Richard F. Ff. Weir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Richard F. Ff. Weir has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Douglas A. Kerns
Sigenics Inc., Sierra Madre, CA 91024 USA
2 shared publications - Glenn A. DeMichele
Sigenics Inc., Lincolnshire, IL 60069, USA
2 shared publications - Jonathon W. Sensinger
Northwestern University, Evanston, IL 60208 USA. phone: 312-238-6500
2 shared publications - Philip R. Troyk
Sigenics Inc., Lincolnshire, IL 60069 USA
2 shared publications - Bradley Greger
School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, United States
1 shared publication C W Heckathorne
1 shared publication
Latest Publications
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (9) , 2198-2211
A Comparison of the Effects of Electrode Implantation and Targeting on Pattern Classification Accuracy for Prosthesis Control
The use of surface versus intramuscular electrodes as well as the effect of electrode targeting on pattern-recognition- based multifunctional prosthesis control was explored. Surface electrodes are touted for their ability to record activity from relatively large portions of muscle tissue. Intramuscular electromyograms (EMGs) can provide focal recordings from deep muscles of the forearm and independent signals relatively free of crosstalk. However, little work has been done to compare the two. Additionally, while previous investigations have either targeted electrodes to specific muscles or used untargeted (symmetric) electrode arrays, no work has compared these approaches to determine if one is superior. The classification accuracies of pattern-recognition-based classifiers utilizing surface and intramuscular as well as targeted and untargeted electrodes were compared across 11 subjects. A repeated-measures analysis of variance revealed that when only EMG amplitude information was used from all available EMG channels, the targeted surface, targeted intramuscular, and untargeted surface electrodes produced similar classification accuracies while the untargeted intramuscular electrodes produced significantly lower accuracies. However, no statistical differences were observed between any of the electrode conditions when additional features were extracted from the EMG signal. It was concluded that the choice of electrode should be driven by clinical factors, such as signal robustness/stability, cost, etc., instead of by classification accuracy.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (9) , 2198-2211
A Comparison of the Effects of Electrode Implantation and Targeting on Pattern Classification Accuracy for Prosthesis Control
The use of surface versus intramuscular electrodes as well as the effect of electrode targeting on pattern-recognition- based multifunctional prosthesis control was explored. Surface electrodes are touted for their ability to record activity from relatively large portions of muscle tissue. Intramuscular electromyograms (EMGs) can provide focal recordings from deep muscles of the forearm and independent signals relatively free of crosstalk. However, little work has been done to compare the two. Additionally, while previous investigations have either targeted electrodes to specific muscles or used untargeted (symmetric) electrode arrays, no work has compared these approaches to determine if one is superior. The classification accuracies of pattern-recognition-based classifiers utilizing surface and intramuscular as well as targeted and untargeted electrodes were compared across 11 subjects. A repeated-measures analysis of variance revealed that when only EMG amplitude information was used from all available EMG channels, the targeted surface, targeted intramuscular, and untargeted surface electrodes produced similar classification accuracies while the untargeted intramuscular electrodes produced significantly lower accuracies. However, no statistical differences were observed between any of the electrode conditions when additional features were extracted from the EMG signal. It was concluded that the choice of electrode should be driven by clinical factors, such as signal robustness/stability, cost, etc., instead of by classification accuracy.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 193-196
Decoding individuated finger flexions with Implantable MyoElectric Sensors
We trained a rhesus monkey to perform randomly cued, individuated finger flexions of the thumb, index, and middle finger. Nine Implantable MyoElectric Sensors (IMES) were then surgically implanted into the finger muscles of the monkey's forearm, without any observable adverse chronic effects. Using an inductive link, we wirelessly recorded EMG from the IMES as the monkey performed a finger flexion task. A principal components analysis (PCA) based algorithm was used to decode which finger switch was pressed based on the recorded EMG. This algorithm correctly decoded which finger was moved 89% of the time. These results demonstrate that IMES offer a safe and highly promising approach for providing intuitive, dexterous control of artificial limbs and hands after amputation.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 193-196
Decoding individuated finger flexions with Implantable MyoElectric Sensors
We trained a rhesus monkey to perform randomly cued, individuated finger flexions of the thumb, index, and middle finger. Nine Implantable MyoElectric Sensors (IMES) were then surgically implanted into the finger muscles of the monkey's forearm, without any observable adverse chronic effects. Using an inductive link, we wirelessly recorded EMG from the IMES as the monkey performed a finger flexion task. A principal components analysis (PCA) based algorithm was used to decode which finger switch was pressed based on the recorded EMG. This algorithm correctly decoded which finger was moved 89% of the time. These results demonstrate that IMES offer a safe and highly promising approach for providing intuitive, dexterous control of artificial limbs and hands after amputation.
