ODOmer Doron

Omer Doron

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Omer Doron has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Correction to: Results from a first-in-human phase I safety trial to evaluate the use of a vascularized pericranial/temporoparietal fascial flap to line the resection cavity following resection of newly diagnosed glioblastoma

    by Omer Doron, Tamika Wong, Faina Ablyazova, Souvik Singha, Julianna Cavallaro, Netanel Ben-Shalom, Randy S. D’aMico, Manju Harshan, Amy McKeown, Avraham Zlochower, et al.

  • Open Access

    Results from a first-in-human phase I safety trial to evaluate the use of a vascularized pericranial/temporoparietal fascial flap to line the resection cavity following resection of newly diagnosed glioblastoma

    by Omer Doron, Tamika Wong, Faina Ablyazova, Souvik Singha, Julianna Cavallaro, Netanel Ben-Shalom, Randy S. D’amico, Manju Harshan, Amy McKeown, Avraham Zlochower, et al.

    Purpose The efficacy of systemic therapies for glioblastoma (GBM) remains limited due to the constraints of systemic toxicity and blood–brain barrier (BBB) permeability. Temporoparietal fascial flaps (TPFFs) and vascularized peri cranial flaps (PCF) are not restricted by the blood–brain barrier (BBB), as they derive their vascular supply from branches of the external carotid artery. Transposition of a vascularized TPFF or PCF along a GBM resection cavity may bring autologous tissue not restricted by the BBB in close vicinity to the tumor bed microenvironment, permit ingrowth of vascular channels fed by the external circulation, and offer a mechanism of bypassing the BBB. In addition, circulating immune cells in the vascularized flap may have better access to tumor-associated antigens (TAA) within the tumor microenvironment. We conducted a first-in-human Phase I trial assessing the safety of lining the resection cavity with autologous TPFF/PCF of newly diagnosed patients with GBM. Methods 12 patients underwent safe, maximal surgical resection of newly diagnosed GBMs, followed by lining of the resection cavity with a pedicled, autologous TPFF or PCF. Safety was assessed by monitoring adverse events. Secondary analysis of efficacy was examined as the proportion of patients experiencing progression-free disease (PFS) as indicated by response assessment in neuro-oncology (RANO) criteria and overall survival (OS). The study was powered to determine whether a Phase II study was warranted based on these early results. For this analysis, subjects who were alive and had not progressed as of the date of the last follow-up were considered censored and all living patients who were alive as of the date of last follow-up were considered censored for overall survival. For simplicity, we assumed that a 70% PFS rate at 6 months would be considered an encouraging response and would make an argument for further investigation of the procedure. Results Median age of included patients was 57 years (range 46–69 years). All patients were Isocitrate dehydrogenase (IDH) wildtype. Average tumor volume was 56.6 cm3 (range 14–145 cm3). Resection was qualified as gross total resection (GTR) of all of the enhancing diseases in all patients. Grade III or above adverse events were encountered in 3 patients. No Grade IV or V serious adverse events occurred in the immediate post-operative period including seizure, infection, stroke, or tumor growing along the flap. Disease progression at the site of the original tumor was identified in only 4 (33%) patients (median 23 months, range 8–25 months), 3 of whom underwent re-operation. Histopathological analyses of those implanted flaps and tumor bed biopsy at repeat surgery demonstrated robust immune infiltrates within the transplanted flap. Importantly, no patient demonstrated evidence of tumor infiltration into the implanted flap. At the time of this manuscript preparation, only 4/12 (33%) of patients have died. Based on the statistical considerations above and including all 12 patients 10/12 (83.3%) had 6-month PFS. The median PFS was 9.10 months, and the OS was 17.6 months. 4/12 (33%) of patients have been alive for more than two years and our longest surviving patient currently is alive at 60 months. Conclusions This pilot study suggests that insertion of pedicled autologous TPFF/PCF along a GBM resection cavity is safe and feasible. Based on the encouraging response rate in 6-month PFS and OS, larger phase II studies are warranted to assess and reproduce safety, feasibility, and efficacy. Trial registration number and date of registration for prospectively registered trials ClinicalTrials.gov ID NCT03630289, dated: 08/02/2018.


