Dianyuan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dianyuan Li has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Chunzhu Xue
Department of Thoracic and Cardiac Surgery, The First People’s Hospital of Guangyuan, Sichuan, China
5 shared publicationsCunfu Mu
Department of Thoracic and Cardiac Surgery, The First People’s Hospital of Guangyuan, Sichuan, China
5 shared publicationsGen Zhang
Department of Cardiovascular Surgery, The Affiliated Traditional Chinese Medicine Hospital of Southwest Medical University, Sichuan, China
5 shared publicationsWenlin Zhang
Department of Thoracic and Cardiac Surgery, The First People’s Hospital of Guangyuan, Sichuan, China
5 shared publicationsXianzhi Wang
Department of Thoracic and Cardiac Surgery, The First People’s Hospital of Guangyuan, Sichuan, China
5 shared publicationsJixiang Liang
The State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Shaanxi, China
4 shared publications
Latest Publications
- Open Access
- 9 May 2025
- Published by African Journals Online (AJOL) in African Health Sciences
- Vol. 25 (1) , 205-229.
Mild hypothermia (35°C) reduces myocardial ischemia-reperfusion injury and attenuates hypoxia induced apoptosis of H9C2 cardiomyocytes by changing the phosphorylation level of Connexin43 (Cx43) protein
Background: The purpose of this study was to investigate the effect of connexin 43 (Cx43) on myocardial cell apoptosis under mild hypothermia and its potential for treating ischemia reperfusion injury.Methodology: In vivo experiments were conducted on rats, using an ischemia-reperfusion model, small animal ultrasound imaging system, and relevant biochemical assays to measure myocardial function, infarction area, and tissue damage. In vitro experiments were performed on H9C2 cells using an oxygen-glucose deprivation and recovery model, and various assays were used to assess cell viability, apoptosis, and biochemical changes.Results: Mild hypothermia (35°C) was found to reduce ischemia-reperfusion injury, enhance myocardial function, decrease infarction area, and increase the expression of phosphorylated Cx43 and protein kinase C in myocardial tissue. In vitro, mild hypothermia enhanced cell viability, decreased gap junction permeability, downregulated pro-apoptotic factors, and upregulated anti-apoptotic factors, while also increasing the levels of calcium and superoxide dismutase and decreasing the level of malondialdehyde.Conclusions: Mild hypothermia can protect against myocardial ischemia-reperfusion injury by regulating the level of phosphorylated Cx43 protein, which reduces myocardial cell apoptosis and enhances cardiac function. This study highlights the potential therapeutic benefits of mild hypothermia in treating ischemia-reperfusion injury. Keywords: Mild hypothermia; Cx43; ischemia reperfusion; hypoxia; apoptosis.
- 9 May 2025
- Published by African Journals Online (AJOL) in African Health Sciences
- Vol. 25 (1) , 205-229.
Open AccessMild hypothermia (35°C) reduces myocardial ischemia-reperfusion injury and attenuates hypoxia induced apoptosis of H9C2 cardiomyocytes by changing the phosphorylation level of Connexin43 (Cx43) protein
Background: The purpose of this study was to investigate the effect of connexin 43 (Cx43) on myocardial cell apoptosis under mild hypothermia and its potential for treating ischemia reperfusion injury.Methodology: In vivo experiments were conducted on rats, using an ischemia-reperfusion model, small animal ultrasound imaging system, and relevant biochemical assays to measure myocardial function, infarction area, and tissue damage. In vitro experiments were performed on H9C2 cells using an oxygen-glucose deprivation and recovery model, and various assays were used to assess cell viability, apoptosis, and biochemical changes.Results: Mild hypothermia (35°C) was found to reduce ischemia-reperfusion injury, enhance myocardial function, decrease infarction area, and increase the expression of phosphorylated Cx43 and protein kinase C in myocardial tissue. In vitro, mild hypothermia enhanced cell viability, decreased gap junction permeability, downregulated pro-apoptotic factors, and upregulated anti-apoptotic factors, while also increasing the levels of calcium and superoxide dismutase and decreasing the level of malondialdehyde.Conclusions: Mild hypothermia can protect against myocardial ischemia-reperfusion injury by regulating the level of phosphorylated Cx43 protein, which reduces myocardial cell apoptosis and enhances cardiac function. This study highlights the potential therapeutic benefits of mild hypothermia in treating ischemia-reperfusion injury. Keywords: Mild hypothermia; Cx43; ischemia reperfusion; hypoxia; apoptosis.