- 3 April 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 16 (2) , 184-190
Modeling and Preliminary Testing Socket-Residual Limb Interface Stiffness of Above-Elbow Prostheses
The interface between the socket and residual limb can have a significant effect on the performance of a prosthesis. Specifically, knowledge of the rotational stiffness of the socket-residual limb (S-RL) interface is extremely useful in designing new prostheses and evaluating new control paradigms, as well as in comparing existing and new socket technologies. No previous studies, however, have examined the rotational stiffness of S-RL interfaces. To address this problem, a math model is compared to a more complex finite element analysis, to see if the math model sufficiently captures the main effects of S-RL interface rotational stiffness. Both of these models are then compared to preliminary empirical testing, in which a series of X-rays, called fluoroscopy, is taken to obtain the movement of the bone relative to the socket. Force data are simultaneously recorded, and the combination of force and movement data are used to calculate the empirical rotational stiffness of elbow S-RL interface. The empirical rotational stiffness values are then compared to the models, to see if values of Young's modulus obtained in other studies at localized points may be used to determine the global rotational stiffness of the S-RL interface. Findings include agreement between the models and empirical results and the ability of persons to significantly modulate the rotational stiffness of their S-RL interface a little less than one order of magnitude. The floor and ceiling of this range depend significantly on socket length and co-contraction levels, but not on residual limb diameter or bone diameter. Measured trans-humeral S-RL interface rotational stiffness values ranged from 24-140 Nm/rad for the four subjects tested in this study.
- 3 April 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 16 (2) , 184-190
Modeling and Preliminary Testing Socket-Residual Limb Interface Stiffness of Above-Elbow Prostheses
The interface between the socket and residual limb can have a significant effect on the performance of a prosthesis. Specifically, knowledge of the rotational stiffness of the socket-residual limb (S-RL) interface is extremely useful in designing new prostheses and evaluating new control paradigms, as well as in comparing existing and new socket technologies. No previous studies, however, have examined the rotational stiffness of S-RL interfaces. To address this problem, a math model is compared to a more complex finite element analysis, to see if the math model sufficiently captures the main effects of S-RL interface rotational stiffness. Both of these models are then compared to preliminary empirical testing, in which a series of X-rays, called fluoroscopy, is taken to obtain the movement of the bone relative to the socket. Force data are simultaneously recorded, and the combination of force and movement data are used to calculate the empirical rotational stiffness of elbow S-RL interface. The empirical rotational stiffness values are then compared to the models, to see if values of Young's modulus obtained in other studies at localized points may be used to determine the global rotational stiffness of the S-RL interface. Findings include agreement between the models and empirical results and the ability of persons to significantly modulate the rotational stiffness of their S-RL interface a little less than one order of magnitude. The floor and ceiling of this range depend significantly on socket length and co-contraction levels, but not on residual limb diameter or bone diameter. Measured trans-humeral S-RL interface rotational stiffness values ranged from 24-140 Nm/rad for the four subjects tested in this study.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 4359-4360
New Multifunctional Prosthetic Arm and hand Systems
We are building a new hand with 18 DOF which has all its actuators inside the body of the hand. This hand is in a form suitable for the 50% women but has the strength capabilities of a 50% male.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 4359-4360
New Multifunctional Prosthetic Arm and hand Systems
We are building a new hand with 18 DOF which has all its actuators inside the body of the hand. This hand is in a form suitable for the 50% women but has the strength capabilities of a 50% male.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 2970-2973
An Implantable Myoelectric Sensor Based Prosthesis Control System
We present progress on the design and testing of an upper-extremity prosthesis control system based on implantable myoelectric sensors. The implant consists of a single silicon chip packaged with transmit and receive coils. Forward control telemetry to, and reverse EMG data telemetry from multiple implants has been demonstrated
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 2970-2973
An Implantable Myoelectric Sensor Based Prosthesis Control System
We present progress on the design and testing of an upper-extremity prosthesis control system based on implantable myoelectric sensors. The implant consists of a single silicon chip packaged with transmit and receive coils. Forward control telemetry to, and reverse EMG data telemetry from multiple implants has been demonstrated
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 2970-2973
An Implantable Myoelectric Sensor Based Prosthesis Control System
We present progress on the design and testing of an upper-extremity prosthesis control system based on implantable myoelectric sensors. The implant consists of a single silicon chip packaged with transmit and receive coils. Forward control telemetry to, and reverse EMG data telemetry from multiple implants has been demonstrated
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 2970-2973
An Implantable Myoelectric Sensor Based Prosthesis Control System
We present progress on the design and testing of an upper-extremity prosthesis control system based on implantable myoelectric sensors. The implant consists of a single silicon chip packaged with transmit and receive coils. Forward control telemetry to, and reverse EMG data telemetry from multiple implants has been demonstrated
