Farshid Tabbakh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Farshid Tabbakh has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Mahdieh Sadat Hoseyni
University of Isfahan
2 shared publicationsMohammad Pashaei
Institute of Nuclear Science and Technology, Plasma and Nuclear Fusion Research School, Tehran, 14399-51113, Iran
2 shared publicationsMojtaba Mostajab Aldaavati
University of Isfahan
2 shared publications- Narayan S. Hosmane
Northern Illinois University
2 shared publications Seyed Mahmood Sadat Kiai
Institute of Nuclear Science and Technology, Plasma and Nuclear Fusion Research School, Tehran, 14399-51113, Iran
2 shared publicationsAli Nabipour Chakoli
Plasma and Nuclear Fusion Research School, Nuclear Science and Technology Research Institute, 14155-1339, Tehran, Iran
1 shared publication
Latest Publications
- Open Access
- 9 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 8012
Resolving the contradiction between simulation and experimental results of using gold nanoparticles in proton therapy
While gold nanoparticles (GNP)s in proton therapy are widely assumed to exert radio-sensitization via mechanism of secondary electron emission, the discrepancies between simulations and experimental outcomes shows that, in some cases, the secondary electron hypothesis fails to explain the experimental observations particularly distant DNA damage beyond the range of low-energy electrons. These persistent discrepancies show weaknesses of this mechanism, as noted by multiple studies. Resolving the long-standing discrepancy is the main purpose of present research. We predict the survival fractions and sensitization enhancement by Geant4 to bridge the gap between simulation and in-vitro data. Through Geant4 Monte Carlo simulations we demonstrate that proton stopping – not electron emission- by GNPs is the dominant mechanism, driving the GNP enhanced proton therapy via amplification of proton’s linear energy transfer (LET). For the first time, our model successfully reconciles simulation with experimental data by quantifying the key radiobiological parameters: dose enhancement ratio (DER) and sensitization enhancement ratio (SER). These findings redefine GNPs as proton energy modulators rather than electron emitters, resolving the long-standing simulation-experiment discrepancies. However, it is emphasized that, the secondary electron emission from metallic NPs in the range of nano-scale have remarkable impact. Furthermore, we derive a mathematical relationship between DER and cell survival fraction (SF) in the linear-quadratic (LQ) model with predicted survival curves showing strong agreement with in-vitro data.
- 9 February 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1) , 8012
Open AccessResolving the contradiction between simulation and experimental results of using gold nanoparticles in proton therapy
While gold nanoparticles (GNP)s in proton therapy are widely assumed to exert radio-sensitization via mechanism of secondary electron emission, the discrepancies between simulations and experimental outcomes shows that, in some cases, the secondary electron hypothesis fails to explain the experimental observations particularly distant DNA damage beyond the range of low-energy electrons. These persistent discrepancies show weaknesses of this mechanism, as noted by multiple studies. Resolving the long-standing discrepancy is the main purpose of present research. We predict the survival fractions and sensitization enhancement by Geant4 to bridge the gap between simulation and in-vitro data. Through Geant4 Monte Carlo simulations we demonstrate that proton stopping – not electron emission- by GNPs is the dominant mechanism, driving the GNP enhanced proton therapy via amplification of proton’s linear energy transfer (LET). For the first time, our model successfully reconciles simulation with experimental data by quantifying the key radiobiological parameters: dose enhancement ratio (DER) and sensitization enhancement ratio (SER). These findings redefine GNPs as proton energy modulators rather than electron emitters, resolving the long-standing simulation-experiment discrepancies. However, it is emphasized that, the secondary electron emission from metallic NPs in the range of nano-scale have remarkable impact. Furthermore, we derive a mathematical relationship between DER and cell survival fraction (SF) in the linear-quadratic (LQ) model with predicted survival curves showing strong agreement with in-vitro data.
- 7 August 2025
- Published by Wolters Kluwer Health in Health Physics
- Vol. 130 (5) , 619-624
Depth Dose Profile and Exposure Time Calculation in an 60Co Irradiation Processing Facility: MCNP and GEANT4 Calculation
The present research is proposing a mathematical method to calculate the dose absorbed by a moving object in a non-uniform radiation field. In such conditions, the dose is the function of time and position of the object relative to the radiation source. In this regard, a 60 Co irradiation processing facility has been investigated in which, the non-uniform planar source of gamma-rays, irradiates the boxes moving which move around the source. In irradiation facilities, addition to the strength of 60 Co source, the speed of boxes is in great importance in obtaining the desired total dose to the boxes, however in most cases, the speed has been determined traditionally and by try-and-error method after the construction and installation of the radiation source. In this research, the speed of boxes (conveyor’s speed) was determined so that, the desired dose has been delivered to each box. The dose profile inside of the boxes has been calculated based on the different positions from the rack. The presented calculations aim to optimize the detailed design of the mentioned facility and for the more efficient performance because, it helps to make the faster radiation processing in a smaller place. The calculations have been conducted using MCNPX.2.7 and Geant4.10.5 Monte Carlo tools in order to obtain most reliable results.
