Andreas Pohl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Andreas Pohl has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Heinz-Wilhelm Hübers
German Aerospace Center (DLR), Institute for Space Research and Humboldt-Universitt zu Berlin, Department of Physics, Berlin, Germany
4 shared publications - Nikolay V. Abrosimov
Leibniz-Institut für Kristallzüchtung
3 shared publications - Roman Kh. Zhukavin
Institute for Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
3 shared publications - Sergey G. Pavlov
Institute of Optical Sensor Systems, German Aerospace Center (DLR), Berlin, Germany
3 shared publications - В.н. Шастин
Институт физики микроструктур Российской академии наук, Нижний Новгород, Россия
2 shared publications - B. Redlich
Radboud University Nijmegen, Institute for Molecules and Materials, FELIX Laboratory, Nijmegen, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 18 October 2023
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 55 (1) , 26-42
Comparative Raman spectroscopy of astrobiology relevant bio‐samples and planetary surface analogs under UV–VIS–IR excitation
We investigated the potential of a laser selection in the broad optical range, from ultraviolet through visible to infrared (excitation wavelengths of 325, 532, 785, and 1064 nm) for combined analysis of Earth‐relevant extremophiles (Xanthoria elegans, Buellia frigida, and green alga of Circinaria gyrosa), carbohydrate molecules, as well as Mars and Moon surface regolith simulants as analog mineral mixtures (P‐MRS, S‐MRS, LRS, and JSC‐1). We show that the optimization of the laser photon energy provides (for at least one of the chosen excitation wavelengths) high‐end quality Raman spectra for each examined sample. In most cases, the infrared spectral range is advanced for biological samples, while an excitation in the visible and ultraviolet spectral range is often favorable or at least sufficient for accurate identification/resolution of mineral phases under the illuminated laser spot on the planetary surface simulants. Ultraviolet excitation does not always deliver significant contrast of the Raman Stokes responses to the induced photoluminescence in the studied biomolecules. Most prominent features in the Raman spectra of the biological samples are assigned to their specific pigments, also considered as biomolecular signatures of the extremophiles. The critical issue of specific advantages and limitations of each particular excitation source implies study for gaining scientific return from Raman spectroscopy for exobiological prospecting, for instance, the best trade between a single or dual excitation wavelength(s) for both biological and geological spectral data.
- 18 October 2023
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 55 (1) , 26-42
Open AccessComparative Raman spectroscopy of astrobiology relevant bio‐samples and planetary surface analogs under UV–VIS–IR excitation
We investigated the potential of a laser selection in the broad optical range, from ultraviolet through visible to infrared (excitation wavelengths of 325, 532, 785, and 1064 nm) for combined analysis of Earth‐relevant extremophiles (Xanthoria elegans, Buellia frigida, and green alga of Circinaria gyrosa), carbohydrate molecules, as well as Mars and Moon surface regolith simulants as analog mineral mixtures (P‐MRS, S‐MRS, LRS, and JSC‐1). We show that the optimization of the laser photon energy provides (for at least one of the chosen excitation wavelengths) high‐end quality Raman spectra for each examined sample. In most cases, the infrared spectral range is advanced for biological samples, while an excitation in the visible and ultraviolet spectral range is often favorable or at least sufficient for accurate identification/resolution of mineral phases under the illuminated laser spot on the planetary surface simulants. Ultraviolet excitation does not always deliver significant contrast of the Raman Stokes responses to the induced photoluminescence in the studied biomolecules. Most prominent features in the Raman spectra of the biological samples are assigned to their specific pigments, also considered as biomolecular signatures of the extremophiles. The critical issue of specific advantages and limitations of each particular excitation source implies study for gaining scientific return from Raman spectroscopy for exobiological prospecting, for instance, the best trade between a single or dual excitation wavelength(s) for both biological and geological spectral data.
- 24 August 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11820, 1182006-3
Volume phase holographic gratings for the Raman spectrometer for MMX (RAX)
The Raman Spectrometer for MMX (RAX) as part of the JAXAs Martian Moons eXploration (MMX) mission, to be launched in 2024, is designed for in-situ science on the Martian moon Phobos. It is installed on the MMX rover to investigate the Phobos surface mineralogy complementary to the anticipated sample return mission of MMX reaching earth in 2029 [1]. To ensure high Raman signals with the RAX instrument we utilize a volume phase holographic (VPH) grating as diffracting element. The VPH grating diffracts light by refractive index modulations within a thin layer of transmissive gelatin sandwiched between two glass substrates. Optimized VPH grating parameters combined with a small spectral bandwidth lead to peak efficiencies approaching up to 100 % [2]. Due to the rather small Raman scattering efficiency they are particular suitable for space instrumentation, where initial laser intensity is relatively limited [3]. We have designed an optical setup for the characterization of 1st order diffraction efficiency and wave front aberration evaluation. A laser source similar in emission characteristics to the RAX laser (Nd:YAG at 532 nm) is widened to 14.2 mm beam diameter before illuminating the VPH grating. The VPH grating is installed axis-centered on a rotation platform within a second outer rotational platform mounting a camera for optical verification or a laser power meter for the diffraction efficiency measurement. The VPH gratings reach diffraction efficiencies up to 87 % within their specified spectral range with diffraction limited patterns nearly identical to the undisturbed reference beam and dispersed only due to the laser band width.
