Chung Hui James Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chung Hui James Tan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Andreas B. Imhoff
Sports Orthopaedics, Orthopaedics and Traumatology Department of Orthopaedic Sports Medicine Technical University Hospital Rechts der Isar Munich Germany
1 shared publication - Constantin von Deimling
Department of Orthopaedics -Biomechanics Laboratory, Technische Universität München, Ismaninger Straße 22, Munich, 81675, Germany
1 shared publication Diarmuid Murphy
National University Hospital, Singapore
1 shared publicationFareed Husain Yusuf Kagda
National University Hospital, Singapore
1 shared publication- Frank Martetschläger
Department for Orthopedic Sports Medicine, Technische Universität München, Munich, Germany
1 shared publication - Horazio Martinez
Department of Orthopaedics -Biomechanics Laboratory, Technische Universität München, Ismaninger Straße 22, Munich, 81675, Germany
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 4 January 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-8
Effect of three remplissage techniques on tendon coverage and shoulder kinematics: a navigated robotic biomechanical study
In addition to Bankart repair engaging Hill-Sachs defects in glenohumeral instability have been treated successfully with remplissage procedure. The purpose of this study was to compare three remplissage techniques regarding (I) ability of preventing Hill-Sachs defect from engaging, (II) influence on glenohumeral rotational torque, and (III) resulting tendon coverage over the Hill-Sachs defect. Standardized engaging Hill-Sachs defects and Bankart lesions were created in n = 7 fresh frozen human shoulder specimens. Besides Bankart repair three remplissage techniques (T) with double anchor position in the valley of the defect zone were studied: T1, knots tied over anchors; T2, knots tied between anchors (double-pulley); T3, knotless anchors with a suture tape. A parallel position-orientation and force-moment controlled navigated roboticsystem was used to compare prevention of Hill-Sachs defect engagement and torque [Nm]. Pressure sensitive film was used to study area of infraspinatus tendon coverage over Hill-Sachs defect [%]. All remplissage techniques prevented engagement of the Hill-Sachs defect without showing any construct failures. Regarding humeral torque there were significant impairments observed between intact conditions and the three investigated repair techniques in 60° abduction and ≥30° external rotation (p < .04). There was no significant difference in torque between intervention groups (n.s.). With a mean coverage of 26.8 % over the defect zone the knotless suture tape technique (T3) significantly improved area of soft tissue coverage compared to the other techniques (p = .03). All remplissage techniques prevented engagement of the Hill Sachs defect. With high abduction and external rotation ≥30° all techniques showed significant higher humeral torque compared to the intact specimens, while there was not one technique superior over the others. The suture tape technique conferred the largest and most effective area of tendon coverage over the Hill-Sachs defect zone. Long-term success of the remplissage procedure can possibly be enhanced by increasing the interface area of tendon coverage over the Hill-Sachs defect. Clinical studies will be necessary to proof potential benefits for clinical outcome.
