Nimrod Snir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nimrod Snir has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Itay Ashkenazi
Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
4 shared publications - Yaniv Warschawski
Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
4 shared publications - Nissan Amzallag
Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
3 shared publications - Aviram Gold
Division of Orthopedics, Tel Aviv Sourasky Medical Center, 6 Weizman Street, Tel-Aviv 6423906, Israel
2 shared publications Ely L. Steinberg
Tel Aviv University
2 shared publications- Nadav Graif
Department of Paediatric Orthopaedics, Tel Aviv Sourasky University Medical Center (Ichilov), 6 Weizmann Street, Tel Aviv, 6423906, Israel; Gray Faculty of Medical and Health Sciences, Tel Aviv University, Tel Aviv, Israel
2 shared publications
Latest Publications
- 4 September 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-7
Effect of intraoperative tranexamic acid on blood loss and outcomes in intertrochanteric fractures: a retrospective study of 1728 patients
Purpose To evaluate the effect of intraoperative tranexamic acid (TXA) on perioperative blood loss, transfusion requirements, and clinical outcomes in patients undergoing proximal femoral nailing (PFN) for intertrochanteric fractures. Methods A retrospective cohort study of 1,728 patients who underwent PFN fixation for intertrochanteric fractures between 2017 and 2024. Perioperative hemoglobin (Hb) dynamics, transfusion requirements, and clinical outcomes were compared between patients receiving 1–1.5 g intravenous TXA (n = 1,446) and controls (n = 282). Results The TXA group demonstrated reduced perioperative Hb decline (2.15 ± 1.40 vs 2.76 ± 1.57 g/dL, p < 0.001) and lower rates of Hb drop > 2 g/dL (47.9% vs 63.5%, OR 0.53, p < 0.001). TXA administration was associated with decreased transfusion requirements (7.1% vs 11.0%, p = 0.021). Multivariate analysis confirmed TXA as an independent protective factor against blood loss. Mortality rates showed no significant difference between groups. Conclusion Intraoperative TXA during PFN fixation was associated with reduced perioperative blood loss and transfusion requirements. These findings support TXA as an effective blood conservation strategy in elderly patients with intertrochanteric fractures.
- 4 September 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-7
Effect of intraoperative tranexamic acid on blood loss and outcomes in intertrochanteric fractures: a retrospective study of 1728 patients
Purpose To evaluate the effect of intraoperative tranexamic acid (TXA) on perioperative blood loss, transfusion requirements, and clinical outcomes in patients undergoing proximal femoral nailing (PFN) for intertrochanteric fractures. Methods A retrospective cohort study of 1,728 patients who underwent PFN fixation for intertrochanteric fractures between 2017 and 2024. Perioperative hemoglobin (Hb) dynamics, transfusion requirements, and clinical outcomes were compared between patients receiving 1–1.5 g intravenous TXA (n = 1,446) and controls (n = 282). Results The TXA group demonstrated reduced perioperative Hb decline (2.15 ± 1.40 vs 2.76 ± 1.57 g/dL, p < 0.001) and lower rates of Hb drop > 2 g/dL (47.9% vs 63.5%, OR 0.53, p < 0.001). TXA administration was associated with decreased transfusion requirements (7.1% vs 11.0%, p = 0.021). Multivariate analysis confirmed TXA as an independent protective factor against blood loss. Mortality rates showed no significant difference between groups. Conclusion Intraoperative TXA during PFN fixation was associated with reduced perioperative blood loss and transfusion requirements. These findings support TXA as an effective blood conservation strategy in elderly patients with intertrochanteric fractures.
- 24 April 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-7
Canal fill and radiographic comparison analysis of novel fully hydroxyapatite coated, variable triple-tapered geometry stems: one-year follow-up after direct anterior approach total hip arthroplasty
Background Optimal femoral stem alignment and femoral canal fill have been associated with improved osteointegration in patients undergoing cementless total hip arthroplasty (THA). Direct anterior approach (DAA) has become more popular among new surgeons, and the ability to achieve appropriate stem alignment and canal fill due to limited surgical exposure may pose added risks. To mitigate these concerns, several modern tissue sparing stem designs have been designed. This study aimed to compare implant canal fill and alignment between two of the leading DAA-friendly femoral stems available. Methods This was a multi-center, retrospective study of patients who underwent DAA THA with either A (n = 149) or B stem (n = 85) between 2021 and 2023 and had a minimum one-year follow-up. Radiographic measures of proximal femoral morphology, including canal calcar ratio (CCR), Morphological Cortical Index (MCI), and Dorr Class (based on the CCR), as well as postoperative measures including femoral canal fill ratio (CFR), signs of osteointegration and stem alignment were analyzed and compared between stem types. Results Proximal femoral morphology was similar between groups, as suggested by the CCR (p = 0.600), MCI (p = 0.489) and Dorr class distribution (p = 0.516). Patients who received stem A had improved CFR at the level of the lesser trochanter compared to patients who received stem B (0.73 vs. 0.70, respectively; p = 0.042), with similar CFR at the tip of the stem (0.76 vs. 0.77, p = 0.562). Similarly, there was a trend towards improving stem alignment for stem A patients (2.16o vs. 2.47o, p = 0.082). Spot weld formation was significantly higher in stem A group (59.7% vs. 37.6%, P = 0.001). Conclusion For patients with similar femoral morphology undergoing DAA THA, the stem A group demonstrated superior anatomical fit in the metaphyseal region, as evidenced by CFR, spot weld formation and implant positioning. Further longer follow up research is needed to elucidate these findings and their correlation to clinical outcomes.