- 7 August 2025
- Published by Wolters Kluwer Health in Health Physics
- Vol. 130 (5) , 619-624
Depth Dose Profile and Exposure Time Calculation in an 60Co Irradiation Processing Facility: MCNP and GEANT4 Calculation
The present research is proposing a mathematical method to calculate the dose absorbed by a moving object in a non-uniform radiation field. In such conditions, the dose is the function of time and position of the object relative to the radiation source. In this regard, a 60 Co irradiation processing facility has been investigated in which, the non-uniform planar source of gamma-rays, irradiates the boxes moving which move around the source. In irradiation facilities, addition to the strength of 60 Co source, the speed of boxes is in great importance in obtaining the desired total dose to the boxes, however in most cases, the speed has been determined traditionally and by try-and-error method after the construction and installation of the radiation source. In this research, the speed of boxes (conveyor’s speed) was determined so that, the desired dose has been delivered to each box. The dose profile inside of the boxes has been calculated based on the different positions from the rack. The presented calculations aim to optimize the detailed design of the mentioned facility and for the more efficient performance because, it helps to make the faster radiation processing in a smaller place. The calculations have been conducted using MCNPX.2.7 and Geant4.10.5 Monte Carlo tools in order to obtain most reliable results.
- 1 April 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (4) , 1-10
Dose comparison of slowing-down protons and secondary electrons by gold nanoparticle in proton therapy: simulation study
- 1 April 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (4) , 1-10
Dose comparison of slowing-down protons and secondary electrons by gold nanoparticle in proton therapy: simulation study
- Open Access
- 23 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Significance of the proton energy loss mechanism to gold nanoparticles in proton therapy: a Geant4 simulation
The biological effectiveness in proton therapy is only slightly greater than of the treatment by X-ray and hence, many researches have suggested the use of gold nanoparticles for increasing the ionization interactions to produce more secondary electrons and elevate the yield of DNA damage. But the ionization interactions also lead to protons energy loss inside the nanoparticles. The present study shows that, the protons slowed-down by High-Z nanoparticles are responsible for dose enhancement rather than the produced secondary electrons. To this purpose, using Geant4 Monte Carlo tool, one million nanoparticles distributed in a proton irradiated volume and variation of the proton’s spectra and the dose related to this variation has been demonstrated. It was found that, the elevation in proton’s LET values when passing through the gold nanoparticles will lead to a more significant dose enhancement than the increased dose due to the extra secondary electrons. Also, it was found that, the mechanism of protons slowing-down by gold nanoparticles has another useful aspect in proton therapy in which, the dose leakage to surrounding healthy tissues will be reduced which must be considered in future investigations more precisely.
- 23 October 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Open AccessSignificance of the proton energy loss mechanism to gold nanoparticles in proton therapy: a Geant4 simulation
The biological effectiveness in proton therapy is only slightly greater than of the treatment by X-ray and hence, many researches have suggested the use of gold nanoparticles for increasing the ionization interactions to produce more secondary electrons and elevate the yield of DNA damage. But the ionization interactions also lead to protons energy loss inside the nanoparticles. The present study shows that, the protons slowed-down by High-Z nanoparticles are responsible for dose enhancement rather than the produced secondary electrons. To this purpose, using Geant4 Monte Carlo tool, one million nanoparticles distributed in a proton irradiated volume and variation of the proton’s spectra and the dose related to this variation has been demonstrated. It was found that, the elevation in proton’s LET values when passing through the gold nanoparticles will lead to a more significant dose enhancement than the increased dose due to the extra secondary electrons. Also, it was found that, the mechanism of protons slowing-down by gold nanoparticles has another useful aspect in proton therapy in which, the dose leakage to surrounding healthy tissues will be reduced which must be considered in future investigations more precisely.
- 17 June 2023
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 138 (6) , 1-8
Enhanced biological effectiveness with carbon nanoparticles in proton therapy: a simulation study
- 17 June 2023
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 138 (6) , 1-8
Enhanced biological effectiveness with carbon nanoparticles in proton therapy: a simulation study
- Open Access
- 18 October 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Using 157Gd doped carbon and 157GdF4 nanoparticles in proton-targeted therapy for effectiveness enhancement and thermal neutron reduction: a simulation study
There are two major problems in proton therapy. (1) In comparison with the gamma-ray therapy, proton therapy has only ~ 10% greater biological effectiveness, and (2) the risk of the secondary neutrons in proton therapy is another unsolved problem. In this report, the increase of biological effectiveness in proton therapy has been evaluated with better performance than 11B in the presence of two proposed nanomaterials of 157GdF4 and 157Gd doped carbon with the thermal neutron reduction due to the presence of 157Gd isotope. The present study is based on the microanalysis calculations using GEANT4 Monte Carlo tool and GEANT4-DNA package for the strand breaks measurement. It was found that the proposed method will increase the effectiveness corresponding to the alpha particles by more than 100% and also, potentially will decrease the thermal neutrons fluence, significantly. Also, in this work, a discussion is presented on a significant contribution of the secondary alpha particles in total effectiveness in proton therapy.