- Open Access
- 7 February 2023
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 23 (1) , 1-8
Causes and treatment strategies of unilateral leaflet escape of bileaflet mechanical prosthetic heart valves after surgery: a case series
Background: During the eleven years from 2010 to 2021, preliminary statistics have shown that Fuwai Hospital completed 23,571 mechanical valve replacements for various types of valves, and 1139 mechanical valve replacements were performed in Guangyuan First People's Hospital. Only two patients developed valve leaflet escape, so valve leaflet escape is a rare postoperative complication. Case presentation: In 2010 and 2021, two patients were selected after they had unilateral leaflet escape after having mechanical valve replacements in Fuwai Hospital of Chinese Academy of Medical Sciences and Guangyuan First People's Hospital. Both patients underwent reoperations with the classic operation and the new bileaflet mechanical prosthetic heart valve was sutured. The treatment of detached single lobe and distal vessel was comprehensively determined, and the condition was treated according to the patient's symptoms, CT results, ultrasound results and other test results, as well as whether this detached lobe caused any abnormal hemodynamics of the distal vessel. The patient with mechanical aortic valve escape completed the 10-year follow-up, and patient with mechanical mitral valve escape completed the 3-month follow-up. there was no thrombosis or hematoma at the embolic site; the patient had no lower limb symptoms. Conclusions: The reason for the leaflet escape may be related to the valve design and the leaflet material. If the detached leaflets are damaged and if the distal blood vessels are affected, simultaneous surgical treatment is required. Those patients whose vessels were not damaged by the valve lobe should be carefully monitored.
- 7 February 2023
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 23 (1) , 1-8
Open AccessCauses and treatment strategies of unilateral leaflet escape of bileaflet mechanical prosthetic heart valves after surgery: a case series
Background: During the eleven years from 2010 to 2021, preliminary statistics have shown that Fuwai Hospital completed 23,571 mechanical valve replacements for various types of valves, and 1139 mechanical valve replacements were performed in Guangyuan First People's Hospital. Only two patients developed valve leaflet escape, so valve leaflet escape is a rare postoperative complication. Case presentation: In 2010 and 2021, two patients were selected after they had unilateral leaflet escape after having mechanical valve replacements in Fuwai Hospital of Chinese Academy of Medical Sciences and Guangyuan First People's Hospital. Both patients underwent reoperations with the classic operation and the new bileaflet mechanical prosthetic heart valve was sutured. The treatment of detached single lobe and distal vessel was comprehensively determined, and the condition was treated according to the patient's symptoms, CT results, ultrasound results and other test results, as well as whether this detached lobe caused any abnormal hemodynamics of the distal vessel. The patient with mechanical aortic valve escape completed the 10-year follow-up, and patient with mechanical mitral valve escape completed the 3-month follow-up. there was no thrombosis or hematoma at the embolic site; the patient had no lower limb symptoms. Conclusions: The reason for the leaflet escape may be related to the valve design and the leaflet material. If the detached leaflets are damaged and if the distal blood vessels are affected, simultaneous surgical treatment is required. Those patients whose vessels were not damaged by the valve lobe should be carefully monitored.