- 24 April 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-7
Canal fill and radiographic comparison analysis of novel fully hydroxyapatite coated, variable triple-tapered geometry stems: one-year follow-up after direct anterior approach total hip arthroplasty
Background Optimal femoral stem alignment and femoral canal fill have been associated with improved osteointegration in patients undergoing cementless total hip arthroplasty (THA). Direct anterior approach (DAA) has become more popular among new surgeons, and the ability to achieve appropriate stem alignment and canal fill due to limited surgical exposure may pose added risks. To mitigate these concerns, several modern tissue sparing stem designs have been designed. This study aimed to compare implant canal fill and alignment between two of the leading DAA-friendly femoral stems available. Methods This was a multi-center, retrospective study of patients who underwent DAA THA with either A (n = 149) or B stem (n = 85) between 2021 and 2023 and had a minimum one-year follow-up. Radiographic measures of proximal femoral morphology, including canal calcar ratio (CCR), Morphological Cortical Index (MCI), and Dorr Class (based on the CCR), as well as postoperative measures including femoral canal fill ratio (CFR), signs of osteointegration and stem alignment were analyzed and compared between stem types. Results Proximal femoral morphology was similar between groups, as suggested by the CCR (p = 0.600), MCI (p = 0.489) and Dorr class distribution (p = 0.516). Patients who received stem A had improved CFR at the level of the lesser trochanter compared to patients who received stem B (0.73 vs. 0.70, respectively; p = 0.042), with similar CFR at the tip of the stem (0.76 vs. 0.77, p = 0.562). Similarly, there was a trend towards improving stem alignment for stem A patients (2.16o vs. 2.47o, p = 0.082). Spot weld formation was significantly higher in stem A group (59.7% vs. 37.6%, P = 0.001). Conclusion For patients with similar femoral morphology undergoing DAA THA, the stem A group demonstrated superior anatomical fit in the metaphyseal region, as evidenced by CFR, spot weld formation and implant positioning. Further longer follow up research is needed to elucidate these findings and their correlation to clinical outcomes.
- 15 February 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Increased rates of periprosthetic joint infection following hip hemiarthroplasty with clindamycin prophylaxis compared to cefazolin
Purpose To compare the efficacy of clindamycin versus cefazolin in preventing periprosthetic joint infection (PJI) in patients undergoing hip hemiarthroplasty (HA) for femoral neck fractures. Methods This retrospective cohort study included 1,139 patients aged ≥ 65 years who underwent HA for femoral neck fractures between January 2017 and October 2023. Patients received either Cefazolin + Gentamicin (n = 1001) or Clindamycin + Gentamicin (n = 138). Propensity score matching was performed at a 6:1 ratio, resulting in 828 patients in the cefazolin group and 138 in the clindamycin group. PJI rates, causative organisms, and mortality were compared. Multivariate logistic regression adjusted for potential confounders. Results The PJI rate was significantly higher in the clindamycin group compared to the cefazolin group (7.2% vs. 3.5%, p = 0.042). Multivariate analysis confirmed that clindamycin prophylaxis was independently associated with increased PJI risk (adjusted OR = 2.41, 95% CI: 1.16–4.99, p = 0.018). Other independent risk factors for PJI included age (adjusted OR = 1.03 per year, 95% CI: 1.01–1.05, p = 0.045), diabetes mellitus (adjusted OR = 1.76, 95% CI: 1.10–2.81, p = 0.018), and surgery duration (adjusted OR = 1.07 per minute, 95% CI: 1.01–1.16, p = 0.035). Staphylococcus aureus was the most common pathogen, with no significant differences in bacterial distribution between the groups. No significant differences were found in 30-day or 1-year mortality rates. Conclusion Clindamycin prophylaxis in hip hemiarthroplasty for femoral neck fractures is associated with a significantly higher risk of PJI compared to cefazolin. These findings support the preferential use of cefazolin in patients without contraindications and demonstrate the critical need for accurate assessment of reported beta-lactam allergies. Results suggest potential benefit from pre-operative allergy evaluation when feasible, as alternative prophylaxis choices may carry increased infection risk. Further research is needed to explore alternative prophylactic strategies for patients with beta-lactam allergies.
