Harald Rittger
Harald Rittger has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Veronica Buia
Clinic Fuerth , Fuerth , Germany
5 shared publications - Laura Vitali-Serdoz
Clinic Fuerth , Fuerth , Germany
4 shared publications Christian Schlundt
Medizinische Klinik 2, Universitätsklinikum Erlangen, Erlangen, Germany
2 shared publications- D Bastian
Clinic Fuerth , Fuerth , Germany
2 shared publications D Stangl
Clinic Fuerth , Fuerth , Germany
2 shared publications- Dirk Bastian
Medizinische Klinik I, Klinikum Fürth, Academic Teaching Hospital of the Friedrich-Alexander-University Erlangen-Nürnberg , Jakob-Henle-Str. 1, Fürth 90766
2 shared publications
Latest Publications
- 2 April 2025
- Published by Georg Thieme Verlag KG in Aktuelle Kardiologie
- Vol. 14 (02) , 154-159
Das chronische Koronarsyndrom beim älteren Patienten und Niereninsuffizienz – Was ist zu bedenken?
Zusammenfassung: Das chronische Koronarsyndrom (CCS) ist eine bedeutende kardiovaskuläre Erkrankung, die insbesondere ältere Patienten mit gleichzeitiger Niereninsuffizienz betrifft. Aufgrund des komplexen Zusammenspiels dieser Syndrome stellen Diagnose und Therapie stets eine besondere Herausforderung dar. Diese Arbeit adressiert aktuelle Erkenntnisse zur Pathophysiologie, Diagnostik und Behandlung und gibt einen Überblick über klinische Studien und evidenzbasierte Leitlinien.
- 2 April 2025
- Published by Georg Thieme Verlag KG in Aktuelle Kardiologie
- Vol. 14 (02) , 154-159
Das chronische Koronarsyndrom beim älteren Patienten und Niereninsuffizienz – Was ist zu bedenken?
Zusammenfassung: Das chronische Koronarsyndrom (CCS) ist eine bedeutende kardiovaskuläre Erkrankung, die insbesondere ältere Patienten mit gleichzeitiger Niereninsuffizienz betrifft. Aufgrund des komplexen Zusammenspiels dieser Syndrome stellen Diagnose und Therapie stets eine besondere Herausforderung dar. Diese Arbeit adressiert aktuelle Erkenntnisse zur Pathophysiologie, Diagnostik und Behandlung und gibt einen Überblick über klinische Studien und evidenzbasierte Leitlinien.
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
His bundle pacing implantation in octogenarian patients: a substudy of the PACE-CONDUCT trial
Background: His bundle pacing (HBP) is gaining recognition as a valuable alternative for the management of various cardiac conduction disorders. This substudy, conducted within the framework of the PACE-CONDUCT trial, investigates the outcomes of HBP implantation in patients aged 80 years and older, comparing them with a younger cohort. Methods: We examined a total of 61 consecutive patients who underwent HBP implantation, utilizing DDD pacemakers, CRT-P, or CRT-D devices, during the years 2021 to 2023. Patients were categorized into two subgroups: those aged younger than 80 years and those aged 80 years or older. The mean age of the entire cohort was 73 years, spanning from 51 to 86 years, with 15 patients (comprising 24.6% of the total) falling into the octogenarian category. His bundle threshold was assessed on the day of implantation, one day post-implantation, and four weeks post-implantation. All HBP implantations were deemed successful, incorporating both selective and non-selective His bundle pacing. Complications were classified as major (necessitating lead or pocket revision) or minor (requiring no revision). Threshold values were converted to volts per milliseconds (volts x milliseconds) for statistical analysis, conducted with IBM SPSS Statistics 29.0. Results: Initial analysis revealed a consistent success rate of HBP implantation across all patients, with no discernible differences between the two age groups. Threshold measurements at the day of implantation and after one day indicated no differences between the younger and the older group. However, at the four-week mark, a statistically significant lower threshold of His bundle pacing was observed in the octogenarian group (one-sided p-value 0.028), suggesting a faster stabilization to the chronic threshold of the active fixation His Bundle lead. The comparison of major and minor complications between the age groups, conducted using chi-square tests, revealed no age-related discrepancies. Conclusions: This substudy of the PACE-CONDUCT trial underscores the feasibility and safety of His bundle pacing implantation in octogenarian patients, comparable to their younger counterparts. While no initial threshold variations are observed, the octogenarian group demonstrated improved His bundle pacing thresholds approximately four weeks post-implantation. Importantly, the study revealed no heightened complication risk associated with advanced age, affirming that very old patients aged 80 or older can derive the benefits of His bundle pacing without increased complication rates. Given the relatively modest patient cohort in this study, further investigations are warranted to validate and extend these findings.T-tests and Chi square tests
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessHis bundle pacing implantation in octogenarian patients: a substudy of the PACE-CONDUCT trial
