Ádám Perényi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ádám Perényi has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
László Rovó
Fül-Orr-Gégészeti és Fej-Nyaksebészeti Klinika, Szegedi Tudományegyetem, Általános Orvostudományi Kar Szeged, Tisza Lajos krt. 111., 6725
2 shared publications- Andrea Koreck
Department of Dermatology and Allergology, University of Szeged, Hungary
1 shared publication Balázs Dimák
Fül-Orr-Gégészeti és Fej-Nyaksebészeti Klinika, Szegedi Tudományegyetem, Általános Orvostudományi Kar Szeged, Tisza Lajos krt. 111., 6725
1 shared publicationEdit Kadocsa
1 shared publicationIstvan Nemeth
1 shared publicationJozsef Jori
1 shared publication
Latest Publications
- Open Access
- 1 August 2019
- Published by Akademiai Kiado Zrt. in Orvosi Hetilap
- Vol. 160 (31) , 1216-1222
The distance from the modiolus of perimodiolar electrode arrays of cochlear implants A radiological study to evaluate the difference in perimodiolar properties
Introduction: The cochlear implants vary in electrodes in terms of length, width and proximity to the modiolus. The precurved electrode arrays could be placed closer to the modiolus and the ganglion cells compared to straight electrodes. The two types of electrode arrays provide different electrophysiological characteristics; however, proximity to the modiolus may lead to better hearing performance. Aim: To investigate our preliminary electrophysiological results that suggest that the Slim Modiolar (SM) electrode array has the potential to elicit similar neural responses as the thicker perimodiolar (Contour Advance, CA) electrode from the same generation of implants. Method: Subjects that were implanted either with CA or SM electrodes were enrolled, 54 consecutive subjects in each group. All electrodes were introduced into the cochlea via the round window. The diameter of the largest turn of the electrode arrays within the cochlea was measured through postoperative radiography. The energy consumption parameters were estimated 2 months after implantation. Results: The mean of the largest turns of the arrays within the cochlea was 4.2 +/- 0.5 mm in the SM group and 4.9 +/- 1.1 mm in the CA group. 'Auto power' was 44.81 +/- 5.05% and 50.85 +/- 8.35% with SM and CA, respectively. Estimated energy consumption was lower with SM. The differences were statistically significant. Conclusion: Our measurements for a large cohort in each group suggest that the SM electrode array takes a significantly closer position to the modiolus than the CA. This finding supports our earlier electrophysiological result and indicates better performance abilities.
- 1 August 2019
- Published by Akademiai Kiado Zrt. in Orvosi Hetilap
- Vol. 160 (31) , 1216-1222
Open AccessThe distance from the modiolus of perimodiolar electrode arrays of cochlear implants A radiological study to evaluate the difference in perimodiolar properties
Introduction: The cochlear implants vary in electrodes in terms of length, width and proximity to the modiolus. The precurved electrode arrays could be placed closer to the modiolus and the ganglion cells compared to straight electrodes. The two types of electrode arrays provide different electrophysiological characteristics; however, proximity to the modiolus may lead to better hearing performance. Aim: To investigate our preliminary electrophysiological results that suggest that the Slim Modiolar (SM) electrode array has the potential to elicit similar neural responses as the thicker perimodiolar (Contour Advance, CA) electrode from the same generation of implants. Method: Subjects that were implanted either with CA or SM electrodes were enrolled, 54 consecutive subjects in each group. All electrodes were introduced into the cochlea via the round window. The diameter of the largest turn of the electrode arrays within the cochlea was measured through postoperative radiography. The energy consumption parameters were estimated 2 months after implantation. Results: The mean of the largest turns of the arrays within the cochlea was 4.2 +/- 0.5 mm in the SM group and 4.9 +/- 1.1 mm in the CA group. 'Auto power' was 44.81 +/- 5.05% and 50.85 +/- 8.35% with SM and CA, respectively. Estimated energy consumption was lower with SM. The differences were statistically significant. Conclusion: Our measurements for a large cohort in each group suggest that the SM electrode array takes a significantly closer position to the modiolus than the CA. This finding supports our earlier electrophysiological result and indicates better performance abilities.
- Open Access
- 1 January 2016
- Published by Akademiai Kiado Zrt. in Orvosi Hetilap
- Vol. 157 (2) , 52-58
A cone-beam komputertomográfia alkalmazása a fül-orr-gégészeti képalkotásban
Absztrakt A modern fül-orr-gégészetben a pontos diagnózis és a korrekt műtéti tervezés alapja a részletes vizualizációt eredményező képalkotás. A csontos keretbe zárt struktúrákat gyakran vizsgálják komputertomográfiával. Az ionizáló sugárzás veszélyeit figyelembe véve az ismételt vizsgálatok hatványozottan növelik a sugárérzékeny szövetek károsodásának kockázatát. A szerzők összehasonlítják a hagyományos és a cone-beam komputertomográfiát, és bemutatják a cone-beam komputertomográfia fül-orr-gégészeti képalkotásban betöltött helyét, előnyeit és korlátait. Összefoglalják a nemzetközi szakirodalomból és saját betegeik vizsgálatából származó tapasztalataikat. Eredményeik szerint a hagyományos komputertomográfia effektív sugárdózisának töredékével nagy térbeli felbontású vizsgálatok végezhetők tetszőleges síkú és térbeli rekonstrukciókkal. A cone-beam komputertomográfia megfelelő indikációban kiváló vizsgálómódszer a fül-orr-gégészeti diagnosztikában. Lényegesen alacsonyabb sugárterhelése miatt a hagyományos komputertomográfia alternatívája, valamint a per- és posztoperatív betegkövetés hatékony eszköze is lehet, különösen az ismételt komputertomográfiás vizsgálatot igénylő esetekben. Orv. Hetil., 2016, 157(2), 52–58. Abstract Accurate diagnosis and preoperative planning in modern otorhinolaryngology is strongly supported by imaging with enhanced visualization. Computed tomography is often used to examine structures within bone frameworks. Given the hazards of ionizing radiation, repetitive imaging studies exponentially increase the risk of damages to radiosensitive tissues. The authors compare multislice and cone-beam computed tomography and determine the role, advantages and disadvantages of cone-beam computed tomography in otorhinolaryngological imaging. They summarize the knowledge from the international literature and their individual imaging studies. They conclude that cone-beam computed tomography enables high-resolution imaging and reconstruction in any optional plane and in space with considerably lower effective radiation dose. Cone-beam computed tomography with appropriate indications proved to be an excellent diagnostic tool in otorhinolaryngological imaging. It makes an alternative to multislice computed tomography and it is an effective tool in perioperative and postoperative follow-up, especially in those cases which necessitate repetitive imaging with computed tomography. Orv. Hetil., 2016, 157(2), 52–58.
