James F. Christian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
James F. Christian has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Eric Chapman
Radiation Monitoring Devices, Watertown
4 shared publicationsErik B. Johnson
4 shared publicationsGuy Alberghini
Radiation Monitoring Devices, Watertown
3 shared publicationsXiao Jie Chen
Radiation Monitoring Devices, Watertown
3 shared publications- Christopher J. Stapels
Radiation Monitoring Devices, Inc. (United States)
2 shared publications Christopher J. Staples
Radiation Monitoring Devices, Watertown
2 shared publications
Latest Publications
- Open Access
- 1 January 2018
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics: Conference Series
- Vol. 48
Recent developments in high-resolution-gamma-ray cargo-inspection technology
Under US Department of Homeland Security sponsorship, Spectral Labs Incorporated has developed a prototype high-resolution retrofit for an existing mobile VACIS, named the High-Resolution Imaging System (HiRIS). The legacy 256 NaI detectors in the VACIS detector column were replaced with 576 CsI detectors, more than doubling the pixel count. Using SiPMs to replace conventional PMTs allowed the packing of more detectors in the same VACIS detector enclosure. Legacy analog signal-processing electronics were replaced with advanced digital signal-processing electronics. Replacing gross counting in the legacy system with multichannel analysis of the counts from each detector will allow better control of detector crosstalk. The HiRIS detector modules were installed on a VACIS truck refurbished to as-new condition. Initial testing of the HiRIS prototype demonstrates enhanced spatial resolution by a factor of two as compared to the legacy system, without any degradation in throughput capability (20 containers per hour).
- 1 January 2018
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics: Conference Series
- Vol. 48
Open AccessRecent developments in high-resolution-gamma-ray cargo-inspection technology
Under US Department of Homeland Security sponsorship, Spectral Labs Incorporated has developed a prototype high-resolution retrofit for an existing mobile VACIS, named the High-Resolution Imaging System (HiRIS). The legacy 256 NaI detectors in the VACIS detector column were replaced with 576 CsI detectors, more than doubling the pixel count. Using SiPMs to replace conventional PMTs allowed the packing of more detectors in the same VACIS detector enclosure. Legacy analog signal-processing electronics were replaced with advanced digital signal-processing electronics. Replacing gross counting in the legacy system with multichannel analysis of the counts from each detector will allow better control of detector crosstalk. The HiRIS detector modules were installed on a VACIS truck refurbished to as-new condition. Initial testing of the HiRIS prototype demonstrates enhanced spatial resolution by a factor of two as compared to the legacy system, without any degradation in throughput capability (20 containers per hour).
- 7 September 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 6
Neutron detection with plastic scintillators coupled to solid-state photomultiplier detectors
- 7 September 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 6
Neutron detection with plastic scintillators coupled to solid-state photomultiplier detectors
- 23 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (6) , 3095-3102
Radiation Effects on a Potential Scintillation-Based Solid-State Spectrometer Prototype for Compact Monitoring of Space Radiation/Weather Satellite Conditions
New and emerging scintillators, such as DPA (Diphenylanthracene) and CLYC (Cs2LiYCl6:Ce), coupled with Solid-State Photomultipliers (SSPM) provide a lightweight, low voltage, potentially radiation hard spectrometer for real-time monitoring of space weather conditions. This paper presents the results from proton radiation-hardness tests conducted for candidate scintillators and for individual cells of 1 cm2 SSPMs. Decreases from original light outputs were observed for samples of DPA and CLYC by 4% and 28% respectively with a dose of 1 kGy . Following 1 kGy exposure to the SSPMs, the dark current increased by a factor of ~ 32 for a reverse bias of 30 V. The effects of room temperature annealing on the dark current were also monitored. Decreases in quantum efficiency (22% for 420 nm and 7% for 535 nm) and light response (33% for 420 nm and 26% for 535 nm) were observed as a possible result of the formation of surface recombination-generation centers. The energy resolution of a LYSO scintillator sample coupled with a SSPM and measured for a 22Na gamma source (E = 511 kev) decreased from 15% pre-irradiation to 34% post 1 kGy irradiation.
