Endrik Arumägi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Endrik Arumägi has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Targo Kalamees
Tallinn University of Technology, Nearly Zero Energy Buildings Research Group, Ehitajate tee 5, 19086 Tallinn, Estonia
3 shared publications- Targo Kalamees
Department of Civil Engineering and Architecture, Tallinn University of Technology, Tallinn, Estonia
2 shared publications Anna Donarelli
Uppsala University, Sweden
1 shared publication- Juha Jokisalo
Aalto University, Finland
1 shared publication Kai Sirén
Aalto University, Finland
1 shared publicationLari Eskola
Aalto University, Finland
1 shared publication
Latest Publications
- Open Access
Cost and Energy Reduction of a New nZEB Wooden Building
The current study demonstrates the possibilities of reducing energy use and construction costs and provides evidence that wooden nearly-zero-energy buildings (nZEB) are technically possible at affordable construction costs by using novel design processes and procurement models that enable scalable and modular production. The energy efficiency solutions were derived by increasing/decreasing the insulation value of the building envelope in successive steps. Financial calculations were based on the investment needed to achieve the nearly-zero-energy levels. Overall, many opportunities exist to decrease the cost and energy use compared to the current (pre-nZEB) practice because the net present value can change up to 150 €/m² on the same energy performance indicator (EPI) level. The EPI in the cost-even range was reached by combining a ground-source heat pump (between 115 and 128 kWh/(m2·a)) and efficient district heating (between 106 and 124 kWh/(m2·a)). As energy efficiency decreases, improving energy efficiency becomes more expensive by insulation measures. Throughout the EPI range the most cost efficient was investment in the improvement of the thermal transmittance of windows (3–13 €/(kWh/(m2·a))) while investments in other building envelope parts were less effective (4–80 €/(kWh/(m2·a))). If these were possible to install, photovoltaic (PV) panels installed to the roof would be the cheapest solution to improve the energy performance. Integrated project delivery procurement (design and construction together) and the use of prefabricated wooden structures reduced the constructing cost by half (from ~2700 €/net m2 to 1390 €/net m2) and helped to keep the budget within limits.
Open AccessCost and Energy Reduction of a New nZEB Wooden Building
The current study demonstrates the possibilities of reducing energy use and construction costs and provides evidence that wooden nearly-zero-energy buildings (nZEB) are technically possible at affordable construction costs by using novel design processes and procurement models that enable scalable and modular production. The energy efficiency solutions were derived by increasing/decreasing the insulation value of the building envelope in successive steps. Financial calculations were based on the investment needed to achieve the nearly-zero-energy levels. Overall, many opportunities exist to decrease the cost and energy use compared to the current (pre-nZEB) practice because the net present value can change up to 150 €/m² on the same energy performance indicator (EPI) level. The EPI in the cost-even range was reached by combining a ground-source heat pump (between 115 and 128 kWh/(m2·a)) and efficient district heating (between 106 and 124 kWh/(m2·a)). As energy efficiency decreases, improving energy efficiency becomes more expensive by insulation measures. Throughout the EPI range the most cost efficient was investment in the improvement of the thermal transmittance of windows (3–13 €/(kWh/(m2·a))) while investments in other building envelope parts were less effective (4–80 €/(kWh/(m2·a))). If these were possible to install, photovoltaic (PV) panels installed to the roof would be the cheapest solution to improve the energy performance. Integrated project delivery procurement (design and construction together) and the use of prefabricated wooden structures reduced the constructing cost by half (from ~2700 €/net m2 to 1390 €/net m2) and helped to keep the budget within limits.
- Open Access
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 13002
Cost reduction of the new NZEB Wooden building – case study of the kindergarten in Estonia
In this study the cost changes caused by the implementation of the nZEB solutions are calculated. The energy demand of a building was calculated according to the methodology for calculating the energy efficiency of buildings, using dynamic energy simulations. The financial calculations are based on the methodology described in Delegated Regulation (EU) No 244/2012 of the European Commission. The simulations and calculations for assessing the cost-effectiveness of technical solutions are based on the selected sample building. The energy efficiency solutions are derived by increasing/decreasing the insulation value of the building envelope in subsequent steps. Financial calculations were based on the investment needed to achieve the nearly zero-energy levels. The results for different combinations vary to a large degree. According to regulations new building must fulfill the low energy building (EPI class “B”) requirement without local production. The EPI value to fulfill the requirement in the cost-even range is reached in case of the GSHP and efficient DH. In case of the GSHP and efficient DH also the cost-optimal point is in the EPI class “B”. Overall the minimum ΔNPV values stay below the zero line in all the cases offering a range of opportunities to choose combinations to reach lover EPI compared to base case. The results of cost-effectiveness calculations for selected building with different combinations of structural solutions and heat sources show the possible different scenarios to reach nZEB level and the possible cost reduction.
