Ted Polglaze
Research Subjects
Ted Polglaze has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Brian Dawson
School of Human Sciences (Exercise and Sport Science), The University of Western Australia , Crawley, Western Australia
6 shared publications- Peter Peeling
School of Human Sciences (Exercise and Sport Science) The University of Western Australia Perth Australia
6 shared publications Alec Buttfield
College of Sport and Exercise Science, Victoria University, Melbourne, Australia
3 shared publications- Alec Buttfield
BioAlchemy , Adelaide, South Australia
1 shared publication Annette Bishop
Netball Singapore, Singapore, Singapore
1 shared publicationBenjamin M. Jackson
Sport Science, Exercise and Health. School of Human Sciences. The University of Western Australia, Crawley, Western Australia
1 shared publication
Latest Publications
- 15 April 2026
- Published by SAGE Publications in International Journal of Sports Science & Coaching
Influence of varying work and recovery durations and ratios on physical output in a simulated netball circuit
Recent rule changes in netball potentially allow coaches to maximise on-court work-rate and performance by adopting substitution strategies which minimise fatigue within, and optimise recovery between, playing stints. Thirteen female athletes from the Singapore National Netball Team performed three trials of a netball-specific simulation circuit with different combinations of work and recovery duration for each trial (Short – 8:2; Medium – 8:4; Long – 12:6). The circuit comprised a series of runs, jumps and netball-specific movements which replicate typical match demands. The time taken to complete each lap, along with sprint, agility and jump test performance within each lap, and physiological markers (heart rate, blood lactate, RPE, muscle oxygen saturation) were recorded. The Medium trial produced faster average lap times, 10 m sprint and agility times than the Short and Long trials, despite no differences in HR, BLa and RPE. The findings of this study demonstrate that manipulating the duration of work and recovery periods modifies player work rates for the same physiological burden. A W:R of 2:1, comprising an 8-min work duration accompanied by a 4-min rest period, was found to be optimal for maintenance of a high work rate in simulated netball activity.
- 15 April 2026
- Published by SAGE Publications in International Journal of Sports Science & Coaching
Influence of varying work and recovery durations and ratios on physical output in a simulated netball circuit
Recent rule changes in netball potentially allow coaches to maximise on-court work-rate and performance by adopting substitution strategies which minimise fatigue within, and optimise recovery between, playing stints. Thirteen female athletes from the Singapore National Netball Team performed three trials of a netball-specific simulation circuit with different combinations of work and recovery duration for each trial (Short – 8:2; Medium – 8:4; Long – 12:6). The circuit comprised a series of runs, jumps and netball-specific movements which replicate typical match demands. The time taken to complete each lap, along with sprint, agility and jump test performance within each lap, and physiological markers (heart rate, blood lactate, RPE, muscle oxygen saturation) were recorded. The Medium trial produced faster average lap times, 10 m sprint and agility times than the Short and Long trials, despite no differences in HR, BLa and RPE. The findings of this study demonstrate that manipulating the duration of work and recovery periods modifies player work rates for the same physiological burden. A W:R of 2:1, comprising an 8-min work duration accompanied by a 4-min rest period, was found to be optimal for maintenance of a high work rate in simulated netball activity.
- 20 March 2023
- Published by SAGE Publications in International Journal of Sports Science & Coaching
- Vol. 19 (1) , 353-354
Analysing the physical output of international field hockey players through the lens of phase of play: A Commentary
- 20 March 2023
- Published by SAGE Publications in International Journal of Sports Science & Coaching
- Vol. 19 (1) , 353-354
Analysing the physical output of international field hockey players through the lens of phase of play: A Commentary
- 24 June 2021
- Published by Taylor & Francis in International Journal of Performance Analysis in Sport
- Vol. 21 (5) , 790-803
Validity and reliability of a player-tracking device to identify movement orientation in team sports
The purpose of this study was to determine the validity and reliability of the GPExe pro2 device to identify movement orientation in team-sport locomotion. Part A involved a series of discrete movement tasks of varying direction and orientation at two speeds (walk, run); Part B involved a continuous Simulated Game Circuit (SGC). For validity, distance in each orientation quadrant (forward, backward, left, right) and two aggregated sectors (lateral, non-forward), was compared to the known distance and calculated as the standard error of estimate (SEE). Inter-unit reliability was assessed in the SGC and reported as typical error (TE) and coefficient of variation (CV). In total, 256 trials were collected for validity (Part A 232, Part B 24), and 17 trials for reliability. Validity improved with faster and more continuous movement (SEE: walk 6.2–8.7%; run 4.4–8.2%; SGC 1.0–6.2%), was better for forward and backward (1.0–2.8%) compared to left and right orientation (3.8–6.2%), and for aggregated sectors (2.4–5.1%) rather than specific quadrants. Reliability was good (CV10%) for left and right quadrants. These devices provide valid and reliable movement orientation data for team-sport locomotion, particularly in differentiating between forward and non-forward movement.
