Małgorzata Basińska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Małgorzata Basińska has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Halina Koczyk
Faculty of Environmental Engineering and Energy, Institute of Environmental Engineering and Building Installations, Poznan University of Technology, Berdychowo 4, 60-965 Poznań, Poland
7 shared publications - Katarzyna Ratajczak
Faculty of Environmental Engineering and Energy, Institute of Environmental Engineering and Building Installations, Poznan University of Technology, Rychlewskiego 1, 61-131 Poznań, Poland
5 shared publications - Michał Michałkiewicz
Institute of Environmental Engineering and Building Installations, Faculty of Environmental Engineering and Energy, Poznan University of Technology, 60-965 Poznań, Poland
5 shared publications - Dobrosława Kaczorek
Thermal Physics, Acoustics and Environment Department, Building Research Institute (ITB), Filtrowa 1 Str., 00-611 Warsaw, Poland
4 shared publications - Joanna Kubiak
Doctoral School of the Poznan University of Technology, 60-965 Poznan, Poland
2 shared publications Aleksandra Błotnicka-Smyk
Mercury Engineering Polska Sp. z o.o., 87 Promienista St., Poznan 60-101, Poland
1 shared publication
Latest Publications
- Open Access
Impact of Moisture-Buffering Materials and Time-Averaging of Infiltration Rate on Prediction of Indoor Air Humidity
The moisture buffering properties of materials and actual air exchange are crucial for indoor conditions in buildings. Consequently, precise material data and an adequate model of highly variable outdoor air infiltration are essential for computer-based design simulations. This study quantifies how internal cladding materials and infiltration time-averaging affect indoor relative humidity prediction. Three internal finishing variants were analysed: painted gypsum plasterboard, painted clay board, and unpainted clay board, the latter characterised experimentally by a practical moisture buffer value of 1.88 g/(m2·%RH). Three moisture-load scenarios were considered, resulting in 27 simulation cases. Hourly infiltration rates were calculated in the DesignBuilder software and then converted into annual, monthly, and daily averages for WUFI Plus 3.X simulations. The annual mean infiltration rate was 0.117 h−1, while selected daily means ranged from 0.03 to 0.60 h−1. Passive moisture buffering, especially the unpainted clay board, reduced short-term RH fluctuations but did not entirely compensate for insufficient moisture removal. Surface finishing has a decisive influence on the practical performance of hygroscopic materials. Under high moisture gains, median RH reached about 69.5%, and predictions became sensitive to infiltration resolution. Annual averaging may therefore be sufficient for low moisture loads, whereas daily values are required when short-term moisture peaks and moisture buffering effects are relevant.
Open AccessImpact of Moisture-Buffering Materials and Time-Averaging of Infiltration Rate on Prediction of Indoor Air Humidity
The moisture buffering properties of materials and actual air exchange are crucial for indoor conditions in buildings. Consequently, precise material data and an adequate model of highly variable outdoor air infiltration are essential for computer-based design simulations. This study quantifies how internal cladding materials and infiltration time-averaging affect indoor relative humidity prediction. Three internal finishing variants were analysed: painted gypsum plasterboard, painted clay board, and unpainted clay board, the latter characterised experimentally by a practical moisture buffer value of 1.88 g/(m2·%RH). Three moisture-load scenarios were considered, resulting in 27 simulation cases. Hourly infiltration rates were calculated in the DesignBuilder software and then converted into annual, monthly, and daily averages for WUFI Plus 3.X simulations. The annual mean infiltration rate was 0.117 h−1, while selected daily means ranged from 0.03 to 0.60 h−1. Passive moisture buffering, especially the unpainted clay board, reduced short-term RH fluctuations but did not entirely compensate for insufficient moisture removal. Surface finishing has a decisive influence on the practical performance of hygroscopic materials. Under high moisture gains, median RH reached about 69.5%, and predictions became sensitive to infiltration resolution. Annual averaging may therefore be sufficient for low moisture loads, whereas daily values are required when short-term moisture peaks and moisture buffering effects are relevant.
