HQHuacheng Qiu

Huacheng Qiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Huacheng Qiu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Yanguang Yang

    China Aerodynamics Research and Development Center

    4 shared publications
  • Genming Chao

    Hypervelocity Aerodynamics Institute, China Aerodynamics Research and Development Center, Mianyang, China

    2 shared publications
  • Peng Sun

    Hypervelocity Aerodynamics Institute, China Aerodynamics Research and Development Center, Mianyang, China

    2 shared publications
  • Yingdong Chen

    Hypervelocity Aerodynamics Institute, China Aerodynamics Research and Development Center, Mianyang, China

    2 shared publications
  • Yousheng Wu

    Hypervelocity Aerodynamics Institute, China Aerodynamics Research and Development Center, Mianyang, China

    2 shared publications
  • Chunman Mao

    Hypervelocity Aerodynamics Institute, China Aerodynamics Research and Development Center, Mianyang, China

    1 shared publication

Latest Publications

  • Transverse Jet Interaction with Hypersonic Crossflow I: Experimental and Numerical Investigations

    by Huacheng Qiu, Yanguang Yang, Liangbao Sun

    Applications of transverse jet interaction are widespread in hypersonic aircraft systems. In wind tunnel facilities, it is more convenient to perform jet interaction tests with jet fluids of different compositions and with test models of different sizes from those of the actual aircraft. The paper presents a detailed analysis of the transverse jet interaction with hypersonic crossflow by combining the use of both experimental and numerical tools. A hypervelocity ballistic correlation model HB-1, with a sonic jet nozzle, was designed to provide a simplified flowfield for comparison with the simulations. It is found that the temperature and molecular weight of the injectant gas play an important role in the interactions between the hypersonic flow and transverse jet. The applicability of different scaling parameters for this kind of aerodynamic experiment is discussed at the end of this paper.


  • Open Access

    Hypersonic aerodynamic force balance using temperature compensated semiconductor strain gauges

    by Huacheng Qiu, Yanguang Yang, Peng Sun, Genming Chao, Yousheng Wu, Yingdong Chen

    Metal foil strain gauges remain the state-of-the-art transducers for wind tunnel balances. While strain gauge technology is very mature, piezoresistive semiconductor sensors offer alternatives that are worth exploring to assess their unique benefits, such as better strain resolution and accuracy, which would enable balances to be designed with higher factors to safety and hence longer fatigue lifetimes. A new three-component balance, based on temperature compensated semiconductor strain gauges, is designed, calibrated and tested in a hypersonic low density wind tunnel. The static accuracy of the semiconductor balance is calibrated better than 0.3% FS, and the dynamic accuracy of the balance is established using a HB-2 standard model in a Mach 12 hypersonic flow. Good experimental repeatability is confirmed to be better than 2.5% FS, and the effectiveness of the balance is demonstrated by comparing the forces and moments of measured data with computational fluid dynamics simulations, as well as reference wind tunnel results under similar conditions.


  • Open Access

    Hypersonic Aerodynamic Force Balance Using Temperature Compensated Semiconductor Strain Gauges

    by Huacheng Qiu, Yanguang Yang, Peng Sun, Genming Chao, Yousheng Wu, Yingdong Chen

    Metal foil strain gauges remain the state-of-the-art transducers for wind tunnel balance. While strain gauge technology is very mature, piezoresistive semiconductor sensors offer alternatives that are worth exploring to assess the unique benefits, such as better strain resolution and accuracy, which would enable balances to be designed with higher factors to safety and hence longer fatigue lifetimes without sacrificing force resolution and accuracy. A new three-component balance, based on temperature compensated semiconductor strain gauges, has been designed, calibrated and tested in a hypersonic low density wind tunnel. The static accuracy of the semiconductor balance is calibrated better than 0.3%, and the dynamic accuracy of the balance is established using a HB-2 standard model in Mach 12 hypersonic flow. Good experimental repeatability was confirmed to be better than 2.5%, and the effectiveness of the balance is demonstrated by comparing the forces and moments of measured data with computational fluid dynamics simulations, as well as reference wind tunnel results under similar condition.

  • Open Access

    High frequency AC electric glow discharge visualization technology and application in big diameter hypersonic low-density wind tunnel

    by Wanqiu Jiang, Huacheng Qiu, Yanguang Yang, Yilei Shi, Jie Wang, Jie Li, Zhengyi Long, Chunman Mao

    In order to visualize the rarefied flow field in a Φ1m hypersonic low-density wind tunnel, an electric glow discharge technique based on high frequency excited power has been developed. Firstly, finite element simulation analysis has been carried out, and it is concluded that the breakdown voltage can be reduced by using high frequency power supply; then an electric glow discharge apparatus has been fabricated, and the discharge images were compared with simulations; besides, a clear flow field around HB-1 standard model has been observed using this technology; finally, the influence of glow discharge on the flow field, as well as the differences between direct current and high frequency electric glow discharges is discussed at the end of this paper.


