Geir Hoff
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Geir Hoff has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Michael Bretthauer
Institute of Health and Society, University of Oslo, Oslo, Norway
12 shared publications - Magnus Løberg
Clinical Effectiveness Research Group, University of Oslo, and Clinical Effectiveness Research Group, Oslo University Hospital, Oslo, Norway (M.L., M.B., M.K.)
5 shared publications - Kjetil Garborg
Clinical Effectiveness Research Group, Oslo University Hospital, and Clinical Effectiveness Research Group, University of Oslo, Oslo, Norway (M.B., M.K., M.L., K.K.G.)
4 shared publications - Mette Kalager
The Cancer Registry of Norway, P.O.B 5313 Majorstuen, N-0304 Oslo, Norway
4 shared publications Oeyvind Holme
4 shared publicationsJostein Sauar
3 shared publications
Latest Publications
- Open Access
- 1 February 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 119 (7) , 1402-1411
Low-Dose Aspirin and Prevention of Colorectal Cancer: Evidence From a Nationwide Registry-Based Cohort in Norway
INTRODUCTION: To examine the association between low-dose aspirin use and risk of colorectal cancer (CRC). METHODS: In this nationwide cohort study, we identified individuals aged 50 years or older residing for 6 months or more in Norway in 2004–2018 and obtained data from national registers on drug prescriptions, cancer occurrence, and sociodemographic factors. Multivariable Cox regression models were used to estimate the association between low-dose aspirin use and CRC risk. In addition, we calculated the number of CRC potentially averted by low-dose aspirin use. RESULTS: We included 2,186,390 individuals. During the median follow-up of 10.9 years, 579,196 (26.5%) used low-dose aspirin, and 38,577 (1.8%) were diagnosed with CRC. Current use of aspirin vs never use was associated with lower CRC risk (hazard ratio [HR] 0.87, 95% confidence interval [CI] 0.84–0.90). The association was more pronounced for metastatic CRC (HR 0.79; 95% CI 0.74–0.84) than regionally advanced (HR 0.89; 95% CI 0.85–0.92) and localized CRC (HR 0.93; 95% CI 0.87–1.00; P heterogeneity = 0.001). A significant trend was found between duration of current use and CRC risk: HR 0.91 (95% CI 0.86–0.95) for P trend < 0.001). For past use, HR were 0.89 (95% CI 0.84–0.94) for P-trend < 0.001). We estimated that aspirin use averted 1,073 cases of CRC (95% CI 818–1,338) in the study period. DISCUSSION: In this nationwide cohort, use of low-dose aspirin was associated with a lower risk of CRC.
- 1 February 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 119 (7) , 1402-1411
Open AccessLow-Dose Aspirin and Prevention of Colorectal Cancer: Evidence From a Nationwide Registry-Based Cohort in Norway
INTRODUCTION: To examine the association between low-dose aspirin use and risk of colorectal cancer (CRC). METHODS: In this nationwide cohort study, we identified individuals aged 50 years or older residing for 6 months or more in Norway in 2004–2018 and obtained data from national registers on drug prescriptions, cancer occurrence, and sociodemographic factors. Multivariable Cox regression models were used to estimate the association between low-dose aspirin use and CRC risk. In addition, we calculated the number of CRC potentially averted by low-dose aspirin use. RESULTS: We included 2,186,390 individuals. During the median follow-up of 10.9 years, 579,196 (26.5%) used low-dose aspirin, and 38,577 (1.8%) were diagnosed with CRC. Current use of aspirin vs never use was associated with lower CRC risk (hazard ratio [HR] 0.87, 95% confidence interval [CI] 0.84–0.90). The association was more pronounced for metastatic CRC (HR 0.79; 95% CI 0.74–0.84) than regionally advanced (HR 0.89; 95% CI 0.85–0.92) and localized CRC (HR 0.93; 95% CI 0.87–1.00; P heterogeneity = 0.001). A significant trend was found between duration of current use and CRC risk: HR 0.91 (95% CI 0.86–0.95) for P trend < 0.001). For past use, HR were 0.89 (95% CI 0.84–0.94) for P-trend < 0.001). We estimated that aspirin use averted 1,073 cases of CRC (95% CI 818–1,338) in the study period. DISCUSSION: In this nationwide cohort, use of low-dose aspirin was associated with a lower risk of CRC.