- Open Access
- 16 May 2025
- Published by MDPI AG in Atmosphere
- Vol. 16 (5) , 600
Experience from Research on Indoor and Outdoor Air Quality in the Poznań Agglomeration
This article explores how the location of a building in an urban area, the level of external air pollution, and the way a residence is used can affect indoor air quality. To assess this, this study used measurements of physical and chemical pollutants, as well as microbiological measurements, including counts of various bacteria and microscopic fungi. These included counts of mesophilic and psychrophilic bacteria, mannitol-positive and mannitol-negative Staphylococcus, Actinobacteria, Pseudomonas fluorescens, and microscopic fungi. The research involved analysing indoor and outdoor air quality in 38 selected spaces within buildings in the city of Poznań during the heating season. The study found that the eastern part of the city showed the highest levels of fungal contamination in the external environment. Furthermore, distinct differences were observed between the presence of microorganisms indoors and outdoors based on the results of bacterial and fungal aerosol studies. The authors advocate for including microbiological studies as part of standard air quality assessment indicators to reveal the extent and source of contamination, as similar issues may be present in cities around the world.
- 16 May 2025
- Published by MDPI AG in Atmosphere
- Vol. 16 (5) , 600
Open AccessExperience from Research on Indoor and Outdoor Air Quality in the Poznań Agglomeration
This article explores how the location of a building in an urban area, the level of external air pollution, and the way a residence is used can affect indoor air quality. To assess this, this study used measurements of physical and chemical pollutants, as well as microbiological measurements, including counts of various bacteria and microscopic fungi. These included counts of mesophilic and psychrophilic bacteria, mannitol-positive and mannitol-negative Staphylococcus, Actinobacteria, Pseudomonas fluorescens, and microscopic fungi. The research involved analysing indoor and outdoor air quality in 38 selected spaces within buildings in the city of Poznań during the heating season. The study found that the eastern part of the city showed the highest levels of fungal contamination in the external environment. Furthermore, distinct differences were observed between the presence of microorganisms indoors and outdoors based on the results of bacterial and fungal aerosol studies. The authors advocate for including microbiological studies as part of standard air quality assessment indicators to reveal the extent and source of contamination, as similar issues may be present in cities around the world.
- 28 March 2025
- Published by Elsevier in Building and Environment
- Vol. 277
A novel method for analysing indoor radon concentration measurements
- 28 March 2025
- Published by Elsevier in Building and Environment
- Vol. 277
A novel method for analysing indoor radon concentration measurements
- Open Access
Effect of Using Moisture-Buffering Finishing Materials and DCV Systems on Environmental Comfort and Energy Consumption in Buildings
One of the technical solutions to improve indoor thermal comfort and reduce energy consumption in buildings is the use of demand-controlled ventilation (DCV) systems. The choice of the control method becomes more important when the walls in the room are finished with moisture-buffering materials. This study explores the impact of four DCV system control scenarios (control of temperature, relative humidity, and carbon dioxide concentration for two different supply airflows to the room) combined with various indoor moisture-buffering materials (gypsum board and cement–lime plaster) on the variability of indoor air quality parameters, thermal comfort, and energy. The analysis was performed by computer simulation using WUFI Plus v.3.1.0.3 software for whole-building hydrothermal analysis. Control-based systems that maintain appropriate relative humidity levels were found to be the most favourable for localised comfort and were more effective in terms of energy consumption for heating and cooling without humidification and dehumidification. This research also revealed that the moisture-buffering effect of finishing materials can passively contribute to enhancing indoor air quality, regardless of the room’s purpose. However, higher energy consumption for heating was observed for better moisture-buffering materials.
Open AccessEffect of Using Moisture-Buffering Finishing Materials and DCV Systems on Environmental Comfort and Energy Consumption in Buildings
One of the technical solutions to improve indoor thermal comfort and reduce energy consumption in buildings is the use of demand-controlled ventilation (DCV) systems. The choice of the control method becomes more important when the walls in the room are finished with moisture-buffering materials. This study explores the impact of four DCV system control scenarios (control of temperature, relative humidity, and carbon dioxide concentration for two different supply airflows to the room) combined with various indoor moisture-buffering materials (gypsum board and cement–lime plaster) on the variability of indoor air quality parameters, thermal comfort, and energy. The analysis was performed by computer simulation using WUFI Plus v.3.1.0.3 software for whole-building hydrothermal analysis. Control-based systems that maintain appropriate relative humidity levels were found to be the most favourable for localised comfort and were more effective in terms of energy consumption for heating and cooling without humidification and dehumidification. This research also revealed that the moisture-buffering effect of finishing materials can passively contribute to enhancing indoor air quality, regardless of the room’s purpose. However, higher energy consumption for heating was observed for better moisture-buffering materials.