- Open Access
- 14 November 2022
- Published by Springer Nature in Molecular Biology Reports
- Vol. 50 (1) , 731-737
TRIM11, a new target of p53, facilitates the migration and invasion of nasopharyngeal carcinoma cells
Background: Although tripartite motif-containing protein 11 (TRIM11) is known to be associated with a variety of cancers, its role in nasopharyngeal carcinoma (NPC) is unclear. Methods and results: To investigate the role of TRIM11 in NPC, TRIM11 was stably overexpressed in 6–10B and CNE2 cells with lentiviral vectors and knocked down in S18 and 5–8F cells using the CRISPR/Cas9 system. Transwell assays and wound-healing assays revealed that TRIM11 facilitated the migration and invasion of NPC cells. Mechanistically, we found that p53 inhibits TRIM11 expression by binding to its promoter. Conclusions: TRIM11 may serve as a potential diagnostic marker for NPC and has a certain therapeutic value.
- 14 November 2022
- Published by Springer Nature in Molecular Biology Reports
- Vol. 50 (1) , 731-737
Open AccessTRIM11, a new target of p53, facilitates the migration and invasion of nasopharyngeal carcinoma cells
Background: Although tripartite motif-containing protein 11 (TRIM11) is known to be associated with a variety of cancers, its role in nasopharyngeal carcinoma (NPC) is unclear. Methods and results: To investigate the role of TRIM11 in NPC, TRIM11 was stably overexpressed in 6–10B and CNE2 cells with lentiviral vectors and knocked down in S18 and 5–8F cells using the CRISPR/Cas9 system. Transwell assays and wound-healing assays revealed that TRIM11 facilitated the migration and invasion of NPC cells. Mechanistically, we found that p53 inhibits TRIM11 expression by binding to its promoter. Conclusions: TRIM11 may serve as a potential diagnostic marker for NPC and has a certain therapeutic value.
- 2 September 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (10) , 1-12
Feasibility analyses of virtual models and 3D printing for surgical simulation of the double-outlet right ventricle
Accurate diagnosis and surgical selection of the double-outlet right ventricle (DORV) is both critical and difficult. Virtual models and three-dimensional (3D) printing have been used to provide morphological copies to doctors as reference. However, the existing methods have shortcomings in visualization of the surgical results, optimal surgical design, and accurate surgical scheme measurements. To overcome this problem, we performed surgical predictions by designing the intraventricular baffle and ventricular septal defect patch to evaluate surgical options and using 3D printing to guide the trimming of the baffle or patch. A complete set of processes including scanning, modeling, designing, 3D printing, and guiding the trimming of the baffle for the diagnosis and surgical planning of DORV was established. Six cases were used to evaluate the feasibility of this method. The average rate of misdiagnosis of the six cases by computed tomography and echocardiography was 42.5%, which was reduced to 4.6% when the diagnosis was established using the virtual models and 3D printing as auxiliary tools. The approach effectively improved diagnostic accuracy, guided the operation, and simplified the process of patch trimming. The proposed method can thus be used for improving the surgical simulation and guiding of the DORV surgery. Graphical abstract
- 2 September 2022
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 60 (10) , 1-12
Feasibility analyses of virtual models and 3D printing for surgical simulation of the double-outlet right ventricle
Accurate diagnosis and surgical selection of the double-outlet right ventricle (DORV) is both critical and difficult. Virtual models and three-dimensional (3D) printing have been used to provide morphological copies to doctors as reference. However, the existing methods have shortcomings in visualization of the surgical results, optimal surgical design, and accurate surgical scheme measurements. To overcome this problem, we performed surgical predictions by designing the intraventricular baffle and ventricular septal defect patch to evaluate surgical options and using 3D printing to guide the trimming of the baffle or patch. A complete set of processes including scanning, modeling, designing, 3D printing, and guiding the trimming of the baffle for the diagnosis and surgical planning of DORV was established. Six cases were used to evaluate the feasibility of this method. The average rate of misdiagnosis of the six cases by computed tomography and echocardiography was 42.5%, which was reduced to 4.6% when the diagnosis was established using the virtual models and 3D printing as auxiliary tools. The approach effectively improved diagnostic accuracy, guided the operation, and simplified the process of patch trimming. The proposed method can thus be used for improving the surgical simulation and guiding of the DORV surgery. Graphical abstract
- Open Access
- 9 June 2022
- Published by Springer Nature in Research Square
