Thomas Lefort
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Lefort has a total of 214 co-authors. Here are the top co-authors by number of shared publications:
G. Ban
ENSICAEN Normandie Université UNICAEN CNRS/IN2P3 LPC Caen 14000 Caen France
6 shared publications- Guillaume Pignol
Université Grenoble Alpes CNRS Grenoble INP LPSC-IN2P3 38026 Grenoble France
6 shared publications K. Bodek
Marian Smoluchowski Institute of Physics Jagiellonian University 30-348 Cracow Poland
6 shared publicationsD. Pais
Institute for Particle Physics and Astrophysics ETH Zürich CH-8093 Zürich Switzerland
5 shared publicationsD. Rebreyend
Université Grenoble Alpes CNRS Grenoble INP LPSC-IN2P3 38026 Grenoble France
5 shared publicationsD. Ries
Paul Scherrer Institut CH-5232 Villigen PSI Switzerland
5 shared publications
Latest Publications
- Open Access
- 22 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Further search for magnetic-field-induced neutron disappearance in an ultracold neutron beam
- 22 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Open AccessFurther search for magnetic-field-induced neutron disappearance in an ultracold neutron beam
- Open Access
Measurement of the neutron incoherent scattering length of ${}^{199}$Hg using stored ultracold neutrons
We present the first direct measurement of the neutron incoherent scattering length of ${}^{199}$Hg. The measurement was performed with the Ramsey apparatus of the neutron electric dipole moment experiment located at the Paul Scherrer Institute. The incoherent scattering length $b_\textrm{i}$ was determined by investigating the pseudo-magnetic effect due to the strong interaction between the neutron spins and the nuclear spins of mercury atoms. The resulting frequency shift of the neutron Larmor precession frequency was determined for various ${}^{199}$Hg density and polarization values. The obtained value of $b_\textrm{i}= (-16.2 \pm 2.0)\,$fm agrees in magnitude with previous determinations and provides the so-far unknown sign of the quantity.Open AccessMeasurement of the neutron incoherent scattering length of ${}^{199}$Hg using stored ultracold neutrons
We present the first direct measurement of the neutron incoherent scattering length of ${}^{199}$Hg. The measurement was performed with the Ramsey apparatus of the neutron electric dipole moment experiment located at the Paul Scherrer Institute. The incoherent scattering length $b_\textrm{i}$ was determined by investigating the pseudo-magnetic effect due to the strong interaction between the neutron spins and the nuclear spins of mercury atoms. The resulting frequency shift of the neutron Larmor precession frequency was determined for various ${}^{199}$Hg density and polarization values. The obtained value of $b_\textrm{i}= (-16.2 \pm 2.0)\,$fm agrees in magnitude with previous determinations and provides the so-far unknown sign of the quantity. - Open Access
Ultracold neutron energy spectrum and storage properties from magnetically induced spin depolarization
We present a novel method for extracting the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements using the n2EDM apparatus. This method is also sensitive to the storage properties of the materials used to trap ultracold neutrons, specifically, whether collisions are specular or diffuse. We highlight the sensitivity of this new technique by comparing the two different storage chambers of the n2EDM experiment. We validate the extraction by comparing to an independent measurement for how this energy spectrum is polarized through a magnetic-filter, and finally, we calculate the neutron center-of-mass offset, an important systematic effect for measurements of the neutron electric dipole moment.
Open AccessUltracold neutron energy spectrum and storage properties from magnetically induced spin depolarization
We present a novel method for extracting the energy spectrum of ultracold neutrons from magnetically induced spin depolarization measurements using the n2EDM apparatus. This method is also sensitive to the storage properties of the materials used to trap ultracold neutrons, specifically, whether collisions are specular or diffuse. We highlight the sensitivity of this new technique by comparing the two different storage chambers of the n2EDM experiment. We validate the extraction by comparing to an independent measurement for how this energy spectrum is polarized through a magnetic-filter, and finally, we calculate the neutron center-of-mass offset, an important systematic effect for measurements of the neutron electric dipole moment.