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 13002
Open AccessCost reduction of the new NZEB Wooden building – case study of the kindergarten in Estonia
In this study the cost changes caused by the implementation of the nZEB solutions are calculated. The energy demand of a building was calculated according to the methodology for calculating the energy efficiency of buildings, using dynamic energy simulations. The financial calculations are based on the methodology described in Delegated Regulation (EU) No 244/2012 of the European Commission. The simulations and calculations for assessing the cost-effectiveness of technical solutions are based on the selected sample building. The energy efficiency solutions are derived by increasing/decreasing the insulation value of the building envelope in subsequent steps. Financial calculations were based on the investment needed to achieve the nearly zero-energy levels. The results for different combinations vary to a large degree. According to regulations new building must fulfill the low energy building (EPI class “B”) requirement without local production. The EPI value to fulfill the requirement in the cost-even range is reached in case of the GSHP and efficient DH. In case of the GSHP and efficient DH also the cost-optimal point is in the EPI class “B”. Overall the minimum ΔNPV values stay below the zero line in all the cases offering a range of opportunities to choose combinations to reach lover EPI compared to base case. The results of cost-effectiveness calculations for selected building with different combinations of structural solutions and heat sources show the possible different scenarios to reach nZEB level and the possible cost reduction.
- 2 September 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 22 (7) , 1039-1049
Design of the first net-zero energy buildings in Estonia
In Estonia, comprehensive regulation establishes the methods for calculating the indoor climate and energy performance of buildings to prove their compliance with minimum requirements. The definition of a nearly zero-energy building and a net-zero energy building, and the methodology for the calculation of the energy performance of the buildings in Estonia are explained. The problems and results of the design process of the first zero-energy building in Estonia are described through a case study. The current study showed that it is possible to reach zero-energy building levels in Estonia by careful and detailed designs of the energy performance of a building. More thorough analyses are needed in the very first stage of the design to find suitable solutions and possible compromises between architecture and energy efficiency. In any case, well-insulated buildings, effective building service systems, and local electricity production on-site is needed for zero-energy building. Finally this article discusses the problems and limitations of the regulations influencing the motivation and actions needed to achieve zero-energy buildings. The study shows the influence of the different parts of the building on the balance of the energy consumption and utilization, and on the energy performance of the building to achieve zero-energy building status.
- 2 September 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 22 (7) , 1039-1049
Design of the first net-zero energy buildings in Estonia
In Estonia, comprehensive regulation establishes the methods for calculating the indoor climate and energy performance of buildings to prove their compliance with minimum requirements. The definition of a nearly zero-energy building and a net-zero energy building, and the methodology for the calculation of the energy performance of the buildings in Estonia are explained. The problems and results of the design process of the first zero-energy building in Estonia are described through a case study. The current study showed that it is possible to reach zero-energy building levels in Estonia by careful and detailed designs of the energy performance of a building. More thorough analyses are needed in the very first stage of the design to find suitable solutions and possible compromises between architecture and energy efficiency. In any case, well-insulated buildings, effective building service systems, and local electricity production on-site is needed for zero-energy building. Finally this article discusses the problems and limitations of the regulations influencing the motivation and actions needed to achieve zero-energy buildings. The study shows the influence of the different parts of the building on the balance of the energy consumption and utilization, and on the energy performance of the building to achieve zero-energy building status.
