SGSaba A. Gheni

Saba A. Gheni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Saba A. Gheni has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigation of carbon dioxide (CO2) capture in a falling film contactor by computer simulation

    by Saba A. Gheni, Mohammed F. Abed, Essam K. Halabia, Saad R. Ahmed

    In this work, mathematical models of carbon dioxide (CO2) absorption by monoethanolamine amine (MEA) in a falling film contactor are developed. The proposed models aim to predict conversion of the gas liquid reaction along the contactor, gas liquid interface temperature profile (axial and radial), liquid film thickness along the contactor length, axial and radial concentration profiles of reactants in liquid film, and axial and radial profiles of velocity in the liquid film. A code written in MatLab was used to obtain these profiles based on multi grid method through programming of kinetic and thermodynamic equations and physical properties of the absorption system. The mathematical model is validated by an experimental measurement based on absorption of CO2 gas by MEA solution. Four parameters are studied as independent variables namely, mole fraction of carbon dioxide in gaseous mixture, molar concentration of absorbent (MEA, volumetric flow rate of MEA, and its temperature. It is found that the entrance effect of the falling film contactor is related to axial distance from the contactor entrance exponentially: E = B(0)exp(-B(1)y) An optimization technique based on minimization of the sum of the squared error between the experimental and predicted composition of absorption process is used to obtain B-0 and B-1. It is found that reaction between carbon dioxide and MEA is instantaneous, and the axial conversion of carbon dioxide in the gas phase varies exponentially with the contactor length.


  • Study of the Hydrodynamics and Mass Transfer Coefficient in a 2D Mimicked FT Slurry Bubble Columns for Alternative Clean Energy and Chemical Production

    by Hiba A. Abdulkareem, Saba A. Gheni, Rafi’ J. Yacoup

    Bubble columns are widely used for contacting gas–liquid and gas–liquid–solid mass transfer/chemical reactions. Gas distributor is the most important accessory because it decides the bubble size/rise velocity and gas distribution. In this study, the effect of distributor design on hydrodynamics and mass transfer coefficient are studied at different operating conditions of height to diameter ratio, solid loading, and superficial gas velocity The overall gas holdup, is studied experimentally using a rectangular slurry bubble column operating at ambient temperature and pressure, using liquid paraffin (C 9 –C 11 ), three heights to diameter ratios (6, 7.5 and 10) and silica as a solid phase (0 %, 9 % and 25 %) with oxygen as gas phase. Two types of distributor were used, perforated plate and ring type. The results showed that the overall gas holdup increased by increasing gas velocity and decreased by increasing height to diameter ratio and solid loading. Also, it is found that the perforated plate distributor gave a higher gas hold up than ring distributor at gas velocity higher than 0.03 m/sec. The following correlations are obtained: Plate distributor at presence of silica particles: ε g = 1.343 U g 0.0612 − 0.00891 ε s − 0.374 − 0.702 L D 0.041 4.904 − 0.0251 $$\eqalign{{{\rm{\varepsilon}}_{\rm{g}}} =& {\left({1.343{\rm{U}}_{\rm{g}}^{0.0612} - 0.00891{\rm{\varepsilon}}_{\rm{s}}^{- 0.374} - 0.702{{\left({{{\rm{L}} \over {\rm{D}}}} \right)}^{0.041}}} \right)^{4.904}}\cr& - 0.0251}$$ Ring distributor at presence and absence of silica particles: ε g = 0.216 U g 0.297 − 0.354 ε s 1.4671 − 0.127 L D 0.147 1.1206 + 0.058 $$\eqalign{{{\rm{\varepsilon}}_{\rm{g}}} = &{\left({0.216{\rm{U}}_{\rm{g}}^{0.297} - 0.354{\rm{\varepsilon}}_{\rm{s}}^{1.4671} - 0.127{{\left({{{\rm{L}} \over {\rm{D}}}} \right)}^{0.147}}} \right)^{1.1206}} \cr&+ 0.058}$$ There is a good agreement between experimental and predicted values with a percent of error less than 2 %. It has been found that the mass transfer coefficient is higher for ring distributor than the perforated plate and growing higher for heterogeneous flow regime and higher solid loading.


  • Effect of L/D Ratio on Phase Holdup and Bubble Dynamics in Slurry Bubble Column using Optical Fiber Probe Measurements

    by Saba A. Gheni, Yasser I. Abdulaziz, Muthanna H. Al-Dahhan

    In this investigation, time average local gas holdup and bubble dynamic data were achieved for three L/D ratios of slurry bubble column. The examined ratios were 3, 4 and 5 in 18″ diameter slurry bubble column. Air-water-glass bead system was used with superficial gas velocity up to 0.24 m/s. The gas holdup was measured using four tips optical fiber probe technique. The results showed that the gas holdup increases almost linearly with the superficial gas velocity in 0.08 m/s and levels off with a further increase of velocity. A comparison of the present data with those reported for other slurry bubble column having diameters greater than 18″ and L/D higher than 5 was made. The results indicated a little effect of diameter on the gas holdup. A local, section-averaged gas holdup increases with increasing superficial gas velocity, while the effect of solid loading are less significant than that of the superficial gas velocity. Chaos analysis was used to analyze the slurry system.