Dmitrii Burovikhin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dmitrii Burovikhin has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Michael Lauxmann
Reutlingen University Reutlingen Germany
3 shared publications - Andreas Fasold-Schmid
Reutlingen Research Institute
1 shared publication - Andreas Wagner
Department of Anatomy, Eberhard Karls University of Tübingen , Elfriede-Aulhorn-Strasse 8, Tübingen 72076, Germany
1 shared publication Benjamin Sackmann
Reutlingen University
1 shared publicationErnst Dalhoff
University of Tübingen, Tübingen , Germany
1 shared publication- Ernst Dalhoff
Section of Physiological Acoustics and Communication, Dept. of Otolaryngology, Eberhard-Karls-University Tübingen, Elfriede-Aulhorn-Str. 5, 72076 Tübingen, Germany
1 shared publication
Latest Publications
- Open Access
Optimal Position and Orientation of an Ossicular Accelerometer for Human Auditory Prostheses
In this study, a method for determining the optimal location and orientation of an implantable piezoelectric accelerometer on the short process of the incus is presented. The accelerometer is intended to be used as a replacement for an external microphone to enable totally implantable auditory prostheses. The optimal orientation of the sensor and the best attachment point are determined based on two criteria—maximum pressure sensitivity sum and minimum loudness level sum. The best location is determined to be near the incudomalleolar joint. We find that the angular orientation of the sensor is critical and provide guidelines on that orientation. The method described in this paper can be used to further optimize the design and performance of the accelerometer.
Open AccessOptimal Position and Orientation of an Ossicular Accelerometer for Human Auditory Prostheses
In this study, a method for determining the optimal location and orientation of an implantable piezoelectric accelerometer on the short process of the incus is presented. The accelerometer is intended to be used as a replacement for an external microphone to enable totally implantable auditory prostheses. The optimal orientation of the sensor and the best attachment point are determined based on two criteria—maximum pressure sensitivity sum and minimum loudness level sum. The best location is determined to be near the incudomalleolar joint. We find that the angular orientation of the sensor is critical and provide guidelines on that orientation. The method described in this paper can be used to further optimize the design and performance of the accelerometer.
- Open Access
- 1 December 2024
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 10 (4) , 135-139
Placement and Orientation of an Accelerometer Sensor Attached to the Human Incus in Hearing Implants
In this study a method for determining the best placement and optimal orientation of the implantable piezoelectric accelerometer attached to the short process of the incus is developed. The accelerometer is intended to be used as a replacement for an external microphone to enable totally implantable cochlea implants or as part of a totally implantable hearing aid. The best location is determined to be near the incudomalleolar joint. The optimal orientation of the sensor at the determined location is obtained using two criteria - maximum voltage sum and minimum loudness level sum. The method described in the paper can be used to further optimize the design and the performance of the accelerometer.
- 1 December 2024
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 10 (4) , 135-139
Open AccessPlacement and Orientation of an Accelerometer Sensor Attached to the Human Incus in Hearing Implants
In this study a method for determining the best placement and optimal orientation of the implantable piezoelectric accelerometer attached to the short process of the incus is developed. The accelerometer is intended to be used as a replacement for an external microphone to enable totally implantable cochlea implants or as part of a totally implantable hearing aid. The best location is determined to be near the incudomalleolar joint. The optimal orientation of the sensor at the determined location is obtained using two criteria - maximum voltage sum and minimum loudness level sum. The method described in the paper can be used to further optimize the design and the performance of the accelerometer.
- 6 October 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (2)
Finite Element Model of a Piezo-Electric Actuator Coupled to the Middle Ear
The hearing contact lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL's performance, a model of the HCL coupled to a middle-ear model was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a laser-doppler-vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model, and additional LDV measurements on temporal bones were performed to validate the coupled model that was used to evaluate the equivalent sound pressure of the HCL. Moreover, a de-eper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.
- 6 October 2022
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (2)
Finite Element Model of a Piezo-Electric Actuator Coupled to the Middle Ear
The hearing contact lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL's performance, a model of the HCL coupled to a middle-ear model was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a laser-doppler-vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model, and additional LDV measurements on temporal bones were performed to validate the coupled model that was used to evaluate the equivalent sound pressure of the HCL. Moreover, a de-eper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.
- Open Access
- 1 October 2021
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 7 (2) , 379-382
Finite Element Modelling of a Hearing Contact Lens Coupled to the Middle Ear
Hearing contact lens (HCL) is a new type of hearing aid devices. One of its main components is a piezoelectric actuator (PEA). In order to evaluate and maximize the HCL’s performance, a model of the HCL coupled to the middle ear was developed using finite element (FE) approach. To validate the model, vibrational measurements on the HCL and temporal bones were performed using a Laser-Doppler-Vibrometer (LDV). The model was validated step by step starting with HCL only. Then a silicone cap was fitted onto the HCL to provide an interface between the HCL and the tympanic membrane. The HCL was placed on the tympanic membrane and additional measurements were performed to validate the coupled model. The model was used to evaluate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL. Moreover, deeper insight was gained into the feedback behavior, which causes whistling sounds, and the contact between the HCL and tympanic membrane.
- 1 October 2021
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 7 (2) , 379-382
Open AccessFinite Element Modelling of a Hearing Contact Lens Coupled to the Middle Ear
Hearing contact lens (HCL) is a new type of hearing aid devices. One of its main components is a piezoelectric actuator (PEA). In order to evaluate and maximize the HCL’s performance, a model of the HCL coupled to the middle ear was developed using finite element (FE) approach. To validate the model, vibrational measurements on the HCL and temporal bones were performed using a Laser-Doppler-Vibrometer (LDV). The model was validated step by step starting with HCL only. Then a silicone cap was fitted onto the HCL to provide an interface between the HCL and the tympanic membrane. The HCL was placed on the tympanic membrane and additional measurements were performed to validate the coupled model. The model was used to evaluate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL. Moreover, deeper insight was gained into the feedback behavior, which causes whistling sounds, and the contact between the HCL and tympanic membrane.
- 28 June 2019
- Published by Springer Nature
- p. 18-25
Investigation of Inhomogeneous Stiffness and Damping Characteristics of the Human Stapedial Annular Ligament
- 28 June 2019
- Published by Springer Nature
- p. 18-25
Investigation of Inhomogeneous Stiffness and Damping Characteristics of the Human Stapedial Annular Ligament
- 1 January 2016
- Published by Springer Nature
- p. 79-99
Application to CAE Systems