Nathan D. Jacob
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nathan D. Jacob has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Behzad Kordi
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, Canada
4 shared publications - Jeff Laninga
Department of Electrical & Computer Engineering, Price Faculty of Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada
2 shared publications - Ali Nasr Esfahani
Faculty of Administrative Sciences and Economic, University of Isfahan, Isfahan, Iran
1 shared publication - Aniruddha M. Gole
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, MB, Canada
1 shared publication - Anupa Ekanayaka
University of Manitoba, Winnipeg, Canada
1 shared publication - Gevindu Ediriweera
University of Manitoba, Winnipeg, Canada
1 shared publication
Latest Publications
- Open Access
- 7 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Experimental investigation of air insulation characteristics under AC voltage in smoky conditions due to remote wildfire considering the impact of humidity
- 7 September 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Open AccessExperimental investigation of air insulation characteristics under AC voltage in smoky conditions due to remote wildfire considering the impact of humidity
- Open Access
Monitoring Technologies for HVDC Transmission Lines
HVDC transmission systems are becoming more prevalent because of the advantages they offer. They are more efficient and environmentally friendly and are becoming preferred in distributed power generation. The reliable operation of HVDC transmission lines requires distributed, online monitoring, which is not as well-developed as those in an HVAC system. The advancement of HVDC systems will require online monitoring that provides information on the operating and environmental conditions, mechanical stress on the conductors and the structure, vegetation clearance, and security of the system. This perspective paper provides a thorough overview of the state-of-the-art technologies that are applicable to the monitoring of HVDC transmission lines. The challenges and future direction in the development of sensors for HVDC applications are highlighted. One of the key challenges unique to HVDC transmission lines is energy harvesting from the transmission line conductors to provide power for the monitoring equipment. This paper reviews the potential technologies for energy harvesting from HVAC transmission lines and their suitability for employment in HVDC transmission lines.
Open AccessMonitoring Technologies for HVDC Transmission Lines
HVDC transmission systems are becoming more prevalent because of the advantages they offer. They are more efficient and environmentally friendly and are becoming preferred in distributed power generation. The reliable operation of HVDC transmission lines requires distributed, online monitoring, which is not as well-developed as those in an HVAC system. The advancement of HVDC systems will require online monitoring that provides information on the operating and environmental conditions, mechanical stress on the conductors and the structure, vegetation clearance, and security of the system. This perspective paper provides a thorough overview of the state-of-the-art technologies that are applicable to the monitoring of HVDC transmission lines. The challenges and future direction in the development of sensors for HVDC applications are highlighted. One of the key challenges unique to HVDC transmission lines is energy harvesting from the transmission line conductors to provide power for the monitoring equipment. This paper reviews the potential technologies for energy harvesting from HVAC transmission lines and their suitability for employment in HVDC transmission lines.
- Open Access
Evaluation of Erosion Discharge Characteristics in Inclined Plane Tracking and Erosion Tests on Silicone Rubber under AC and DC Voltages
This paper investigates partial discharge (PD) characteristics that lead to the erosion of silicone rubber (SR) polymer under AC stress and DC stress of both polarities. The experiments are performed on high temperature vulcanized (HTV) SR material samples. The inclined plane test apparatus, constructed in accordance with IEC 60587 requirements, is employed to produce the surface partial discharges and the resulting accelerated aging of the specimens. Two commercial instruments are used to obtain the PD data. A concurrent analysis of visual observations of discharge and PD data is performed to classify discharges based on the severity of material degradation that each type causes. Three types of PD are identified and characterized using diagrams of charge magnitude versus time and a signal processing technique called time-frequency mapping. Individual pulse waveshapes of each type of discharge are also analyzed. PD pulse waveforms are analyzed according to their amplitude, energy, pulse width, and frequency spectrum. These pulse waveform parameters are evaluated and compared for the eroding discharge pulses under AC and DC voltage stresses. It is found that the stages of material degradation during IPT are related to the variations in discharge magnitude and the location of pulse clusters on the time-frequency maps.
Open AccessEvaluation of Erosion Discharge Characteristics in Inclined Plane Tracking and Erosion Tests on Silicone Rubber under AC and DC Voltages
This paper investigates partial discharge (PD) characteristics that lead to the erosion of silicone rubber (SR) polymer under AC stress and DC stress of both polarities. The experiments are performed on high temperature vulcanized (HTV) SR material samples. The inclined plane test apparatus, constructed in accordance with IEC 60587 requirements, is employed to produce the surface partial discharges and the resulting accelerated aging of the specimens. Two commercial instruments are used to obtain the PD data. A concurrent analysis of visual observations of discharge and PD data is performed to classify discharges based on the severity of material degradation that each type causes. Three types of PD are identified and characterized using diagrams of charge magnitude versus time and a signal processing technique called time-frequency mapping. Individual pulse waveshapes of each type of discharge are also analyzed. PD pulse waveforms are analyzed according to their amplitude, energy, pulse width, and frequency spectrum. These pulse waveform parameters are evaluated and compared for the eroding discharge pulses under AC and DC voltage stresses. It is found that the stages of material degradation during IPT are related to the variations in discharge magnitude and the location of pulse clusters on the time-frequency maps.
- 4 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 30 (4) , 1949-1957
Impulse Generator Optimum Setup for Transient Testing of Transformers Using Frequency-Response Analysis and Genetic Algorithm
A novel optimization-enabled electromagnetic transient simulation approach is proposed for calculating the resistor setting of a multistage impulse generator for insulation impulse testing of high-voltage transformers. This approach enables test engineers to overcome most of the major challenges attributed to the use of conventional trial-and-error methods for determining resistor settings, including the excessive time consumption and the potential damage to the test transformer due to a greater number of trial tests. The proposed method uses the frequency response of the test transformer to synthesize a circuit model for it. The test setup, including the test transformer and the impulse generator, is simulated using an electromagnetic-transients-type simulator. A genetic-algorithm-based approach is used to optimize the setting of the impulse generator. Optimized resistor values are then used in impulse testing of a three-phase power transformer. Different cases of impulse generator resistor arrangements are studied in this paper and simulated waveforms are compared with those obtained from measurements.
- 4 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 30 (4) , 1949-1957
Impulse Generator Optimum Setup for Transient Testing of Transformers Using Frequency-Response Analysis and Genetic Algorithm
A novel optimization-enabled electromagnetic transient simulation approach is proposed for calculating the resistor setting of a multistage impulse generator for insulation impulse testing of high-voltage transformers. This approach enables test engineers to overcome most of the major challenges attributed to the use of conventional trial-and-error methods for determining resistor settings, including the excessive time consumption and the potential damage to the test transformer due to a greater number of trial tests. The proposed method uses the frequency response of the test transformer to synthesize a circuit model for it. The test setup, including the test transformer and the impulse generator, is simulated using an electromagnetic-transients-type simulator. A genetic-algorithm-based approach is used to optimize the setting of the impulse generator. Optimized resistor values are then used in impulse testing of a three-phase power transformer. Different cases of impulse generator resistor arrangements are studied in this paper and simulated waveforms are compared with those obtained from measurements.