- Open Access
- 8 November 2018
- Published by Springer Nature in BMC Gastroenterology
- Vol. 18 (1) , 171
Evaluating gut microbiota profiles from archived fecal samples
Associations between colorectal cancer and microbiota have been identified. Archived fecal samples might be valuable sample sources for investigating causality in carcinogenesis and biomarkers discovery due to the potential of performing longitudinal studies. However, the quality, quantity and stability of the gut microbiota in these fecal samples must be assessed prior to such studies. We evaluated i) cross-contamination during analysis for fecal blood and ii) evaporation in stored perforated fecal immunochemical tests (iFOBT) samples, iii) temperature stability as well as iv) comparison of the gut microbiota diversity and composition in archived, iFOBT and fresh fecal samples in order to assess feasibility of large scale microbiota studies. The microbiota profiles were obtained by sequencing the V3-V4 region of 16S rDNA gene. The iFOBT does not introduce any cross-sample contamination detectable by qPCR. Neither could we detect evaporation during freeze-thaw cycle of perforated iFOBT samples. Our results confirm room temperature stability of the gut microbiome. Diverse microbial profiles were achieved in 100% of fresh, 81% of long-term archived and 96% of iFOBT samples. Microbial diversity and composition were comparable between fresh and iFOBT samples, however, diversity differed significantly between long-term archived, fresh and iFOBT samples. Our data showed that it is feasible to exploit archived fecal sample sets originally collected for testing of fecal blood. The advantages of using these sample sets for microbial biomarker discovery and longitudinal observational studies are the availability of high-quality diagnostic and follow-up data. However, care must be taken when microbiota are profiled in long-term archived fecal samples.
- 8 November 2018
- Published by Springer Nature in BMC Gastroenterology
- Vol. 18 (1) , 171
Open AccessEvaluating gut microbiota profiles from archived fecal samples
Associations between colorectal cancer and microbiota have been identified. Archived fecal samples might be valuable sample sources for investigating causality in carcinogenesis and biomarkers discovery due to the potential of performing longitudinal studies. However, the quality, quantity and stability of the gut microbiota in these fecal samples must be assessed prior to such studies. We evaluated i) cross-contamination during analysis for fecal blood and ii) evaporation in stored perforated fecal immunochemical tests (iFOBT) samples, iii) temperature stability as well as iv) comparison of the gut microbiota diversity and composition in archived, iFOBT and fresh fecal samples in order to assess feasibility of large scale microbiota studies. The microbiota profiles were obtained by sequencing the V3-V4 region of 16S rDNA gene. The iFOBT does not introduce any cross-sample contamination detectable by qPCR. Neither could we detect evaporation during freeze-thaw cycle of perforated iFOBT samples. Our results confirm room temperature stability of the gut microbiome. Diverse microbial profiles were achieved in 100% of fresh, 81% of long-term archived and 96% of iFOBT samples. Microbial diversity and composition were comparable between fresh and iFOBT samples, however, diversity differed significantly between long-term archived, fresh and iFOBT samples. Our data showed that it is feasible to exploit archived fecal sample sets originally collected for testing of fecal blood. The advantages of using these sample sets for microbial biomarker discovery and longitudinal observational studies are the availability of high-quality diagnostic and follow-up data. However, care must be taken when microbiota are profiled in long-term archived fecal samples.