Causes and treatment strategies of unilateral leaflet shedding of bileaflet mechanical prosthetic heart valves after surgery
Objective: Unilateral leaflet shedding is a rare complication. This paper discusses the causes and treatment strategies of unilateral leaflet shedding of bileaflet mechanical prosthetic heart valves after surgery. Methods: This study was a retrospective study that included 1 case of unilateral leaflet shedding after mechanical valve replacement of the aortic valve in Fuwai Hospital in 2010 and 1 case of unilateral leaflet shedding after mechanical valve replacement of the mitral valve in the First People’s Hospital of Guangyuan in 2021. The new mechanical valves were replaced during subsequent surgeries. data were collected, and the patients were followed up for 10 years and 3 months after the operations, respectively. Results: The patient with an aortic valve replacement was a male; the patient with a mitral valve replacement was a female; and they had an average STS risk score of 3.9%. Both patients had severe regurgitation, and the results of the reoperations were satisfactory. After the operations, the echocardiograms showed that there was no regurgitation in either of the valve replacements. There were no changes in the ankle-brachial index (ABI) before and after the operation in either of the two patients, and no complications or deaths occurred during follow-up. Conclusion: The reason for the leaflet sheddings may be related to the valve design and the leaflet materia. If the detached leaflets are damaged and if the distal blood vessels are affected, simultaneous surgical treatment is required. Those patients whose vessels were not damaged by the valve lobe should be carefully monitored.
- 9 June 2022
- Published by Springer Nature in Research Square
Open AccessCauses and treatment strategies of unilateral leaflet shedding of bileaflet mechanical prosthetic heart valves after surgery
Objective: Unilateral leaflet shedding is a rare complication. This paper discusses the causes and treatment strategies of unilateral leaflet shedding of bileaflet mechanical prosthetic heart valves after surgery. Methods: This study was a retrospective study that included 1 case of unilateral leaflet shedding after mechanical valve replacement of the aortic valve in Fuwai Hospital in 2010 and 1 case of unilateral leaflet shedding after mechanical valve replacement of the mitral valve in the First People’s Hospital of Guangyuan in 2021. The new mechanical valves were replaced during subsequent surgeries. data were collected, and the patients were followed up for 10 years and 3 months after the operations, respectively. Results: The patient with an aortic valve replacement was a male; the patient with a mitral valve replacement was a female; and they had an average STS risk score of 3.9%. Both patients had severe regurgitation, and the results of the reoperations were satisfactory. After the operations, the echocardiograms showed that there was no regurgitation in either of the valve replacements. There were no changes in the ankle-brachial index (ABI) before and after the operation in either of the two patients, and no complications or deaths occurred during follow-up. Conclusion: The reason for the leaflet sheddings may be related to the valve design and the leaflet materia. If the detached leaflets are damaged and if the distal blood vessels are affected, simultaneous surgical treatment is required. Those patients whose vessels were not damaged by the valve lobe should be carefully monitored.
- Open Access
- 3 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Comparison of blood pool and myocardial 3D printing in the diagnosis of types of congenital heart disease
The study aimed to evaluate the effectiveness of blood pool and myocardial models made by stereolithography in the diagnosis of different types of congenital heart disease (CHD). Two modeling methods were applied in the diagnosis of 8 cases, and two control groups consisting of experts and students diagnosed the cases using echocardiography with computed tomography, blood pool models, and myocardial models. The importance, suitability, and simulation degree of different models were analyzed. The average diagnostic rate before and after 3D printing was used was 88.75% and 95.9% (P = 0.001) in the expert group and 60% and 91.6% (P = 0.000) in the student group, respectively. 3D printing was considered to be more important for the diagnosis of complex CHDs (very important; average, 87.8%) than simple CHDs (very important; average, 30.8%) (P = 0.000). Myocardial models were considered most realistic regarding the structure of the heart (average, 92.5%). In cases of congenital corrected transposition of great arteries, Williams syndrome, coronary artery fistula, tetralogy of Fallot, patent ductus arteriosus, and coarctation of the aorta, blood pool models were considered more effective (average, 92.1%), while in cases of double outlet right ventricle and ventricular septal defect, myocardial models were considered optimal (average, 80%).