- 18 October 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Open AccessUsing 157Gd doped carbon and 157GdF4 nanoparticles in proton-targeted therapy for effectiveness enhancement and thermal neutron reduction: a simulation study
There are two major problems in proton therapy. (1) In comparison with the gamma-ray therapy, proton therapy has only ~ 10% greater biological effectiveness, and (2) the risk of the secondary neutrons in proton therapy is another unsolved problem. In this report, the increase of biological effectiveness in proton therapy has been evaluated with better performance than 11B in the presence of two proposed nanomaterials of 157GdF4 and 157Gd doped carbon with the thermal neutron reduction due to the presence of 157Gd isotope. The present study is based on the microanalysis calculations using GEANT4 Monte Carlo tool and GEANT4-DNA package for the strand breaks measurement. It was found that the proposed method will increase the effectiveness corresponding to the alpha particles by more than 100% and also, potentially will decrease the thermal neutrons fluence, significantly. Also, in this work, a discussion is presented on a significant contribution of the secondary alpha particles in total effectiveness in proton therapy.
- Open Access
- 25 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Enhancement of Radiation Effectiveness in Proton Therapy: Comparison Between Fusion and Fission Methods and Further Approaches
Proton therapy as a promising candidate in cancer treatment has attracted much attentions and many studies have been performed to investigate the new methods to enhance its radiation effectiveness. In this regard, two research groups have suggested that using boron isotopes will lead to a radiation effectiveness enhancement, using boron-11 agent to initiate the proton fusion reaction (P-BFT) and using boron-10 agent to capture the low energy secondary neutrons (NCEPT). Since, these two innovative methods have not been approved clinically, they have been recalculated in this report, discussed and compared between them and also with the traditional proton therapy to evaluate their impacts before the experimental investigations. The calculations in the present study were performed by Geant4 and MCNPX Monte Carlo Simulation Codes were utilized for obtaining more precision in our evaluations of these methods impacts. Despite small deviations in the results from the two MC tools for the NCEPT method, a good agreement was observed regarding the delivered dose rate to the tumor site at different depths while, for P-BFT related calculations, the GEANT4 was in agreement with the analytical calculations by means of the detailed cross-sections of proton-11B fusion. Accordingly, both the methods generate excess dose rate to the tumor several orders of magnitude lower than the proton dose rate. Also, it was found that, the P-BFT has more significant enhancement of effectiveness, when compared to the NCEPT, a method with impact strongly depended on the tumor’s depth. On the other hand, the advantage of neutron risk reduction proposed by NCEPT was found to give no considerable changes in the neutron dose absorption by healthy tissues.
- 25 March 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-12
Open AccessEnhancement of Radiation Effectiveness in Proton Therapy: Comparison Between Fusion and Fission Methods and Further Approaches
Proton therapy as a promising candidate in cancer treatment has attracted much attentions and many studies have been performed to investigate the new methods to enhance its radiation effectiveness. In this regard, two research groups have suggested that using boron isotopes will lead to a radiation effectiveness enhancement, using boron-11 agent to initiate the proton fusion reaction (P-BFT) and using boron-10 agent to capture the low energy secondary neutrons (NCEPT). Since, these two innovative methods have not been approved clinically, they have been recalculated in this report, discussed and compared between them and also with the traditional proton therapy to evaluate their impacts before the experimental investigations. The calculations in the present study were performed by Geant4 and MCNPX Monte Carlo Simulation Codes were utilized for obtaining more precision in our evaluations of these methods impacts. Despite small deviations in the results from the two MC tools for the NCEPT method, a good agreement was observed regarding the delivered dose rate to the tumor site at different depths while, for P-BFT related calculations, the GEANT4 was in agreement with the analytical calculations by means of the detailed cross-sections of proton-11B fusion. Accordingly, both the methods generate excess dose rate to the tumor several orders of magnitude lower than the proton dose rate. Also, it was found that, the P-BFT has more significant enhancement of effectiveness, when compared to the NCEPT, a method with impact strongly depended on the tumor’s depth. On the other hand, the advantage of neutron risk reduction proposed by NCEPT was found to give no considerable changes in the neutron dose absorption by healthy tissues.
- 1 November 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 129, 211-214
Conceptual achievement of 1GBq activity in a Plasma Focus driven system
- 1 November 2017
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 129, 211-214
Conceptual achievement of 1GBq activity in a Plasma Focus driven system
- 19 December 2015
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 35 (2) , 401-406
Particles Transportation and Nuclear Heating in a Tokamak by MCNPX and GEANT4
- 19 December 2015
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 35 (2) , 401-406
Particles Transportation and Nuclear Heating in a Tokamak by MCNPX and GEANT4