DHDaniel J. H. Henderson

Daniel J. H. Henderson

*This is an algorithmically generated author record based on publicly available information.

Daniel J. H. Henderson has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Human Shoulder Simulator for Cyclic Evaluation of Rotator Cuff Injury and Repair

    by Sophie Hutchinson, Peter Culmer, Claire Brockett, Dan Henderson, Paul Cowling, Sophie Williams

    Background/Objectives: Surgical repair of the rotator cuff tendons can lead to unsatisfactory results and the requirement for further surgical treatment. Development of repair techniques is limited by a lack of appropriate functional pre-clinical testing, especially over extended motion cycles. The purpose of this study was to demonstrate the efficacy of a novel shoulder simulator by assessing changes in internal muscle forces following a rotator cuff tear and double-row surgical repair. Methods: The developed shoulder simulator used motors to apply controlled movements/displacements to tendons (supraspinatus, infraspinatus, subscapularis, teres minor, anterior deltoid and middle deltoid) of a cadaveric human shoulder to produce cyclic abduction motion representative of normal shoulder function. The required displacement for each muscle was determined using a musculoskeletal model. The resultant force applied to each tendon during the cycles was measured using a compression load cell. Results: The developed simulator in this proof-of-concept study enabled the contribution of the different muscles involved in the shoulder during abduction to be assessed for the intact shoulder. The shoulder was also tested with a 50% supraspinatus tear and a double row surgical repair of the supraspinatus to assess the change in internal muscle forces. Conclusions: The study indicated that successful cyclic testing of cadaveric samples could be achieved using the simulator and changes in the internal muscle forces of the shoulder were identified following a supraspinatus tear and double-row surgical repair.

  • The V-shaped subscapularis tenotomy for anatomic total shoulder arthroplasty

    by Daniel J. H. Henderson, Thomas J. Christensen, Austin Vo, Johannes E. Plath, Ion-Andrei Popescu, Laurent Lafosse

    Purpose Management of the subscapularis tendon during anatomic total shoulder arthroplasty (TSA) remains controversial. In our unit, subscapularis tenotomy is the preferred technique; however, the potential for tendon gapping and failure is recognised. The purpose of this study is to describe and provide early clinical results of a novel, laterally based V-shaped tenotomy (VT) technique hypothesised to provide greater initial repair strength and resistance to gapping than a transverse tenotomy (TT), with both clinically and radiologically satisfactory post-operative tendon healing and function. Methods A retrospective study of patients who underwent primary TSA with VT over a three year period was performed using shoulder and subscapularis-specific outcome scores, radiographs, and ultrasound. A separate cohort of patients who underwent TSA using a subscapularis sparing approach was also reviewed to provide comparative clinical outcomes of a group with TSA and an un-violated subscapularis. Results Eighteen patients were reviewed at mean 30.4 months (± 11.7). Constant (78.2 ± 12.3), UCLA (8.4 ± 1.5), pain VAS (2.3 ± 2.8), and strength in internal rotation were no different from the comparison group. Likewise, neither were the clinical outcomes of range-of-motion, belly-press, lift-off, and shirt-tuck tests. One patient (5.5%) was found to have a failed subscapularis repair on ultrasound. Conclusion VT during TSA appears to provide healing rates at least equal to those reported for TT, and not dissimilar from those of lesser tuberosity osteotomy. Clinical outcomes are comparable to reported results in the literature for alternative techniques, and not different from those observed here in a comparison cohort with TSA performed without violating the subscapularis tendon. VT therefore potentially offers a more effective and secure tendon repair than a traditional TT, with at least comparable clinical outcomes.