- Open Access
- 5 June 2018
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 168 (11) , 775-782
Long-Term Effectiveness of Sigmoidoscopy Screening on Colorectal Cancer Incidence and Mortality in Women and Men
The long-term effects of sigmoidoscopy screening on colorectal cancer (CRC) incidence and mortality in women and men are unclear. To determine the effectiveness of flexible sigmoidoscopy screening after 15 years of follow-up in women and men. Randomized controlled trial. (ClinicalTrials.gov: NCT00119912) Oslo and Telemark County, Norway. Adults aged 50 to 64 years at baseline without prior CRC. Screening (between 1999 and 2001) with flexible sigmoidoscopy with and without additional fecal blood testing versus no screening. Participants with positive screening results were offered colonoscopy. Age-adjusted CRC incidence and mortality stratified by sex. Of 98 678 persons, 20 552 were randomly assigned to screening and 78 126 to no screening. Adherence rates were 64.7% in women and 61.4% in men. Median follow-up was 14.8 years. The absolute risks for CRC in women were 1.86% in the screening group and 2.05% in the control group (risk difference, −0.19 percentage point [95% CI, −0.49 to 0.11 percentage point]; HR, 0.92 [CI, 0.79 to 1.07]). In men, the corresponding risks were 1.72% and 2.50%, respectively (risk difference, −0.78 percentage point [CI, −1.08 to −0.48 percentage points]; hazard ratio [HR], 0.66 [CI, 0.57 to 0.78]) (P for heterogeneity = 0.004). The absolute risks for death of CRC in women were 0.60% in the screening group and 0.59% in the control group (risk difference, 0.01 percentage point [CI, −0.16 to 0.18 percentage point]; HR, 1.01 [CI, 0.77 to 1.33]). The corresponding risks for death of CRC in men were 0.49% and 0.81%, respectively (risk difference, −0.33 percentage point [CI, −0.49 to −0.16 percentage point]; HR, 0.63 [CI, 0.47 to 0.83]) (P for heterogeneity = 0.014). Follow-up through national registries. Offering sigmoidoscopy screening in Norway reduced CRC incidence and mortality in men but had little or no effect in women. Norwegian government and Norwegian Cancer Society.
- 5 June 2018
- Published by American College of Physicians in Annals of Internal Medicine
- Vol. 168 (11) , 775-782
Open AccessLong-Term Effectiveness of Sigmoidoscopy Screening on Colorectal Cancer Incidence and Mortality in Women and Men
The long-term effects of sigmoidoscopy screening on colorectal cancer (CRC) incidence and mortality in women and men are unclear. To determine the effectiveness of flexible sigmoidoscopy screening after 15 years of follow-up in women and men. Randomized controlled trial. (ClinicalTrials.gov: NCT00119912) Oslo and Telemark County, Norway. Adults aged 50 to 64 years at baseline without prior CRC. Screening (between 1999 and 2001) with flexible sigmoidoscopy with and without additional fecal blood testing versus no screening. Participants with positive screening results were offered colonoscopy. Age-adjusted CRC incidence and mortality stratified by sex. Of 98 678 persons, 20 552 were randomly assigned to screening and 78 126 to no screening. Adherence rates were 64.7% in women and 61.4% in men. Median follow-up was 14.8 years. The absolute risks for CRC in women were 1.86% in the screening group and 2.05% in the control group (risk difference, −0.19 percentage point [95% CI, −0.49 to 0.11 percentage point]; HR, 0.92 [CI, 0.79 to 1.07]). In men, the corresponding risks were 1.72% and 2.50%, respectively (risk difference, −0.78 percentage point [CI, −1.08 to −0.48 percentage points]; hazard ratio [HR], 0.66 [CI, 0.57 to 0.78]) (P for heterogeneity = 0.004). The absolute risks for death of CRC in women were 0.60% in the screening group and 0.59% in the control group (risk difference, 0.01 percentage point [CI, −0.16 to 0.18 percentage point]; HR, 1.01 [CI, 0.77 to 1.33]). The corresponding risks for death of CRC in men were 0.49% and 0.81%, respectively (risk difference, −0.33 percentage point [CI, −0.49 to −0.16 percentage point]; HR, 0.63 [CI, 0.47 to 0.83]) (P for heterogeneity = 0.014). Follow-up through national registries. Offering sigmoidoscopy screening in Norway reduced CRC incidence and mortality in men but had little or no effect in women. Norwegian government and Norwegian Cancer Society.
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S451
Su1036 Interval Colorectal Cancers after Screening - More Aggressive than Clinical Cancers?
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S451
Su1036 Interval Colorectal Cancers after Screening - More Aggressive than Clinical Cancers?
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S758-S759
Mo1710 Effectiveness of Flexible Sigmoidoscopy Screening in Men and Women. A Meta-Analysis of Three Large Randomized Trials
- 1 April 2016
- Published by Elsevier in Gastroenterology
- Vol. 150 (4) , S758-S759
Mo1710 Effectiveness of Flexible Sigmoidoscopy Screening in Men and Women. A Meta-Analysis of Three Large Randomized Trials
- Open Access
- 30 November 2015
- Published by Springer Nature in Trials
- Vol. 16 (1) , 541
Bounding the per-protocol effect in randomized trials: an application to colorectal cancer screening
The per-protocol effect is the effect that would have been observed in a randomized trial had everybody followed the protocol. Though obtaining a valid point estimate for the per-protocol effect requires assumptions that are unverifiable and often implausible, lower and upper bounds for the per-protocol effect may be estimated under more plausible assumptions. Strategies for obtaining bounds, known as “partial identification” methods, are especially promising in randomized trials. We estimated bounds for the per-protocol effect of colorectal cancer screening in the Norwegian Colorectal Cancer Prevention trial, a randomized trial of one-time sigmoidoscopy screening in 98,792 men and women aged 50–64 years. The screening was not available to the control arm, while approximately two thirds of individuals in the treatment arm attended the screening. Study outcomes included colorectal cancer incidence and mortality over 10 years of follow-up. Without any assumptions, the data alone provide little information about the size of the effect. Under the assumption that randomization had no effect on the outcome except through screening, a point estimate for the risk under no screening and bounds for the risk under screening are achievable. Thus, the 10-year risk difference for colorectal cancer was estimated to be at least −0.6 % but less than 37.0 %. Bounds for the risk difference for colorectal cancer mortality (–0.2 to 37.4 %) and all-cause mortality (–5.1 to 32.6 %) had similar widths. These bounds appear helpful in quantifying the maximum possible effectiveness, but cannot rule out harm. By making further assumptions about the effect in the subpopulation who would not attend screening regardless of their randomization arm, narrower bounds can be achieved. Bounding the per-protocol effect under several sets of assumptions illuminates our reliance on unverifiable assumptions, highlights the range of effect sizes we are most confident in, and can sometimes demonstrate whether to expect certain subpopulations to receive more benefit or harm than others. Clinicaltrials.gov identifier NCT00119912 (registered 6 July 2005)
- 30 November 2015
- Published by Springer Nature in Trials
- Vol. 16 (1) , 541
Open AccessBounding the per-protocol effect in randomized trials: an application to colorectal cancer screening
The per-protocol effect is the effect that would have been observed in a randomized trial had everybody followed the protocol. Though obtaining a valid point estimate for the per-protocol effect requires assumptions that are unverifiable and often implausible, lower and upper bounds for the per-protocol effect may be estimated under more plausible assumptions. Strategies for obtaining bounds, known as “partial identification” methods, are especially promising in randomized trials. We estimated bounds for the per-protocol effect of colorectal cancer screening in the Norwegian Colorectal Cancer Prevention trial, a randomized trial of one-time sigmoidoscopy screening in 98,792 men and women aged 50–64 years. The screening was not available to the control arm, while approximately two thirds of individuals in the treatment arm attended the screening. Study outcomes included colorectal cancer incidence and mortality over 10 years of follow-up. Without any assumptions, the data alone provide little information about the size of the effect. Under the assumption that randomization had no effect on the outcome except through screening, a point estimate for the risk under no screening and bounds for the risk under screening are achievable. Thus, the 10-year risk difference for colorectal cancer was estimated to be at least −0.6 % but less than 37.0 %. Bounds for the risk difference for colorectal cancer mortality (–0.2 to 37.4 %) and all-cause mortality (–5.1 to 32.6 %) had similar widths. These bounds appear helpful in quantifying the maximum possible effectiveness, but cannot rule out harm. By making further assumptions about the effect in the subpopulation who would not attend screening regardless of their randomization arm, narrower bounds can be achieved. Bounding the per-protocol effect under several sets of assumptions illuminates our reliance on unverifiable assumptions, highlights the range of effect sizes we are most confident in, and can sometimes demonstrate whether to expect certain subpopulations to receive more benefit or harm than others. Clinicaltrials.gov identifier NCT00119912 (registered 6 July 2005)