Background: His bundle pacing (HBP) is gaining recognition as a valuable alternative for the management of various cardiac conduction disorders. This substudy, conducted within the framework of the PACE-CONDUCT trial, investigates the outcomes of HBP implantation in patients aged 80 years and older, comparing them with a younger cohort. Methods: We examined a total of 61 consecutive patients who underwent HBP implantation, utilizing DDD pacemakers, CRT-P, or CRT-D devices, during the years 2021 to 2023. Patients were categorized into two subgroups: those aged younger than 80 years and those aged 80 years or older. The mean age of the entire cohort was 73 years, spanning from 51 to 86 years, with 15 patients (comprising 24.6% of the total) falling into the octogenarian category. His bundle threshold was assessed on the day of implantation, one day post-implantation, and four weeks post-implantation. All HBP implantations were deemed successful, incorporating both selective and non-selective His bundle pacing. Complications were classified as major (necessitating lead or pocket revision) or minor (requiring no revision). Threshold values were converted to volts per milliseconds (volts x milliseconds) for statistical analysis, conducted with IBM SPSS Statistics 29.0. Results: Initial analysis revealed a consistent success rate of HBP implantation across all patients, with no discernible differences between the two age groups. Threshold measurements at the day of implantation and after one day indicated no differences between the younger and the older group. However, at the four-week mark, a statistically significant lower threshold of His bundle pacing was observed in the octogenarian group (one-sided p-value 0.028), suggesting a faster stabilization to the chronic threshold of the active fixation His Bundle lead. The comparison of major and minor complications between the age groups, conducted using chi-square tests, revealed no age-related discrepancies. Conclusions: This substudy of the PACE-CONDUCT trial underscores the feasibility and safety of His bundle pacing implantation in octogenarian patients, comparable to their younger counterparts. While no initial threshold variations are observed, the octogenarian group demonstrated improved His bundle pacing thresholds approximately four weeks post-implantation. Importantly, the study revealed no heightened complication risk associated with advanced age, affirming that very old patients aged 80 or older can derive the benefits of His bundle pacing without increased complication rates. Given the relatively modest patient cohort in this study, further investigations are warranted to validate and extend these findings.T-tests and Chi square tests
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Temporal evolution of His bundle pacing thresholds: a sub-study of the PACE-CONDUCT trial
Background: His bundle pacing (HBP) has become a valuable alternative for cardiac resynchronization therapy, offering physiological pacing. This substudy of the PACE-CONDUCT trial aimed to explore the influence selective and non-selective HBP on threshold height. We assessed these parameters in patients with both normal conduction and bundle branch block conduction. Methods: Our study included 61 consecutive patients with a median age of 73 years, who underwent a successful HBP implantation for indications such as sick sinus syndrome, AV Block 2 type 2, binodal disease, and ablate and pace therapy prior to AV-node ablation. Among these patients, 18 exhibited QRS durations exceeding 150 ms, indicating a complete and broad bundle branch block which made them candidates for cardiac resynchronization therapy (CRT). All patients received HBP implantation with the assistance of a 3D electroanatomical system. This system allowed for low-fluoroscopic, atraumatic evaluation of the His bundle (HB) area, presenting the His voltage as a color-coded map for precise electrode placement. Results: The feasibility of bundle branch correction is generally accepted in selective HBP distal to the site of block, albeit associated with higher threshold values and potentially lower battery duration. Our analysis encompassed 61 patients who underwent HBP implantation, with 23 patients (37,7%) exhibiting selective HBP and 38 (62,3%) non-selective HBP. Remarkably, 10 out of the 23 patients with selective HBP demonstrated a complete bundle branch block correction after HBP implantation even with a basal QRS durations exceeding 150 ms. We evaluated HBP thresholds at implantation, one day post-implantation, and one month post-implantation, correlating these data with selective and non-selective HBP. Threshold values were converted to volts per millisecond (volts × milliseconds) for analysis. Statistical analysis conducted with IBM SPSS 29.0 revealed a significant difference at the day of implantation, indicating higher threshold capture in selective HBP compared to non-selective HBP (one-sided p-value: < 0.01, two sided p value 0.01). However, this difference could not be sustained at the one-day and one-month threshold follow-ups, suggesting normalization of the selective HBP threshold. Conclusion: In our study, the initially higher threshold in selective HBP normalized within 24 hours compared to non-selective HBP. Additionally, our study demonstrated the feasibility of selective His pacing in patients with complete bundle branch block and broad QRS durations. These findings provide insights into HBP optimization and encourage further investigations with larger patient cohorts to validate our observations and enhance patient care in the realm of cardiac pacing.Threshold trend