- 3 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Open AccessComparison of blood pool and myocardial 3D printing in the diagnosis of types of congenital heart disease
The study aimed to evaluate the effectiveness of blood pool and myocardial models made by stereolithography in the diagnosis of different types of congenital heart disease (CHD). Two modeling methods were applied in the diagnosis of 8 cases, and two control groups consisting of experts and students diagnosed the cases using echocardiography with computed tomography, blood pool models, and myocardial models. The importance, suitability, and simulation degree of different models were analyzed. The average diagnostic rate before and after 3D printing was used was 88.75% and 95.9% (P = 0.001) in the expert group and 60% and 91.6% (P = 0.000) in the student group, respectively. 3D printing was considered to be more important for the diagnosis of complex CHDs (very important; average, 87.8%) than simple CHDs (very important; average, 30.8%) (P = 0.000). Myocardial models were considered most realistic regarding the structure of the heart (average, 92.5%). In cases of congenital corrected transposition of great arteries, Williams syndrome, coronary artery fistula, tetralogy of Fallot, patent ductus arteriosus, and coarctation of the aorta, blood pool models were considered more effective (average, 92.1%), while in cases of double outlet right ventricle and ventricular septal defect, myocardial models were considered optimal (average, 80%).
- Open Access
- 27 April 2022
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 22 (1) , 1-10
Effect of 3D-printed hearts used in left ventricular outflow tract obstruction: a multicenter study
Objective: The purpose of this research was to explore the application value of a three-dimensional (3D)-printed heart in surgery for left ventricular outflow tract (LVOT) obstruction. Methods: From August 2019 to October 2021, 46 patients with LVOT obstruction underwent surgical treatment at our institution. According to the treatment method, 22 and 24 patients were allocated to the experimental and control groups, respectively. In the experimental group, each patient’s 3D-printed heart model was used for simulated preoperative surgery, and then the Morrow operation was performed. In the control group, only the Morrow operation was performed, without simulated preoperative surgery using a 3D-printed heart model. The intraoperative and postoperative data of patients in the two groups were recorded, and the clinical data of patients were compared between the two groups. Results: The operation time, cardiopulmonary bypass time, intraoperative blood loss, hospitalization time, LVOT pressure difference (LVP), postoperative interventricular septal thickness (IST), aortic regurgitation (AR), systolic anterior motion (SAM), and postoperative left ventricular flow velocity (LVFV) were significantly lower in the experimental group than in the control group (P < 0.05). The inner diameter of the left ventricular outflow tract (IDLV) was larger in the experimental group than in the control group (P < 0.05). There was no significant difference in the postoperative ejection fraction, atrioventricular block rate or complication rate between the two groups (P > 0.05). Conclusion: A 3D-printed heart model for simulated surgery in vitro is conducive to formulating a more reasonable surgical plan and reducing the trauma and duration of surgery, thereby promoting the recovery and maintenance of the heart.
