- 14 April 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series C
- Vol. 102 (3) , 603-628
Analyse the Effect of Enthalpy/Temperature Drops in Pipelines on the Performance of Coal-Fired Thermal Power Plant
- 14 April 2021
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series C
- Vol. 102 (3) , 603-628
Analyse the Effect of Enthalpy/Temperature Drops in Pipelines on the Performance of Coal-Fired Thermal Power Plant
- 17 September 2020
- Published by Wiley in Heat Transfer
- Vol. 50 (2) , 1758-1775
Experimental exergy and entransy analyses on designed and fabricated crossflow heat exchanger
A crossflow heat exchanger (CFHEx) is designed and fabricated in a workshop. For designing this heat exchanger (HEx), the number of passes, frontal areas, HEx volumes, heat transfer areas, free‐flow areas, ratios of minimum free‐flow area to frontal area, densities, mass flow rates of flowing fluids, maximum/minimum heat capacities, heat capacity ratio, outlet temperatures of hot/cold fluids, average temperatures, mass velocities, Reynolds numbers, and convective heat transfer coefficients are evaluated by considering Colburn/friction factors. After fabrication of the HEx, effectiveness, exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, entransy dissipation number, and entransy effectiveness for hot/cold fluids sides are found at different flow rates and inlet temperatures of fluids. By experimental results, optimum operating conditions are found, which gives maximum effectiveness and entransy effectiveness but minimum rates of exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, and entransy dissipation number for the fabricated CFHEx. This study is concluded as follows: minimum exergy destruction and entransy dissipation rates (ie, 3.061 kJ/s·K and 1125.44 kJ·K/s, respectively) are found during experiment 2. Maximum entransy effectiveness of hot/cold fluids (ie, 0.689/0.21) is achieved in experiment 1. Moderate values of entransy dissipation number (ie, 4.689), entransy dissipation‐based thermal resistance (ie, 0.04 s·K/J), exergy destruction (ie, 3.845 kJ/s·K), and entransy dissipation (ie, 1374.04 kJ·K/s) rates are found during experiment 1. Maximum effectiveness (ie, 0.4) for the fabricated HEx is also obtained through experiment 1. After comparative analyses, it is found that experiment 1 provides optimum results, which shows the best performance of the fabricated HEx.
- 17 September 2020
- Published by Wiley in Heat Transfer
- Vol. 50 (2) , 1758-1775
Experimental exergy and entransy analyses on designed and fabricated crossflow heat exchanger
A crossflow heat exchanger (CFHEx) is designed and fabricated in a workshop. For designing this heat exchanger (HEx), the number of passes, frontal areas, HEx volumes, heat transfer areas, free‐flow areas, ratios of minimum free‐flow area to frontal area, densities, mass flow rates of flowing fluids, maximum/minimum heat capacities, heat capacity ratio, outlet temperatures of hot/cold fluids, average temperatures, mass velocities, Reynolds numbers, and convective heat transfer coefficients are evaluated by considering Colburn/friction factors. After fabrication of the HEx, effectiveness, exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, entransy dissipation number, and entransy effectiveness for hot/cold fluids sides are found at different flow rates and inlet temperatures of fluids. By experimental results, optimum operating conditions are found, which gives maximum effectiveness and entransy effectiveness but minimum rates of exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, and entransy dissipation number for the fabricated CFHEx. This study is concluded as follows: minimum exergy destruction and entransy dissipation rates (ie, 3.061 kJ/s·K and 1125.44 kJ·K/s, respectively) are found during experiment 2. Maximum entransy effectiveness of hot/cold fluids (ie, 0.689/0.21) is achieved in experiment 1. Moderate values of entransy dissipation number (ie, 4.689), entransy dissipation‐based thermal resistance (ie, 0.04 s·K/J), exergy destruction (ie, 3.845 kJ/s·K), and entransy dissipation (ie, 1374.04 kJ·K/s) rates are found during experiment 1. Maximum effectiveness (ie, 0.4) for the fabricated HEx is also obtained through experiment 1. After comparative analyses, it is found that experiment 1 provides optimum results, which shows the best performance of the fabricated HEx.
- Open Access
- 25 April 2020
- Published by Springer Nature in SN Applied Sciences
- Vol. 2 (5) , 1-17
Comparative exergy and exergy efficiency analyses of fabricated single and double slope solar still plants at Indore: case study
- 25 April 2020
- Published by Springer Nature in SN Applied Sciences
- Vol. 2 (5) , 1-17
Open AccessComparative exergy and exergy efficiency analyses of fabricated single and double slope solar still plants at Indore: case study
- 2 January 2020
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 20 (2) , 332-343
Performance analyses of coal-fired thermal power plant using parabolic solar collectors for feed water heaters
Parabolic solar collectors have been used for feed water heating process instead of extractions from steam turbines to enhance the power output and heat rate for a coal-fired thermal power plant. In this analytical work, entropy-exergy concepts have been applied on steam turbines and solar collectors at 60, 80 and 100% plant loads, and found different performance parameters with percentage variations in that parameters. After analyses, it has been found that maximum flow rate achieved for intermediate-pressure steam turbine with maximum outputs but maximum rates of exergy destruction and entropy generation at 100% load. Maximum percentage increments in total and net powers but minimum decrement in heat rate attained at 100% load which prove that plant must be operated at full load without extraction from turbine. Comparative analyses have also been shown maximum heat gain rate, inlet and exergy gain rates from the solar collectors found at 100% but minimum found at 60% load.
- 2 January 2020
- Published by Taylor & Francis in Australian Journal of Mechanical Engineering
- Vol. 20 (2) , 332-343
Performance analyses of coal-fired thermal power plant using parabolic solar collectors for feed water heaters
Parabolic solar collectors have been used for feed water heating process instead of extractions from steam turbines to enhance the power output and heat rate for a coal-fired thermal power plant. In this analytical work, entropy-exergy concepts have been applied on steam turbines and solar collectors at 60, 80 and 100% plant loads, and found different performance parameters with percentage variations in that parameters. After analyses, it has been found that maximum flow rate achieved for intermediate-pressure steam turbine with maximum outputs but maximum rates of exergy destruction and entropy generation at 100% load. Maximum percentage increments in total and net powers but minimum decrement in heat rate attained at 100% load which prove that plant must be operated at full load without extraction from turbine. Comparative analyses have also been shown maximum heat gain rate, inlet and exergy gain rates from the solar collectors found at 100% but minimum found at 60% load.
- 23 July 2019
- Published by Springer Nature in SN Applied Sciences
- Vol. 1 (8) , 901
Effect of surface roughness on the performance of heat exchanger
- 23 July 2019
- Published by Springer Nature in SN Applied Sciences
- Vol. 1 (8) , 901
Effect of surface roughness on the performance of heat exchanger