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessTemporal evolution of His bundle pacing thresholds: a sub-study of the PACE-CONDUCT trial
Background: His bundle pacing (HBP) has become a valuable alternative for cardiac resynchronization therapy, offering physiological pacing. This substudy of the PACE-CONDUCT trial aimed to explore the influence selective and non-selective HBP on threshold height. We assessed these parameters in patients with both normal conduction and bundle branch block conduction. Methods: Our study included 61 consecutive patients with a median age of 73 years, who underwent a successful HBP implantation for indications such as sick sinus syndrome, AV Block 2 type 2, binodal disease, and ablate and pace therapy prior to AV-node ablation. Among these patients, 18 exhibited QRS durations exceeding 150 ms, indicating a complete and broad bundle branch block which made them candidates for cardiac resynchronization therapy (CRT). All patients received HBP implantation with the assistance of a 3D electroanatomical system. This system allowed for low-fluoroscopic, atraumatic evaluation of the His bundle (HB) area, presenting the His voltage as a color-coded map for precise electrode placement. Results: The feasibility of bundle branch correction is generally accepted in selective HBP distal to the site of block, albeit associated with higher threshold values and potentially lower battery duration. Our analysis encompassed 61 patients who underwent HBP implantation, with 23 patients (37,7%) exhibiting selective HBP and 38 (62,3%) non-selective HBP. Remarkably, 10 out of the 23 patients with selective HBP demonstrated a complete bundle branch block correction after HBP implantation even with a basal QRS durations exceeding 150 ms. We evaluated HBP thresholds at implantation, one day post-implantation, and one month post-implantation, correlating these data with selective and non-selective HBP. Threshold values were converted to volts per millisecond (volts × milliseconds) for analysis. Statistical analysis conducted with IBM SPSS 29.0 revealed a significant difference at the day of implantation, indicating higher threshold capture in selective HBP compared to non-selective HBP (one-sided p-value: < 0.01, two sided p value 0.01). However, this difference could not be sustained at the one-day and one-month threshold follow-ups, suggesting normalization of the selective HBP threshold. Conclusion: In our study, the initially higher threshold in selective HBP normalized within 24 hours compared to non-selective HBP. Additionally, our study demonstrated the feasibility of selective His pacing in patients with complete bundle branch block and broad QRS durations. These findings provide insights into HBP optimization and encourage further investigations with larger patient cohorts to validate our observations and enhance patient care in the realm of cardiac pacing.Threshold trend
- Open Access
MEMS Technology in Cardiology: Advancements and Applications in Heart Failure Management Focusing on the CardioMEMS Device
Heart failure (HF) is a complex clinical syndrome associated with significant morbidity, mortality, and healthcare costs. It is characterized by various structural and/or functional abnormalities of the heart, resulting in elevated intracardiac pressure and/or inadequate cardiac output at rest and/or during exercise. These dysfunctions can originate from a variety of conditions, including coronary artery disease, hypertension, cardiomyopathies, heart valve disorders, arrhythmias, and other lifestyle or systemic factors. Identifying the underlying cause is crucial for detecting reversible or treatable forms of HF. Recent epidemiological studies indicate that there has not been an increase in the incidence of the disease. Instead, patients seem to experience a chronic trajectory marked by frequent hospitalizations and stagnant mortality rates. Managing these patients requires a multidisciplinary approach that focuses on preventing disease progression, controlling symptoms, and preventing acute decompensations. In the outpatient setting, patient self-care plays a vital role in achieving these goals. This involves implementing necessary lifestyle changes and promptly recognizing symptoms/signs such as dyspnea, lower limb edema, or unexpected weight gain over a few days, to alert the healthcare team for evaluation of medication adjustments. Traditional methods of HF monitoring, such as symptom assessment and periodic clinic visits, may not capture subtle changes in hemodynamics. Sensor-based technologies offer a promising solution for remote monitoring of HF patients, enabling early detection of fluid overload and optimization of medical therapy. In this review, we provide an overview of the CardioMEMS device, a novel sensor-based system for pulmonary artery pressure monitoring in HF patients. We discuss the technical aspects, clinical evidence, and future directions of CardioMEMS in HF management.