- 27 April 2022
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 22 (1) , 1-10
Open AccessEffect of 3D-printed hearts used in left ventricular outflow tract obstruction: a multicenter study
Objective: The purpose of this research was to explore the application value of a three-dimensional (3D)-printed heart in surgery for left ventricular outflow tract (LVOT) obstruction. Methods: From August 2019 to October 2021, 46 patients with LVOT obstruction underwent surgical treatment at our institution. According to the treatment method, 22 and 24 patients were allocated to the experimental and control groups, respectively. In the experimental group, each patient’s 3D-printed heart model was used for simulated preoperative surgery, and then the Morrow operation was performed. In the control group, only the Morrow operation was performed, without simulated preoperative surgery using a 3D-printed heart model. The intraoperative and postoperative data of patients in the two groups were recorded, and the clinical data of patients were compared between the two groups. Results: The operation time, cardiopulmonary bypass time, intraoperative blood loss, hospitalization time, LVOT pressure difference (LVP), postoperative interventricular septal thickness (IST), aortic regurgitation (AR), systolic anterior motion (SAM), and postoperative left ventricular flow velocity (LVFV) were significantly lower in the experimental group than in the control group (P < 0.05). The inner diameter of the left ventricular outflow tract (IDLV) was larger in the experimental group than in the control group (P < 0.05). There was no significant difference in the postoperative ejection fraction, atrioventricular block rate or complication rate between the two groups (P > 0.05). Conclusion: A 3D-printed heart model for simulated surgery in vitro is conducive to formulating a more reasonable surgical plan and reducing the trauma and duration of surgery, thereby promoting the recovery and maintenance of the heart.
- Open Access
- 7 January 2022
- Published by Springer Nature in Research Square
Effect of 3D-Printed Hearts Used in Left Ventricular Outflow Tract Obstruction: A Multicenter Study
Objective:The purpose of this research was to explore the application value of a three-dimensional (3D)-printed heart in the operation for left ventricular outflow tract (LVOT) obstruction. Methods: From August 2019 to October 2021, 46 patients with LVOT obstruction underwent surgical treatment at Peking University International Hospital, Southwest Medical University Affiliated Hospital of Traditional Chinese Medicine and Guangyuan First People's Hospital. According to the treatment method, 22 cases were allocated to the experimental group and 24 cases to the control group . The operation time, cardiopulmonary bypass time, intraoperative blood loss, hospitalization time, postoperative ejection fraction (EF), left ventricular flow velocity (LVFV), LVOT pressure difference (LVP), postoperative interventricular septal thickness (IST), inner diameter of the left ventricular outflow tract (IDLV), systolic anterior motion (SAM), atrioventricular block rate, aortic regurgitation (AR) rate and surgical complication rate of the two groups were compared. Results: The operation time, cardiopulmonary bypass time, intraoperative blood loss, hospitalization time, LVP, postoperative IST, AR, SAM, and postoperative LVFV of the experimental group were significantly lower than those of the control group (P < 0.05). The IDLV was larger than that of the control group (P < 0.05). There was no significant difference in the postoperative EF, atrioventricular block rate or complication rate between the two groups (P > 0.05). Conclusion: A 3D-printed heart model for in vitro simulation surgery is conducive to formulating a more reasonable surgical plan and reducing surgical trauma and operation time, thereby promoting the recovery and maintenance of the heart.
- 7 January 2022
- Published by Springer Nature in Research Square
Open AccessEffect of 3D-Printed Hearts Used in Left Ventricular Outflow Tract Obstruction: A Multicenter Study
Objective:The purpose of this research was to explore the application value of a three-dimensional (3D)-printed heart in the operation for left ventricular outflow tract (LVOT) obstruction. Methods: From August 2019 to October 2021, 46 patients with LVOT obstruction underwent surgical treatment at Peking University International Hospital, Southwest Medical University Affiliated Hospital of Traditional Chinese Medicine and Guangyuan First People's Hospital. According to the treatment method, 22 cases were allocated to the experimental group and 24 cases to the control group . The operation time, cardiopulmonary bypass time, intraoperative blood loss, hospitalization time, postoperative ejection fraction (EF), left ventricular flow velocity (LVFV), LVOT pressure difference (LVP), postoperative interventricular septal thickness (IST), inner diameter of the left ventricular outflow tract (IDLV), systolic anterior motion (SAM), atrioventricular block rate, aortic regurgitation (AR) rate and surgical complication rate of the two groups were compared. Results: The operation time, cardiopulmonary bypass time, intraoperative blood loss, hospitalization time, LVP, postoperative IST, AR, SAM, and postoperative LVFV of the experimental group were significantly lower than those of the control group (P < 0.05). The IDLV was larger than that of the control group (P < 0.05). There was no significant difference in the postoperative EF, atrioventricular block rate or complication rate between the two groups (P > 0.05). Conclusion: A 3D-printed heart model for in vitro simulation surgery is conducive to formulating a more reasonable surgical plan and reducing surgical trauma and operation time, thereby promoting the recovery and maintenance of the heart.