  • Complications in Tendon Transfers

    by Daniel Henderson, Simon Boyle

  • Open Access

    Locking nail versus locking plate for proximal humeral fracture fixation in an elderly population: a prospective randomised controlled trial

    by Johannes E. Plath, Christian Kerschbaum, Tobias Seebauer, Rainer Holz, Daniel J. H. Henderson, Stefan Förch, Edgar Mayr

    Proximal humeral fractures (PHFs) are the third most common fracture in older patients. The purpose of the study was to prospectively evaluate the outcomes of PHF fixation with a locking blade nail (LBN) or locking plate (PHILOS) osteosynthesis in a homogeneous elderly patient population. Inclusion criteria were an age > 60 years and the capacity to give informed consent. Patients with isolated tuberosity fractures, previous trauma or surgery, advanced osteoarthritis, fracture dislocation, pathological fractures, open fractures, neurological disorders, full-thickness rotator cuff tears, fracture line at the nail entry point or severely reduced bone quality intra-operatively were excluded. Eighty one patients with PHFs were randomised to treatment using LBN or PHILOS. Outcome measures comprised Constant score, age and gender adjusted Constant score, DASH score, VAS for pain, subjective overall condition of the shoulder (1–6) and active shoulder range-of-motion in flexion and abduction. Plain radiographs were obtained in two planes. All data were collected by an independent observer at 3, 6 and 12 months postoperatively. Thirteen patients were excluded intra-operatively due to rotator cuff tears, fracture morphology or poor bone-quality. Of the remaining 68 patients, 27 in the LBN and 28 in the PHILOS group completed the full follow-up. Mean age at surgery was 75.6 years and the majority of PHFs were three-part fractures (49 patients). Baseline demographics between groups were comparable. All outcome measures improved between assessments (p < 0.001). The LBN group showed improved DASH scores as compared to PHILOS at 12 months (p = 0.042) with fewer incidences of secondary loss of reduction and screw cut-out (p = 0.039). A total of 29 complications (in 23 patients) were recorded, 13 complications (in 12 patients) in the LBN group and 16 complications (in 11 patients) in the PHILOS group (p = 0.941). No significant inter-group difference was observed for any other outcome measures, nor was fracture morphology seen to be associated with clinical outcome or complication rate. At short-term follow-up, LBN osteosynthesis yielded similar outcomes and complication rates to PHILOS plate fracture fixation in an elderly patient population, though with a significantly lower rate of secondary loss of reduction and screw cut-out. No. DRKS00015245 at Deutsches Register Klinischer Studien, registered: 22.08.2018, retrospectively registered.


  • Arthroscopic double bone block augmentation is a salvage procedure for anterior and posterior shoulder instability secondary to glenoid bone loss

    by David Haeni, Matthieu Sanchez, Plath Johannes, Lilling Victoria, Dan Henderson, Jeremy Munji, Kalojan Petkin, Laurent Lafosse

    The aim of this study was to describe a one-step arthroscopic anterior and posterior bone block augmentation technique for bidirectional shoulder instability and to present preliminary results.


  • Open Access

    An Arthroscopic Humeral Medializing Repair of the Supraspinatus

    by Amir Ghazanfari, Daniel J.H. Henderson, Geoffroy Nourissat

    Posterosuperior repair of the rotator cuff is one of the most frequently performed surgical procedures in the shoulder. Its aim is to fix the tendon back to the bone to restore anatomy, improve shoulder function, and prevent progression of cuff tear arthropathy and attendant muscle degeneration. Despite technical advances in this procedure, in some cases, the tendon cannot be fixed back to the footprint without excessive tension on the repair. In young patients or in patients with low‐grade muscle atrophy and fatty degeneration (Goutallier grade 1 or 2), it is mandatory to attempt fixation of the tendon to restore functional anatomy and prevent further muscle degeneration. In such cases, an arthroscopic medialized reinsertion of the supraspinatus may be considered. We describe an arthroscopic humeral medializing repair of the supraspinatus tendon that allows for a tension‐free repair of the supraspinatus using common portals and instruments. The goal of this technique is to obtain tendon healing, restore functional anatomy, and prevent atrophy and fatty degeneration of the muscles of the rotator cuff. Technique Video: video See video under supplementary data.