Open AccessMEMS Technology in Cardiology: Advancements and Applications in Heart Failure Management Focusing on the CardioMEMS Device
Heart failure (HF) is a complex clinical syndrome associated with significant morbidity, mortality, and healthcare costs. It is characterized by various structural and/or functional abnormalities of the heart, resulting in elevated intracardiac pressure and/or inadequate cardiac output at rest and/or during exercise. These dysfunctions can originate from a variety of conditions, including coronary artery disease, hypertension, cardiomyopathies, heart valve disorders, arrhythmias, and other lifestyle or systemic factors. Identifying the underlying cause is crucial for detecting reversible or treatable forms of HF. Recent epidemiological studies indicate that there has not been an increase in the incidence of the disease. Instead, patients seem to experience a chronic trajectory marked by frequent hospitalizations and stagnant mortality rates. Managing these patients requires a multidisciplinary approach that focuses on preventing disease progression, controlling symptoms, and preventing acute decompensations. In the outpatient setting, patient self-care plays a vital role in achieving these goals. This involves implementing necessary lifestyle changes and promptly recognizing symptoms/signs such as dyspnea, lower limb edema, or unexpected weight gain over a few days, to alert the healthcare team for evaluation of medication adjustments. Traditional methods of HF monitoring, such as symptom assessment and periodic clinic visits, may not capture subtle changes in hemodynamics. Sensor-based technologies offer a promising solution for remote monitoring of HF patients, enabling early detection of fluid overload and optimization of medical therapy. In this review, we provide an overview of the CardioMEMS device, a novel sensor-based system for pulmonary artery pressure monitoring in HF patients. We discuss the technical aspects, clinical evidence, and future directions of CardioMEMS in HF management.
- Open Access
- 15 March 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (6) , 622
Fusion Imaging of Non-Invasive and Invasive Cardiac Electroanatomic Mapping in Patients with Ventricular Ectopic Beats: A Feasibility Analysis in a Case Series
In patients with premature ventricular contractions (PVCs), non-invasive mapping could locate the PVCs’ origin on a personalized 3-dimensional (3D) heart model and, thus, facilitate catheter ablation therapy planning. The aim of our report is to evaluate its accuracy compared to invasive mapping in terms of assessing the PVCs’ early activation zone (EAZ). For this purpose, non-invasive electrocardiographic imaging (ECGI) was performed using the Amycard 01C system (EP Solutions SA, Switzerland) in three cases. In the first step, a multichannel ECG (up to 224 electrodes) was recorded, and the dominant PVCs were registered. Afterward, a cardiac computed tomography (in two cases) or magnetic resonance imaging (in one case) investigation was carried out acquiring non-contrast torso scans for 8-electrode strip visualization and contrast heart acquisition. For the reconstructed epi/endocardial meshes of the heart, non-invasive isochronal maps were generated for the selected multichannel ECG fragments. Then, the patients underwent an invasive electrophysiological study, and the PVCs’ activation was evaluated by a 3D mapping system (EnSite NavX Precision, Abbott). Finally, using custom-written software, we performed 3D fusion of the non-invasive and invasive models and compared the resulting isochronal maps. A qualitative analysis in each case showed the same early localization of the dominant PVC on the endocardial surface when comparing the non-invasive and invasive isochronal maps. The distance from the EAZ to the mitral or tricuspid annulus was comparable in the invasive/non-invasive data (36/41 mm in case N1, 73/75 mm in case N2, 9/12 mm in case N3). The area of EAZ was also similar between the invasive/non-invasive maps (4.3/4.5 cm2 in case N1, 7.1/7.0 cm2 in case N2, 0.4/0.6 cm2 in case N3). The distances from the non-invasive to invasive earliest activation site were 4 mm in case N1, 7 mm in case N2, and 4 mm in case N3. Such results were appropriate to trust the clinical value of the preoperative data in these cases. In conclusion, the non-invasive identification of PVCs before an invasive electrophysiological study can guide clinical and interventional decisions, demonstrating appropriate accuracy in the estimation of focus origin.
