Liang-Der Jou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Liang-Der Jou has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- David Saloner
Department of Radiology and Biomedical Imaging (D.M., D.S.), University of California, San Francisco, San Francisco, CA, United States
1 shared publication Gavin Britz
Department of Neurosurgery, Houston Methodist Hospital
1 shared publication- Gavin Wayne Britz
Department of Neurosurgery, Houston Methodist Hospital, Houston, Texas, USA
1 shared publication Gouthami Chintalapani
Siemens Medical Solutions Hoffman Estates, Illinois, USA
1 shared publicationMichel E Mawad
Department of Radiology, Baylor College of Medicine, Houston, Texas, USA
1 shared publicationMichel E. Mawad
Department of Radiology, Baylor College of Medicine, 1 Baylor Plaza, MS-360, Houston, TX 77030, United States
1 shared publication
Latest Publications
- 2 March 2017
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 23 (3) , 260-266
In vitro digital subtraction angiographic evaluation of flow diverters in a patient-specific aneurysm
Background: The importance of both porosity and pore density of a flow diverter is well recognized in treatment of intracranial aneurysms; however, understanding of the effect of individual wire (wire number and size) is critical in improving device design and use. Methods: A total of 10 multi-layered flow diverters with different wire numbers (32, 48, 56, and 72) and sizes (30, 35, and 40 µm) were implanted into identical patient-specific middle cerebral artery aneurysm models. Digital subtraction angiography was acquired at 30 f/s and X-ray signals at three selected regions of interest were compared to determine the amount of intra-aneurysmal flow. Results: Flow reduction ranged from 19% for a high porosity (82%) and low pore density (5 pores/mm 2 ) to nearly 80% for a low porosity (49%) and high pore density (36 pores/mm 2 ). An increase in the wire number from 32 to 72 lowers intra-aneurysmal flow and redirects the flow jet; however, the effect of wire size is not observed. Conclusions: In our in vitro angiographic study, flow jet is influenced by the wire number in a device qualitatively; quantitatively, intra-aneurysmal flow is affected by both the porosity and pore density. A 2.5 mm device performs better in flow diversion of a middle cerebral artery (MCA) aneurysm than a 3 mm device with the same wire size and wire number, but thicker wires do not lead to better flow diversion.
- 2 March 2017
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 23 (3) , 260-266
In vitro digital subtraction angiographic evaluation of flow diverters in a patient-specific aneurysm
Background: The importance of both porosity and pore density of a flow diverter is well recognized in treatment of intracranial aneurysms; however, understanding of the effect of individual wire (wire number and size) is critical in improving device design and use. Methods: A total of 10 multi-layered flow diverters with different wire numbers (32, 48, 56, and 72) and sizes (30, 35, and 40 µm) were implanted into identical patient-specific middle cerebral artery aneurysm models. Digital subtraction angiography was acquired at 30 f/s and X-ray signals at three selected regions of interest were compared to determine the amount of intra-aneurysmal flow. Results: Flow reduction ranged from 19% for a high porosity (82%) and low pore density (5 pores/mm 2 ) to nearly 80% for a low porosity (49%) and high pore density (36 pores/mm 2 ). An increase in the wire number from 32 to 72 lowers intra-aneurysmal flow and redirects the flow jet; however, the effect of wire size is not observed. Conclusions: In our in vitro angiographic study, flow jet is influenced by the wire number in a device qualitatively; quantitatively, intra-aneurysmal flow is affected by both the porosity and pore density. A 2.5 mm device performs better in flow diversion of a middle cerebral artery (MCA) aneurysm than a 3 mm device with the same wire size and wire number, but thicker wires do not lead to better flow diversion.
- Open Access
- 12 July 2016
- Published by Springer Nature in Cureus
- Vol. 8 (7) , e683
Correlation Between Aneurysm Size and Hemodynamics in One Individual with Multiple Small Intracranial Aneurysms
Objective A large number of cases are needed in the patient-specific modeling of intracranial aneurysms to establish the statistical significance due to individual variation of risk factors that are difficult to account for. However, these risk factors are critical in hemorrhage risk as demonstrated in large clinical studies. Rupture risks for aneurysms in an individual are easier to compare because these aneurysms are under the same physiological environment, and their only differences are the local hemodynamic factors associated with their anatomic locations. Methods Eight small aneurysms (< 7 mm) from one individual were analyzed using patient-specific hemodynamic modeling. Four scenarios with different perfusion assumptions were performed to account for the flow rate at two smaller communicating arteries. Wall shear stresses (WSS) at these aneurysms were compared to determine their relationship with the aneurysm size. Results Each of the three largest aneurysms is either the most proximal or distal aneurysm in a given artery so that blood pressure does not have a direct influence on aneurysm size. No wall shear stress-derived hemodynamic variables are found to be related to aneurysm size. Discussion A study of multiple aneurysms from one individual offers a unique opportunity to examine various hemodynamic factors without selection biases. Aneurysms greater than 4 mm (Group 1) have a higher product of maximum WSS and area of low WSS; aneurysms smaller than 4 mm (Group 2) have a lower product of maximum WSS and area of low WSS. In addition, aneurysm size is linearly correlated with the flow rate at the parent artery in each group.
