Kishan Bellur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kishan Bellur has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Chang Kyoung Choi
Department of Mechanical Engineering-Engineering Mechanics, Michigan Technological University, Houghton, MI 49931, USA
5 shared publications - Daniel Seth Hussey
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD, USA
5 shared publications - David L. Jacobson
National Institute of Standards and Technology, Gaithersburg, MD, USA
5 shared publications - Jeffrey S. Allen
Michigan Technological University
5 shared publications - Amirhosein Sarchami
Department of Mechanical and Materials Engineering
4 shared publications - Ayaaz Yasin
Department of Mechanical and Materials Engineering
4 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Kinetic origin of the accommodation coefficient inequality in liquid–vapor phase change
Liquid–vapor phase change transports large quantities of heat with little temperature rise, making it central to the thermal management of high-power electronics, two-phase cooling, and cryogenic systems. The rate of phase change is commonly described by the kinetic-theory-based Hertz–Knudsen–Schrage equation, in which two coefficients scale the evaporation and condensation fluxes, representing the fractions of molecules that cross the interface. These coefficients are the dominant source of uncertainty in phase change models. Reported values span several orders of magnitude, and for simplicity the two coefficients are commonly assumed equal, without sufficient supporting evidence. We show that this assumption of equality fails under net phase change and establish the physical origin of the deviation. Further, we derive an expression for the evaporation coefficient and pair it with transition state theory for the condensation coefficient, so the Hertz–Knudsen–Schrage equation predicts the phase change rate with no tuned inputs. The results are validated by molecular dynamics simulations of an argon-filled platinum nanochannel that directly measure fluxes using particle tracking. Simulations and theory show that the inequality grows in proportion to the net phase change flux. While negligible near equilibrium, the inequality becomes large enough that assuming equal coefficients or perfect accommodation mispredicts the mass flux by about a factor of two as the heat flux approaches 3500 W/cm², the peak heat flux of high-performance electronics and AI-hardware cooling. Accounting for this inequality is therefore essential in high-flux applications, and the expressions derived here provide a tuning-free way to do so.
- 20 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessKinetic origin of the accommodation coefficient inequality in liquid–vapor phase change
Liquid–vapor phase change transports large quantities of heat with little temperature rise, making it central to the thermal management of high-power electronics, two-phase cooling, and cryogenic systems. The rate of phase change is commonly described by the kinetic-theory-based Hertz–Knudsen–Schrage equation, in which two coefficients scale the evaporation and condensation fluxes, representing the fractions of molecules that cross the interface. These coefficients are the dominant source of uncertainty in phase change models. Reported values span several orders of magnitude, and for simplicity the two coefficients are commonly assumed equal, without sufficient supporting evidence. We show that this assumption of equality fails under net phase change and establish the physical origin of the deviation. Further, we derive an expression for the evaporation coefficient and pair it with transition state theory for the condensation coefficient, so the Hertz–Knudsen–Schrage equation predicts the phase change rate with no tuned inputs. The results are validated by molecular dynamics simulations of an argon-filled platinum nanochannel that directly measure fluxes using particle tracking. Simulations and theory show that the inequality grows in proportion to the net phase change flux. While negligible near equilibrium, the inequality becomes large enough that assuming equal coefficients or perfect accommodation mispredicts the mass flux by about a factor of two as the heat flux approaches 3500 W/cm², the peak heat flux of high-performance electronics and AI-hardware cooling. Accounting for this inequality is therefore essential in high-flux applications, and the expressions derived here provide a tuning-free way to do so.