- 15 March 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (6) , 622
Open AccessFusion Imaging of Non-Invasive and Invasive Cardiac Electroanatomic Mapping in Patients with Ventricular Ectopic Beats: A Feasibility Analysis in a Case Series
In patients with premature ventricular contractions (PVCs), non-invasive mapping could locate the PVCs’ origin on a personalized 3-dimensional (3D) heart model and, thus, facilitate catheter ablation therapy planning. The aim of our report is to evaluate its accuracy compared to invasive mapping in terms of assessing the PVCs’ early activation zone (EAZ). For this purpose, non-invasive electrocardiographic imaging (ECGI) was performed using the Amycard 01C system (EP Solutions SA, Switzerland) in three cases. In the first step, a multichannel ECG (up to 224 electrodes) was recorded, and the dominant PVCs were registered. Afterward, a cardiac computed tomography (in two cases) or magnetic resonance imaging (in one case) investigation was carried out acquiring non-contrast torso scans for 8-electrode strip visualization and contrast heart acquisition. For the reconstructed epi/endocardial meshes of the heart, non-invasive isochronal maps were generated for the selected multichannel ECG fragments. Then, the patients underwent an invasive electrophysiological study, and the PVCs’ activation was evaluated by a 3D mapping system (EnSite NavX Precision, Abbott). Finally, using custom-written software, we performed 3D fusion of the non-invasive and invasive models and compared the resulting isochronal maps. A qualitative analysis in each case showed the same early localization of the dominant PVC on the endocardial surface when comparing the non-invasive and invasive isochronal maps. The distance from the EAZ to the mitral or tricuspid annulus was comparable in the invasive/non-invasive data (36/41 mm in case N1, 73/75 mm in case N2, 9/12 mm in case N3). The area of EAZ was also similar between the invasive/non-invasive maps (4.3/4.5 cm2 in case N1, 7.1/7.0 cm2 in case N2, 0.4/0.6 cm2 in case N3). The distances from the non-invasive to invasive earliest activation site were 4 mm in case N1, 7 mm in case N2, and 4 mm in case N3. Such results were appropriate to trust the clinical value of the preoperative data in these cases. In conclusion, the non-invasive identification of PVCs before an invasive electrophysiological study can guide clinical and interventional decisions, demonstrating appropriate accuracy in the estimation of focus origin.
- 13 September 2022
- Published by Springer Nature in Die Kardiologie
- Vol. 16 (6) , 456-465
Cholesterinsenkende Therapie bei älteren Patienten
- 13 September 2022
- Published by Springer Nature in Die Kardiologie
- Vol. 16 (6) , 456-465
Cholesterinsenkende Therapie bei älteren Patienten
- Open Access
Perioperative Sensor and Algorithm Programming in Patients with Implanted ICDs and Pacemakers for Cardiac Resynchronization Therapy
Background: ICDs and pacemakers for cardiac resynchronization therapy (CRT) are complex devices with different sensors and automatic algorithms implanted in patients with advanced cardiac diseases. Data on the perioperative management and outcome of CRT carriers undergoing surgery unrelated to the device are scarce. Methods: Data from 198 CRT device carriers (100 with active rate responsive sensor) were evaluated regarding perioperative adverse (device-related) events (A(D)E) and lead parameter changes. Results: Thirty-nine adverse observations were documented in 180 patients during preoperative interrogation, which were most often related to the left-ventricular lead and requiring intervention/reprogramming in 22 cases (12%). Anesthesia-related events occurred in 69 patients. There was no ADE for non-cardiac surgery and in pacemaker-dependent patients not programmed to an asynchronous pacing mode. Post-operative device interrogation showed significant lead parameter changes in 64/179 patients (36%) requiring reprogramming in 29 cases (16%). Conclusion: The left-ventricular pacing lead represents the most vulnerable system component. Comprehensive pre and post-interventional device interrogation is mandatory to ensure proper system function. The type of ICD function suspension has no impact on each patient’s outcome. Precautionary activity sensor deactivation is not required for non-cardiac interventions. Routine prophylactic device reprogramming to asynchronous pacing appears inessential. Most of the CRT pacemakers do not require surgery-related reprogramming.
Open AccessPerioperative Sensor and Algorithm Programming in Patients with Implanted ICDs and Pacemakers for Cardiac Resynchronization Therapy
Background: ICDs and pacemakers for cardiac resynchronization therapy (CRT) are complex devices with different sensors and automatic algorithms implanted in patients with advanced cardiac diseases. Data on the perioperative management and outcome of CRT carriers undergoing surgery unrelated to the device are scarce. Methods: Data from 198 CRT device carriers (100 with active rate responsive sensor) were evaluated regarding perioperative adverse (device-related) events (A(D)E) and lead parameter changes. Results: Thirty-nine adverse observations were documented in 180 patients during preoperative interrogation, which were most often related to the left-ventricular lead and requiring intervention/reprogramming in 22 cases (12%). Anesthesia-related events occurred in 69 patients. There was no ADE for non-cardiac surgery and in pacemaker-dependent patients not programmed to an asynchronous pacing mode. Post-operative device interrogation showed significant lead parameter changes in 64/179 patients (36%) requiring reprogramming in 29 cases (16%). Conclusion: The left-ventricular pacing lead represents the most vulnerable system component. Comprehensive pre and post-interventional device interrogation is mandatory to ensure proper system function. The type of ICD function suspension has no impact on each patient’s outcome. Precautionary activity sensor deactivation is not required for non-cardiac interventions. Routine prophylactic device reprogramming to asynchronous pacing appears inessential. Most of the CRT pacemakers do not require surgery-related reprogramming.
- 1 October 2020
- Published by Georg Thieme Verlag KG in Aktuelle Kardiologie
- Vol. 9 (05) , 448-452
Extracorporeal Life Support - Even in Elderly Patients?
In patients with cardiogenic shock, there is limited organ perfusion due to severely reduced systolic cardiac function. Prognosis is bad and mortality in patients with cardiogenic shock remains high, especially in the light of multiorgan damage, which often is a result of cardiogenic shock. The usefulness of advanced life support technologies like ECMO (extracorporeal membrane oxygenation) in elderly patients remains subject of an ongoing discussion. Evidence is limited, since studies are hard to perform, especially in the elderly patient group. Additionally, ethical aspects play a major role in decision making with this limited and expensive technology. The present article focuses on the characteristics of elderly patients with cardiogenic shock and need for advanced therapies.
- 1 October 2020
- Published by Georg Thieme Verlag KG in Aktuelle Kardiologie
- Vol. 9 (05) , 448-452
Extracorporeal Life Support - Even in Elderly Patients?
In patients with cardiogenic shock, there is limited organ perfusion due to severely reduced systolic cardiac function. Prognosis is bad and mortality in patients with cardiogenic shock remains high, especially in the light of multiorgan damage, which often is a result of cardiogenic shock. The usefulness of advanced life support technologies like ECMO (extracorporeal membrane oxygenation) in elderly patients remains subject of an ongoing discussion. Evidence is limited, since studies are hard to perform, especially in the elderly patient group. Additionally, ethical aspects play a major role in decision making with this limited and expensive technology. The present article focuses on the characteristics of elderly patients with cardiogenic shock and need for advanced therapies.
- Open Access
- 1 January 2018
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. 13, 1935-1943
Differences of patients' perceptions for elective diagnostic coronary angiography and percutaneous coronary intervention in stable coronary artery disease between elderly and younger patients
Aims: There is limited evidence of the differences in expectations between elderly (>= 80 years) and younger patients (= 80 years. For these elderly patients the questions "to remain independent," "to maintain mobility, so that I can maintain my current life," and "to prevent myocardial infarction" were rated highest. Regarding "hard" cardiac endpoints "to avoid PCI in the future" was rated lowest in younger and in elderly patients. Significant differences were found between the age groups with the items "to avoid myocardial infarction," "avoid heart insufficiency," "to extend my life" and "to maintain mobility so that I can maintain my current life" (P<0.001). Conclusions: In our survey we found significant differences in patient expectations between elderly and younger patients regarding the outcome of DA/PCI.
- 1 January 2018
- Published by Taylor & Francis in Clinical Interventions in Aging
- Vol. 13, 1935-1943
Open AccessDifferences of patients' perceptions for elective diagnostic coronary angiography and percutaneous coronary intervention in stable coronary artery disease between elderly and younger patients
Aims: There is limited evidence of the differences in expectations between elderly (>= 80 years) and younger patients (= 80 years. For these elderly patients the questions "to remain independent," "to maintain mobility, so that I can maintain my current life," and "to prevent myocardial infarction" were rated highest. Regarding "hard" cardiac endpoints "to avoid PCI in the future" was rated lowest in younger and in elderly patients. Significant differences were found between the age groups with the items "to avoid myocardial infarction," "avoid heart insufficiency," "to extend my life" and "to maintain mobility so that I can maintain my current life" (P<0.001). Conclusions: In our survey we found significant differences in patient expectations between elderly and younger patients regarding the outcome of DA/PCI.