- 23 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (6) , 3095-3102
Radiation Effects on a Potential Scintillation-Based Solid-State Spectrometer Prototype for Compact Monitoring of Space Radiation/Weather Satellite Conditions
New and emerging scintillators, such as DPA (Diphenylanthracene) and CLYC (Cs2LiYCl6:Ce), coupled with Solid-State Photomultipliers (SSPM) provide a lightweight, low voltage, potentially radiation hard spectrometer for real-time monitoring of space weather conditions. This paper presents the results from proton radiation-hardness tests conducted for candidate scintillators and for individual cells of 1 cm2 SSPMs. Decreases from original light outputs were observed for samples of DPA and CLYC by 4% and 28% respectively with a dose of 1 kGy . Following 1 kGy exposure to the SSPMs, the dark current increased by a factor of ~ 32 for a reverse bias of 30 V. The effects of room temperature annealing on the dark current were also monitored. Decreases in quantum efficiency (22% for 420 nm and 7% for 535 nm) and light response (33% for 420 nm and 26% for 535 nm) were observed as a possible result of the formation of surface recombination-generation centers. The energy resolution of a LYSO scintillator sample coupled with a SSPM and measured for a 22Na gamma source (E = 511 kev) decreased from 15% pre-irradiation to 34% post 1 kGy irradiation.
- 8 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8142, 81420O-81420
Cryogenic CMOS avalanche diodes for nuclear physics research
Exploration in nuclear physics may require extreme conditions, such as temperatures down to a few Kelvin, high magnetic fields of several Tesla, or the small physical dimensions of a few centimeters. As a standard technique for radiation detection using scintillation materials, it is desirable to develop photodetectors that can operate under these harsh conditions. Though photomultiplier tubes (PMTs) have been used for most applications for readout of scintillation materials, they are bulky, highly susceptible to magnetic fields, and present a large heat load in cryogenic environments. Avalanche photodiodes are a reasonable alternative to PMTs in that they are extremely compact and less susceptible to magnetic fields. Avalanche photodiodes have been developed in a commercial CMOS process for operation at temperatures below 100 Kelvin. Here we present the overall operation of the photodiodes at 5 Kelvin. The diodes show a quantum efficiency of at least 30% at 532 nm at 5 Kelvin. At about 30 Kelvin, the diodes exhibit an internal resistive term, which generates a second breakdown point. The prototype diode shows a proportional response to the intensity of light pulses down to 150 detected photons with a hole to electron ionization ratio, k, of 2.3x10-13 at 5 Kelvin. The properties of the photodiodes and the readout electronics will be discussed for general photon detection below 100 K.
- 8 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8142, 81420O-81420
Cryogenic CMOS avalanche diodes for nuclear physics research
Exploration in nuclear physics may require extreme conditions, such as temperatures down to a few Kelvin, high magnetic fields of several Tesla, or the small physical dimensions of a few centimeters. As a standard technique for radiation detection using scintillation materials, it is desirable to develop photodetectors that can operate under these harsh conditions. Though photomultiplier tubes (PMTs) have been used for most applications for readout of scintillation materials, they are bulky, highly susceptible to magnetic fields, and present a large heat load in cryogenic environments. Avalanche photodiodes are a reasonable alternative to PMTs in that they are extremely compact and less susceptible to magnetic fields. Avalanche photodiodes have been developed in a commercial CMOS process for operation at temperatures below 100 Kelvin. Here we present the overall operation of the photodiodes at 5 Kelvin. The diodes show a quantum efficiency of at least 30% at 532 nm at 5 Kelvin. At about 30 Kelvin, the diodes exhibit an internal resistive term, which generates a second breakdown point. The prototype diode shows a proportional response to the intensity of light pulses down to 150 detected photons with a hole to electron ionization ratio, k, of 2.3x10-13 at 5 Kelvin. The properties of the photodiodes and the readout electronics will be discussed for general photon detection below 100 K.