- Open Access
- 28 April 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (20) , 14045-14059
An Experimental Study of Interfacial Dynamics Control Using Temperature-Sensitive Surfactants
The dynamic control of meniscus curvature is a fundamental aspect of interfacial science with broad implications for microfluidics, thermal management, and adaptive surface technologies. Here, we investigate the temperature-induced interfacial dynamics of menisci in oil–water systems containing thermoresponsive surfactants. Using high-resolution bright-field microscopy, we systematically examine the effects of temperature-sensitive surfactants, concentration, capillary geometry, temporal temperature gradients, contact angle hysteresis, and heat transfer direction (heating/cooling) on meniscus displacement, contact angle, and interfacial tension. Our results demonstrate that the combination of C18TAB in water and hexadecanol in hexadecane enables reversible and tunable switching between concave and convex meniscus shapes, with the transition temperature (Tt) strongly dependent on surfactant composition and concentration. A unique thermal hysteresis in contact angle is observed and is attributed to the asymmetric adsorption/desorption kinetics and interfacial freezing, which is amplified in wider capillaries. However, temporal temperature gradients within the tested range have minimal influence on curvature switching, indicating quasi-static interfacial equilibration at supra-CMC concentrations. These findings establish a framework for actively manipulating interfacial geometry, providing design principles for programmable and reversible wettability control in interfacial systems.
- 28 April 2026
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 42 (20) , 14045-14059
Open AccessAn Experimental Study of Interfacial Dynamics Control Using Temperature-Sensitive Surfactants
The dynamic control of meniscus curvature is a fundamental aspect of interfacial science with broad implications for microfluidics, thermal management, and adaptive surface technologies. Here, we investigate the temperature-induced interfacial dynamics of menisci in oil–water systems containing thermoresponsive surfactants. Using high-resolution bright-field microscopy, we systematically examine the effects of temperature-sensitive surfactants, concentration, capillary geometry, temporal temperature gradients, contact angle hysteresis, and heat transfer direction (heating/cooling) on meniscus displacement, contact angle, and interfacial tension. Our results demonstrate that the combination of C18TAB in water and hexadecanol in hexadecane enables reversible and tunable switching between concave and convex meniscus shapes, with the transition temperature (Tt) strongly dependent on surfactant composition and concentration. A unique thermal hysteresis in contact angle is observed and is attributed to the asymmetric adsorption/desorption kinetics and interfacial freezing, which is amplified in wider capillaries. However, temporal temperature gradients within the tested range have minimal influence on curvature switching, indicating quasi-static interfacial equilibration at supra-CMC concentrations. These findings establish a framework for actively manipulating interfacial geometry, providing design principles for programmable and reversible wettability control in interfacial systems.
- Open Access
A Multiscale CFD Model of Evaporating Hydrogen Menisci: Incorporating Subgrid Thin-Film Dynamics and In Situ Accommodation Coefficients
Due to its high energy density, liquid Hydrogen is an essential fuel for both terrestrial energy systems and space propulsion. However, uncontrolled evaporation poses a challenge for cryogenic storage and transport technologies. Accurate modeling of evaporation remains difficult due to the multiscale menisci formed by the wetting liquid phase. Thin liquid films form near the walls of containers, ranging from millimeters to nanometers in thickness. Heat conduction through the solid walls enables high evaporation rates in this region. Discrepancies in the reported values of the accommodation coefficients (necessary inputs to models) further complicate evaporation calculations. In this study, we present a novel multiscale model for CFD simulations of evaporating Hydrogen menisci. Film profiles below 10 m are computed by a subgrid model using a lubrication-type thin film equation. The microscale model is combined with a macroscale model above 10 m. Evaporation rates are computed using a kinetic phase change model combined with in situ calculations of the accommodation coefficient using transition state theory. The submodels are implemented in Ansys FluentTM using User-Defined Functions (UDFs), and a method to establish two-way coupling is detailed. The modeling results are in good agreement with cryo-neutron experiments and show improvement over prior models. The model, including UDFs, is made available through a public repository.Open AccessA Multiscale CFD Model of Evaporating Hydrogen Menisci: Incorporating Subgrid Thin-Film Dynamics and In Situ Accommodation Coefficients