  • Does the Arthroscopic Latarjet Procedure Effectively Correct “Off-Track” Hill-Sachs Lesions?

    by Johannes E. Plath, Daniel J.H. Henderson, Julien Coquay, Klaus Dück, David Haeni, Laurent Lafosse

    The glenoid track concept describes the dynamic interaction of bipolar bone loss in anterior glenohumeral instability. Initial studies have successfully demonstrated this concept’s application in clinical populations. In clinical practice, the Latarjet procedure is commonly the preferred treatment in addressing “off-track” Hill-Sachs lesions. The effectiveness of this procedure in restoring such lesions to an “on-track” state, however, has not yet been evaluated or described in the literature. The Latarjet procedure would transform “off-track” Hill-Sachs lesions to “on-track” lesions. Lesions would remain “on-track” during follow-up, despite glenoid remodeling. Case series; Level of evidence, 4. Patients with “off-track” Hill-Sachs lesions treated with the arthroscopic Latarjet procedure between March 2013 and May 2014 were included. Glenoid track and coracoid graft contact surface area measurements using 3-dimensional computed tomography (3D-CT) were performed preoperatively and at 6-week, 6-month, and at least 12-month (final) follow-up. The mean final follow-up was 23 months. The glenoid diameter, as a percentage of the native glenoid, was also calculated from this imaging. Twenty-six patients met the inclusion criteria. 3D-CT scans were available for all patients preoperatively and postoperatively, with 21 patients (81%) undergoing 6-month follow-up CT and 19 patients (73%) undergoing final follow-up CT. Hill-Sachs lesions remained “on-track” at all follow-up time points. The mean glenoid diameter changed significantly from 84.6% preoperatively to 122.8% at 6 weeks (P < .001) and from 120.5% at 6 months to 113.9% at final follow-up (P = .005). This was also reflected in significant remodeling seen in the coracoid graft articular contact area (6 weeks to 6 months, P = .024; 6 months to final follow-up, P = .002). This persisting glenoid arc enlargement at final follow-up avoided “off-track” Hill-Sachs lesions in 6 of 19 patients (32%), which would otherwise have occurred had the coracoid graft remodeled to native glenoid dimensions. The Latarjet procedure provides an effective treatment for “off-track” engaging Hill-Sachs lesions, despite an evident glenoid remodeling process. At a mean of 23 months postoperatively, a mean persisting enlargement of the glenoid arc of 14% beyond native dimensions remained, avoiding a recurrent “off-track” lesion in 32% of patients, which would otherwise have occurred with complete remodeling.


  • What Are the Biomechanical Properties of the Taylor Spatial Frame™?