- 4 January 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-8
Top Cited PapersOpen AccessEffect of three remplissage techniques on tendon coverage and shoulder kinematics: a navigated robotic biomechanical study
In addition to Bankart repair engaging Hill-Sachs defects in glenohumeral instability have been treated successfully with remplissage procedure. The purpose of this study was to compare three remplissage techniques regarding (I) ability of preventing Hill-Sachs defect from engaging, (II) influence on glenohumeral rotational torque, and (III) resulting tendon coverage over the Hill-Sachs defect. Standardized engaging Hill-Sachs defects and Bankart lesions were created in n = 7 fresh frozen human shoulder specimens. Besides Bankart repair three remplissage techniques (T) with double anchor position in the valley of the defect zone were studied: T1, knots tied over anchors; T2, knots tied between anchors (double-pulley); T3, knotless anchors with a suture tape. A parallel position-orientation and force-moment controlled navigated roboticsystem was used to compare prevention of Hill-Sachs defect engagement and torque [Nm]. Pressure sensitive film was used to study area of infraspinatus tendon coverage over Hill-Sachs defect [%]. All remplissage techniques prevented engagement of the Hill-Sachs defect without showing any construct failures. Regarding humeral torque there were significant impairments observed between intact conditions and the three investigated repair techniques in 60° abduction and ≥30° external rotation (p < .04). There was no significant difference in torque between intervention groups (n.s.). With a mean coverage of 26.8 % over the defect zone the knotless suture tape technique (T3) significantly improved area of soft tissue coverage compared to the other techniques (p = .03). All remplissage techniques prevented engagement of the Hill Sachs defect. With high abduction and external rotation ≥30° all techniques showed significant higher humeral torque compared to the intact specimens, while there was not one technique superior over the others. The suture tape technique conferred the largest and most effective area of tendon coverage over the Hill-Sachs defect zone. Long-term success of the remplissage procedure can possibly be enhanced by increasing the interface area of tendon coverage over the Hill-Sachs defect. Clinical studies will be necessary to proof potential benefits for clinical outcome.
- Open Access
- 11 May 2012
- Published by Bentham Science Publishers Ltd. in The Open Orthopaedics Journal
- Vol. 6 (1) , 184-188
Minimally Invasive Helical Plating for Shaft of Humerus Fractures: Technique and Outcome
Introduction: The humerus is subjected to substantial amount of torsional stress. Conventional plating may not address this sufficiently and may lead to fixation failure or non-union. A helical plate may offer the solution. We present the surgical technique and functional outcome of 5 cases of humeral shaft fractures treated with this technique in a minimally invasive way. Materials and Methods: The operations were performed between 2004 and 2010, by three surgeons. All the patients had closed humeral shaft fractures, either simple transverse or with mild comminution. Two small incisions were made. The proximal incision was placed along the deltopectoral groove over the shaft, and the distal incision was placed as in an antero-lateral approach. The radial nerve was identified and protected. A pre-selected plate was contoured and introduced in the submuscular plane. The plate was placed in a proximal-lateral and distal-anterior position. Screws were inserted through stab incisions. The patients were followed for an average of 6 months. Functional recovery of the shoulder and elbow was assessed using the Constant and Mayo elbow performance score systems. Results: All incisions healed by first intention without complications and all the fractures went on to unite. All patients achieved good to excellent shoulder and elbow function. Conclusion: The helical plate technique is a safe and effective method of treating humeral shaft fractures and has good functional outcome.
- 11 May 2012
- Published by Bentham Science Publishers Ltd. in The Open Orthopaedics Journal
- Vol. 6 (1) , 184-188
Open AccessMinimally Invasive Helical Plating for Shaft of Humerus Fractures: Technique and Outcome
Introduction: The humerus is subjected to substantial amount of torsional stress. Conventional plating may not address this sufficiently and may lead to fixation failure or non-union. A helical plate may offer the solution. We present the surgical technique and functional outcome of 5 cases of humeral shaft fractures treated with this technique in a minimally invasive way. Materials and Methods: The operations were performed between 2004 and 2010, by three surgeons. All the patients had closed humeral shaft fractures, either simple transverse or with mild comminution. Two small incisions were made. The proximal incision was placed along the deltopectoral groove over the shaft, and the distal incision was placed as in an antero-lateral approach. The radial nerve was identified and protected. A pre-selected plate was contoured and introduced in the submuscular plane. The plate was placed in a proximal-lateral and distal-anterior position. Screws were inserted through stab incisions. The patients were followed for an average of 6 months. Functional recovery of the shoulder and elbow was assessed using the Constant and Mayo elbow performance score systems. Results: All incisions healed by first intention without complications and all the fractures went on to unite. All patients achieved good to excellent shoulder and elbow function. Conclusion: The helical plate technique is a safe and effective method of treating humeral shaft fractures and has good functional outcome.