- Open Access
- 20 February 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (2) , 1-19
Generating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment
We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $$B_0$$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of $$273~\hbox {cm}$$ , inside a large magnetically shielded room (MSR). We have assembled this system and characterized its performances with a mapping robot. The apparatus is able to generate a $$1~\upmu \hbox {T}$$ vertical field with a relative root mean square deviation $$\sigma (B_z)/B_z = 3\times 10^{-5}$$ over the volume of interest, a cylinder of radius $$40~\hbox {cm}$$ and height $${30}~\hbox {cm}$$ . This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than $$1\times 10^{-27}e\,\hbox {cm}$$ .- 20 February 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (2) , 1-19
Open AccessGenerating a highly uniform magnetic field inside the magnetically shielded room of the n2EDM experiment
We present a coil system designed to generate a highly uniform magnetic field for the n2EDM experiment at the Paul Scherrer Institute. It consists of a main $$B_0$$ coil and a set of auxiliary coils mounted on a cubic structure with a side length of $$273~\hbox {cm}$$ , inside a large magnetically shielded room (MSR). We have assembled this system and characterized its performances with a mapping robot. The apparatus is able to generate a $$1~\upmu \hbox {T}$$ vertical field with a relative root mean square deviation $$\sigma (B_z)/B_z = 3\times 10^{-5}$$ over the volume of interest, a cylinder of radius $$40~\hbox {cm}$$ and height $${30}~\hbox {cm}$$ . This level of uniformity overcomes the n2EDM requirements, allowing a measurement of the neutron Electric Dipole Moment with a sensitivity better than $$1\times 10^{-27}e\,\hbox {cm}$$ . - Open Access
- 21 July 2021
- Published by Springer Nature in The European Physical Journal A
- Vol. 57 (7) , 1
Erratum to: Data blinding for the nEDM experiment at PSI
A Correction to this paper has been published: https://doi.org/10.1140/epja/s10050-021-00456-1
- 21 July 2021
- Published by Springer Nature in The European Physical Journal A
- Vol. 57 (7) , 1
Open AccessErratum to: Data blinding for the nEDM experiment at PSI
A Correction to this paper has been published: https://doi.org/10.1140/epja/s10050-021-00456-1
- Open Access
- 1 January 2021
- Published by Elsevier in Physics Letters B
- Vol. 812
A search for neutron to mirror-neutron oscillations using the nEDM apparatus at PSI
- 1 January 2021
- Published by Elsevier in Physics Letters B
- Vol. 812
Open AccessA search for neutron to mirror-neutron oscillations using the nEDM apparatus at PSI
- 28 October 2016
- Published by Springer Nature in The European Physical Journal A
- Vol. 52 (10) , 326
Ultracold neutron detection with 6Li-doped glass scintillators
- 28 October 2016
- Published by Springer Nature in The European Physical Journal A
- Vol. 52 (10) , 326
Ultracold neutron detection with 6Li-doped glass scintillators
- Open Access
Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute
This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-depleted glass bonded to a 6Li-enriched glass. The optical contact bonding is used between the scintillators in order to obtain a perfect optical contact. The scintillator's detection efficiency is similar to that of a 3He Strelkov gas detector. Coupled to a digital data acquisition system, counting rates up to a few 10^5 counts/s can be handled. A detector based on such a scintillator stack arrangement was built and has been used in the neutron electric dipole moment experiment at the Paul Scherrer Institute since 2010. Its response for the regular runs of the neutron electric dipole moment experiment is presented.
Open AccessUltracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute
This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-depleted glass bonded to a 6Li-enriched glass. The optical contact bonding is used between the scintillators in order to obtain a perfect optical contact. The scintillator's detection efficiency is similar to that of a 3He Strelkov gas detector. Coupled to a digital data acquisition system, counting rates up to a few 10^5 counts/s can be handled. A detector based on such a scintillator stack arrangement was built and has been used in the neutron electric dipole moment experiment at the Paul Scherrer Institute since 2010. Its response for the regular runs of the neutron electric dipole moment experiment is presented.
- Open Access
- 19 March 2009
- Published by American Physical Society (APS) in Physical Review C
- Vol. 79 (3) , 034607
Centrality dependence of the thermal excitation-energy deposition in 8–15 GeV/hadron-Au reactionsThe excitation energy per residue nucleon () and fast and thermal light particle multiplicities are studied as a function of centrality defined as the number of grey tracks emitted and by the mean number of primary hadron-nucleon scatterings () and the mean impact parameter () extracted from it. The value of and the multiplicities show an increase with centrality for all systems, 14.6 GeV p-Au and 8.0 GeV π-Au and -Au collisions, and the excitation energy per residue nucleon exhibits a uniform dependence on .- 19 March 2009
- Published by American Physical Society (APS) in Physical Review C
- Vol. 79 (3) , 034607
Open AccessCentrality dependence of the thermal excitation-energy deposition in 8–15 GeV/hadron-Au reactionsThe excitation energy per residue nucleon () and fast and thermal light particle multiplicities are studied as a function of centrality defined as the number of grey tracks emitted and by the mean number of primary hadron-nucleon scatterings () and the mean impact parameter () extracted from it. The value of and the multiplicities show an increase with centrality for all systems, 14.6 GeV p-Au and 8.0 GeV π-Au and -Au collisions, and the excitation energy per residue nucleon exhibits a uniform dependence on . - Open Access
- 4 January 2007
- Published by Sissa Medialab Srl
A NOVEL FAST NEUTRON DETECTOR FOR NUCLEAR DATA MEASUREMENTS
- 4 January 2007
- Published by Sissa Medialab Srl
Open AccessA NOVEL FAST NEUTRON DETECTOR FOR NUCLEAR DATA MEASUREMENTS