- 12 July 2016
- Published by Springer Nature in Cureus
- Vol. 8 (7) , e683
Open AccessCorrelation Between Aneurysm Size and Hemodynamics in One Individual with Multiple Small Intracranial Aneurysms
Objective A large number of cases are needed in the patient-specific modeling of intracranial aneurysms to establish the statistical significance due to individual variation of risk factors that are difficult to account for. However, these risk factors are critical in hemorrhage risk as demonstrated in large clinical studies. Rupture risks for aneurysms in an individual are easier to compare because these aneurysms are under the same physiological environment, and their only differences are the local hemodynamic factors associated with their anatomic locations. Methods Eight small aneurysms (< 7 mm) from one individual were analyzed using patient-specific hemodynamic modeling. Four scenarios with different perfusion assumptions were performed to account for the flow rate at two smaller communicating arteries. Wall shear stresses (WSS) at these aneurysms were compared to determine their relationship with the aneurysm size. Results Each of the three largest aneurysms is either the most proximal or distal aneurysm in a given artery so that blood pressure does not have a direct influence on aneurysm size. No wall shear stress-derived hemodynamic variables are found to be related to aneurysm size. Discussion A study of multiple aneurysms from one individual offers a unique opportunity to examine various hemodynamic factors without selection biases. Aneurysms greater than 4 mm (Group 1) have a higher product of maximum WSS and area of low WSS; aneurysms smaller than 4 mm (Group 2) have a lower product of maximum WSS and area of low WSS. In addition, aneurysm size is linearly correlated with the flow rate at the parent artery in each group.
- 1 April 2016
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 6 (2) , 134-143
In vitro investigation of contrast flow jet timing in patient-specific intracranial aneurysms
Background: The direction and magnitude of intra-aneurysmal flow jet are significant risk factors of subarachnoid hemorrhage, and the change of flow jet during an endovascular procedure has been used for prediction of aneurysm occlusion or whether an additional flow diverter (FD) is warranted. However, evaluation of flow jets is often unreliable due to a large variation of flow jet on the digital subtraction angiograms, and this flow pattern variation may result in incorrect clinical diagnosis Therefore, factors contributing to the variation in flow jet are examined at an in vitro setting, and the findings can help us to understand the nature of flow jet and devise a better plan to quantify the aneurysmal hemodynamics accurately. Methods: Intra-aneurysmal flows in three patient-specific aneurysms between 11 and 25 mm were investigated in vitro, and a FD was deployed in each aneurysm model. X-ray imaging of these models were performed at injection rates between 0.2 and 2 mL/s. Pulsatile blood pump and aneurysm model were imaged together to determine the timing of flow jet. Results: The contrast bolus arrives at the aneurysm early at high contrast injection rates. The flow patterns with slow injection rates exhibit strong inertia that is associated with the systole flow. Flow jets arrive at the aneurysms at the peak systole when the bolus is injected at 0.2 mL/s. The contrast-to-signal ratio is the highest at the injection rate of 0.5 mL/s. Effect of flow diversion can only be assessed at an injection rate greater than 0.5 mL/s. Conclusions: Intra-aneurysmal flow jet is highly dependent on the injection rate of the contrast agent. For the internal carotid artery (ICA) aneurysms, the systolic flows can be visualized at slow injection rates (1 mL/s). Dependence of flow jet on the contrast injection rate has serious clinical implications and needs to be considered during diagnostic procedures; a protocol with a consistent injection rate is highly recommended.