- 12 September 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (6) , 1385-1396
Feasibility Analysis of 3D Printing With Prenatal Ultrasound for the Diagnosis of Fetal Abnormalities
Objective: To assess the feasibility and accuracy of 3D printing with prenatal three‐dimensional ultrasound (3DUS) in the diagnosis of fetal abnormalities.Methods: Fetuses initially diagnosed with various abnormalities were included in this retrospective study. The fetuses were examined by 3DUS, modeled, and 3D printed, and the dimensional accuracy of the 3D prints was analyzed. The effectiveness, demand, necessity of 3D printing, and the diagnostic accuracy of different methods were analyzed based on questionnaire responses from 40 senior ultrasound doctors and 40 postgraduate students.Results: A total of 12 fetuses with cleft lip and palate, spinal, heart, or brain abnormalities were included for detailed assessment. All deviations (mean deviation: 0.1 mm) between the original images and the final 3D prints lay within the consistency boundary (−1.12, 1.31 mm) (P > .05). In the subsequent analyses, 90.8% of the doctors and 94.2% of the students strongly agreed that 3D printing could precisely represent and depict fetal abnormalities. The average misdiagnosis rate of the doctors decreased from 5% to 0.4% after the application of 3D printing combined with 3DUS in comparison with 3DUS alone, and the corresponding value for the students dropped from 17.9% to 5.2%.Conclusions: The errors in modeling and 3D printing based on 3DUS were within acceptable limits, and 3D printing improved the diagnosis of various fetal abnormalities.
- 12 September 2021
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 41 (6) , 1385-1396
Feasibility Analysis of 3D Printing With Prenatal Ultrasound for the Diagnosis of Fetal Abnormalities
Objective: To assess the feasibility and accuracy of 3D printing with prenatal three‐dimensional ultrasound (3DUS) in the diagnosis of fetal abnormalities.Methods: Fetuses initially diagnosed with various abnormalities were included in this retrospective study. The fetuses were examined by 3DUS, modeled, and 3D printed, and the dimensional accuracy of the 3D prints was analyzed. The effectiveness, demand, necessity of 3D printing, and the diagnostic accuracy of different methods were analyzed based on questionnaire responses from 40 senior ultrasound doctors and 40 postgraduate students.Results: A total of 12 fetuses with cleft lip and palate, spinal, heart, or brain abnormalities were included for detailed assessment. All deviations (mean deviation: 0.1 mm) between the original images and the final 3D prints lay within the consistency boundary (−1.12, 1.31 mm) (P > .05). In the subsequent analyses, 90.8% of the doctors and 94.2% of the students strongly agreed that 3D printing could precisely represent and depict fetal abnormalities. The average misdiagnosis rate of the doctors decreased from 5% to 0.4% after the application of 3D printing combined with 3DUS in comparison with 3DUS alone, and the corresponding value for the students dropped from 17.9% to 5.2%.Conclusions: The errors in modeling and 3D printing based on 3DUS were within acceptable limits, and 3D printing improved the diagnosis of various fetal abnormalities.
