Tingting Gang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tingting Gang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Manli Hu
Physics Department, Northwest University, No. 229, Taibai Road (North), Xi’an 710069, China
3 shared publications - Qiangzhou Rong
Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA
3 shared publications - Xiaohong Bai
Carleton Univ, Dept Elect, Ottawa, ON K1S 5B6, Canada
2 shared publications Binghan Fu
Xian Shiyou Univ, Sch Sci, Xian 710065, Peoples R China
1 shared publicationCe Bian
Xian Inst Electromech Informat Technol, Xian 710065, Peoples R China
1 shared publication- Ce Bian
Tianjin Tianke Intelligent Manufacture Technology Co., LTD
1 shared publication
Latest Publications
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4618-4622
A Novel Strain Sensor Using a Fiber Taper Cascaded With an Air Bubble Based on Fabry–Perot Interferometer
A novel optical fiber strain sensor based on a Fabry–Perot Interferometer (FPI) is proposed and experimentally demonstrated. The FPI is fabricated by splicing a single mode fiber (SMF) taper and an air micro-bubble formed by using repeated discharging on the hollow core fiber (HCF). By doing this, the sensitivity of the proposed configuration to strain is greatly increased comparing with that of other FPIs. Experimental results show that the sensitivity of the sensor to strain can reach 41.5 pm/με, 42.56 pm/με and 41.02 pm/με at the dips of 1525.9721 nm, 1646.3134 nm and 1567.1797 nm, respectively with negligible power fluctuation. And average sensitivity at three resonance peaks to temperature is 2.04 pm/°C resulting the temperature cross sensitivity of 0.0489 με/°C. In addition, the proposed sensor shows good performances in the repeatability and stability, which can be potentially used in the many fields such as medical treatment and structural health monitoring.
- 21 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (4) , 4618-4622
A Novel Strain Sensor Using a Fiber Taper Cascaded With an Air Bubble Based on Fabry–Perot Interferometer
A novel optical fiber strain sensor based on a Fabry–Perot Interferometer (FPI) is proposed and experimentally demonstrated. The FPI is fabricated by splicing a single mode fiber (SMF) taper and an air micro-bubble formed by using repeated discharging on the hollow core fiber (HCF). By doing this, the sensitivity of the proposed configuration to strain is greatly increased comparing with that of other FPIs. Experimental results show that the sensitivity of the sensor to strain can reach 41.5 pm/με, 42.56 pm/με and 41.02 pm/με at the dips of 1525.9721 nm, 1646.3134 nm and 1567.1797 nm, respectively with negligible power fluctuation. And average sensitivity at three resonance peaks to temperature is 2.04 pm/°C resulting the temperature cross sensitivity of 0.0489 με/°C. In addition, the proposed sensor shows good performances in the repeatability and stability, which can be potentially used in the many fields such as medical treatment and structural health monitoring.
- Open Access
Sensitivity-Improved Ultrasonic Sensor for 3D Imaging of Seismic Physical Model Using a Compact Microcavity
A sensitivity-improved ultrasonic sensor is proposed and demonstrated experimentally in this present study. The device is comprised only a fiber-optic microcavity that is formed by discharging a short section of hollow core fiber (HCF). The key to ensuring the success of the sensor relies on the preprocessing of hydrogen loading for HCF. When discharging the HCF, the hydrogen is heated up during the formation of the air bubble, which enlarges the bubble diameter, smoothens its surfaces simultaneously and decreases Young’s modulus of the material of the bubble. Ultimately, this results in the probe being highly sensitive to ultrasound with a SNR of 69.28 dB. Once the compact air cavity is formed between the end face of the leading-in fiber and the top wall of the bubble, a well-defined interference spectrum is achieved based on the Fabry–Perot interference. By using spectral side-band filtering technology, we detect the ultrasonic waves reflected by the seismic physical model (SMF) and then reconstruct its three-dimensional image.
