LBLuc Beuzit

Luc Beuzit

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Luc Beuzit has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Selective Internal Radiation Combined with Chemotherapy Maintains the Quality of Life in Intrahepatic Cholangiocarcinomas

    by Camille Goislard de Monsabert, Yann Touchefeu, Boris Guiu, Boris Campillo-Gimenez, Olivier Farges, David Tougeron, Isabelle Baumgaertner, Ahmet Ayav, Luc Beuzit, Marc Pracht, et al.

    Background: In the Yttrium-90 Microspheres in Cholangiocarcinoma (MISPHEC) single-arm phase 2 trial, concomitant chemotherapy and selective internal radiotherapy (SIRT) showed antitumor activity as a first-line treatment of unresectable intrahepatic cholangiocarcinomas (ICCs). In this sub-analysis, we aimed to evaluate one of the secondary endpoints, the health-related quality of life (QoL), evaluated with an EORTC QLQ-C30 instrument at the baseline and during treatment. Methods: The MISPHEC trial included treatment-naïve patients with an unresectable ICC between November 2013 and June 2016. Patients received concomitant first-line chemotherapy with cisplatin and gemcitabine for 8 cycles; SIRT was administered during cycle 1 (for patients with unilobar disease) or cycles 1 and 3 (for patients with bilobar disease) using glass Yttrium-90 microspheres. We evaluated the QoL—measured by the QLQ-C30 questionnaire—at the baseline, every 8 weeks during chemotherapy and follow-up, between 12 and 15 weeks after embolization and every 12 weeks after a liver resection if applicable. Results: A total of 41 patients were included, of which 34 completed questionnaires at the baseline. No clinically significant changes in the global health score or the sub-scales of the QLQ-C30 were observed during follow-up. The physical, social and role function mean score worsened during treatment and fatigue, nausea and pain scores increased although the differences were not clinically significant. In patients undergoing subsequent surgery, the QoL was not impaired. Conclusions: A combination of SIRT and chemotherapy with gemcitabine and cisplatin as the first-line treatment of unresectable ICCs was found to maintain the QoL.


  • Dynamic contrast‐enhanced MRI: Study of inter‐software accuracy and reproducibility using simulated and clinical data

    by Luc Beuzit, Pierre‐Antoine Eliat, Vanessa Brun, Jean‐Christophe Ferré, Yves Gandon, Elise Bannier, Hervé Saint‐Jalmes

    Purpose: To test the reproducibility and accuracy of pharmacokinetic parameter measurements on five analysis software packages (SPs) for dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI), using simulated and clinical data.Materials and Methods: This retrospective study was Institutional Review Board‐approved. Simulated tissues consisted of pixel clusters of calculated dynamic signal changes for combinations of Tofts model pharmacokinetic parameters (volume transfer constant [Ktrans], extravascular extracellular volume fraction [ve]), longitudinal relaxation time (T1). The clinical group comprised 27 patients treated for rectal cancer, with 36 3T DCE‐MR scans performed between November 2012 and February 2014, including dual‐flip‐angle T1 mapping and a dynamic postcontrast T1‐weighted, 3D spoiled gradient‐echo sequence. The clinical and simulated images were postprocessed with five SPs to measure Ktrans, ve, and the initial area under the gadolinium curve (iAUGC). Modified Bland–Altman analysis was conducted, intraclass correlation coefficients (ICCs) and within‐subject coefficients of variation were calculated.Results: Thirty‐one examinations from 23 patients were of sufficient technical quality and postprocessed. Measurement errors were observed on the simulated data for all the pharmacokinetic parameters and SPs, with a bias ranging from −0.19 min−1 to 0.09 min−1 for Ktrans, −0.15 to 0.01 for ve, and −0.65 to 1.66 mmol.L−1.min for iAUGC. The ICC between SPs revealed moderate agreement for the simulated data (Ktrans: 0.50; ve: 0.67; iAUGC: 0.77) and very poor agreement for the clinical data (Ktrans: 0.10; ve: 0.16; iAUGC: 0.21).Conclusion: Significant errors were found in the calculated DCE‐MRI pharmacokinetic parameters for the perfusion analysis SPs, resulting in poor inter‐software reproducibility. J. Magn. Reson. Imaging 2016;43:1288–1300.