- 1 January 2021
- Vol. 13 (12) , 13394-13405
Cardiopulmonary haemodynamics after sieve-shaped atrial septal defect repair: a multicenter study
Objective: The study aimed to collect case data on cardiopulmonary bypass (CPB) sieve-shaped (S-S) and non-sieve-shaped (N-S-S) atrial septal defects (ASDs). Methods: We analysed and summarized the postoperative blood flow in the cardiopulmonary system. We retrospectively collected 86 patients who underwent CPB S-S and N-S-S ASD repair. The data collected included sex, age, CPB time, ASD area, percentage change in ventricular value (PVV) (preoperative/postoperative), left ventricular wall thickness, ejection fraction (EF) (preoperative/postoperative), fluid inflow value, pulmonary arterial pressure/pulmonary venous pressure, percentage change in total lung resistance (PTLR) (preoperative/postoperative) for statistical analysis and comparison. Results: There were 86 eligible patients in this study, 37 and 49 of whom had S-S and N-S-S ASDs, respectively. The PVV, PTLR, and pulmonary arterial pressure/pulmonary venous pressure (postoperative) were significantly different between the S-S and N-S-S groups. The mean PTLR in the S-S and N-S-S groups was 0.78 +/- 0.24 and 0.62 +/- 0.28, respectively. The mean PVV in the S-S group was 11.53 +/- 7.63, and that in the N-S-S group was 16.47 +/- 9.71. Multivariate analysis revealed PVV (OR, 0.143; 95% CI, 0.026-0.790; P=0.026), PTLR (OR, 0.156; 95% CI, 0.049-0.500; P=0.002), and pulmonary arterial pressure/pulmonary venous pressure (postoperative) (OR, 9.014; 95% CI, 2.480-32.755; P=0.001) as significant factors. The rate of pulmonary infection absence postoperatively in the S-S group was 76.52%, and that in the N-S-S group was 42.75%. Conclusion: Due to the differences in heart structure between the S-S and N-S-S groups, the haemodynamic index (PVV and PTLR, postoperative pulmonary arterial pressure/pulmonary venous pressure) changes after S-S ASD repair were less than those after N-S-S ASD repair, so the postoperative pulmonary infection rate was higher after N-S-S ASD repair. The pulmonary infection rate was low after S-S ASD repair, and drugs should be reasonably administered to prevent infection.T
- 1 January 2021
- Vol. 13 (12) , 13394-13405
Cardiopulmonary haemodynamics after sieve-shaped atrial septal defect repair: a multicenter study
Objective: The study aimed to collect case data on cardiopulmonary bypass (CPB) sieve-shaped (S-S) and non-sieve-shaped (N-S-S) atrial septal defects (ASDs). Methods: We analysed and summarized the postoperative blood flow in the cardiopulmonary system. We retrospectively collected 86 patients who underwent CPB S-S and N-S-S ASD repair. The data collected included sex, age, CPB time, ASD area, percentage change in ventricular value (PVV) (preoperative/postoperative), left ventricular wall thickness, ejection fraction (EF) (preoperative/postoperative), fluid inflow value, pulmonary arterial pressure/pulmonary venous pressure, percentage change in total lung resistance (PTLR) (preoperative/postoperative) for statistical analysis and comparison. Results: There were 86 eligible patients in this study, 37 and 49 of whom had S-S and N-S-S ASDs, respectively. The PVV, PTLR, and pulmonary arterial pressure/pulmonary venous pressure (postoperative) were significantly different between the S-S and N-S-S groups. The mean PTLR in the S-S and N-S-S groups was 0.78 +/- 0.24 and 0.62 +/- 0.28, respectively. The mean PVV in the S-S group was 11.53 +/- 7.63, and that in the N-S-S group was 16.47 +/- 9.71. Multivariate analysis revealed PVV (OR, 0.143; 95% CI, 0.026-0.790; P=0.026), PTLR (OR, 0.156; 95% CI, 0.049-0.500; P=0.002), and pulmonary arterial pressure/pulmonary venous pressure (postoperative) (OR, 9.014; 95% CI, 2.480-32.755; P=0.001) as significant factors. The rate of pulmonary infection absence postoperatively in the S-S group was 76.52%, and that in the N-S-S group was 42.75%. Conclusion: Due to the differences in heart structure between the S-S and N-S-S groups, the haemodynamic index (PVV and PTLR, postoperative pulmonary arterial pressure/pulmonary venous pressure) changes after S-S ASD repair were less than those after N-S-S ASD repair, so the postoperative pulmonary infection rate was higher after N-S-S ASD repair. The pulmonary infection rate was low after S-S ASD repair, and drugs should be reasonably administered to prevent infection.T