DSDavid Schilling

David Schilling

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Schilling has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Utilization of surgical safety checklists by urological surgeons in Germany: a nationwide prospective survey

    by Hendrik Borgmann, Sarah Helbig, Michael A. Reiter, Tanja Hüsch, David Schilling, Igor Tsaur, Axel Haferkamp

    We aimed to investigate the contemporary usage rate and habits of the WHO Surgical Safety Checklist (SSC) in German urological departments. We designed a 26-item questionnaire that was sent to all urological departments in Germany. The primary aim of this study was to evaluate the usage rate of the SSC. Secondary aims were to compare perioperative characteristics of users vs. non-users of the SSC and to assess circumstances of the SSC application. A total of 213 of 234 (91 %) urological departments were users of the SSC, and 21 (9 %) were non-users. SSC users had more often a standard protocol, took less time and had fewer people involved for checking perioperative patient data compared to non-users. Financial budgeting for the SSC existed in 55 (24 %) departments and for patient safety in 73 (32 %) departments. The usage rate of the SSC in urological departments in Germany is high despite restricted financial budgeting. Users of the SSC profit by saving time and manpower for checking perioperative patient data.


  • The hydrodynamic basis of the vacuum cleaner effect in continuous-flow PCNL instruments: an empiric approach and mathematical model

    by R. Mager, C. Balzereit, K. Gust, T. Hüsch, T. Herrmann, U. Nagele, A. Haferkamp, D. Schilling

    Purpose Passive removal of stone fragments in the irrigation stream is one of the characteristics in continuous-flow PCNL instruments. So far the physical principle of this so-called vacuum cleaner effect has not been fully understood yet. The aim of the study was to empirically prove the existence of the vacuum cleaner effect and to develop a physical hypothesis and generate a mathematical model for this phenomenon. Methods In an empiric approach, common low-pressure PCNL instruments and conventional PCNL sheaths were tested using an in vitro model. Flow characteristics were visualized by coloring of irrigation fluid. Influence of irrigation pressure, sheath diameter, sheath design, nephroscope design and position of the nephroscope was assessed. Experiments were digitally recorded for further slow-motion analysis to deduce a physical model. Results In each tested nephroscope design, we could observe the vacuum cleaner effect. Increase in irrigation pressure and reduction in cross section of sheath sustained the effect. Slow-motion analysis of colored flow revealed a synergism of two effects causing suction and transportation of the stone. For the first time, our model showed a flow reversal in the sheath as an integral part of the origin of the stone transportation during vacuum cleaner effect. The application of Bernoulli’s equation provided the explanation of these effects and confirmed our experimental results. Conclusions We widen the understanding of PCNL with a conclusive physical model, which explains fluid mechanics of the vacuum cleaner effect.


  • Evaluation of the ‘Prostate Interdisciplinary Communication and Mapping Algorithm for Biopsy and Pathology’ (PIC-MABP)

    by Daniel Junker, the Training Research in Urological Surgery Therapy (T.R.U.S.T.) group, Thomas R. W. Herrmann, Markus Bader, Jasmin Bektic, Gregor Henkel, Stephan Kruck, Markus Sandbichler, David Schilling, Georg Schäfer, et al.

    Experience from interdisciplinary cooperation revealed the need for a prostate mapping scheme to communicate multiparametric MRI (mpMRI) findings between radiologists, urologists, and pathologists, which should be detailed, yet easy to memorize. For this purpose, the ‘Prostate interdisciplinary communication and mapping algorithm for biopsy and pathology’ (PIC-MABP) was developed. This study evaluated the accuracy of the PIC-MABP system. PIC-MABP was tested and validated in findings of 10 randomly selected patients from routine clinical practise with 18 histologically proven cancer lesions. Patients received an mpMRI of the prostate prior to prostatectomy. After surgery the prostates were prepared as whole-mount step sections. Cancer lesions, which were found suspicious on mpMRI, were assigned to the according PIC-MABP sectors by a radiologist. MpMRI slides were masked and sent to seven urologists from different centres, providing only the PIC-MABP location of each lesion. Urologists marked the accordant regions. Then mpMRI slides were unmasked, and the correctness of each mark was evaluated. One hundred and seventeen of the 126 marks (93 %) were correctly assigned. Detection rates differed for lesions >0.5 cc compared with lesions p < 0.005): 3/7 (43 %) marks were correctly assigned in lesions 0.5 cc. Interobserver agreement was good for lesions >0.5 cc and poor for lesions 0.5 cc between different disciplines and can be a useful guidance for cognitive mpMRI/TRUS fusion biopsy.