- Open Access
- 12 October 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (10) , 1664
Analysis of the Radon Concentration in Selected Rooms of Buildings in Poznan County
This article presents the results of the research carried out in selected rooms of buildings located in Poznan. According to the measurements, the highest average radon concentration in the buildings in Poznan County was at the level of 130 ± 32 Bqm−3. The lowest mean concentration was 31 ± 8 Bqm−3 and was measured in a seven-year-old educational institution. Based on the performed measurements, non-uniformity of the correlation between the radon concentration and temperature and humidity was observed. For all the measurement sites where volatile organic compounds were counted, a positive correlation with radon was observed (rxy = 0.31, p < 0.001). A negative correlation was obtained (rxy = −0.15, p < 0.001) between the concentration of radon and the concentration of carbon dioxide. Based on the analysis of the research conducted, it was found that the concentration of radon in a given room depends on many factors, such as temperature, humidity, and room usage profile.
- 12 October 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (10) , 1664
Open AccessAnalysis of the Radon Concentration in Selected Rooms of Buildings in Poznan County
This article presents the results of the research carried out in selected rooms of buildings located in Poznan. According to the measurements, the highest average radon concentration in the buildings in Poznan County was at the level of 130 ± 32 Bqm−3. The lowest mean concentration was 31 ± 8 Bqm−3 and was measured in a seven-year-old educational institution. Based on the performed measurements, non-uniformity of the correlation between the radon concentration and temperature and humidity was observed. For all the measurement sites where volatile organic compounds were counted, a positive correlation with radon was observed (rxy = 0.31, p < 0.001). A negative correlation was obtained (rxy = −0.15, p < 0.001) between the concentration of radon and the concentration of carbon dioxide. Based on the analysis of the research conducted, it was found that the concentration of radon in a given room depends on many factors, such as temperature, humidity, and room usage profile.
- Open Access
- 30 November 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (12) , 1606
Effect of Air Purifier Use in the Classrooms on Indoor Air Quality—Case Study
Dissatisfaction with indoor air quality is common even in relatively new or renovated Polish school buildings. To improve air quality in educational buildings, portable devices have seen increased use, for which manufacturers guarantee a high level of indoor air purification. However, their optimized operation largely depends on their correct use. The aim of this article was to determine the effectiveness of air purification in a primary school using an air purification device with an analysis of the classroom indoor air quality (IAQ). Two criteria were used, microbiological and particulate matter concentration. Measurements were made before device installation and during its continuous operation, and before and after lessons on chosen days. Measurements related to IAQ did not detect clear differences in the analyzed measurement periods. For microbiological contamination, in the morning before lessons, the total count for all bacteria and microscopic fungi was definitely lower than after lessons. Comparing the periods before and after device installation, no clear tendency for reducing the bacteria count or microscopic fungi occurred during air purifier operation, nor was there any noticeable trend in the reduction of particulate matter. There was no improvement in air quality in the classrooms during the operation of the purification devices.
- 30 November 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (12) , 1606
Open AccessEffect of Air Purifier Use in the Classrooms on Indoor Air Quality—Case Study
Dissatisfaction with indoor air quality is common even in relatively new or renovated Polish school buildings. To improve air quality in educational buildings, portable devices have seen increased use, for which manufacturers guarantee a high level of indoor air purification. However, their optimized operation largely depends on their correct use. The aim of this article was to determine the effectiveness of air purification in a primary school using an air purification device with an analysis of the classroom indoor air quality (IAQ). Two criteria were used, microbiological and particulate matter concentration. Measurements were made before device installation and during its continuous operation, and before and after lessons on chosen days. Measurements related to IAQ did not detect clear differences in the analyzed measurement periods. For microbiological contamination, in the morning before lessons, the total count for all bacteria and microscopic fungi was definitely lower than after lessons. Comparing the periods before and after device installation, no clear tendency for reducing the bacteria count or microscopic fungi occurred during air purifier operation, nor was there any noticeable trend in the reduction of particulate matter. There was no improvement in air quality in the classrooms during the operation of the purification devices.