Due to its high energy density, liquid Hydrogen is an essential fuel for both terrestrial energy systems and space propulsion. However, uncontrolled evaporation poses a challenge for cryogenic storage and transport technologies. Accurate modeling of evaporation remains difficult due to the multiscale menisci formed by the wetting liquid phase. Thin liquid films form near the walls of containers, ranging from millimeters to nanometers in thickness. Heat conduction through the solid walls enables high evaporation rates in this region. Discrepancies in the reported values of the accommodation coefficients (necessary inputs to models) further complicate evaporation calculations. In this study, we present a novel multiscale model for CFD simulations of evaporating Hydrogen menisci. Film profiles below 10 m are computed by a subgrid model using a lubrication-type thin film equation. The microscale model is combined with a macroscale model above 10 m. Evaporation rates are computed using a kinetic phase change model combined with in situ calculations of the accommodation coefficient using transition state theory. The submodels are implemented in Ansys FluentTM using User-Defined Functions (UDFs), and a method to establish two-way coupling is detailed. The modeling results are in good agreement with cryo-neutron experiments and show improvement over prior models. The model, including UDFs, is made available through a public repository. - Open Access
- 15 October 2025
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 728
A computational model for pore-scale flow regime tuning with thermally responsive surfactants
- 15 October 2025
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 728
Open AccessA computational model for pore-scale flow regime tuning with thermally responsive surfactants
- Open Access
- 28 May 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 276
Computational modeling of evaporation without tuning coefficients
- 28 May 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 276
Open AccessComputational modeling of evaporation without tuning coefficients
- Open Access
- 23 January 2025
- Published by Springer Nature in Discover Mechanical Engineering
- Vol. 4 (1) , 1-20
Hydraulic micromotor powered dissector for minimally invasive therapy
- 23 January 2025
- Published by Springer Nature in Discover Mechanical Engineering
- Vol. 4 (1) , 1-20
Open AccessHydraulic micromotor powered dissector for minimally invasive therapy
- 1 January 2025
- Published by Begell House Inc. Publishers in Journal of Flow Visualization and Image Processing
- Vol. 32 (2) , 107-126
CHARACTERIZING OPTICAL TRANSMISSION THROUGH SESSILE WATER DROPLETS UNDERGOING SOLIDIFICATION
The current increase in the usage of solar panels in cold-weather climates requires a comprehensive understanding of droplet freezing. Freezing dynamics of a water droplet resting on a hydrophobic surface is well understood, but changes in optical transmission during this process have not received much attention. As the droplet freezes, its refractive index and the shape change simultaneously. Here, an attempt is made to characterize the change in optical transmission during the freezing process using a unique setup that allows for bidirectional imaging of a droplet as it undergoes freezing on coated glass slides. This allows for phase change dynamics to be decoupled from the change in droplet geometry. There is a 45% reduction in optical transmission during the freezing process, but this is primarily due to reflection and not attenuation. The droplet geometry is observed to influence a change in optical transmission due to changes in both reflection and attenuation. Common hydrophobic coatings are tested, and their influence on the optical transmission is characterized. The results of this study provide new insight in the development of optically transparent ice/water repellent coatings for solar panels.
- 1 January 2025
- Published by Begell House Inc. Publishers in Journal of Flow Visualization and Image Processing
- Vol. 32 (2) , 107-126
CHARACTERIZING OPTICAL TRANSMISSION THROUGH SESSILE WATER DROPLETS UNDERGOING SOLIDIFICATION
The current increase in the usage of solar panels in cold-weather climates requires a comprehensive understanding of droplet freezing. Freezing dynamics of a water droplet resting on a hydrophobic surface is well understood, but changes in optical transmission during this process have not received much attention. As the droplet freezes, its refractive index and the shape change simultaneously. Here, an attempt is made to characterize the change in optical transmission during the freezing process using a unique setup that allows for bidirectional imaging of a droplet as it undergoes freezing on coated glass slides. This allows for phase change dynamics to be decoupled from the change in droplet geometry. There is a 45% reduction in optical transmission during the freezing process, but this is primarily due to reflection and not attenuation. The droplet geometry is observed to influence a change in optical transmission due to changes in both reflection and attenuation. Common hydrophobic coatings are tested, and their influence on the optical transmission is characterized. The results of this study provide new insight in the development of optically transparent ice/water repellent coatings for solar panels.
