Shimon Maimon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shimon Maimon has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Eitan Abergel
Rambam Health Care Campus, Haifa, Israel
1 shared publication - Gil Zur
Rambam Health Care Campus, Haifa, Israel
1 shared publication - Goni Merhav
Rambam Health Care Campus, Haifa, Israel
1 shared publication - Ido Strauss
Gray Faculty of Medical and Health Sciences Tel Aviv University Tel Aviv Israel
1 shared publication
Latest Publications
- 5 March 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1207-1211
Endovascular stenting of bilateral hypoplastic jugular bulb in a toddler with elevated intracranial pressure: a case report
- 5 March 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1207-1211
Endovascular stenting of bilateral hypoplastic jugular bulb in a toddler with elevated intracranial pressure: a case report
- 2 December 2015
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 158 (2) , 247-254
Silk flow diverter in the treatment of complex intracranial aneurysms: a single-center experience with 60 patients
Flow diverters are used to treat complex aneurysms that are not amenable to coiling. The aim of the present work was to retrospectively evaluate our experience with the Silk flow diverter. Technical nuances and complications are specifically discussed. Retrospectively data was collected on patients treated with Silk between October 2008 and October 2013. Sixty patients harboring 67 aneurysms were treated using the Silk. Fifteen aneurysms were located in the posterior circulation and 52 in the anterior. A good angiographic result was achieved in 88 % (53/60) of the aneurysms available for imaging follow-up. There were ten treatment-related complications, 80 % were ischemic. Risk of complications increased with aneurysm size and in aneurysms of the posterior circulation. Silk flow diverters are a good treatment option for aneurysms of the anterior circulation. Additional stents may be required in specific cases due to the Silk’s low radial resistance. Treatment of giant fusiform aneurysms of the posterior circulation with Silk flow diverters is associated with a high rate of severe complications.
- 2 December 2015
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 158 (2) , 247-254
Silk flow diverter in the treatment of complex intracranial aneurysms: a single-center experience with 60 patients
Flow diverters are used to treat complex aneurysms that are not amenable to coiling. The aim of the present work was to retrospectively evaluate our experience with the Silk flow diverter. Technical nuances and complications are specifically discussed. Retrospectively data was collected on patients treated with Silk between October 2008 and October 2013. Sixty patients harboring 67 aneurysms were treated using the Silk. Fifteen aneurysms were located in the posterior circulation and 52 in the anterior. A good angiographic result was achieved in 88 % (53/60) of the aneurysms available for imaging follow-up. There were ten treatment-related complications, 80 % were ischemic. Risk of complications increased with aneurysm size and in aneurysms of the posterior circulation. Silk flow diverters are a good treatment option for aneurysms of the anterior circulation. Additional stents may be required in specific cases due to the Silk’s low radial resistance. Treatment of giant fusiform aneurysms of the posterior circulation with Silk flow diverters is associated with a high rate of severe complications.