- Open Access
The Way of Usage and Location in a Big City Agglomeration as Impact Factors of the Nurseries Indoor Air Quality
The quality of outdoor air in many places, especially in urbanized areas, is bad; therefore, a series of studies aimed at assessing the impact of outdoor air parameters on indoor air quality was conducted. Four nurseries (three buildings) located in different parts of Poznań, Poland were selected as research sites. During the research period, the concentrations of CO2, PM2.5, and PM10 inside and outside the buildings over time were analyzed. Measurements outside the buildings were supplemented with an analysis of traffic near nurseries and an assessment of pollutant emissions from vehicles of various categories. Measurements were conducted during the COVID-19 pandemic in a weekly series during winter (December)—(W), spring (April)—(S), and at the end of spring (June)—(LS). Testing and analyses indicated poor indoor air quality in three out of four nurseries. To ensure indoor air quality at the proper level, it is necessary to supply rooms with outside air. Ventilating rooms by airing, when the outside air is polluted, reduces the CO2 concentration but worsens the indoor air quality in terms of particulate matter (PM). Seasonality in the concentration of particulate matter in outdoor air and its connection with the outside air temperature was noticed. No relationship between traffic and the values of PM10 and CO2 concentrations inside nurseries was observed.
Open AccessThe Way of Usage and Location in a Big City Agglomeration as Impact Factors of the Nurseries Indoor Air Quality
The quality of outdoor air in many places, especially in urbanized areas, is bad; therefore, a series of studies aimed at assessing the impact of outdoor air parameters on indoor air quality was conducted. Four nurseries (three buildings) located in different parts of Poznań, Poland were selected as research sites. During the research period, the concentrations of CO2, PM2.5, and PM10 inside and outside the buildings over time were analyzed. Measurements outside the buildings were supplemented with an analysis of traffic near nurseries and an assessment of pollutant emissions from vehicles of various categories. Measurements were conducted during the COVID-19 pandemic in a weekly series during winter (December)—(W), spring (April)—(S), and at the end of spring (June)—(LS). Testing and analyses indicated poor indoor air quality in three out of four nurseries. To ensure indoor air quality at the proper level, it is necessary to supply rooms with outside air. Ventilating rooms by airing, when the outside air is polluted, reduces the CO2 concentration but worsens the indoor air quality in terms of particulate matter (PM). Seasonality in the concentration of particulate matter in outdoor air and its connection with the outside air temperature was noticed. No relationship between traffic and the values of PM10 and CO2 concentrations inside nurseries was observed.
- Open Access
Economic and Energy Analysis of Building Retrofitting Using Internal Insulations
The energy-saving requirements for most buildings focus on improving the insulation and airtightness of a building’s envelope. In this paper, the authors have investigated the effect of additional internal insulation on energy consumption for heating and cooling in a residential building. Energy performance analyses were conducted for buildings with four internal thermal insulation systems in three locations using the WUFI Plus software. The Global Cost Method and Simply Pay Back Time have been used to assess and compare the economic viability of the retrofit systems. The results show that, in relation to energy, retrofitting with internal wall insulation can be an alternative to traditional external insulation. The assessment of internal insulation for low-energy buildings, however, cannot be conducted based on economic criteria. The usual approach of Simply Pay Back Time has exceptionally long payback time, which is unacceptable. In turn, the Global Cost Method, can only be used to compare the applied materials. With high investment costs, thermo-modernization improvements do not contribute to significant savings. The conditions of thermal comfort and the analysis of temperature and steam pressure play a decisive role in assessing this type of solution.
Open AccessEconomic and Energy Analysis of Building Retrofitting Using Internal Insulations
The energy-saving requirements for most buildings focus on improving the insulation and airtightness of a building’s envelope. In this paper, the authors have investigated the effect of additional internal insulation on energy consumption for heating and cooling in a residential building. Energy performance analyses were conducted for buildings with four internal thermal insulation systems in three locations using the WUFI Plus software. The Global Cost Method and Simply Pay Back Time have been used to assess and compare the economic viability of the retrofit systems. The results show that, in relation to energy, retrofitting with internal wall insulation can be an alternative to traditional external insulation. The assessment of internal insulation for low-energy buildings, however, cannot be conducted based on economic criteria. The usual approach of Simply Pay Back Time has exceptionally long payback time, which is unacceptable. In turn, the Global Cost Method, can only be used to compare the applied materials. With high investment costs, thermo-modernization improvements do not contribute to significant savings. The conditions of thermal comfort and the analysis of temperature and steam pressure play a decisive role in assessing this type of solution.