- 1 April 2016
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 6 (2) , 134-143
In vitro investigation of contrast flow jet timing in patient-specific intracranial aneurysms
Background: The direction and magnitude of intra-aneurysmal flow jet are significant risk factors of subarachnoid hemorrhage, and the change of flow jet during an endovascular procedure has been used for prediction of aneurysm occlusion or whether an additional flow diverter (FD) is warranted. However, evaluation of flow jets is often unreliable due to a large variation of flow jet on the digital subtraction angiograms, and this flow pattern variation may result in incorrect clinical diagnosis Therefore, factors contributing to the variation in flow jet are examined at an in vitro setting, and the findings can help us to understand the nature of flow jet and devise a better plan to quantify the aneurysmal hemodynamics accurately. Methods: Intra-aneurysmal flows in three patient-specific aneurysms between 11 and 25 mm were investigated in vitro, and a FD was deployed in each aneurysm model. X-ray imaging of these models were performed at injection rates between 0.2 and 2 mL/s. Pulsatile blood pump and aneurysm model were imaged together to determine the timing of flow jet. Results: The contrast bolus arrives at the aneurysm early at high contrast injection rates. The flow patterns with slow injection rates exhibit strong inertia that is associated with the systole flow. Flow jets arrive at the aneurysms at the peak systole when the bolus is injected at 0.2 mL/s. The contrast-to-signal ratio is the highest at the injection rate of 0.5 mL/s. Effect of flow diversion can only be assessed at an injection rate greater than 0.5 mL/s. Conclusions: Intra-aneurysmal flow jet is highly dependent on the injection rate of the contrast agent. For the internal carotid artery (ICA) aneurysms, the systolic flows can be visualized at slow injection rates (1 mL/s). Dependence of flow jet on the contrast injection rate has serious clinical implications and needs to be considered during diagnostic procedures; a protocol with a consistent injection rate is highly recommended.
- Open Access
- 30 November 2015
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 22 (1) , 42-48
Metal coverage ratio of pipeline embolization device for treatment of unruptured aneurysms: Reality check
The metal coverage ratio (MCR) of a flow diverter influences the intra-aneurysmal hemodynamics; a high MCR will occlude an aneurysm early, while a low MCR may delay aneurysm occlusion. The true MCR of a pipeline embolization device (PED) could be lower due to oversize, device deformation, or aneurysm location. In this study deviation of the true MCR from the nominal MCR is assessed and whether their difference affects aneurysm occlusion rate is determined. A total of 40 consecutive patients, each of them treated by one PED for their aneurysms at the internal carotid artery (ICA), were retrospectively analyzed. The DynaCT images of these deployed PEDs were used to determine their true dimensions and estimate three MCRs (local, mean, and nominal). These data were compared in two groups of patients who had different aneurysm outcomes at six months. The difference in the local MCR between two groups is small, but statistically significant (24.5% vs 21.6%, p = 05). The local MCR is consistently lower than the nominal MCRs (23.2% vs 30.2%, p < 0.001); however, the difference between the mean and local MCRs is small (23.9% vs 23.2%). An expectation that a PED can achieve a MCR of 30% may not be reasonable. Device oversize and deformation during deployment lower the local MCR by 5–7%. A lowered MCR affects the aneurysm occlusion rate at six months.
- 30 November 2015
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 22 (1) , 42-48
Open AccessMetal coverage ratio of pipeline embolization device for treatment of unruptured aneurysms: Reality check
The metal coverage ratio (MCR) of a flow diverter influences the intra-aneurysmal hemodynamics; a high MCR will occlude an aneurysm early, while a low MCR may delay aneurysm occlusion. The true MCR of a pipeline embolization device (PED) could be lower due to oversize, device deformation, or aneurysm location. In this study deviation of the true MCR from the nominal MCR is assessed and whether their difference affects aneurysm occlusion rate is determined. A total of 40 consecutive patients, each of them treated by one PED for their aneurysms at the internal carotid artery (ICA), were retrospectively analyzed. The DynaCT images of these deployed PEDs were used to determine their true dimensions and estimate three MCRs (local, mean, and nominal). These data were compared in two groups of patients who had different aneurysm outcomes at six months. The difference in the local MCR between two groups is small, but statistically significant (24.5% vs 21.6%, p = 05). The local MCR is consistently lower than the nominal MCRs (23.2% vs 30.2%, p < 0.001); however, the difference between the mean and local MCRs is small (23.9% vs 23.2%). An expectation that a PED can achieve a MCR of 30% may not be reasonable. Device oversize and deformation during deployment lower the local MCR by 5–7%. A lowered MCR affects the aneurysm occlusion rate at six months.
