Ana-Maria Bilawich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ana-Maria Bilawich has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- John R. Mayo
Department of Radiology, University of British Columbia, Vancouver, BC, Canada
2 shared publications Andrew Churg
Department of Pathology, Vancouver General Hospital and University of British Columbia, Vancouver, BC, Canada
1 shared publication- Chesnel Dey Arepalli
1081 Burrard Street, Vancouver, BC, V6Z 1Y6
1 shared publication Frith Coolbear
Department of Radiology, Vancouver General Hospital and University of British Columbia, Vancouver, BC, Canada
1 shared publicationJames Adamo
Pulmonary and Critical Care Service, Genesis HealthCare, Zanesville, OH, USA; Department of Internal Medicine, Ohio State University, Columbus, OH, USA
1 shared publication- John E. Aldrich
The University of British Columbia
1 shared publication
Latest Publications
- Open Access
- 1 January 2017
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 20, 195-197
Pleural amyloidosis imitating pleural malignancy
- 1 January 2017
- Published by Elsevier in Respiratory Medicine Case Reports
- Vol. 20, 195-197
Open AccessPleural amyloidosis imitating pleural malignancy
- 4 December 2015
- Published by Springer Nature in Emergency Radiology
- Vol. 23 (2) , 127-132
Dual-source CT in blunt trauma patients: elimination of diaphragmatic motion using high-pitch spiral technique
The purpose of this study was to compare diaphragmatic motion on dual-source high-pitch (DS-HP) and conventional single-source (SS) CT scans in trauma patients. Seventy-five consecutive trauma patients who presented to a level one trauma center over a 6-month period were scanned with a standardized whole body trauma CT protocol including both DS-HP chest (pitch = 2.1–2.5) and SS abdominal CT scans. Subjective analysis of diaphragmatic motion was performed by two readers using a four-point motion scale in seven regions of the diaphragm on coronal and axial slices. An overall confidence score to exclude a diaphragmatic tear was determined (1 to 10, 10: completely confident and 1: impossible to exclude). Wilcoxon rank sum tests were used for statistical analysis, and p < 0.05 was considered significant. Mean confidence score of 9.85 for DS-HP was significantly better than the mean score of 7.66 for SS images (p < 0.0001). Diaphragmatic motion scores and subjective diaphragmatic motion artifact on coronal and axial images were significantly better for DS-HP images in all areas when compared individually (p < 0.0001) and overall (p < 0.0001). Regions of DS-HP (99.2 %) were diagnostic, whereas only 87.0 % % regions on SS were. Complete agreement of motion scores was present in 92 % of cases, with moderate overall agreement for confidence to exclude a diaphragmatic tear (κ = 0.45). Dual-source high-pitch CT scanning is advantageous as it allows for significantly better evaluation of diaphragmatic structures by minimizing motion artifacts on images of freely breathing trauma patients.
- 4 December 2015
- Published by Springer Nature in Emergency Radiology
- Vol. 23 (2) , 127-132
Dual-source CT in blunt trauma patients: elimination of diaphragmatic motion using high-pitch spiral technique
The purpose of this study was to compare diaphragmatic motion on dual-source high-pitch (DS-HP) and conventional single-source (SS) CT scans in trauma patients. Seventy-five consecutive trauma patients who presented to a level one trauma center over a 6-month period were scanned with a standardized whole body trauma CT protocol including both DS-HP chest (pitch = 2.1–2.5) and SS abdominal CT scans. Subjective analysis of diaphragmatic motion was performed by two readers using a four-point motion scale in seven regions of the diaphragm on coronal and axial slices. An overall confidence score to exclude a diaphragmatic tear was determined (1 to 10, 10: completely confident and 1: impossible to exclude). Wilcoxon rank sum tests were used for statistical analysis, and p < 0.05 was considered significant. Mean confidence score of 9.85 for DS-HP was significantly better than the mean score of 7.66 for SS images (p < 0.0001). Diaphragmatic motion scores and subjective diaphragmatic motion artifact on coronal and axial images were significantly better for DS-HP images in all areas when compared individually (p < 0.0001) and overall (p < 0.0001). Regions of DS-HP (99.2 %) were diagnostic, whereas only 87.0 % % regions on SS were. Complete agreement of motion scores was present in 92 % of cases, with moderate overall agreement for confidence to exclude a diaphragmatic tear (κ = 0.45). Dual-source high-pitch CT scanning is advantageous as it allows for significantly better evaluation of diaphragmatic structures by minimizing motion artifacts on images of freely breathing trauma patients.
- 1 April 2006
- Vol. 57 (2) , 79-85
Radiation doses to patients receiving computed tomography examinations in British Columbia.
To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada. The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners. The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen-pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen-pelvis, 1100 mGy cm. Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany.
- 1 April 2006
- Vol. 57 (2) , 79-85
Radiation doses to patients receiving computed tomography examinations in British Columbia.
To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada. The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners. The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen-pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen-pelvis, 1100 mGy cm. Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany.