Daniel Moga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel Moga has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Dorin Petreus
Applied Electronics Department, Faculty of Electronics, Telecommunications and Information Technology, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania
4 shared publications - Vlad Muresan
Automation Department, Faculty of Automation and Computer Science, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania
4 shared publications - Nicoleta Stroia
Faculty of Automation and Computer Science, Technical University of Cluj-Napoca, Cluj-Napoca, Romania, Romania
3 shared publications - Alexandru Lodin
Faculty of Electronics, Telecommunications and Information Technology, Technical University of Cluj-Napoca, 400027 Cluj-Napoca, Romania
2 shared publications - Mihail Abrudean
Automation Department, Technical University of Cluj-Napoca, 28 Memorandumului Street, 400114 Cluj-Napoca, Romania
2 shared publications - Mirela Trusca
Technical University of Cluj-Napoca
2 shared publications
Latest Publications
- Open Access
- 25 November 2026
- Published by MDPI AG in Preprints.org
A Decision-Support Framework for the Management of Water Distribution Networks by Integrating SCADA Data, Measurement Uncertainty and EPANET Hydraulic Modelling
Water utilities increasingly operate SCADA systems reporting network state in real time, yet data is not the same as enough: a measurement adequate for one decision may be useless for another. As a proof of concept, we develop a decision-support framework linking measurement, uncertainty evaluation, hydraulic modelling and the decision in one chain, demonstrated on two tasks: loss detection and judging whether a network can absorb a new demand. On a laboratory rig, flow through orifices of 2.07, 3.12 and 4.07 mm measured diameter was measured as the difference of two in-line readings. A conservative worst-case combination of the meter accuracy limits yields a loss-uncertainty band falling from ±48–55% at 2.07 mm to ±13–15% at 4.07 mm, so detectability depends less on the instrument than on the ratio between loss and transit flow. The discharge coefficient, recomputed with the measured diameters and upstream head, settles at 0.64–0.68 and serves only as a physical bridge to EPANET, not a precise metrological figure. In a demonstrative DMA, a ±20% change in the loss shifts the admissible new-demand limit by only ±0.14 L/s, the decision changing only within a thin band around the threshold. The central proposal is an adequacy test: precision is sufficient whenever propagating its uncertainty leaves the decision classification unchanged, letting the framework judge a decision's robustness and whether extra instrumentation would help.
- 25 November 2026
- Published by MDPI AG in Preprints.org
Open AccessA Decision-Support Framework for the Management of Water Distribution Networks by Integrating SCADA Data, Measurement Uncertainty and EPANET Hydraulic Modelling
Water utilities increasingly operate SCADA systems reporting network state in real time, yet data is not the same as enough: a measurement adequate for one decision may be useless for another. As a proof of concept, we develop a decision-support framework linking measurement, uncertainty evaluation, hydraulic modelling and the decision in one chain, demonstrated on two tasks: loss detection and judging whether a network can absorb a new demand. On a laboratory rig, flow through orifices of 2.07, 3.12 and 4.07 mm measured diameter was measured as the difference of two in-line readings. A conservative worst-case combination of the meter accuracy limits yields a loss-uncertainty band falling from ±48–55% at 2.07 mm to ±13–15% at 4.07 mm, so detectability depends less on the instrument than on the ratio between loss and transit flow. The discharge coefficient, recomputed with the measured diameters and upstream head, settles at 0.64–0.68 and serves only as a physical bridge to EPANET, not a precise metrological figure. In a demonstrative DMA, a ±20% change in the loss shifts the admissible new-demand limit by only ±0.14 L/s, the decision changing only within a thin band around the threshold. The central proposal is an adequacy test: precision is sufficient whenever propagating its uncertainty leaves the decision classification unchanged, letting the framework judge a decision's robustness and whether extra instrumentation would help.
- Open Access
Integrated Smart-Home Architecture for Supporting Monitoring and Scheduling Strategies in Residential Clusters
The monitoring of power consumption and the forecasting of load profiles for residential appliances are essential aspects of the control of energy savings/exchanges at multiple hierarchical levels: house, house cluster, neighborhood, and city. External environmental factors (weather conditions) and inhabitants’ behavior influence power consumption, and their usage as part of forecasting activity may lead to added value in the estimation of daily-load profiles. This paper proposes a distributed sensing infrastructure for supporting the following tasks: the monitoring of appliances’ power consumption, the monitoring of environmental parameters, the generation of records for a database that can be used for both identifying load models and testing load-scheduling algorithms, and the real-time acquisition of consumption data. The hardware/software codesign of an integrated architecture that can combine the typical distributed sensing and control networks present in modern buildings (targeting user comfort) with energy-monitoring and management systems is presented. Methods for generating simplified piecewise linear (PWL) representations of the load profiles based on these records are introduced and their benefits compared with classic averaged representations are demonstrated for the case of peak-shaving strategies. The proposed approach is validated through implementing and testing a smart-meter node with wireless communication and other wired/wireless embedded modules, enabling the tight integration of the energy-monitoring system into smart-home/building-automation systems. The ability of this node to process power measurements with a programable granularity level (seconds/minutes/hours) at the edge level and stream the processed measurement results at the selected granularity to the cloud is identified as a valuable feature for a large range of applications (model identification, power saving, prediction).