- 24 June 2021
- Published by Taylor & Francis in International Journal of Performance Analysis in Sport
- Vol. 21 (5) , 790-803
Validity and reliability of a player-tracking device to identify movement orientation in team sports
The purpose of this study was to determine the validity and reliability of the GPExe pro2 device to identify movement orientation in team-sport locomotion. Part A involved a series of discrete movement tasks of varying direction and orientation at two speeds (walk, run); Part B involved a continuous Simulated Game Circuit (SGC). For validity, distance in each orientation quadrant (forward, backward, left, right) and two aggregated sectors (lateral, non-forward), was compared to the known distance and calculated as the standard error of estimate (SEE). Inter-unit reliability was assessed in the SGC and reported as typical error (TE) and coefficient of variation (CV). In total, 256 trials were collected for validity (Part A 232, Part B 24), and 17 trials for reliability. Validity improved with faster and more continuous movement (SEE: walk 6.2–8.7%; run 4.4–8.2%; SGC 1.0–6.2%), was better for forward and backward (1.0–2.8%) compared to left and right orientation (3.8–6.2%), and for aggregated sectors (2.4–5.1%) rather than specific quadrants. Reliability was good (CV10%) for left and right quadrants. These devices provide valid and reliable movement orientation data for team-sport locomotion, particularly in differentiating between forward and non-forward movement.
- 15 February 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
- Vol. 236 (2) , 143-147
Placement of team sport GPS devices for reliability assessment
The goal of this study was to determine the effect of unit placement on signal integrity and measurement output obtained during reliability trials for global positioning system (GPS) devices. Two of the same model GPS units were worn in four separate unit configurations (Piggyback, Above-Below, Front-Back and Lateral) during 4 × 2 lap repeats of a team sport simulation circuit. Differences in signal integrity indicators (# satellites, horizontal dilution of precision (HDoP), signal-to-noise ratio (SNR) and signal strength (SS)), total distance covered in each lap, and distance covered above and below 3 m·s−1, were compared between the two units. The results showed that for signal integrity measures, differences between units were negligible for Above-Below and Lateral, but comparatively high for Piggyback and Front-Back. For distance measures, values were similar between units for Above-Below, however, discrepancies occurred in both total distance and speed distribution for the other configurations. This study concluded that the Above-Below unit configuration yielded the smallest differences between units for signal integrity and measurement output. Therefore, the Above-Below configuration is recommended for future GPS reliability investigations.
- 15 February 2021
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology
- Vol. 236 (2) , 143-147
Placement of team sport GPS devices for reliability assessment
The goal of this study was to determine the effect of unit placement on signal integrity and measurement output obtained during reliability trials for global positioning system (GPS) devices. Two of the same model GPS units were worn in four separate unit configurations (Piggyback, Above-Below, Front-Back and Lateral) during 4 × 2 lap repeats of a team sport simulation circuit. Differences in signal integrity indicators (# satellites, horizontal dilution of precision (HDoP), signal-to-noise ratio (SNR) and signal strength (SS)), total distance covered in each lap, and distance covered above and below 3 m·s−1, were compared between the two units. The results showed that for signal integrity measures, differences between units were negligible for Above-Below and Lateral, but comparatively high for Piggyback and Front-Back. For distance measures, values were similar between units for Above-Below, however, discrepancies occurred in both total distance and speed distribution for the other configurations. This study concluded that the Above-Below unit configuration yielded the smallest differences between units for signal integrity and measurement output. Therefore, the Above-Below configuration is recommended for future GPS reliability investigations.