- 24 August 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11820, 1182006-3
Volume phase holographic gratings for the Raman spectrometer for MMX (RAX)
The Raman Spectrometer for MMX (RAX) as part of the JAXAs Martian Moons eXploration (MMX) mission, to be launched in 2024, is designed for in-situ science on the Martian moon Phobos. It is installed on the MMX rover to investigate the Phobos surface mineralogy complementary to the anticipated sample return mission of MMX reaching earth in 2029 [1]. To ensure high Raman signals with the RAX instrument we utilize a volume phase holographic (VPH) grating as diffracting element. The VPH grating diffracts light by refractive index modulations within a thin layer of transmissive gelatin sandwiched between two glass substrates. Optimized VPH grating parameters combined with a small spectral bandwidth lead to peak efficiencies approaching up to 100 % [2]. Due to the rather small Raman scattering efficiency they are particular suitable for space instrumentation, where initial laser intensity is relatively limited [3]. We have designed an optical setup for the characterization of 1st order diffraction efficiency and wave front aberration evaluation. A laser source similar in emission characteristics to the RAX laser (Nd:YAG at 532 nm) is widened to 14.2 mm beam diameter before illuminating the VPH grating. The VPH grating is installed axis-centered on a rotation platform within a second outer rotational platform mounting a camera for optical verification or a laser power meter for the diffraction efficiency measurement. The VPH gratings reach diffraction efficiencies up to 87 % within their specified spectral range with diffraction limited patterns nearly identical to the undisturbed reference beam and dispersed only due to the laser band width.
- Open Access
- 5 August 2020
- Published by Pleiades Publishing Ltd in Semiconductors
- Vol. 54 (8) , 969-974
Frequency Tuning of Terahertz Stimulated Emission under the Intracenter Optical Excitation of Uniaxially Stressed Si:Bi
The results of experimental and theoretical investigations of terahertz-emission-spectrum tuning by means of uniaxial stress of a silicon crystal doped with shallow bismuth donors are presented for the case of intracenter optical excitation. The frequency tuning of two emission lines of the bismuth donor is shown for the case of uniaxial strain along the [001] crystallographic direction. The cross sections of stimulated Raman scattering for uniaxially stressed bismuth-doped silicon are calculated.
- 5 August 2020
- Published by Pleiades Publishing Ltd in Semiconductors
- Vol. 54 (8) , 969-974
Open AccessFrequency Tuning of Terahertz Stimulated Emission under the Intracenter Optical Excitation of Uniaxially Stressed Si:Bi
The results of experimental and theoretical investigations of terahertz-emission-spectrum tuning by means of uniaxial stress of a silicon crystal doped with shallow bismuth donors are presented for the case of intracenter optical excitation. The frequency tuning of two emission lines of the bismuth donor is shown for the case of uniaxial strain along the [001] crystallographic direction. The cross sections of stimulated Raman scattering for uniaxially stressed bismuth-doped silicon are calculated.
- Open Access
- 1 January 2020
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 54 (8) , 816
Перестройка спектра терагерцового стимулированного излучения при внутрицентровом оптическом возбуждении одноосно-деформированного Si : Bi
Перестройка спектра терагерцового стимулированного излучения при внутрицентровом оптическом возбуждении одноосно-деформированного Si : Bi
- 1 January 2020
- Published by Ioffe Institute Russian Academy of Sciences in Журнал технической физики
- Vol. 54 (8) , 816
Open AccessПерестройка спектра терагерцового стимулированного излучения при внутрицентровом оптическом возбуждении одноосно-деформированного Si : Bi
Перестройка спектра терагерцового стимулированного излучения при внутрицентровом оптическом возбуждении одноосно-деформированного Si : Bi
- 1 January 2019
- Published by Ioffe Institute Russian Academy of Sciences in Физика и техника полупроводников
- Vol. 53 (9) , 1285
Стимулированное терагерцовое излучение доноров висмута в одноосно-деформированном кремнии при внутрицентровом оптическом возбуждении
The results of the experimental observation of stimulated terahertz emission under optical intracenter excitation of uniaxially strained bismuth-doped silicon are presented. Pumping in the presented experiment is performed using a FELIX free-electron laser. It is shown that uniaxial strain of the silicon crystal leads to a significant change in the stimulated emission spectrum of the impurity.
- 1 January 2019
- Published by Ioffe Institute Russian Academy of Sciences in Физика и техника полупроводников
- Vol. 53 (9) , 1285
Стимулированное терагерцовое излучение доноров висмута в одноосно-деформированном кремнии при внутрицентровом оптическом возбуждении
The results of the experimental observation of stimulated terahertz emission under optical intracenter excitation of uniaxially strained bismuth-doped silicon are presented. Pumping in the presented experiment is performed using a FELIX free-electron laser. It is shown that uniaxial strain of the silicon crystal leads to a significant change in the stimulated emission spectrum of the impurity.
- 27 October 2015
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 37 (2) , 175-188
Identification of Unknown Substances by Terahertz Spectroscopy and Multivariate Data Analysis
- 27 October 2015
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 37 (2) , 175-188
Identification of Unknown Substances by Terahertz Spectroscopy and Multivariate Data Analysis