Open AccessSensitivity-Improved Ultrasonic Sensor for 3D Imaging of Seismic Physical Model Using a Compact Microcavity
A sensitivity-improved ultrasonic sensor is proposed and demonstrated experimentally in this present study. The device is comprised only a fiber-optic microcavity that is formed by discharging a short section of hollow core fiber (HCF). The key to ensuring the success of the sensor relies on the preprocessing of hydrogen loading for HCF. When discharging the HCF, the hydrogen is heated up during the formation of the air bubble, which enlarges the bubble diameter, smoothens its surfaces simultaneously and decreases Young’s modulus of the material of the bubble. Ultimately, this results in the probe being highly sensitive to ultrasound with a SNR of 69.28 dB. Once the compact air cavity is formed between the end face of the leading-in fiber and the top wall of the bubble, a well-defined interference spectrum is achieved based on the Fabry–Perot interference. By using spectral side-band filtering technology, we detect the ultrasonic waves reflected by the seismic physical model (SMF) and then reconstruct its three-dimensional image.
- Open Access
A Submerged Optical Fiber Ultrasonic Sensor Using Matched Fiber Bragg Gratings
A novel kind of fiber optic ultrasonic sensor based on matching fiber Bragg gratings (FBGs) is proposed and demonstrated. The sensors consist of a pair of matching FBGs fixed to a special bracket. The bracket plays a role in stretching and squeezing the FBGs, with the push–pull effect efficiently coupling the ultrasonic signal to the sensor, thus, improving the sensor’s sensitivity. Side-band filtering technology-based intensity interrogation was used to detect ultrasounds in water. With the synergic effect of the matching FBGs, the sensor performed with a high signal-to-noise ratio (56.9 dB at 300 KHz, 53 dB at 1 MHz and 31.8 dB at 5 MHz) and the observed ultrasonic sinusoidal signals were undistorted and distinguishable in the time domain.
Open AccessA Submerged Optical Fiber Ultrasonic Sensor Using Matched Fiber Bragg Gratings
A novel kind of fiber optic ultrasonic sensor based on matching fiber Bragg gratings (FBGs) is proposed and demonstrated. The sensors consist of a pair of matching FBGs fixed to a special bracket. The bracket plays a role in stretching and squeezing the FBGs, with the push–pull effect efficiently coupling the ultrasonic signal to the sensor, thus, improving the sensor’s sensitivity. Side-band filtering technology-based intensity interrogation was used to detect ultrasounds in water. With the synergic effect of the matching FBGs, the sensor performed with a high signal-to-noise ratio (56.9 dB at 300 KHz, 53 dB at 1 MHz and 31.8 dB at 5 MHz) and the observed ultrasonic sinusoidal signals were undistorted and distinguishable in the time domain.
- Open Access
High-Frequency Fiber-Optic Ultrasonic Sensor Using Air Micro-Bubble for Imaging of Seismic Physical Models
A micro-fiber-optic Fabry-Perot interferometer (FPI) is proposed and demonstrated experimentally for ultrasonic imaging of seismic physical models. The device consists of a micro-bubble followed by the end of a single-mode fiber (SMF). The micro-structure is formed by the discharging operation on a short segment of hollow-core fiber (HCF) that is spliced to the SMF. This micro FPI is sensitive to ultrasonic waves (UWs), especially to the high-frequency (up to 10 MHz) UW, thanks to its ultra-thin cavity wall and micro-diameter. A side-band filter technology is employed for the UW interrogation, and then the high signal-to-noise ratio (SNR) UW signal is achieved. Eventually the sensor is used for lateral imaging of the physical model by scanning UW detection and two-dimensional signal reconstruction.
Open AccessHigh-Frequency Fiber-Optic Ultrasonic Sensor Using Air Micro-Bubble for Imaging of Seismic Physical Models
A micro-fiber-optic Fabry-Perot interferometer (FPI) is proposed and demonstrated experimentally for ultrasonic imaging of seismic physical models. The device consists of a micro-bubble followed by the end of a single-mode fiber (SMF). The micro-structure is formed by the discharging operation on a short segment of hollow-core fiber (HCF) that is spliced to the SMF. This micro FPI is sensitive to ultrasonic waves (UWs), especially to the high-frequency (up to 10 MHz) UW, thanks to its ultra-thin cavity wall and micro-diameter. A side-band filter technology is employed for the UW interrogation, and then the high signal-to-noise ratio (SNR) UW signal is achieved. Eventually the sensor is used for lateral imaging of the physical model by scanning UW detection and two-dimensional signal reconstruction.