- 1 January 2016
- Published by Akademiai Kiado Zrt. in Orvosi Hetilap
- Vol. 157 (2) , 52-58
Open AccessA cone-beam komputertomográfia alkalmazása a fül-orr-gégészeti képalkotásban
Absztrakt A modern fül-orr-gégészetben a pontos diagnózis és a korrekt műtéti tervezés alapja a részletes vizualizációt eredményező képalkotás. A csontos keretbe zárt struktúrákat gyakran vizsgálják komputertomográfiával. Az ionizáló sugárzás veszélyeit figyelembe véve az ismételt vizsgálatok hatványozottan növelik a sugárérzékeny szövetek károsodásának kockázatát. A szerzők összehasonlítják a hagyományos és a cone-beam komputertomográfiát, és bemutatják a cone-beam komputertomográfia fül-orr-gégészeti képalkotásban betöltött helyét, előnyeit és korlátait. Összefoglalják a nemzetközi szakirodalomból és saját betegeik vizsgálatából származó tapasztalataikat. Eredményeik szerint a hagyományos komputertomográfia effektív sugárdózisának töredékével nagy térbeli felbontású vizsgálatok végezhetők tetszőleges síkú és térbeli rekonstrukciókkal. A cone-beam komputertomográfia megfelelő indikációban kiváló vizsgálómódszer a fül-orr-gégészeti diagnosztikában. Lényegesen alacsonyabb sugárterhelése miatt a hagyományos komputertomográfia alternatívája, valamint a per- és posztoperatív betegkövetés hatékony eszköze is lehet, különösen az ismételt komputertomográfiás vizsgálatot igénylő esetekben. Orv. Hetil., 2016, 157(2), 52–58. Abstract Accurate diagnosis and preoperative planning in modern otorhinolaryngology is strongly supported by imaging with enhanced visualization. Computed tomography is often used to examine structures within bone frameworks. Given the hazards of ionizing radiation, repetitive imaging studies exponentially increase the risk of damages to radiosensitive tissues. The authors compare multislice and cone-beam computed tomography and determine the role, advantages and disadvantages of cone-beam computed tomography in otorhinolaryngological imaging. They summarize the knowledge from the international literature and their individual imaging studies. They conclude that cone-beam computed tomography enables high-resolution imaging and reconstruction in any optional plane and in space with considerably lower effective radiation dose. Cone-beam computed tomography with appropriate indications proved to be an excellent diagnostic tool in otorhinolaryngological imaging. It makes an alternative to multislice computed tomography and it is an effective tool in perioperative and postoperative follow-up, especially in those cases which necessitate repetitive imaging with computed tomography. Orv. Hetil., 2016, 157(2), 52–58.
- 9 November 2010
- Vol. 69 (1) , 20-3
Intranasal PUVA phototherapy in nasal polyposis--a pilot study.
Nasal polyposis (NP) affects 4% of the general population, representing a major health problem. In spite of complex (surgical and medical) treatment, the relapse rate is high and it has a negative impact on the quality of life. Recently we found that intranasal photochemotherapy with ultraviolet A light (PUVA) is effective in allergic rhinitis. In the present study PUVA was administered for 6 weeks in 7 patients with NP. Nasal lavages were performed in all patients before and at the end of the treatment; from four patients a biopsy specimen was also collected. Eosinophils significantly decreased in patients with NP and slightly in a patient who had associated aspirin sensitivity. IL-5 and eosinophil cationic protein (ECP) levels showed a decreasing trend in patients with NP and an increasing trend in patients with associated aspirin sensitivity. Our results suggest that intranasal PUVA might represent a future therapeutic method in a subset of patients with NP.
- 9 November 2010
- Vol. 69 (1) , 20-3
Intranasal PUVA phototherapy in nasal polyposis--a pilot study.
Nasal polyposis (NP) affects 4% of the general population, representing a major health problem. In spite of complex (surgical and medical) treatment, the relapse rate is high and it has a negative impact on the quality of life. Recently we found that intranasal photochemotherapy with ultraviolet A light (PUVA) is effective in allergic rhinitis. In the present study PUVA was administered for 6 weeks in 7 patients with NP. Nasal lavages were performed in all patients before and at the end of the treatment; from four patients a biopsy specimen was also collected. Eosinophils significantly decreased in patients with NP and slightly in a patient who had associated aspirin sensitivity. IL-5 and eosinophil cationic protein (ECP) levels showed a decreasing trend in patients with NP and an increasing trend in patients with associated aspirin sensitivity. Our results suggest that intranasal PUVA might represent a future therapeutic method in a subset of patients with NP.