Amadou Diop
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amadou Diop has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Nathalie Maurel
2 shared publicationsD. Lemosse
Laboratoire de biomécanique, École nationale supérieure d'arts et métiers, Paris, France
1 shared publicationEtienne Patoor
1 shared publicationF. Lavaste
Laboratoire de Biomécanique, Ecole Nationale Supérieure d’Arts et Métiers, 151, Boulevard de l’Hôpital, F-75013 Paris, France Tel. +33-1-44 24 63 64; Fax +33-1-44 24 63 66
1 shared publication- Jean Grimberg
Institut de Recherche en Chirurgie Orthopédique et Sportive (IRCOS), 6 Avenue Alphonse XIII, 75016, Paris, France.
1 shared publication Jean Kany
1 shared publication
Latest Publications
- 1 November 2011
- Published by Elsevier in Clinical Biomechanics
- Vol. 26 (9) , 904-909
Tendon fixation in arthroscopic latissimus dorsi transfer for irreparable posterosuperior cuff tears: An in vitro biomechanical comparison of interference screw and suture anchors
- 1 November 2011
- Published by Elsevier in Clinical Biomechanics
- Vol. 26 (9) , 904-909
Tendon fixation in arthroscopic latissimus dorsi transfer for irreparable posterosuperior cuff tears: An in vitro biomechanical comparison of interference screw and suture anchors
- 1 April 2009
- Published by Elsevier in Journal of Endodontics
- Vol. 35 (4) , 568-572
A Novel Platform for In Vitro Analysis of Torque, Forces, and Three-dimensional File Displacements During Root Canal Preparations: Application to ProTaper Rotary Files
- 1 April 2009
- Published by Elsevier in Journal of Endodontics
- Vol. 35 (4) , 568-572
A Novel Platform for In Vitro Analysis of Torque, Forces, and Three-dimensional File Displacements During Root Canal Preparations: Application to ProTaper Rotary Files
- 27 February 1998
- Published by Springer Nature in European Spine Journal
- Vol. 7 (1) , 16-23
Characterization of the mechanical behaviour parameters of the costo-vertebral joint
This in vitro study introduces a new method to determine quantitative parameters characterizing the mechanical behaviour of the costo-vertebral joint. These parameters are useful in building numerical models of the thoracic spine, taking into account the thoracic cage. Nine thoracic cages were isolated from fresh human cadavers. From each cage, three functional units were tested: T1–T2, T5–T6, T9–T10. Loads were applied according to the joint local coordinate system. Every functional unit was tested first intact and again after section of successive costo-transverse ligaments. We used an opto-electronic system to follow the three-dimensional motion of the joint, and obtained non-linear load/displacement curves according to the primary rotation axis. A statistical analysis of these curves allowed the calculation of parameters describing the joint mechanical behaviour: total range of motion, motion in the low-stiffness zone, and flexibilities in the positive and negative quasi-linear zones. These values can be used as a database for mechanical modeling of the spine.
- 27 February 1998
- Published by Springer Nature in European Spine Journal
- Vol. 7 (1) , 16-23
Characterization of the mechanical behaviour parameters of the costo-vertebral joint
This in vitro study introduces a new method to determine quantitative parameters characterizing the mechanical behaviour of the costo-vertebral joint. These parameters are useful in building numerical models of the thoracic spine, taking into account the thoracic cage. Nine thoracic cages were isolated from fresh human cadavers. From each cage, three functional units were tested: T1–T2, T5–T6, T9–T10. Loads were applied according to the joint local coordinate system. Every functional unit was tested first intact and again after section of successive costo-transverse ligaments. We used an opto-electronic system to follow the three-dimensional motion of the joint, and obtained non-linear load/displacement curves according to the primary rotation axis. A statistical analysis of these curves allowed the calculation of parameters describing the joint mechanical behaviour: total range of motion, motion in the low-stiffness zone, and flexibilities in the positive and negative quasi-linear zones. These values can be used as a database for mechanical modeling of the spine.