- 20 November 2014
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 47 (03) , 192-199
Water exchange versus carbon dioxide insufflation in unsedated colonoscopy: a multicenter randomized controlled trial
Background and study aims: Compared with air insufflation, water exchange and carbon dioxide (CO2) insufflation have been shown to reduce colonoscopy discomfort; however, head-to-head studies of the two methods are lacking. We aimed to compare water exchange and CO2 insufflation directly with regard to pain during primary unsedated colonoscopy. Methods: Patients willing to undergo unsedated colonoscopy at three centers in Norway and Poland were randomized 1:1 to water exchange or CO2 insufflation during colonoscope insertion. Patients were blinded to group allocation. The primary end point was the proportion of patients reporting moderate or severe procedural pain on a 4-point verbal rating scale (VRS-4) at discharge. Secondary outcomes included the proportion of patients reporting no pain on the VRS-4. Results: A total of 473 patients were randomized. A discharge pain questionnaire was completed by 226 of 234 patients (97 %) in the water exchange group versus 226 of 239 patients (95 %) in the CO2 group (P = 0.37). Moderate or severe pain was reported by 47 of 226 patients (21 %) in the water exchange group versus 60 of 226 patients (27 %) in the CO2 group (P = 0.15). No pain was reported by 100 of 226 patients (44 %) and 69 of 226 patients (31 %) in the water exchange and CO2 groups, respectively (P = 0.003). On-demand sedation was used in 15 patients (6 %) in each group (P = 0.95). Conclusions: There was no significant reduction in moderate or severe pain in a comparison of water exchange with CO2 insufflation. The secondary outcome of no pain was significantly more frequent in the water exchange group. Clinical trials registry number: NCT01633333.
- 20 November 2014
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 47 (03) , 192-199
Water exchange versus carbon dioxide insufflation in unsedated colonoscopy: a multicenter randomized controlled trial
Background and study aims: Compared with air insufflation, water exchange and carbon dioxide (CO2) insufflation have been shown to reduce colonoscopy discomfort; however, head-to-head studies of the two methods are lacking. We aimed to compare water exchange and CO2 insufflation directly with regard to pain during primary unsedated colonoscopy. Methods: Patients willing to undergo unsedated colonoscopy at three centers in Norway and Poland were randomized 1:1 to water exchange or CO2 insufflation during colonoscope insertion. Patients were blinded to group allocation. The primary end point was the proportion of patients reporting moderate or severe procedural pain on a 4-point verbal rating scale (VRS-4) at discharge. Secondary outcomes included the proportion of patients reporting no pain on the VRS-4. Results: A total of 473 patients were randomized. A discharge pain questionnaire was completed by 226 of 234 patients (97 %) in the water exchange group versus 226 of 239 patients (95 %) in the CO2 group (P = 0.37). Moderate or severe pain was reported by 47 of 226 patients (21 %) in the water exchange group versus 60 of 226 patients (27 %) in the CO2 group (P = 0.15). No pain was reported by 100 of 226 patients (44 %) and 69 of 226 patients (31 %) in the water exchange and CO2 groups, respectively (P = 0.003). On-demand sedation was used in 15 patients (6 %) in each group (P = 0.95). Conclusions: There was no significant reduction in moderate or severe pain in a comparison of water exchange with CO2 insufflation. The secondary outcome of no pain was significantly more frequent in the water exchange group. Clinical trials registry number: NCT01633333.
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB178
838 Water Exchange vs. Carbon Dioxide Insufflation in Unsedated Colonoscopy - a Multicenter, Single-Blinded, Randomized Controlled Trial
- 1 May 2014
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 79 (5) , AB178
838 Water Exchange vs. Carbon Dioxide Insufflation in Unsedated Colonoscopy - a Multicenter, Single-Blinded, Randomized Controlled Trial
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB179-AB180
1173 Improved Colonoscopy Screening With an Ultra Thin Colonoscope: A Randomized Controlled Trial
- 1 April 2012
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 75 (4) , AB179-AB180
1173 Improved Colonoscopy Screening With an Ultra Thin Colonoscope: A Randomized Controlled Trial
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Magnetic Endoscopic Imaging Versus Fluoroscopy in a Routine Colonoscopy Setting: A Randomized Controlled Trial
- 1 May 2011
- Published by Elsevier in Gastroenterology
- Vol. 140 (5)
Magnetic Endoscopic Imaging Versus Fluoroscopy in a Routine Colonoscopy Setting: A Randomized Controlled Trial