- 15 February 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 1-8
Increased rates of periprosthetic joint infection following hip hemiarthroplasty with clindamycin prophylaxis compared to cefazolin
Purpose To compare the efficacy of clindamycin versus cefazolin in preventing periprosthetic joint infection (PJI) in patients undergoing hip hemiarthroplasty (HA) for femoral neck fractures. Methods This retrospective cohort study included 1,139 patients aged ≥ 65 years who underwent HA for femoral neck fractures between January 2017 and October 2023. Patients received either Cefazolin + Gentamicin (n = 1001) or Clindamycin + Gentamicin (n = 138). Propensity score matching was performed at a 6:1 ratio, resulting in 828 patients in the cefazolin group and 138 in the clindamycin group. PJI rates, causative organisms, and mortality were compared. Multivariate logistic regression adjusted for potential confounders. Results The PJI rate was significantly higher in the clindamycin group compared to the cefazolin group (7.2% vs. 3.5%, p = 0.042). Multivariate analysis confirmed that clindamycin prophylaxis was independently associated with increased PJI risk (adjusted OR = 2.41, 95% CI: 1.16–4.99, p = 0.018). Other independent risk factors for PJI included age (adjusted OR = 1.03 per year, 95% CI: 1.01–1.05, p = 0.045), diabetes mellitus (adjusted OR = 1.76, 95% CI: 1.10–2.81, p = 0.018), and surgery duration (adjusted OR = 1.07 per minute, 95% CI: 1.01–1.16, p = 0.035). Staphylococcus aureus was the most common pathogen, with no significant differences in bacterial distribution between the groups. No significant differences were found in 30-day or 1-year mortality rates. Conclusion Clindamycin prophylaxis in hip hemiarthroplasty for femoral neck fractures is associated with a significantly higher risk of PJI compared to cefazolin. These findings support the preferential use of cefazolin in patients without contraindications and demonstrate the critical need for accurate assessment of reported beta-lactam allergies. Results suggest potential benefit from pre-operative allergy evaluation when feasible, as alternative prophylaxis choices may carry increased infection risk. Further research is needed to explore alternative prophylactic strategies for patients with beta-lactam allergies.
- Open Access
Accurate Restoration of the Center of Rotation of the Hip Joint Based on Preoperative Planning Is Not Associated with Improved Clinical Outcomes
One of the main objectives of total hip arthroplasty (THA) is to recreate the center of rotation (COR). Accurate reconstruction of the COR is suggested to be within 5 mm of its anatomical location. The goal of our study was to assess whether accurate reconstruction of the COR, based on preoperative planning, is associated with improved clinical outcomes. The study population consisted of patients who underwent THA at our institution between August 2018 and May 2020. All patients underwent preoperative digital templating. The position of the predicted COR was compared to its actual postoperative position. Patients were subsequently stratified into two subgroups based on the difference between the distance of the predicted COR and the reconstructed COR, over or under 5 mm. A 12-Item Short Form Health Survey (SF-12) and visual analogue scale (VAS) were taken for each patient. 90 patients were included in this study. 60 patients (66%) had their COR reconstructed within 5 mm of preoperative planning, whereas for 30 patients (33%), reconstruction was outside of 5 mm of preoperative planning. Between the two cohorts, no significant difference existed in the physical component summary (PCS) (p = 0.33), the mental component summary (MCS = 0.16), or the visual analogue scale (VAS) (p = 0.12). The accurate restoration of COR based on preoperative planning is not associated with improved clinical outcomes. During postoperative evaluation, surgeons should feel confident if the COR is slightly greater than 5 mm of preoperative limitations.
Open AccessAccurate Restoration of the Center of Rotation of the Hip Joint Based on Preoperative Planning Is Not Associated with Improved Clinical Outcomes
One of the main objectives of total hip arthroplasty (THA) is to recreate the center of rotation (COR). Accurate reconstruction of the COR is suggested to be within 5 mm of its anatomical location. The goal of our study was to assess whether accurate reconstruction of the COR, based on preoperative planning, is associated with improved clinical outcomes. The study population consisted of patients who underwent THA at our institution between August 2018 and May 2020. All patients underwent preoperative digital templating. The position of the predicted COR was compared to its actual postoperative position. Patients were subsequently stratified into two subgroups based on the difference between the distance of the predicted COR and the reconstructed COR, over or under 5 mm. A 12-Item Short Form Health Survey (SF-12) and visual analogue scale (VAS) were taken for each patient. 90 patients were included in this study. 60 patients (66%) had their COR reconstructed within 5 mm of preoperative planning, whereas for 30 patients (33%), reconstruction was outside of 5 mm of preoperative planning. Between the two cohorts, no significant difference existed in the physical component summary (PCS) (p = 0.33), the mental component summary (MCS = 0.16), or the visual analogue scale (VAS) (p = 0.12). The accurate restoration of COR based on preoperative planning is not associated with improved clinical outcomes. During postoperative evaluation, surgeons should feel confident if the COR is slightly greater than 5 mm of preoperative limitations.
- 28 November 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 138 (3) , 325-330
Functional outcomes after removal of hardware in patellar fracture: are we helping our patients?
- 28 November 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 138 (3) , 325-330
Functional outcomes after removal of hardware in patellar fracture: are we helping our patients?