    by Daniel J. Henderson, Jeremy L. Rushbrook, Paul J. Harwood, Todd D. Stewart

    The Taylor Spatial Frame™ (TSF) is a versatile variant of the traditional Ilizarov circular fixator. Although in widespread use, little comparative data exist to quantify the biomechanical effect of substituting the tried-and-tested Ilizarov construct for the TSF hexapod system. This study was designed to investigate the mechanical properties of the TSF system under physiologic loads, with and without the addition of a simulated bone model, with comparison to the standard Ilizarov frame. The mechanical behaviors of three identical four-ring TSF and Ilizarov constructs were tested under levels of axial compression, bending, and rotational torque to simulate loading during normal gait. An acrylic-pipe fracture model subsequently was mounted, using fine wires and 5 mm half pins, and the testing was repeated. Load-deformation curves, and so rigidity, for each construct were calculated, with statistical comparisons performed using paired t-tests. Under axial loading, the TSF was found to be less rigid than the Ilizarov frame (645 ± 57 N/mm versus 1269 ± 256 N/mm; mean difference, 623 N/mm; 95% CI, 438.3–808.5 N/mm; p < 0.001), but more rigid under bending and torsional loads (bending: 42 ± 9 Nm/degree versus 78 ± 13 Nm/degree; mean difference, 37 Nm/degree; 95% CI, 25.0–47.9 Nm/degree; p < 0.001; torsion: 16 ± 2 Nm/degree versus 5 ± 0.35 Nm/degree; mean difference, 11 Nm/degree; 95% CI, 9.5–12.2 Nm/degree; p < 0.001). On mounting the bone models, these relationships broadly remained in the half-pin and fine-wire groups, however the half-pin constructs were universally more rigid than those using fine wires. This effect resulted in the TSF, using half pins, showing no difference in axial rigidity to the fine-wire Ilizarov (107 ± 3 N/mm versus 107 ± 4 N/mm; mean difference, 0.05 N/mm; 95% CI, −6.99 to 7.1 N/mm; p > 0.999), while retaining greater bending and torsional rigidity. Throughout testing, a small amount of laxity was observed in the TSF construct on either side of neutral loading, amounting to 0.72 mm (±0.37 mm) for a change in loading between −10 N and 10 N axial load, and which persisted with the addition of the synthetic fracture model. This study broadly shows the TSF construct to generate lower axial rigidity, but greater bending and torsional rigidity, when compared with the Ilizarov frame, under physiologic loads. The anecdotally described laxity in the TSF hexapod strut system was shown in vitro, but only at low levels of loading around neutral. It also was shown that the increased stiffness generated by use of half pins produced a TSF construct replicating the axial rigidity of a fine-wire Ilizarov frame, for which much evidence of good clinical and radiologic outcomes exist, while providing greater rigidity and so improved resistance to potentially detrimental bending and rotational shear loads. If replicated in the clinical setting, these findings suggest that when using the TSF, care should be taken to minimize the observed laxity around neutral with appropriate preloading of the construct, but that its use may produce constructs better able to resist bending and torsional loading, although with lower axial rigidity. Use of half pins in a TSF construct however may replicate the axial mechanical behavior of an Ilizarov construct, which is thought to be conducive to bone healing.


  • Open Access

    What Are the Biomechanical Effects of Half-pin and Fine-wire Configurations on Fracture Site Movement in Circular Frames?

    by Daniel J. Henderson, Jeremy L. Rushbrook, Todd D. Stewart, Paul J. Harwood

    Fine-wire circular frame (Ilizarov) fixators are hypothesized to generate favorable biomechanical conditions for fracture healing, allowing axial micromotion while limiting interfragmentary shear. Use of half-pins increases fixation options and may improve patient comfort by reducing muscle irritation, but they are thought to induce interfragmentary shear, converting beam-to-cantilever loading. Little evidence exists regarding the magnitude and type of strain in such constructs during weightbearing.


  • Functional Outcomes After Tibial Shaft Fractures Treated Using the Taylor Spatial Frame

    by Daniel J. MBChB Henderson, Elizabeth Bsc(Hons) Barron, Yvonne Hadland, Hemant K. Frcs (Orth) Sharma

    Objectives: To analyze functional and radiologic outcomes of tibial shaft fractures treated with the Taylor spatial frame (TSF). Design: Prospective follow-up study of radiologic and functional outcomes. Setting: University teaching hospital. Patients: From January 2006 to December 2012, prospective data were collected for 56 consecutive patients completing treatment of a tibial shaft fracture with the TSF. Intervention: Treatment of tibial shaft fractures, including those with simple extension into the knee or ankle joints, using the TSF. Main Outcome Measurements: Residual deformity on x-ray and functional outcomes using the EQ-5D health status questionnaire, Iowa Knee and Ankle Evaluation Rating System scores, and Olerud and Molander Ankle score were recorded 1 year after frame removal. Results: Average residual deformity was 1.8 degrees in the coronal and 1.6 degrees in the sagittal planes. EQ-5D outcomes showed patients returning to a health status no different from scores for the UK population as a whole. Iowa Knee scores demonstrated “good” or “excellent” outcomes in 87.3% of our cohort (mean, 90). Ankle Evaluation Rating System scores and Olerud and Molander Ankle scores showed “good” or “excellent” outcomes in 76.8% and 89.3% of our cohort, respectively (mean, 84.1 and 84). Conclusions: Use of the TSF for treatment of tibial fractures, with support from a dedicated limb reconstruction rehabilitation team, has a number of technical advantages while producing good functional and surgical outcomes, with patients recovering to a pre-injury health status. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.