  • Open Access

    Hypersonic Aerodynamic Force Balance Using Micromachined All-Fiber Fabry–Pérot Interferometric Strain Gauges

    by Huacheng Qiu, Fu Min, Yanguang Yang, Zengling Ran, Jinxin Duan

    This paper presents high-sensitivity, micromachined all-fiber Fabry–Pérot interferometric (FFPI) strain gauges and their integration in a force balance for hypersonic aerodynamic measurements. The FFPI strain gauge has a short Fabry–Pérot cavity fabricated using an excimer laser etching process, and the deformation of the cavity is detected by a white-light optical phase demodulator. A three-component force balance, using the proposed FFPI gauges as sensing elements, was fabricated, calibrated, and experimentally evaluated. To reduce thermal output of the balance, a simple and effective self-temperature compensation solution, without external temperature sensors, is proposed and examined through both oven heating and wind tunnel runs. As a result of this approach, researchers are able to use the balance continuously throughout a wide range of temperatures. During preliminary testing in a hypersonic wind tunnel with a free stream Mach number of 12, the measurement accuracies of the balance were clearly improved after applying the temperature self-compensation.


  • Open Access

    Electrical characterization, crosstalk compensation and experimental examination of AlN-based piezoelectric micro resonators

    by Huacheng Qiu, Helmut Seidel

    Aluminum nitride based micro resonators are fabricated and measured with an all-electrical excitation and detection method in this paper. Low resistivity single crystal silicon is used as resonating element, serving simultaneously as bottom electrode for the piezoelectric layer. The elimination of the bottom metal electrodes reduces the number of stacked layers and stress in the cantilever; however, the short circuit connection between drive and sense port silicon grounds induces serious feedthrough capacitance effect. Electrical measurement results indicate that, the resonator output is a superposition of mechanical resonance behavior and electrical crosstalk from feedthrough capacitance. A general equivalent circuit model is derived to analyze the resonator's electromechanical performance. To eliminate the electrical crosstalk, a compensation solution has been developed, by applying an inverted adjustable voltage to the common bottom electrode. Further experimental investigations of the device under different controlled pressures show that, the output amplitude after compensation is precisely symmetric around the resonance peak, and phase shift of -90° occurs at resonance, indicating that the feedthrough has been adequently cancelled out.

  • Open Access

    Hydrodynamic Loading on Vibrating Piezoelectric Microresonators

    by Huacheng Qiu, Helmut Seidel

    The dynamics of micro-piezoelectric resonators can be profoundly affected by immersion in fluids. Aluminum nitride-based piezoelectric microresonators are fabricated and tested under controlled pressures in several gases. The cases on microresonator vibrating in fluid can be broadly divided into: (i) those that deal with vibration in free space and (ii) close to a surface. For the first case, experimental and analytical results for the hydrodynamic loading characteristics of the resonators at different resonant modes have been investigated, as well as the influences of fluid viscosity and compressibility. For the second case, most prior efforts have been focused on squeeze-film damping with very narrow gaps, while in many practical applications, the resonators vibrate close to a surface with a moderate distance. Experiments by using a micro-bridge resonator with a big range of gaps are performed and compared with predictions from theoretical models.


  • Hypersonic force measurements using internal balance based on optical micromachined Fabry-Perot interferometry

    by Huacheng Qiu, Fu Min, Shaolong Zhong, Xin Song, Yanguang Yang

    Force measurements using wind tunnel balance are necessary for determining a variety of aerodynamic performance parameters, while the harsh environment in hypersonic flows requires that the measurement instrument should be reliable and robust, in against strong electromagnetic interference, high vacuum, or metal (oxide) dusts. In this paper, we demonstrated a three-component internal balance for hypersonic aerodynamic force measurements, using novel optical micromachined Fabry-Perot interferometric (FPI) strain gauges as sensing elements. The FPI gauges were fabricated using Micro-Opto-Electro-Mechanical Systems (MOEMS) surface and bulk fabrication techniques. High-reflectivity coatings are used to form a high-finesse Fabry-Perot cavity, which benefits a high resolution. Antireflective and passivation coatings are used to reduce unwanted interferences. The FPI strain gauge based balance has been calibrated and evaluated in a Mach 5 hypersonic flow. The results are compared with the traditional technique using the foil resistive strain gauge balance, indicating that the proposed balance based on the MOEMS FPI strain gauge is reliable and robust and is potentially suitable for the hypersonic wind tunnel harsh environment.