- 1 June 2015
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 14 (1) , 11-26
Airtightness, Air Exchange and Energy Performance in Historic Residential Buildings with Different Structures
Old buildings that represent and maintain historic values often have poor indoor conditions and energy efficiency. The aim of this work was to evaluate the influence of building structures on airtightness and energy performance of certain historic building types. In this study on-site measurements, dynamic simulation and questionnaires were used. Significant differences between the levels of the airtightness of the historic houses exist in the studied region. No statistically significant correlation was found between the structure types and the envelope tightness. The typical air leakage places of the studied houses were at the junctions of the envelope structures. Measured air exchange rates indicated that the level of ventilation is insufficient in some of the houses while some are too leaky. If the airtightness of the naturally ventilated house is improved, the acceptable ventilation rate has to be guaranteed. Tightening the envelope and moving from natural to mechanical ventilation was the most effective way to improve the indoor conditions and energy performance.
- 1 June 2015
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 14 (1) , 11-26
Airtightness, Air Exchange and Energy Performance in Historic Residential Buildings with Different Structures
Old buildings that represent and maintain historic values often have poor indoor conditions and energy efficiency. The aim of this work was to evaluate the influence of building structures on airtightness and energy performance of certain historic building types. In this study on-site measurements, dynamic simulation and questionnaires were used. Significant differences between the levels of the airtightness of the historic houses exist in the studied region. No statistically significant correlation was found between the structure types and the envelope tightness. The typical air leakage places of the studied houses were at the junctions of the envelope structures. Measured air exchange rates indicated that the level of ventilation is insufficient in some of the houses while some are too leaky. If the airtightness of the naturally ventilated house is improved, the acceptable ventilation rate has to be guaranteed. Tightening the envelope and moving from natural to mechanical ventilation was the most effective way to improve the indoor conditions and energy performance.
- Open Access
- 13 May 2015
- Published by Estonian Academy Publishers in Proceedings of the Estonian Academy of Sciences
- Vol. 64 (2) , 146-156
Indoor climate conditions and hygrothermal loads in historic wooden apartment buildings in cold climates; pp. 146–156
To design and assess indoor climate, thermal comfort, and the hygrothermal performance of a historic building it is essential to obtain data on the indoor temperature and humidity conditions. This paper analyses indoor climate conditions in historic wooden apartment buildings in Estonia and presents an applicable hygrothermal load model for designers. The average indoor temperature of 41 apartments in historic wooden apartment buildings was 21.0 °C in winter and 24.5 °C in summer. Using the indoor climate category III of the standard EN 15251, it was found that the temperature was outside the target values in 83% of the apartments in winter and in 25% in summer. Throughout the year, the indoor temperature was below the target values during 20% of the time while in winter it was above the target values during 4% of the time. Variations in indoor temperature reflect occupants’ main complaints about unstable temperature and cold floors during the winter period. The daily average moisture excess was 3.3 g/m3 during the cold period and 0.6 g/m3 during the warm period at the average air change rate of 0.56 h–1 and 0.79 h–1, respectively. Moisture generation indoors was 60 g/h at the average living density of 26 m2/person in the historic wooden apartment buildings. For stochastic analyses in historic wooden buildings, we developed an indoor hygrothermal load model that is in good agreement with measured results.
- 13 May 2015
- Published by Estonian Academy Publishers in Proceedings of the Estonian Academy of Sciences
- Vol. 64 (2) , 146-156
Open AccessIndoor climate conditions and hygrothermal loads in historic wooden apartment buildings in cold climates; pp. 146–156
To design and assess indoor climate, thermal comfort, and the hygrothermal performance of a historic building it is essential to obtain data on the indoor temperature and humidity conditions. This paper analyses indoor climate conditions in historic wooden apartment buildings in Estonia and presents an applicable hygrothermal load model for designers. The average indoor temperature of 41 apartments in historic wooden apartment buildings was 21.0 °C in winter and 24.5 °C in summer. Using the indoor climate category III of the standard EN 15251, it was found that the temperature was outside the target values in 83% of the apartments in winter and in 25% in summer. Throughout the year, the indoor temperature was below the target values during 20% of the time while in winter it was above the target values during 4% of the time. Variations in indoor temperature reflect occupants’ main complaints about unstable temperature and cold floors during the winter period. The daily average moisture excess was 3.3 g/m3 during the cold period and 0.6 g/m3 during the warm period at the average air change rate of 0.56 h–1 and 0.79 h–1, respectively. Moisture generation indoors was 60 g/h at the average living density of 26 m2/person in the historic wooden apartment buildings. For stochastic analyses in historic wooden buildings, we developed an indoor hygrothermal load model that is in good agreement with measured results.