WSWilliam de Melo Silva

William de Melo Silva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


William de Melo Silva has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Américo Sheitiro Tabata

    Universidade Estadual Paulista Júlio de Mesquita Filho, Brazil

    1 shared publication
  • Camila Amorim Ribeiro

    Universidade Estadual Paulista Júlio de Mesquita Filho, Brazil

    1 shared publication
  • Cleiton Silva Marques

    Universidade Estadual Paulista Júlio de Mesquita Filho, Brazil

    1 shared publication
  • Deilson Elgui de Oliveira

    Universidade Estadual Paulista Júlio de Mesquita Filho, Brazil

    1 shared publication
  • J. R. Carneiro

    Pontifical Catholic University of Minas Gerais, Brazil

    1 shared publication
  • José Rubens Gonçalves Carneiro

    Pontifical Catholic University of Minas Gerais, Brazil

    1 shared publication

Latest Publications

  • Open Access

    Fibroblast and pre-osteoblast cell adhesive behavior on titanium alloy coated with diamond film

    by William de Melo Silva, Camila Amorim Ribeiro, Cleiton Silva Marques, Américo Sheitiro Tabata, Margarida Juri Saeki, Leonardo Iusuti Medeiros, Deilson Elgui de Oliveira

    It is well known that titanium alloys have mechanical strengths comparable to steels, as well as high corrosion resistance. Also, they have the advantage of promoting osseointegration, when used in medical and dental implants. This work aims to describe the adhesion properties of fibroblast and osteoblast cells on the surface of titanium aluminum vanadium alloy (Ti6Al4V). Three different conditions of the surface were investigated: smooth, rough and covered with diamond film. Conventional material characterizations were performed to the film which consisted in: Morphological visualization by scanning electron microscopy, confocal profilometry, X-ray diffraction pattern, Raman backscattering spectroscopy and atomic force microscopy. Biocompatibility tests of Ti6Al4V were performed using primary human fibroblasts and mouse pre-osteoblasts cell line MC3T3-E1. Overall, diamond films deposited on Ti6Al4V showed interesting results of uniformity and protection against cracks on to the surface, reasonable biocompatibility features if compared to uncovered ones, indicating that this film is an alternative for using in health care applications.


  • Open Access

    Methods of data analysis for the ball cratering test on TiN and DLC coated steel

    by W. M. Silva, P. S. Souza, J. R. Carneiro

    Titanium nitride (TiN) coatings are widely used in machining because of its mechanical characteristics which modify the surface of the substrate increasing the capacity of load support and reduction of friction, while a coating as diamond-like carbon (DLC), which also has interesting mechanical properties, needs better attention. In this sense, the development of new coatings such as DLC is as important as wear analysis techniques. This work discusses the methods available to assess abrasive wear of coatings. For this, it has been used the data of the crater volume formed in ball cratering test and compared the difference between the specific wear coefficients of substrate and coating (ks and kc). These coefficients depend of the methods used for data analyses, thus, it has been used four equations to calculate ks and kc. Moreover, profilometry (pf) has been used to calculate the volumes, and thus ks and kc. Also, the roughness of the coatings, the thickness, the images corresponding to the crater formed, the coefficient of friction, the data obtained in wear tests due to the volume removed and, in the end, a comparison between ks and kc by different methods of data analyzes are presented.


  • Open Access

    XPS, XRD and laser raman analysis of surface modified of 6150 steel substrates for the deposition of thick and adherent diamond-like carbon coatings

    by William de Melo Silva, José Rubens Gonçalves Carneiro, Vladimir Jesus Trava-Airoldi

    Although the 6150 steel has an excellent fatigue and impact resistance, it is unsuitable to operate it when the corrosion is a limited factor. We propose here a sequence of steel pre-treatment by carburizing, carbonitriding and nitriding in order to improve the poor adhesion between Diamond Like-Carbon coatings on steel. This sequence is our attempt to reduce the difference between the coefficients of thermal expansion of steel and DLC through the graded interface. This work demonstrates the quantitative analysis of the molecules present at surface using X-ray photoelectron spectroscopy. The crystallographic structures are investigated by X-ray diffraction which shows the formation of carbides and nitride phases. Raman spectroscopy reveals the carburizing surface characteristics where DLC coating is nucleated and grown at the substrate. At the end of the analysis it is possible to verify which molecules and phases are formed on the steel surface interface after each step of pre-treatment.