  • Troubleshooting the bypass: intraoperative management of initially failed anastomosis in direct cerebral revascularization surgery

    by Omer Doron, Devon B. O’donnell, Colin Dallimore, Hamza Khilji, Jacob D. Greisman, Michelle Villagran, Rafael A. Ortiz, Erez Nossek, Jason A. Ellis, David J. Langer

    OBJECTIVE: Direct cerebral revascularization is considered as one of the most technically challenging operations in neurosurgery. Technical errors are often not identified during the case, but only after the recirculation stage, making management crucial at that time of the procedure. In this study, the authors sought to describe troubleshooting of the technical errors encountered in initially failed bypass cases. METHODS: A retrospective analysis describing a single-surgeon, single-institution experience between 2014 and 2021 was performed, based on operative reports and videos, including a 30-day follow-up period. Initially failed bypass was defined if the bypass was not patent or had a significant leak after recirculation, irrespective of the final result. RESULTS: One hundred thirty-eight bypass cases were reviewed for complex aneurysms (n = 49), moyamoya disease (n = 59), and atherosclerosis (n = 30). Fifty-one initially failed anastomoses were identified; 43 of these were the result of a technical error. Etiologies of these failed anastomoses included a clot (n = 14), vessel kinking (n = 4), spasm (n = 5), suture-related cause (n = 5), inappropriate donor or recipient (n = 3), or lack of demand (n = 8). A major leak was attributed to an uncoagulated side branch (n = 4), vessel injury due to suture/clip placement (n = 1), or inadequate suture line coverage (n = 7). Thirty-seven (86%) of 43 cases were troubleshot successfully, as salvage maneuvers included papaverine vessel massage, donor repositioning, re-anastomosis for occlusion in select cases, local hemostatic agents, and suturing or coagulating side branches in a leak. Thirty-day follow-up revealed similar rates of patency between successfully troubleshot patients (35/37) and the rest of the cases (80/87, p = 0.6). CONCLUSIONS: Three major patterns of a noncompatible bypass were found: a major leak, an acute occlusion, or a delayed occlusion. Based on the authors’ experience, salvage strategies proved successful, showing an eventual high patency rate. The authors suggest a gradual, structured algorithm to address this stage in surgery that may contribute specifically to cerebrovascular neurosurgeons at the beginning of their careers.


  • Coronary balloon-assisted navigation of aspiration catheter for stroke thrombectomy

    by Semyon Chulsky, Gil Zur, Omer Doron, Tzvika Sacagiu, Eitan Abergel

    In recent years, A Direct Aspiration First Pass Technique (ADAPT) has emerged as an effective and safe method of thrombectomy. Large trials have shown noninferiority of ADAPT compared to primary stent retriever approach, while new studies emphasize on its shorter procedural time with potentially fewer complications and costs. 1,2 . Failure of the A Direct Aspiration First Pass Technique (ADAPT) is often due to the inability to successfully navigate the aspiration catheter to the thrombus site. As a solution, several techniques have been considered such as the use of stiffer microcatheters or a wedge device. 3 In Video 1 , we present our technique of navigating aspiration catheters with the assistance of coronary balloons. This technique has been very successful in our experience of about 30 cases in the past 6 months. Thanks to its safety and efficacy, this technique has dramatically changed our technical management of acute ischemic stroke. It can increase the ADAPT success rate while potentially reducing procedural costs.


  • Neurovascular Interventions for Neurotrauma: From Treatment of Injured Vessels to Treatment of the Injured Brain?

    by Omer Doron, Aman B. Patel, Gregory W. J. Hawryluk

    Traumatic brain injury is often associated with a direct or secondary neurovascular pathology. In this review, we present recent advancements in endovascular neurosurgery that enable accurate and effective vessel reconstruction with emphasis on its role in early diagnosis, the expanding use of flow diversion in pseudoaneurysms, and traumatic arteriovenous fistulas. In addition, future directions in which catheter-based interventions could potentially affect traumatic brain injury are described: targeting blood brain barrier integrity using the advantages of intra-arterial drug delivery of blood brain barrier stabilizers to prevent secondary brain edema, exploring the impact of endovascular venous access as a means to modulate venous outflow in an attempt to reduce intracranial pressure and augment brain perfusion, applying selective intra-arterial hypothermia as a neuroprotection method mitigating some of the risks conferred by systemic cooling, trans-vessel wall delivery of regenerative therapy agents, and shifting attention using multimodal neuromonitoring to post-traumatic vasospasm to further characterize the role it plays in secondary brain injury. Thus, we believe that the potential of endovascular tools can be expanded because they enable access to the “highways” governing perfusion and flow and call for further research focused on exploring these routes because it may contribute to novel endovascular approaches currently used for treating injured vessels, harnessing them for treatment of the injured brain.