- 16 June 2020
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 38 (19) , 2186-2192
Using the interaction of speed and acceleration to detect repeated-sprint activity in team sports
To compare the occurrence and characteristics of repeated-sprint (RS) activity in elite team sport competition when classified according to speed and/or acceleration, and their interaction via meta...
- 16 June 2020
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 38 (19) , 2186-2192
Using the interaction of speed and acceleration to detect repeated-sprint activity in team sports
To compare the occurrence and characteristics of repeated-sprint (RS) activity in elite team sport competition when classified according to speed and/or acceleration, and their interaction via meta...
- 3 September 2018
- Published by Taylor & Francis in International Journal of Performance Analysis in Sport
- Vol. 18 (5) , 823-834
A comparison of displacement and energetic variables between three team sport GPS devices
This study compared the outputs of three different commercially-available GPS player-tracking devices for a range of commonly used displacement and energetic variables in activities replicating team sport movements. Professional male soccer players (n = 7), simultaneously wore three GPS devices (Catapult OptimEye S5, GPExe Pro 1, StatSport ViperPod) whilst completing four separate drills, comprising progressively more complex changes in speed and direction. Displacement (distance, speed) and energetic (energy cost, metabolic power, energy expenditure) variables were compared for each device. All three devices tended to under-estimate distance compared to the known value for each drill, with only minor and inconsistent differences between devices. There were no differences between devices for average speed. For energetic variables, substantial differences were found between each device, and these differences magnified as movement tasks became more erratic. Given that energetic variables are derived from measures of instantaneous speed, and also incorporate the magnitude and direction of change between successive data points, these differences may be attributable to disparities in raw data quality, filtering techniques and calculation methods. In order to provide comparable estimates of energetic variables in team sports, player-tracking devices must be capable of accurately recording instantaneous velocity in activities comprising frequent changes in speed and direction.
- 3 September 2018
- Published by Taylor & Francis in International Journal of Performance Analysis in Sport
- Vol. 18 (5) , 823-834
A comparison of displacement and energetic variables between three team sport GPS devices
This study compared the outputs of three different commercially-available GPS player-tracking devices for a range of commonly used displacement and energetic variables in activities replicating team sport movements. Professional male soccer players (n = 7), simultaneously wore three GPS devices (Catapult OptimEye S5, GPExe Pro 1, StatSport ViperPod) whilst completing four separate drills, comprising progressively more complex changes in speed and direction. Displacement (distance, speed) and energetic (energy cost, metabolic power, energy expenditure) variables were compared for each device. All three devices tended to under-estimate distance compared to the known value for each drill, with only minor and inconsistent differences between devices. There were no differences between devices for average speed. For energetic variables, substantial differences were found between each device, and these differences magnified as movement tasks became more erratic. Given that energetic variables are derived from measures of instantaneous speed, and also incorporate the magnitude and direction of change between successive data points, these differences may be attributable to disparities in raw data quality, filtering techniques and calculation methods. In order to provide comparable estimates of energetic variables in team sports, player-tracking devices must be capable of accurately recording instantaneous velocity in activities comprising frequent changes in speed and direction.
- 1 September 2018
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 13 (8) , 1005-1010
Comparing Global Positioning System and Global Navigation Satellite System Measures of Team-Sport Movements
Purpose: To compare data from conventional global positioning system (GPS-) and new global navigation satellite system (GNSS-) enabled tracking devices and to examine the interunit reliability of GNSS devices. Methods: Interdevice differences between 10-Hz GPS and GNSS devices were examined during laps (n = 40) of a simulated game circuit and during elite hockey matches (n = 21); GNSS interunit reliability was also examined during laps of the simulated game circuit. Differences in distance values and measures in 3 velocity categories (low 5 m·s−1) and acceleration/deceleration counts (>1.46 and <−1.46 m·s−2) were examined using 1-way analysis of variance. Interunit GNSS reliability was examined using the coefficient of variation (CV) and intraclass correlation coefficient. Results: Interdevice differences (P < .05) were found for measures of peak deceleration, low-speed distance, percentage of total distance at low speed, and deceleration count during the simulated game circuit and for all measures except total distance and low-speed distance during hockey matches. Interunit (GNSS) differences (P < .05) were not found. The coefficient of variation was below 5% for total distance, average and peak speeds and distance and percentage of total distance of low-speed running. The GNSS devices had a lower horizontal dilution of precision score than GPS devices in all conditions. Conclusions: These findings suggest that GNSS devices may be more sensitive than GPS devices in quantifying the physical demands of team-sport movements, but further study into the accuracy of GNSS devices is required.
- 1 September 2018
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 13 (8) , 1005-1010
Comparing Global Positioning System and Global Navigation Satellite System Measures of Team-Sport Movements
Purpose: To compare data from conventional global positioning system (GPS-) and new global navigation satellite system (GNSS-) enabled tracking devices and to examine the interunit reliability of GNSS devices. Methods: Interdevice differences between 10-Hz GPS and GNSS devices were examined during laps (n = 40) of a simulated game circuit and during elite hockey matches (n = 21); GNSS interunit reliability was also examined during laps of the simulated game circuit. Differences in distance values and measures in 3 velocity categories (low 5 m·s−1) and acceleration/deceleration counts (>1.46 and <−1.46 m·s−2) were examined using 1-way analysis of variance. Interunit GNSS reliability was examined using the coefficient of variation (CV) and intraclass correlation coefficient. Results: Interdevice differences (P < .05) were found for measures of peak deceleration, low-speed distance, percentage of total distance at low speed, and deceleration count during the simulated game circuit and for all measures except total distance and low-speed distance during hockey matches. Interunit (GNSS) differences (P < .05) were not found. The coefficient of variation was below 5% for total distance, average and peak speeds and distance and percentage of total distance of low-speed running. The GNSS devices had a lower horizontal dilution of precision score than GPS devices in all conditions. Conclusions: These findings suggest that GNSS devices may be more sensitive than GPS devices in quantifying the physical demands of team-sport movements, but further study into the accuracy of GNSS devices is required.
- 1 July 2018
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 50 (7) , 1487-1494
Classification of Intensity in Team Sport Activity
Purpose This study aimed to assess the efficacy of critical metabolic power derived from variable-speed movement for classifying intensity in team sport activity. Methods Elite male hockey players (n = 12) completed a series of time trials (100 yards, 400 yards, 1500 yards) and a 3-min all-out test to derive both critical speed (CS) and critical power (CP). Heart rate (HR), blood lactate, and rating of perceived exertion were measured during each protocol. Participants (n = 10) then played two competitive hockey matches. Time spent greater than 85% of maximum HR was compared with time spent above CS (from the time trials) and CP (from the 3-min test). Results Between protocols, there was a moderate and nonsignificant association for CS (r = 0.359, P = 0.252) and a very large association for CP (r = 0.754, P = 0.005); the association was very large for peak HR (r = 0.866, P < 0.001), large for blood lactate (r = 0.506, P = 0.093), and moderate for rating of perceived exertion (rho = 0.441, P = 0.152). Time trials produced higher CS (4.3 vs 2.0 m·s−1, P < 0.001) and CP (18.3 vs 10.5 W·kg−1, P < 0.001) values than did the 3-min test. In matches, there was a very large association between time spent above 85% of maximum HR and time spent above both CS (r = 0.719, P < 0.001) and CP (r = 0.867, P < 0.001). This relationship was stronger for CP compared with CS (Z = 3.29, P = 0.0007). Conclusions Speed is not an appropriate parameter for the classification of team sport activity comprising continual changes in speed and direction; however, critical metabolic power derived from variable-speed activity seems useful for this purpose.
