David L. Hastings
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David L. Hastings has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Andrew J. Reader
King’s College London
3 shared publications P.J. Julyan
North Western Medical Physics, Christie Hospital, Manchester, UK
2 shared publicationsA. P. Jeavons
1 shared publicationA.P. Jeavons
Oxford Positron Systems, Oxfordshire, UK
1 shared publicationJ. C. Hand
1 shared publicationJ. V. Moore
1 shared publication
Latest Publications
- 4 December 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 573 (1-2) , 80-83
Performance characteristics of a small animal PET camera for molecular imaging
- 4 December 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 573 (1-2) , 80-83
Performance characteristics of a small animal PET camera for molecular imaging
- 16 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (5) , 2778-2786
Noise Properties of Four Strategies for Incorporation of Scatter and Attenuation Information in PET Reconstruction Using the EM-ML Algorithm
Conventional methods for dealing with attenuation and scatter in PET can limit the reconstructed image quality, particularly if the attenuating medium is large (as in whole body 3D PET). In such cases, often a substantial scatter subtraction is performed followed by amplification of the remaining data (to correct for attenuation) resulting in noisy reconstructions. More recent iterative reconstruction methods include the attenuation in the system model in conjunction with either pre-scatter subtraction or a separate addition of the scatter component after each application of the forward model. This work compares these more conventional approaches of including attenuation and scatter to the case where attenuation and scatter information are both included within the system matrix used by the expectation maximization maximum likelihood (EM-ML) algorithm. For this case all acquired data are used and regarded as a source of information by the reconstruction algorithm. Multiple realisations of simulated data sets have been used to compare the performance of the unified attenuation and scatter model with other methods. For a large attenuating medium and low counts there are notable differences between the four main ways of including attenuation and scatter within the reconstruction-with full pre-correction of the data being inferior compared to all the other methods, and the method which models scatter and attenuation within the system matrix showing some advantages. This work suggests that if regularisation of the EM algorithm is carried out by early termination of the iterative process, the subtraction method is the better approach among the techniques considered. In contrast, if a post-reconstruction smoothing approach to regularisation is to be used (whereby highly iterated, noisy image estimates are smoothed), the full modeling method for attenuation and scatter yields the better results, albeit at the computational cost of many more iterations being required
- 16 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (5) , 2778-2786
Noise Properties of Four Strategies for Incorporation of Scatter and Attenuation Information in PET Reconstruction Using the EM-ML Algorithm
Conventional methods for dealing with attenuation and scatter in PET can limit the reconstructed image quality, particularly if the attenuating medium is large (as in whole body 3D PET). In such cases, often a substantial scatter subtraction is performed followed by amplification of the remaining data (to correct for attenuation) resulting in noisy reconstructions. More recent iterative reconstruction methods include the attenuation in the system model in conjunction with either pre-scatter subtraction or a separate addition of the scatter component after each application of the forward model. This work compares these more conventional approaches of including attenuation and scatter to the case where attenuation and scatter information are both included within the system matrix used by the expectation maximization maximum likelihood (EM-ML) algorithm. For this case all acquired data are used and regarded as a source of information by the reconstruction algorithm. Multiple realisations of simulated data sets have been used to compare the performance of the unified attenuation and scatter model with other methods. For a large attenuating medium and low counts there are notable differences between the four main ways of including attenuation and scatter within the reconstruction-with full pre-correction of the data being inferior compared to all the other methods, and the method which models scatter and attenuation within the system matrix showing some advantages. This work suggests that if regularisation of the EM algorithm is carried out by early termination of the iterative process, the subtraction method is the better approach among the techniques considered. In contrast, if a post-reconstruction smoothing approach to regularisation is to be used (whereby highly iterated, noisy image estimates are smoothed), the full modeling method for attenuation and scatter yields the better results, albeit at the computational cost of many more iterations being required
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5 (10823654) , 3022-3026
Region-based Efficiency Correction for the High-Resolution quad-HIDAC PET scanner
The very high resolution quad-HIDAC PET scanner has four detector banks each with four planar high density avalanche chambers, capable of collecting billions of lines-of-response (LORs), with very high spatial resolution, good absolute sensitivity and a large field of view (170 mm times 170 mm times 280 mm). However, it is crucial to correct for degrading factors introduced by the scanner's geometry and detection. A plane converter efficiency estimation method based on acceptance regions is presented, in which it is possible to represent a plane converter as a set of detection efficiency areas. LORs registered in a particular region in coincidence with another in the opposite plane converter are registered in a square array named a cooccurrence matrix, which is the basis of the method. The reciprocal of these factors are used as a multiplicative correction within the list-mode EM algorithm, event by event. A methodology to obtain the system-geometric correction factors is described and included within the reconstruction process as a normalisation component. Reconstructed images from a uniform 18F cylinder source (3 cm diameter, 5 cm length) and a 68Ge line source (15.5 cm length), were used to assess the region-efficiency and system-geometry correction.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5 (10823654) , 3022-3026
Region-based Efficiency Correction for the High-Resolution quad-HIDAC PET scanner
The very high resolution quad-HIDAC PET scanner has four detector banks each with four planar high density avalanche chambers, capable of collecting billions of lines-of-response (LORs), with very high spatial resolution, good absolute sensitivity and a large field of view (170 mm times 170 mm times 280 mm). However, it is crucial to correct for degrading factors introduced by the scanner's geometry and detection. A plane converter efficiency estimation method based on acceptance regions is presented, in which it is possible to represent a plane converter as a set of detection efficiency areas. LORs registered in a particular region in coincidence with another in the opposite plane converter are registered in a square array named a cooccurrence matrix, which is the basis of the method. The reciprocal of these factors are used as a multiplicative correction within the list-mode EM algorithm, event by event. A methodology to obtain the system-geometric correction factors is described and included within the reconstruction process as a normalisation component. Reconstructed images from a uniform 18F cylinder source (3 cm diameter, 5 cm length) and a 68Ge line source (15.5 cm length), were used to assess the region-efficiency and system-geometry correction.
- 1 December 1994
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 15 (12) , 998-999
8. High-resolution PET imaging of tumour using 18FDG
- 1 December 1994
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 15 (12) , 998-999
8. High-resolution PET imaging of tumour using 18FDG