- Open Access
The Well-Being of Children in Nurseries Does Not Have to Be Expensive: The Real Costs of Maintaining Low Carbon Dioxide Concentrations in Nurseries
There are different standards and regulations outlining the requirements regarding building air quality as well as in nurseries. These requirements specify air stream supplies and carbon dioxide concentration levels, both of which ensure proper indoor air quality. Mechanical ventilation should be used to maintain acceptable carbon dioxide levels. This article analyses the use of ventilation equipped with decentralized units, which helps secure the well-being of children. This paper proposes and evaluates economically affordable ventilation units. An algorithm for selecting the size of the devices is described by the supplied air stream depending on the number of children present at the nursery. A method of transferring the investment costs related to the assembly of the given units to the parents is proposed. Air quality in terms of CO2 concentrations was based on the following levels: 750 ppm, 1000 ppm, 1500 ppm. This assessment also includes the investment costs resulting from device usage and the costs of electricity consumed by the fans. These results showed the additional costs that assure the air quality improvement do not have to be high (45 PLN/month, ~10 EUR/month) per child attending the nursery. A 3% tuition increase returns the investment costs on mechanical ventilation within four years.
Open AccessThe Well-Being of Children in Nurseries Does Not Have to Be Expensive: The Real Costs of Maintaining Low Carbon Dioxide Concentrations in Nurseries
There are different standards and regulations outlining the requirements regarding building air quality as well as in nurseries. These requirements specify air stream supplies and carbon dioxide concentration levels, both of which ensure proper indoor air quality. Mechanical ventilation should be used to maintain acceptable carbon dioxide levels. This article analyses the use of ventilation equipped with decentralized units, which helps secure the well-being of children. This paper proposes and evaluates economically affordable ventilation units. An algorithm for selecting the size of the devices is described by the supplied air stream depending on the number of children present at the nursery. A method of transferring the investment costs related to the assembly of the given units to the parents is proposed. Air quality in terms of CO2 concentrations was based on the following levels: 750 ppm, 1000 ppm, 1500 ppm. This assessment also includes the investment costs resulting from device usage and the costs of electricity consumed by the fans. These results showed the additional costs that assure the air quality improvement do not have to be high (45 PLN/month, ~10 EUR/month) per child attending the nursery. A 3% tuition increase returns the investment costs on mechanical ventilation within four years.
- Open Access
Building Thermo-Modernisation Solution Based on the Multi-Objective Optimisation Method
This study presents a multi-objective optimisation of building thermo-modernisation for multi-family buildings. The applied model has considered alternative solutions for insulation materials, with different thicknesses and different types of windows. The weighted sum method was applied to find a solution considering the minimisation of global cost, primary energy ratio and CO2 emissions. The solutions were compared for a building equipped with natural ventilation, and with mechanical supply—exhaust ventilation. In reference to the two considered types of ventilation, we analysed how the modification of an insulation thickness, its type and the type of installed windows, can be converted into individual evaluation criteria. The weights of the considered criteria were changed; however, this had no influence on the optimal solution. If the aim is to achieve the standards of zero-energy buildings, natural ventilation cannot be applied, despite the high value of thermal insulation of the building envelopes. Alternative solutions exist for buildings with natural ventilation and mechanical ventilation with heat recovery, where the primary energy ratio is the same for both, but the global costs are different. The additional energy and environmental input for the production of materials and elements to be replaced are insignificant in comparison to the savings brought about by thermo-modernisation.
Open AccessBuilding Thermo-Modernisation Solution Based on the Multi-Objective Optimisation Method
This study presents a multi-objective optimisation of building thermo-modernisation for multi-family buildings. The applied model has considered alternative solutions for insulation materials, with different thicknesses and different types of windows. The weighted sum method was applied to find a solution considering the minimisation of global cost, primary energy ratio and CO2 emissions. The solutions were compared for a building equipped with natural ventilation, and with mechanical supply—exhaust ventilation. In reference to the two considered types of ventilation, we analysed how the modification of an insulation thickness, its type and the type of installed windows, can be converted into individual evaluation criteria. The weights of the considered criteria were changed; however, this had no influence on the optimal solution. If the aim is to achieve the standards of zero-energy buildings, natural ventilation cannot be applied, despite the high value of thermal insulation of the building envelopes. Alternative solutions exist for buildings with natural ventilation and mechanical ventilation with heat recovery, where the primary energy ratio is the same for both, but the global costs are different. The additional energy and environmental input for the production of materials and elements to be replaced are insignificant in comparison to the savings brought about by thermo-modernisation.