- 1 June 2011
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 33 (5) , 573-580
Hemodynamic effect of Neuroform stent on intimal hyperplasia and thrombus formation in a carotid aneurysm
Stents play an important role in management of cerebral aneurysms. A stent reconstructs the parent artery, assists coil embolization, and decreases flow activity within an aneurysm. However, an in-stent stenosis often occurs within the stented artery and compromises the circulation at the parent artery. Hemodynamic basis of re-stenoses from aneurysm stenting is not fully understood. An 8mm cavernous carotid aneurysm with a wide neck was treated by a Neuroform stent first and by coils five weeks later. A comparison of the difference in morphology during this five-week period reveals the presence of intimal hyperplasia in the internal carotid artery, 1.3mm thick at the proximal end and 1mm at the distal end of the stent, and 1mm thick thrombus at the postero-inferior side of the aneurysm. Computational fluid dynamic analyses show that the site of intimal hyperplasia is exposed to low wall shear with high oscillatory shear index (OSI), and the location of thrombus is subject to high OSI. Intimal hyperplasia and thrombus occur at comparable rates, but at different hemodynamic conditions; however, both prefer regions with high OSIs.
- 1 June 2011
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 33 (5) , 573-580
Hemodynamic effect of Neuroform stent on intimal hyperplasia and thrombus formation in a carotid aneurysm
Stents play an important role in management of cerebral aneurysms. A stent reconstructs the parent artery, assists coil embolization, and decreases flow activity within an aneurysm. However, an in-stent stenosis often occurs within the stented artery and compromises the circulation at the parent artery. Hemodynamic basis of re-stenoses from aneurysm stenting is not fully understood. An 8mm cavernous carotid aneurysm with a wide neck was treated by a Neuroform stent first and by coils five weeks later. A comparison of the difference in morphology during this five-week period reveals the presence of intimal hyperplasia in the internal carotid artery, 1.3mm thick at the proximal end and 1mm at the distal end of the stent, and 1mm thick thrombus at the postero-inferior side of the aneurysm. Computational fluid dynamic analyses show that the site of intimal hyperplasia is exposed to low wall shear with high oscillatory shear index (OSI), and the location of thrombus is subject to high OSI. Intimal hyperplasia and thrombus occur at comparable rates, but at different hemodynamic conditions; however, both prefer regions with high OSIs.
- 25 April 2004
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 16 (02) , 43-48
DETERMINING INTRA-ANEURYSMAL FLOW FOR COILED CEREBRAL ANEURYSMS WITH DIGITAL FLUOROSCOPY
Background and Purpose. Aneurysm geometry often dictates the success of coil embolization. A strong hemodynamic force or high intra-aneurysmal flow may indicate a high probability of recanalization. It is necessary to develop a tool that can predict and estimate the level of hemodynamic forces that coils are subject to during the procedure. Methods. A compartment model is developed to estimate the intra-aneurysmal flow after coil embolization from digital fluoroscopy. The model is based on the measured signal intensity curves for the aneurysm and adjacent artery and derives the amount of intra-aneurysmal flow reduction. A clinical case of a carotid aneurysm was used for demonstration of its ability. Results. Intra-aneurysmal flow was reduced by 70% after coil embolization, and the estimated porosity was 60%. Flow reduction was confirmed by computational fluid dynamics simulations that modeled the coiled aneurysm as a porous medium. Conclusion. Intra-aneurysmal flow reduction may be used to predict the outcome of coil embolization or possible aneurysm recurrence. A sustained high intra-aneurysmal flow prohibits complete embolization and allows recanalization of the aneurysm. The compartment model provides a reasonable estimate of intra-aneurysmal flow and hemodynamic forces on the coils.
- 25 April 2004
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 16 (02) , 43-48
DETERMINING INTRA-ANEURYSMAL FLOW FOR COILED CEREBRAL ANEURYSMS WITH DIGITAL FLUOROSCOPY
Background and Purpose. Aneurysm geometry often dictates the success of coil embolization. A strong hemodynamic force or high intra-aneurysmal flow may indicate a high probability of recanalization. It is necessary to develop a tool that can predict and estimate the level of hemodynamic forces that coils are subject to during the procedure. Methods. A compartment model is developed to estimate the intra-aneurysmal flow after coil embolization from digital fluoroscopy. The model is based on the measured signal intensity curves for the aneurysm and adjacent artery and derives the amount of intra-aneurysmal flow reduction. A clinical case of a carotid aneurysm was used for demonstration of its ability. Results. Intra-aneurysmal flow was reduced by 70% after coil embolization, and the estimated porosity was 60%. Flow reduction was confirmed by computational fluid dynamics simulations that modeled the coiled aneurysm as a porous medium. Conclusion. Intra-aneurysmal flow reduction may be used to predict the outcome of coil embolization or possible aneurysm recurrence. A sustained high intra-aneurysmal flow prohibits complete embolization and allows recanalization of the aneurysm. The compartment model provides a reasonable estimate of intra-aneurysmal flow and hemodynamic forces on the coils.