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Improvements to Series Elastic Actuators
Actuators must be safe when interacting with humans, even in unexpected situations. Safety requires low impedance (low forces for a given perturbation) at all frequencies, not only in the actuator's stable bandwidth. Series elastic actuators (SEAs) are capable of achieving low impedance across all frequencies, though their force-frequency saturation envelope is decreased as a result. This paper examines ways to increase the force fidelity of SEAs by introducing inner control feedback loops and using appropriate sensor location. Findings include the superiority of a low fidelity sensor distal to stiction sources over a high fidelity sensor proximal to stiction and the superiority of an inner position feedback loop over an inner velocity feedback loop
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Improvements to Series Elastic Actuators
Actuators must be safe when interacting with humans, even in unexpected situations. Safety requires low impedance (low forces for a given perturbation) at all frequencies, not only in the actuator's stable bandwidth. Series elastic actuators (SEAs) are capable of achieving low impedance across all frequencies, though their force-frequency saturation envelope is decreased as a result. This paper examines ways to increase the force fidelity of SEAs by introducing inner control feedback loops and using appropriate sensor location. Findings include the superiority of a low fidelity sensor distal to stiction sources over a high fidelity sensor proximal to stiction and the superiority of an inner position feedback loop over an inner velocity feedback loop
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Unconstrained Impedance Control Using a Compact Series Elastic Actuator
Series elastic actuators offer high fidelity force control with inherent low impedance above their controllable frequency bandwidth. As a result they well suited for interaction with humans, in which safety is paramount. Their high force fidelity suggests that they may be a suitable for impedance control, in which the interaction between motion and force is controlled. The authors model the unconstrained actuator, and perform tests to evaluate the ability of series elastic actuators to mimic different stiffness. Series elastic actuators are found to be adequate for unconstrained impedance control at input frequencies below 3 Hz
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Unconstrained Impedance Control Using a Compact Series Elastic Actuator
Series elastic actuators offer high fidelity force control with inherent low impedance above their controllable frequency bandwidth. As a result they well suited for interaction with humans, in which safety is paramount. Their high force fidelity suggests that they may be a suitable for impedance control, in which the interaction between motion and force is controlled. The authors model the unconstrained actuator, and perform tests to evaluate the ability of series elastic actuators to mimic different stiffness. Series elastic actuators are found to be adequate for unconstrained impedance control at input frequencies below 3 Hz
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005 (1094687X) , 7337-7340
Technical Details of the Implantable Myoelectric Sensor (IMES) System for Multifunction Prosthesis Control
The limitation of current prostheses is not the devices themselves but rather the lack of sufficient independent control sources. A system capable of reading intra muscular EMG signals would greatly increase the number control sources available for prosthesis control. We are developing a multichannel/multifunction prosthetic hand/arm controller system capable of receiving and processing signals from up to sixteen implanted bipolar differential electromyographic (EMG) electrodes. An external prosthesis controller will decipher user intent from telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link will provide power for the implanted electrodes. This paper describes some of the technical aspects of the implant and telemetry design
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2005 (1094687X) , 7337-7340
Technical Details of the Implantable Myoelectric Sensor (IMES) System for Multifunction Prosthesis Control
The limitation of current prostheses is not the devices themselves but rather the lack of sufficient independent control sources. A system capable of reading intra muscular EMG signals would greatly increase the number control sources available for prosthesis control. We are developing a multichannel/multifunction prosthetic hand/arm controller system capable of receiving and processing signals from up to sixteen implanted bipolar differential electromyographic (EMG) electrodes. An external prosthesis controller will decipher user intent from telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link will provide power for the implanted electrodes. This paper describes some of the technical aspects of the implant and telemetry design
- 27 August 2003
- Published by SAGE Publications in Technology and Disability
- Vol. 15 (2) , 113-127
A two degree-of-freedom microprocessor based extended physiological proprioception (EPP) controller for upper limb prostheses
A two degree-of-freedom microprocessor based controller that uses the principle of Extended Physiological Proprioception (EPP), was designed for the simultaneous multifunctional control of upper-limb prostheses. In an EPP system, the output is relate
- 27 August 2003
- Published by SAGE Publications in Technology and Disability
- Vol. 15 (2) , 113-127
A two degree-of-freedom microprocessor based extended physiological proprioception (EPP) controller for upper limb prostheses
A two degree-of-freedom microprocessor based controller that uses the principle of Extended Physiological Proprioception (EPP), was designed for the simultaneous multifunctional control of upper-limb prostheses. In an EPP system, the output is relate