Open AccessIntegrated Smart-Home Architecture for Supporting Monitoring and Scheduling Strategies in Residential Clusters
The monitoring of power consumption and the forecasting of load profiles for residential appliances are essential aspects of the control of energy savings/exchanges at multiple hierarchical levels: house, house cluster, neighborhood, and city. External environmental factors (weather conditions) and inhabitants’ behavior influence power consumption, and their usage as part of forecasting activity may lead to added value in the estimation of daily-load profiles. This paper proposes a distributed sensing infrastructure for supporting the following tasks: the monitoring of appliances’ power consumption, the monitoring of environmental parameters, the generation of records for a database that can be used for both identifying load models and testing load-scheduling algorithms, and the real-time acquisition of consumption data. The hardware/software codesign of an integrated architecture that can combine the typical distributed sensing and control networks present in modern buildings (targeting user comfort) with energy-monitoring and management systems is presented. Methods for generating simplified piecewise linear (PWL) representations of the load profiles based on these records are introduced and their benefits compared with classic averaged representations are demonstrated for the case of peak-shaving strategies. The proposed approach is validated through implementing and testing a smart-meter node with wireless communication and other wired/wireless embedded modules, enabling the tight integration of the energy-monitoring system into smart-home/building-automation systems. The ability of this node to process power measurements with a programable granularity level (seconds/minutes/hours) at the edge level and stream the processed measurement results at the selected granularity to the cloud is identified as a valuable feature for a large range of applications (model identification, power saving, prediction).
- Open Access
A Cost-Effective Embedded Platform for Greenhouse Environment Control and Remote Monitoring
This paper presents the development of a cost-effective automatic system for greenhouse environment control. The architectural and functional features were analyzed in the context of the realization of a controlled-environment agricultural system through all its stages: installation, deployment of the software, integration, maintenance, crop control strategy setup and daily operation of the grower. The proposed embedded platform provides remote monitoring and control of the greenhouse environment and is implemented as a distributed sensing and control network integrating wired and wireless nodes. All nodes were built with low-cost, low-power microcontrollers. The key issues that were addressed include the energy-efficient control, the robustness of the distributed control network to faults and a low-cost hardware implementation. The translation of the supervisory growth-planning information to the operational (control network) level is achieved through a specific architecture residing on a crop planning module (CPM) and an interfacing block (IB). A suite of software applications with flows and interfaces developed from a grower-centric perspective was designed and implemented on a multi-tier architecture. The operation of the platform was validated through implementation of sensing and control nodes, application of software for configuration and visualization, and deployment in typical greenhouses.
Open AccessA Cost-Effective Embedded Platform for Greenhouse Environment Control and Remote Monitoring
This paper presents the development of a cost-effective automatic system for greenhouse environment control. The architectural and functional features were analyzed in the context of the realization of a controlled-environment agricultural system through all its stages: installation, deployment of the software, integration, maintenance, crop control strategy setup and daily operation of the grower. The proposed embedded platform provides remote monitoring and control of the greenhouse environment and is implemented as a distributed sensing and control network integrating wired and wireless nodes. All nodes were built with low-cost, low-power microcontrollers. The key issues that were addressed include the energy-efficient control, the robustness of the distributed control network to faults and a low-cost hardware implementation. The translation of the supervisory growth-planning information to the operational (control network) level is achieved through a specific architecture residing on a crop planning module (CPM) and an interfacing block (IB). A suite of software applications with flows and interfaces developed from a grower-centric perspective was designed and implemented on a multi-tier architecture. The operation of the platform was validated through implementation of sensing and control nodes, application of software for configuration and visualization, and deployment in typical greenhouses.
- 1 January 2015
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 48 (30) , 191-196
Modeling, Simulation and Control of a Nonlinear Distributed Parameter Isotope Separation Process
- 1 January 2015
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 48 (30) , 191-196
Modeling, Simulation and Control of a Nonlinear Distributed Parameter Isotope Separation Process
- 1 January 2013
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 46 (6) , 125-130
Novel Control for a Buck Converter used in a DMPPT System
- 1 January 2013
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 46 (6) , 125-130
Novel Control for a Buck Converter used in a DMPPT System
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (21) , 91-96
Fuzzy Digital Control for DC-DC Converters Used in Renewable Energy Systems
- 1 January 2012
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 45 (21) , 91-96
Fuzzy Digital Control for DC-DC Converters Used in Renewable Energy Systems
- 1 January 2010
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 43 (23) , 169-173
Remote Monitoring of Industrial Systems Health
- 1 January 2010
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 43 (23) , 169-173
Remote Monitoring of Industrial Systems Health
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 107-112
Stability of the Fast Voltage Control Loop in DC-DC Converters
This paper describes a method for stability analysis and design of a fast voltage loop in DC-DC converters. The method is based on the Popov criterion, which unifies tools for nonlinear system analysis with frequency domain analysis tools used in linear systems. This study establishes sufficient conditions for absolute stability of time-varying control systems. The proposed conditions extend in a simple way the classical Popov criterion to time-varying memoryless nonlinearities, using previous results of Kharitonov. They are expressed in terms of linear matrix inequalities (LMIs). The controller design procedure is demonstrated and experimentally verified on a DC-DC converter
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 107-112
Stability of the Fast Voltage Control Loop in DC-DC Converters
This paper describes a method for stability analysis and design of a fast voltage loop in DC-DC converters. The method is based on the Popov criterion, which unifies tools for nonlinear system analysis with frequency domain analysis tools used in linear systems. This study establishes sufficient conditions for absolute stability of time-varying control systems. The proposed conditions extend in a simple way the classical Popov criterion to time-varying memoryless nonlinearities, using previous results of Kharitonov. They are expressed in terms of linear matrix inequalities (LMIs). The controller design procedure is demonstrated and experimentally verified on a DC-DC converter
- 1 January 2005
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 38 (1) , 337-342
DESIGNING AND TESTING OF MODERN TOOLS FOR CONTROL SYSTEMS PROTOTYPING
- 1 January 2005
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 38 (1) , 337-342
DESIGNING AND TESTING OF MODERN TOOLS FOR CONTROL SYSTEMS PROTOTYPING