  • Open Access

    O-030 Arteriovenous coherence: a potential novel parameter for quantifying AVM hemodynamics using wavelet brain angiography

    by O Doron, J Vranic, C Stapleton, R Regenhardt, A Patel, W Butler

    Background Quantifiable parameters that can capture the hemodynamic profile of an AVM are lacking, as current methods of AVM assessment are descriptive. Recently, we have established a novel computational method to analyze vascular pulse waves (depicted by peak contrast bolus) from cerebral angiograms paired with the cardiac signal obtained by a pulse oximeter, showing normal arteriovenous coupling in the human brain. Latency reflecting propagation of the pressure waves pushing the contrast was observed between arterial and venous sides. We sought to explore cerebral AVMs and characterize disturbed arteriovenous (AV) coherence based on phase-shift between the peak frequency seen on arterial peak and the venous side. Materials and Methods Computational methods (figure 1) permitting the capture and analysis of cardiac frequency phenomena from angiograms in 4 patients with AVMs, before and after embolization were employed. Phase shift was calculated between the feeding artery relative to draining vein and remote non-AVM vein. Results Average phase shift between feeding artery and draining vein was significantly smaller compared to feeding artery and remote vein (122 vs 64 degrees, pDiscussion This study describes the method and potential role of wavelet angiography in the hemodynamic profiling of the AVMs. By calculating AV coherence, quantifying AV phase shift before and after embolization was explored and can pave the way for numerical assessment of the impact of intervention on AVM functional angioarchitecture. Future studies are needed to create AV coherence weighted-maps to explore hemodynamic compartmentalization, assessment of risk related to level of coherence and the impact of partial embolization on AVM hemodynamics. Disclosures O. Doron: None. J. Vranic: None. C. Stapleton: None. R. Regenhardt: None. A. Patel: None. W. Butler: None.

  • Open Access

    FRED Jr stent for acute flow diversion in ruptured cerebral aneurysms arising from small-caliber vessels: a clinical case series

    by Omer Doron, Rachel McLellan, Justin E. Vranic, Robert W. Regenhardt, Christopher J. Stapleton, Aman B. Patel

    OBJECTIVE: Treatment of ruptured aneurysms arising from small-caliber (< 2.5 mm) or distal vessels beyond the circle of Willis is considered challenging with all treatment modalities. Recently, the Flow Re-Direction Endoluminal Device Junior (FRED Jr) stent, designed for flow diversion in small arteries, was approved in the United States for the treatment of nonruptured aneurysms. Here, the authors report their experience using this device in the setting of subarachnoid hemorrhage (SAH). METHODS: Clinical and radiological records of patients sustaining SAH treated with a FRED Jr stent between June 2020 and October 2022 were reviewed. Treatment course, including antiplatelet therapy, external ventricular drain (EVD) management, and vasospasm, and clinical outcomes were analyzed. Angiographic results were assessed according to the O’Kelly-Marotta (OKM) grading scale. RESULTS: Nine patients at a median age of 62 (range 27–75) years were included. The median Hunt and Hess grade was II (IQR I) and the median modified Fisher grade was 4 (IQR 1). Aneurysm morphology types included saccular (6 patients), blister (1 patient), and dissecting (2 patients), and the aneurysms were located at the anterior communicating artery complex (n = 3) at the A2/A3 (n = 3), M2/M3 (n = 1), V4 (n = 1), and P2 (n = 1) arterial segments. All stents were deployed successfully with no intraprocedural complications. Postoperatively, no rebleeding events were encountered. Vasospasm therapy was initiated in 6 patients, and no symptomatic EVD-related hematomas were observed. Postoperative ischemic events were encountered in 2 patients. The median 3-month modified Rankin Scale score was 2 (IQR 1) for the 7 surviving patients, and 3-month radiographic follow-up revealed OKM grade D in 4 of 7 patients. CONCLUSIONS: Flow diversion using the FRED Jr stent is feasible as a potential treatment strategy for acutely ruptured aneurysms arising from small-caliber vessels. The complication profile reported in this series is comparable to those of historical microsurgical cohorts, and effective protection was conferred by this treatment modality. Therefore, our small cohort provides a glimpse into a new tool for successfully achieving acute flow diversion for this subset of difficult-to-treat aneurysms.