- 3 September 2024
- Published by Wiley in Journal of Turbomachinery
- Vol. 147 (1) , 1-36
Lessons Learned From Pandemic-Driven Remote Learning and Sustaining Best Practices in Turbomachinery Laboratory Experiences
As online educational experiences have become more common for students to engage with while earning an engineering degree, instructors must become more attuned to best practices in digital pedagogies for all courses, including those with heavy laboratory components. Despite potential resistance among faculty to the idea that a laboratory course does not require an in-person experience, pandemic-driven remote learning serves as an intrinsic data point in how, under dire circumstances, laboratory courses could be offered through a digital medium. This paper describes a collaborative autoethnography of four mechanical and aerospace engineering instructors regarding lessons learned while teaching laboratory courses online during the COVID-19 pandemic. To bolster the quality of the research design, an engineering education researcher facilitated the collaborative autoethnography and co-constructed the individual instructor narratives to elicit best practices in online pedagogy for turbomachinery educators.
- 3 September 2024
- Published by Wiley in Journal of Turbomachinery
- Vol. 147 (1) , 1-36
Lessons Learned From Pandemic-Driven Remote Learning and Sustaining Best Practices in Turbomachinery Laboratory Experiences
As online educational experiences have become more common for students to engage with while earning an engineering degree, instructors must become more attuned to best practices in digital pedagogies for all courses, including those with heavy laboratory components. Despite potential resistance among faculty to the idea that a laboratory course does not require an in-person experience, pandemic-driven remote learning serves as an intrinsic data point in how, under dire circumstances, laboratory courses could be offered through a digital medium. This paper describes a collaborative autoethnography of four mechanical and aerospace engineering instructors regarding lessons learned while teaching laboratory courses online during the COVID-19 pandemic. To bolster the quality of the research design, an engineering education researcher facilitated the collaborative autoethnography and co-constructed the individual instructor narratives to elicit best practices in online pedagogy for turbomachinery educators.
- Open Access
- 12 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 131
Scaling a Hydraulic Motor for Minimally Invasive Medical Devices
Aligned with the medical device industry’s trend of miniaturization, academic and commercial researchers are constantly attempting to reduce device sizes. Many applications require miniature actuators (2 mm range) to perform mechanical work; however, biocompatible micromotors are not readily available. To that end, a hydraulic motor-driven cutting module that aims to combine cutting and drug delivery is presented. The hydraulic motor prototype developed has an outside diameter (OD) of ~4 mm (twice the target size) and a 1 mm drive shaft to attach a cutter. Four different designs were explored and fabricated using additive manufacturing. The benchtop experimental data of the prototypes are presented herein. For the prototype motor with fluid inlet perpendicular to the blades, the average angular velocity was 10,593 RPM at a flowrate of 3.6 mL/s and 42,597 RPM at 10.1 mL/s. This design was numerically modeled using 3D-transient simulations in ANSYS CFX (version 2022 R2) to determine the performance characteristics and the internal resistance of the motor. Simplified mathematical models were also used to compute and compare the peak torque with the simulation estimates. The viability of current design represents a crucial milestone in scaling the hydraulic motor to a 2 mm OD to power a microcutter.
- 12 January 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (1) , 131
Open AccessScaling a Hydraulic Motor for Minimally Invasive Medical Devices
Aligned with the medical device industry’s trend of miniaturization, academic and commercial researchers are constantly attempting to reduce device sizes. Many applications require miniature actuators (2 mm range) to perform mechanical work; however, biocompatible micromotors are not readily available. To that end, a hydraulic motor-driven cutting module that aims to combine cutting and drug delivery is presented. The hydraulic motor prototype developed has an outside diameter (OD) of ~4 mm (twice the target size) and a 1 mm drive shaft to attach a cutter. Four different designs were explored and fabricated using additive manufacturing. The benchtop experimental data of the prototypes are presented herein. For the prototype motor with fluid inlet perpendicular to the blades, the average angular velocity was 10,593 RPM at a flowrate of 3.6 mL/s and 42,597 RPM at 10.1 mL/s. This design was numerically modeled using 3D-transient simulations in ANSYS CFX (version 2022 R2) to determine the performance characteristics and the internal resistance of the motor. Simplified mathematical models were also used to compute and compare the peak torque with the simulation estimates. The viability of current design represents a crucial milestone in scaling the hydraulic motor to a 2 mm OD to power a microcutter.