- 1 July 2018
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 50 (7) , 1487-1494
Classification of Intensity in Team Sport Activity
Purpose This study aimed to assess the efficacy of critical metabolic power derived from variable-speed movement for classifying intensity in team sport activity. Methods Elite male hockey players (n = 12) completed a series of time trials (100 yards, 400 yards, 1500 yards) and a 3-min all-out test to derive both critical speed (CS) and critical power (CP). Heart rate (HR), blood lactate, and rating of perceived exertion were measured during each protocol. Participants (n = 10) then played two competitive hockey matches. Time spent greater than 85% of maximum HR was compared with time spent above CS (from the time trials) and CP (from the 3-min test). Results Between protocols, there was a moderate and nonsignificant association for CS (r = 0.359, P = 0.252) and a very large association for CP (r = 0.754, P = 0.005); the association was very large for peak HR (r = 0.866, P < 0.001), large for blood lactate (r = 0.506, P = 0.093), and moderate for rating of perceived exertion (rho = 0.441, P = 0.152). Time trials produced higher CS (4.3 vs 2.0 m·s−1, P < 0.001) and CP (18.3 vs 10.5 W·kg−1, P < 0.001) values than did the 3-min test. In matches, there was a very large association between time spent above 85% of maximum HR and time spent above both CS (r = 0.719, P < 0.001) and CP (r = 0.867, P < 0.001). This relationship was stronger for CP compared with CS (Z = 3.29, P = 0.0007). Conclusions Speed is not an appropriate parameter for the classification of team sport activity comprising continual changes in speed and direction; however, critical metabolic power derived from variable-speed activity seems useful for this purpose.
- 9 February 2017
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 36 (2) , 140-148
Metabolic power and energy expenditure in an international men’s hockey tournament
The purpose of this study was to ascertain the typical metabolic power characteristics of elite men’s hockey, and whether changes occur within matches and throughout an international tournament. National team players (n = 16), divided into 3 positional groups (strikers, midfielders, defenders), wore Global Positioning System devices in 6 matches. Energetic (metabolic power, energy expenditure) and displacement (distance, speed, acceleration) variables were determined, and intensity was classified utilising speed, acceleration and metabolic power thresholds. Midfielder’s average metabolic power (11.8 ± 1.0 W · kg−1) was similar to strikers (11.1 ± 1.3 W · kg−1) and higher than defenders (10.8 ± 1.2 W · kg−1, P = 0.001). Strikers (29.71 ± 3.39 kJ · kg−1) expended less energy than midfielders (32.18 ± 2.67 kJ · kg−1, P = 0.014) and defenders (33.23 ± 3.96 kJ · kg−1, P < 0.001). Energetic variables did not change between halves or across matches. Across all positions, over 45% of energy expenditure was at high intensity (>20 W · kg−1). International hockey matches are intense and highly intermittent; however, intensity is maintained throughout matches and over a tournament. In isolation, displacement measures underestimate the amount of high-intensity activity, whereas the integration of instantaneous speed and acceleration provides a more comprehensive assessment of the demands for variable-speed activity typically occurring in hockey matches.
- 9 February 2017
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 36 (2) , 140-148
Metabolic power and energy expenditure in an international men’s hockey tournament
The purpose of this study was to ascertain the typical metabolic power characteristics of elite men’s hockey, and whether changes occur within matches and throughout an international tournament. National team players (n = 16), divided into 3 positional groups (strikers, midfielders, defenders), wore Global Positioning System devices in 6 matches. Energetic (metabolic power, energy expenditure) and displacement (distance, speed, acceleration) variables were determined, and intensity was classified utilising speed, acceleration and metabolic power thresholds. Midfielder’s average metabolic power (11.8 ± 1.0 W · kg−1) was similar to strikers (11.1 ± 1.3 W · kg−1) and higher than defenders (10.8 ± 1.2 W · kg−1, P = 0.001). Strikers (29.71 ± 3.39 kJ · kg−1) expended less energy than midfielders (32.18 ± 2.67 kJ · kg−1, P = 0.014) and defenders (33.23 ± 3.96 kJ · kg−1, P < 0.001). Energetic variables did not change between halves or across matches. Across all positions, over 45% of energy expenditure was at high intensity (>20 W · kg−1). International hockey matches are intense and highly intermittent; however, intensity is maintained throughout matches and over a tournament. In isolation, displacement measures underestimate the amount of high-intensity activity, whereas the integration of instantaneous speed and acceleration provides a more comprehensive assessment of the demands for variable-speed activity typically occurring in hockey matches.
- Open Access
- 28 November 2016
- Published by Swinburne University of Technology in Sensoria: A Journal of Mind, Brain and Culture
- Vol. 12 (2)
People, not technology, should drive innovation in elite sport
- 28 November 2016
- Published by Swinburne University of Technology in Sensoria: A Journal of Mind, Brain and Culture
- Vol. 12 (2)
Open AccessPeople, not technology, should drive innovation in elite sport