- 13 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (6) , 3450-3455
Space Dosimeters Based on CMOS SSPM Technology
The potential threat of harsh radiation environment requires reliable, fault-tolerant sensors capable of providing real-time dosimetry during a space mission, which cannot be achieved by using existing thermoluminescent dosimeter (TLD) technology, especially during an extravehicular activity (EVA). Dose monitoring in real time is especially important for manned low-Earth orbiting spacecraft and interplanetary space vehicles to alert the crew when Solar Particle Events (SPE) increases the radiation level of the spacecraft environment. The development of a tissue-equivalent, CMOS chip-based, personal space dosimeter will meet the demanding requirements for manned space missions.
- 13 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (6) , 3450-3455
Space Dosimeters Based on CMOS SSPM Technology
The potential threat of harsh radiation environment requires reliable, fault-tolerant sensors capable of providing real-time dosimetry during a space mission, which cannot be achieved by using existing thermoluminescent dosimeter (TLD) technology, especially during an extravehicular activity (EVA). Dose monitoring in real time is especially important for manned low-Earth orbiting spacecraft and interplanetary space vehicles to alert the crew when Solar Particle Events (SPE) increases the radiation level of the spacecraft environment. The development of a tissue-equivalent, CMOS chip-based, personal space dosimeter will meet the demanding requirements for manned space missions.
- 1 December 2010
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 624 (2) , 449-458
Advances in CMOS solid-state photomultipliers for scintillation detector applications
- 1 December 2010
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 624 (2) , 449-458
Advances in CMOS solid-state photomultipliers for scintillation detector applications
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1257-1262
Characterization and Scintillation Studies of a Solid-State Photomultiplier
The solid-state photomultiplier (SSPM) is a relatively new semiconductor based photodetector that, by using hundreds of micro silicon Geiger-APDs, possesses high gain (105 to 106) and low noise while needing only low voltage (40 - 60 V) to operate. The fast response and high intrinsic gain of SSPMs makes them attractive for timing applications, in particular for positron emission tomography (PET). Here we present the results from the characterization of a 1 times 1 mm 2 SSPM (SSPM-050701GR-TO18, Photonique SA). Several intrinsic SSPM characteristics were measured such as gain, noise, and linearity. Single photon spectra were also collected. Additionally, scintillation studies were performed. The SSPM was coupled to CsI:Tl and LSO scintillation crystals and exposed to various common laboratory radionuclides to measure photopeak energy resolutions. The linearity of the SSPM, when coupled with a scintillator, was also measured. Using a 22 Na source (511 keV annihilation photons), the coincidence timing resolution was measured with the SSPM coupled to LSO. Lastly, we introduce our complementary metal oxide semiconductor (CMOS) based SSPM and show preliminary characterizations.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1257-1262
Characterization and Scintillation Studies of a Solid-State Photomultiplier
The solid-state photomultiplier (SSPM) is a relatively new semiconductor based photodetector that, by using hundreds of micro silicon Geiger-APDs, possesses high gain (105 to 106) and low noise while needing only low voltage (40 - 60 V) to operate. The fast response and high intrinsic gain of SSPMs makes them attractive for timing applications, in particular for positron emission tomography (PET). Here we present the results from the characterization of a 1 times 1 mm 2 SSPM (SSPM-050701GR-TO18, Photonique SA). Several intrinsic SSPM characteristics were measured such as gain, noise, and linearity. Single photon spectra were also collected. Additionally, scintillation studies were performed. The SSPM was coupled to CsI:Tl and LSO scintillation crystals and exposed to various common laboratory radionuclides to measure photopeak energy resolutions. The linearity of the SSPM, when coupled with a scintillator, was also measured. Using a 22 Na source (511 keV annihilation photons), the coincidence timing resolution was measured with the SSPM coupled to LSO. Lastly, we introduce our complementary metal oxide semiconductor (CMOS) based SSPM and show preliminary characterizations.