- 19 February 2016
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 88 (4) , 529-534
Angiographic patterns of drug-eluting stent restenosis after treatment with drug-coated balloon versus balloon angioplasty: Late lumen loss subgroup analyses of the PEPCAD-DES study
This report provides the results of additional late lumen loss (LLL) analyses the predefined subgroup of diabetics and post hoc analyses of selected lesion morphologies to further elucidate the efficacy of paclitaxel coated balloon (PCB) angioplasty (clinical trials identifier NCT00998439).The PEPCAD-DES trial revealed that in lesion LLL and the target lesion revascularization rate (TLR) were significantly reduced with PCB angioplasty as compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent restenosis (DES-ISR).A total of 110 patients with restenosis of Sirolimus- (SES), Everolimus- (EES), or Paclitaxel-eluting (PES) stents in native coronary arteries were randomized 2:1 to receive treatment with PCB (72 patients) or POBA (38 patients).In the PCB group, LLL did not differ for PES versus non-PES lesions (0.46 ± 0.55 mm vs. 0.41 ± 0.65 mm, P = 0.81). Moreover, there was no difference in LLL when PCB's were used in single and multiple layer DES-ISR (0.35 ± 0.60 mm vs. 0.51 ± 0.63 mm, P = 0.31). In contrast, patients treated with POBA for multilayer DES-ISR were more likely to have significantly higher LLL as compared with single layer DES-ISR (1.29 ± 0.76 mm vs. 0.65 ± 0.60 mm, P = 0.02). There was no LLL difference between diabetics and non-diabetics when treated with PCB angioplasty (0.46 ± 0.76 mm vs. 0.43 ± 0.54 mm, P = 0.83).Our hypothesis generating results indicated that there were no differences in terms of LLL when PCB angioplasty was applied in subgroups of single versus multiple layer DES-ISR and PES-ISR versus non-PES ISR. LLL was not higher in diabetic patients as compared with the their non-diabetic counterparts when treated with PCB's. © 2016 Wiley Periodicals, Inc.
- 19 February 2016
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 88 (4) , 529-534
Angiographic patterns of drug-eluting stent restenosis after treatment with drug-coated balloon versus balloon angioplasty: Late lumen loss subgroup analyses of the PEPCAD-DES study
This report provides the results of additional late lumen loss (LLL) analyses the predefined subgroup of diabetics and post hoc analyses of selected lesion morphologies to further elucidate the efficacy of paclitaxel coated balloon (PCB) angioplasty (clinical trials identifier NCT00998439).The PEPCAD-DES trial revealed that in lesion LLL and the target lesion revascularization rate (TLR) were significantly reduced with PCB angioplasty as compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent restenosis (DES-ISR).A total of 110 patients with restenosis of Sirolimus- (SES), Everolimus- (EES), or Paclitaxel-eluting (PES) stents in native coronary arteries were randomized 2:1 to receive treatment with PCB (72 patients) or POBA (38 patients).In the PCB group, LLL did not differ for PES versus non-PES lesions (0.46 ± 0.55 mm vs. 0.41 ± 0.65 mm, P = 0.81). Moreover, there was no difference in LLL when PCB's were used in single and multiple layer DES-ISR (0.35 ± 0.60 mm vs. 0.51 ± 0.63 mm, P = 0.31). In contrast, patients treated with POBA for multilayer DES-ISR were more likely to have significantly higher LLL as compared with single layer DES-ISR (1.29 ± 0.76 mm vs. 0.65 ± 0.60 mm, P = 0.02). There was no LLL difference between diabetics and non-diabetics when treated with PCB angioplasty (0.46 ± 0.76 mm vs. 0.43 ± 0.54 mm, P = 0.83).Our hypothesis generating results indicated that there were no differences in terms of LLL when PCB angioplasty was applied in subgroups of single versus multiple layer DES-ISR and PES-ISR versus non-PES ISR. LLL was not higher in diabetic patients as compared with the their non-diabetic counterparts when treated with PCB's. © 2016 Wiley Periodicals, Inc.