  • The “pipe-anchor” technique: A method for intra-aneurysmal loop reduction using a partially unsheathed pipeline stent

    by Omer Doron, Justin Vranic, Robert Regenhardt, Christopher Stapleton, Aman Patel

    Purpose: Large aneurysms often present a challenge for endovascular navigation, as they may require utilization of “around-the-world” technique for distal access. In this study, we describe the use of a pipeline stent to stabilize the microcatheter allowing gradual unsheathing and straightening of the microcatheter within the aneurysm enabling stent deployment. Methods: A pipeline stent is partially deployed distal to the aneurysm, after using intra-aneurysmal loop (“around-the-world”) to cross the aneurysm. Partially unsheathed, using its radial force and vessel wall friction to establish an anchoring point, the microcatheter is stabilized and pulled with the stent locked to gradually to allow loop reduction and microsystem straightening, allowing unsheathing as the microsystem is aligned with the inflow and outflow vessel. Results: Two patients harboring cavernous segment aneurysms (measuring 18 × 12 mm and 21 × 24 mm) were treated by 3.75 × 25 mm and 4.25 × 25 mm pipeline devices, respectively, using this technique, deployed through a Phenom 0.027” microcatheter. Patients did well clinically with no thromboembolic complications, as follow-up imaging demonstrated good wall apposition and appreciable contrast stagnation. Conclusion: Anchoring for loop reduction was previously described using a non-flow diverter stents or balloon requiring additional devices and exchange maneuvers to deploy a pipeline. The “pipe anchor” technique describes the use of a partially deployed flow diverter system as an anchor. This report suggests that pipeline radial force, albeit low, is sufficient. We believe that this method is worthy of consideration in select cases as a first choice and can be valuable tool in the armamentarium of the endovascular neurosurgeon.


  • Intracranial Pulsating Balloon-Based Cardiac-Gated ICP Modulation Impact on Brain Oxygenation: A Proof-of-Concept Study in a Swine Model

    by Omer Doron, Yuliya Zadka, Guy Rosenthal, Ofer Barnea

    Background Brain oxygenation improvement is a sought-after goal in neurocritical care patients. Previously, we have shown that cerebral blood flow improvement by cardiac-gated intracranial pressure (ICP) modulation using an intracranial pulsating balloon is feasible in a swine model. We sought to explore specific ICP modulation protocols to assess the feasibility of influencing brain oxygenation. Methods A previously presented electrocardiogram (ECG)-gated intracranial balloon pump in which volume, timing, and duty cycle of balloon inflation could be altered was used. Different protocols were tested in a swine model of normal and elevated ICP attained by intracranial fluid infusion with continuous monitoring of physiological parameters, and brain tissue oxygen tension (PbtO2) was measured at baseline and after device activation. Results We studied five swine, subjected to two main protocols differing in their phase relative to the cardiac cycle. In reduced brain perfusion status (ICP > 20 mm Hg, PbtO2 < 15 mm Hg), the late-diastolic-early-systolic (Inflation/deflation) protocol showed consistent elevation in PbtO2 (+ 9%, p < 0.01), coupled with ICP reduction (− 12%, p < 0.01), whereas the early-systolic-late-diastolic (inflation/deflation) protocol resulted in PbtO2 reduction (− 4%, p < 0.01), coupled with ICP increase (+ 5% above baseline, p < 0.01). No significant changes in brain oxygenation or ICP were observed at normal perfusion status (ICP < 20 mm Hg, PbtO2 > 15 mm Hg). Conclusions Intracranial cardiac-gated balloon pump activation can influence cerebral oxygenation and raise PbtO2 above threshold values. This study supports the concept of late-diastolic pressure rise, coupled with early-systolic pressure drop, as a potential effector of flow augmentation leading to improve brain tissue oxygenation. Further studies are warranted to assess the translational potential of using an intracranial cardiac-gated balloon pump device to improve brain tissue oxygenation.


  • Open Access

    Application of the subdural evacuating port system for the drainage of postoperative tension pneumocephalus: A technical note

    by Omer Doron, Julia R. Schneider, Jason Andre Ellis

    Background: Tension pneumocephalus is a neurosurgical emergency requiring prompt intervention. A variety of either temporizing or definitive methods was previously described as part of its management. Here, we report on an off-label use of a bed-side device and the subdural evacuating port system (SEPS)™ for the treatment of tension pneumocephalus. Methods: The SEPS™ (Medtronic Dublin, Ireland) is a minimally invasive tool that is indicated for the removal of chronic or subacute subdural hematomas and at the patient’s bedside. We describe the use of this system to evacuate tension pneumocephalus. Results: A 44-year-old patient operated in our institution was presented with sudden obtundation 4 days post resection of esthesioneuroblastoma. Imaging confirmed a significant tension pneumocephalus. Immediate bedside decompression using a SEPS bolt placed frontally was performed, achieving rapid evacuation and patient regained consciousness. A definitive skull base reconstruction was done at the operating room at a later stage. Conclusion: The SEPS™, well-known for evacuation of CSDH, can be potentially used as a bed-side tool to effectively treat mass effect created by tension pneumocephalus. As a readily-available and commercially used device, it can provide a simple and standard toolkit suitable for an emergent temporizing procedure.