- Open Access
- 14 November 2023
- Published by Frontiers Media SA in Frontiers in Space Technologies
- Vol. 4, 1263496
An investigation of phase change induced Marangoni-dominated flow patterns using the Constrained Vapor Bubble data from ISS experiments
Kinetic models of liquid-vapor phase change often implicitly assume that the interface is in equilibrium. This equilibrium assumption can be justified for large flat interfaces far from the source of thermal energy, but it breaks down when the liquid surface is near a solid wall, or there is significant interface curvature. The Constrained Vapor Bubble (CVB) experiments conducted on the International Space Station (ISS) provide a unique opportunity to probe this common assumption and also provide unique data and insight into phase change-driven flow physics. The CVB experiment consists of a quartz cuvette partially filled with pentane such that a vapor bubble is formed at the center. The setup is heated and cooled at opposite ends, resulting in simultaneous evaporation and condensation. CVB data from the NASA Physical Science Informatics (PSI) database was used to reconstruct the entire 3D interface shape using interferometric image analysis and obtain an estimate of the net heat input to the bubble. The reconstructed interface shape is used to develop a liquid-only CFD model embedded with a custom-built ``active surface'' method that sets a variable interfacial temperature/phase change flux boundary condition. Phase change flux varies in both the axial and transverse directions, leading to a small ($\sim$1 K) but discernible temperature variation along the liquid-vapor interface. The positive phase change flux near the heater end (denoting evaporation) gradually reduces and becomes negative near the cooler end (denoting condensation), resulting in an axial bulk flow of liquid from the cold to the hot end. There is also a higher flux in the thin film as opposed to the thick film, resulting in a transverse bulk flow. However, the interfacial temperature gradients along both axial and transverse directions induce a separate thermocapillary flow in a direction opposite to the bulk flows, leading to complex “wavy” flows with recirculation. A qualitative analysis of the flow pattern is presented in this paper and correlated with optical signatures from experimental images.
- 14 November 2023
- Published by Frontiers Media SA in Frontiers in Space Technologies
- Vol. 4, 1263496
Open AccessAn investigation of phase change induced Marangoni-dominated flow patterns using the Constrained Vapor Bubble data from ISS experiments
Kinetic models of liquid-vapor phase change often implicitly assume that the interface is in equilibrium. This equilibrium assumption can be justified for large flat interfaces far from the source of thermal energy, but it breaks down when the liquid surface is near a solid wall, or there is significant interface curvature. The Constrained Vapor Bubble (CVB) experiments conducted on the International Space Station (ISS) provide a unique opportunity to probe this common assumption and also provide unique data and insight into phase change-driven flow physics. The CVB experiment consists of a quartz cuvette partially filled with pentane such that a vapor bubble is formed at the center. The setup is heated and cooled at opposite ends, resulting in simultaneous evaporation and condensation. CVB data from the NASA Physical Science Informatics (PSI) database was used to reconstruct the entire 3D interface shape using interferometric image analysis and obtain an estimate of the net heat input to the bubble. The reconstructed interface shape is used to develop a liquid-only CFD model embedded with a custom-built ``active surface'' method that sets a variable interfacial temperature/phase change flux boundary condition. Phase change flux varies in both the axial and transverse directions, leading to a small ($\sim$1 K) but discernible temperature variation along the liquid-vapor interface. The positive phase change flux near the heater end (denoting evaporation) gradually reduces and becomes negative near the cooler end (denoting condensation), resulting in an axial bulk flow of liquid from the cold to the hot end. There is also a higher flux in the thin film as opposed to the thick film, resulting in a transverse bulk flow. However, the interfacial temperature gradients along both axial and transverse directions induce a separate thermocapillary flow in a direction opposite to the bulk flows, leading to complex “wavy” flows with recirculation. A qualitative analysis of the flow pattern is presented in this paper and correlated with optical signatures from experimental images.